Shopping Cart

No products in the cart.

ICC IBC 2021 1stptg

$82.08

International Building Code, 2nd Printing

Published By Publication Date Number of Pages
ICC 2021 833
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This code applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2021 IBC® contains many important changes such as: Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements. For the purposes of determining the allowable number of control areas in a building, each portion separated by one or more fire walls is now considered as a separate building. In Group E occupancies, enhanced classroom acoustics in compliance with ICC A117.1 are to be provided in all classrooms having of volume of 20,000 cubic feet or less. The requirements for metal composite materials and systems (MCM) installed on the exterior walls of Types I, II, III and IV construction were simplified and sprinkler allowances were deleted The use of intermodal shipping containers as buildings is now specifically addressed through provisions intended to supplement existing applicable IBC requirements. Automatic sprinkler protection is now required in Group S-2 open parking garages where any fire area exceeds 48,000 square feet. The 2017 edition of ICC A117.1 was adopted. Parapets of a minimum height are now required for aggregate-surfaced roofs to prevent blow-off. Mixed occupancy buildings with assembly spaces are placed in Risk Category III when the total public assembly occupant load is greater than 2500 people. The 2021 IBC snow map is updated to match ASCE 7-16 snow maps by adding a reference to ASCE 7 snow tables in states with large case study areas. Secondary rain loads are updated to be consistent with ASCE 7. Special inspection requirements were added to address the anchorage and connection of mass timber structural elements. Installation of firestop, fire-resistant joint systems and perimeter fire barrier systems in residential-use buildings now requires special inspection in Group R fire areas having an occupant load exceeding 250 people. Frost protection for egress doors was added to the foundation requirements. ACI standards ACI 117 and ITG 7 were added by reference to provide acceptable tolerances for concrete construction. Three new types of construction (Types IV-A, IV-B, and IV-C) allow mass timber buildings of taller heights, more stories above grade, and greater allowable areas compared to existing provisions for heavy timber buildings.

PDF Catalog

PDF Pages PDF Title
1 2021 IBC® INTERNATIONAL BUILDING CODE®
2 2021 IBC® INTERNATIONAL BUILDING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
12 ARRANGEMENT AND FORMAT OF THE 2021 IBC
24 TABLE OF CONTENTS
32 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
33 SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
35 SECTION 105 PERMITS
37 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 CONSTRUCTION DOCUMENTS
38 SECTION 108 TEMPORARY STRUCTURES AND USES
39 SECTION 109 FEES
SECTION 110 INSPECTIONS
40 SECTION 111 CERTIFICATE OF OCCUPANCY
41 SECTION 112 SERVICE UTILITIES
SECTION 113 MEANS OF APPEALS
SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
42 SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
44 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
76 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
77 SECTION 304 BUSINESS GROUP B
78 SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
79 SECTION 307 HIGH-HAZARD GROUP H
80 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
81 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
82 TABLE 307.1(2) [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
83 SECTION 308 INSTITUTIONAL GROUP I
84 SECTION 309 MERCANTILE GROUP M
85 SECTION 310 RESIDENTIAL GROUP R
86 SECTION 311 STORAGE GROUP S
87 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
88 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
91 EQUATION 4-1
92 SECTION 403 HIGH-RISE BUILDINGS
93 TABLE 403.2.3 MINIMUM BOND STRENGTH
95 SECTION 404 ATRIUMS
96 SECTION 405 UNDERGROUND BUILDINGS
97 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
100 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
102 SECTION 407 GROUP I-2
105 SECTION 408 GROUP I-3
108 SECTION 409 MOTION PICTURE PROJECTION ROOMS
SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
110 SECTION 411 SPECIAL AMUSEMENT AREAS
111 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
113 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
114 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
115 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
116 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
117 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES OF NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
118 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
119 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
121 [F] TABLE 415.6.5 DETACHED BUILDING REQUIRED
123 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
128 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
129 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 ARTIFICIAL DECORATIVE VEGETATION
SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
131 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACIILITIES
132 SECTION 423 STORM SHELTERS
133 SECTION 424 PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
134 SECTION 427 MEDICAL GAS SYSTEMS
135 SECTION 428 HIGHER EDUCATION LABORATORIES
[F] TABLE 428.3 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR
138 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
139 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
140 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
141 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa
142 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa
143 SECTION 506 BUILDING AREA
EQUATION 5-1
EQUATION 5-2
EQUATION 5-3
144 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
145 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
146 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
TABLE 506.3.3 FRONTAGE INCREASE FACTORa
TABLE 506.3.3.1 SECTION 507 BUILDINGSa
SECTION 507 UNLIMITED AREA BUILDINGS
149 SECTION 508 MIXED USE AND OCCUPANCY
150 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)f
151 SECTION 509 INCIDENTAL USES
[F] TABLE 509.1 INCIDENTAL USES
152 SECTION 510 SPECIAL PROVISIONS
156 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
158 EQUATION 6-1
160 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
162 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE-USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
163 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
165 SECTION 705 EXTERIOR WALLS
166 TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
167 EQUATION 7-1
TABLE 705.5 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
168 EQUATION 7-2
FIGURE 705.7 EQUIVALENT OPENING FACTOR
169 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
170 SECTION 706 FIRE WALLS
171 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
173 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE-RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
174 SECTION 708 FIRE PARTITIONS
176 SECTION 709 SMOKE BARRIERS
177 SECTION 710 SMOKE PARTITIONS
SECTION 711 FLOOR AND ROOF ASSEMBLIES
178 SECTION 712 VERTICAL OPENINGS
180 SECTION 713 SHAFT ENCLOSURES
181 SECTION 714 PENETRATIONS
184 SECTION 715 JOINTS AND VOIDS
185 SECTION 716 OPENING PROTECTIVES
186 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
187 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
188 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
192 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
193 TABLE 717.3.2.1 FIRE DAMPER RATING
198 SECTION 718 CONCEALED SPACES
200 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
201 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
202 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
203 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
204 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
205 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
206 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
207 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
208 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
209 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
210 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
211 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
212 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
213 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
214 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
215 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
216 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
217 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
218 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
219 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
220 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
221 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
222 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
223 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
224 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
225 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
226 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
227 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R
228 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
229 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
230 EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
231 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
232 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
233 TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
234 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
235 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
TABLE 722.4.1(3) VALUES OF Rn0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
236 EQUATION 7-8
EQUATION 7-9
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
237 EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
238 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(1)—continued W/D RATIOS FOR STEEL COLUMNS
239 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
240 TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
241 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
242 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
243 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
244 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
245 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
246 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1 (6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1 (6)(a)]
247 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
248 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa
249 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-12
EQUATION 7-13
250 EQUATION 7-14
EQUATION 7-15
EQUATION 7-16
251 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
252 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
253 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
254 TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
256 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
258 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
259 SECTION 804 INTERIOR FLOOR FINISH
260 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
261 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
262 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
263 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
265 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
267 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED PROTECTION SYSTEMS
270 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
272 SECTION 905 STANDPIPE SYSTEMS
275 SECTION 906 PORTABLE FIRE EXTINGUISHERS
276 [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
277 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
287 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
288 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
290 EQUATION 9-1
291 EQUATION 9-2
297 SECTION 910 SMOKE AND HEAT REMOVAL
298 EQUATION 9-3
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
300 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
301 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
303 SECTION 916 GAS DETECTION SYSTEMS
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER COMMUNICATION COVERAGE
304 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
305 SECTION 1004 OCCUPANT LOAD
306 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
307 SECTION 1005 MEANS OF EGRESS SIZING
308 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
309 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
310 TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
311 TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1006.3.4(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
312 SECTION 1008 MEANS OF EGRESS ILLUMINATION
313 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
315 SECTION 1010 DOORS, GATES AND TURNSTILES
322 TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING D
323 TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
325 SECTION 1011 STAIRWAYS
329 SECTION 1012 RAMPS
330 SECTION 1013 EXIT SIGNS
331 SECTION 1014 HANDRAILS
332 SECTION 1015 GUARDS
334 SECTION 1016 EXIT ACCESS
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
335 TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
336 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
337 SECTION 1020 CORRIDORS
TABLE 1020.2 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.3 MINIMUM CORRIDOR WIDTH
338 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
339 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
341 SECTION 1024 EXIT PASSAGEWAYS
342 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
343 SECTION 1026 HORIZONTAL EXITS
344 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
345 SECTION 1028 EXIT DISCHARGE
346 SECTION 1029 EGRESS COURTS
SECTION 1030 ASSEMBLY
347 TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
351 TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
353 SECTION 1031 EMERGENCY ESCAPE AND RESCUE
356 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
357 SECTION 1104 ACCESSIBLE ROUTE
358 SECTION 1105 ACCESSIBLE ENTRANCES
TABLE 1105.1.1 PUBLIC ENTRANCE WITH POWER-OPERATED DOORa
359 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.2 ACCESSIBLE PARKING SPACES
360 SECTION 1107 MOTOR-VEHICLE-RELATED FACILITIES
SECTION 1108 DWELLING UNITS AND SLEEPING UNITS
362 TABLE 1108.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
364 SECTION 1109 SPECIAL OCCUPANCIES
TABLE 1109.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
365 TABLE 1109.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
366 TABLE 1109.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION 1110 OTHER FEATURES AND FACILITIES
370 TABLE 1110.13.1 ACCESSIBLE CHECK-OUT AISLES
SECTION 1111 RECREATIONAL FACILITIES
372 TABLE 1111.4.9.1 BOAT SLIPS
SECTION 1112 SIGNAGE
374 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
375 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
377 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
378 SECTION 1206 SOUND TRANSMISSION
SECTION 1207 ENHANCED CLASSROOM ACOUSTICS
SECTION 1208 INTERIOR SPACE DIMENSIONS
379 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
382 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
384 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
385 SECTION 1403 MATERIALS
386 SECTION 1404 INSTALLATION OF WALL COVERINGS
TABLE 1404.3(1) VAPOR RETARDER MATERIALS AND CLASSES
TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
387 TABLE 1404.3(2) VAPOR RETARDER OPTIONS
TABLE 1404.3(3) CLASS III VAPOR RETARDERS
TABLE 1404.3.1 CONTINUOUS INSULATION WITH CLASS II VAPOR RETARDER
392 SECTION 1405 COMBUSTIBLE MATERIALS ONTHE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
393 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
394 SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
395 SECTION 1409 PLASTIC COMPOSITE DECKING
396 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
397 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.2 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161OR D7158
398 TABLE 1504.9 MINIMUM REQUIRED PARAPET HEIGHT (INCHES) FOR AGGREGATE SURFACED ROOFS
SECTION 1505 FIRE CLASSIFICATION
399 TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTIONa
SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
400 TABLE 1507.1.1(1) UNDERLAYMENT TYPES
401 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
402 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
403 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
404 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
405 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
406 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
407 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
408 TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
409 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
410 TABLE 1507.12.2 SINGLE-PLY ROOFING MATERIAL STANDARDS
TABLE 1507.13.3 PROTECTIVE COATING MATERIAL STANDARDS
411 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOF COATINGS
TABLE 1509.2 ROOF COATING MATERIAL STANDARDS
412 SECTION 1510 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1511 ROOFTOP STRUCTURES
414 SECTION 1512 REROOFING
416 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
417 SECTION 1604 GENERAL DESIGN REQUIREMENTS
418 TABLE 1604.3 DEFLECTION LIMITS
420 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
421 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATOIN 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
SECTION 1606 DEAD LOADS
422 SECTION 1607 LIVE LOADS
423 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
424 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
425 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
427 EQUATION 16-7
TABLE 1607.12.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16-8
EQUATION 16-9
428 EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
430 SECTION 1608 SNOW LOADS
SECTION 1609 WIND LOADS
431 TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
432 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
433 FIGURE 1608.2(1) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
434 FIGURE 1608.2(2) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
435 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
436 FIGURE 1609.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
437 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
438 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
439 FIGURE 1609.3(5) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAI
440 FIGURE 1609.3(6) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII (OAHU, KAUAI)
441 FIGURE 1609.3(7) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
442 FIGURE 1609.3(8) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII (OAHU, KAUAI)
443 FIGURE 1609.3(9) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
444 FIGURE 1609.3(10) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII (OAHU, KAUAI)
445 FIGURE 1609.3(11) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
446 FIGURE 1609.3(12) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII (OAHU, KAUAI)
447 EQUATION 16-17
TABLE 1609.3.1 WIND SPEED CONVERSIONS
448 EQUATION 16-18
SECTION 1610 SOIL LOADS AND HYDROSTATIC PRESSURE
SECTION 1611 RAIN LOADS
EQUATION 16-19
449 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1612 FLOOD LOADS
450 FIGURE 1611.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
451 FIGURE 1611.1(2) 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
452 FIGURE 1611.1(3) 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
453 FIGURE 1611.1(4) 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
454 FIGURE 1611.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
455 SECTION 1613 EARTHQUAKE LOADS
456 EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
EQUATION 16-23
457 TABLE 1613.2.3(1) VALUES OF SITE COEFFICIENT Faa
TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT FV
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
458 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
SECTION 1616 STRUCTURAL INTEGRITY
459 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
460 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
461 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
462 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE COTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
463 FIGURE 1613.2.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
464 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
465 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
466 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
467 FIGURE 1613.2.1(9) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
468 FIGURE 1613.2.1(10) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
469 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
EQUATION 16-24
EQUATION 16-25
472 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
473 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
475 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
476 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
477 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
478 TABLE 1705.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
479 TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
481 TABLE 1705.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
484 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
485 SECTION 1709 PRECONSTRUCTION LOAD TESTS
488 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
490 SECTION 1804 EXCAVATION, GRADING AND FILL
491 SECTION 1805 DAMPPROOFING AND WATERPROOFING
493 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
495 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
496 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b,
497 EQUATION 18-1
TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
498 EQUATION 18-2
EQUATION 18-3
TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
499 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c
SECTION 1808 FOUNDATIONS
501 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH fc OF CONCRETE OR GROUT
502 TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
503 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
504 SECTION 1810 DEEP FOUNDATIONS
507 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
508 EQUATION 18-4
510 EQUATION 18-5
516 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 COORDINATION OF TERMINOLOGY
517 SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
520 SECTION 1906 FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907 MINIMUM SLAB PROVISIONS
SECTION 1908 SHOTCRETE
522 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
524 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
525 TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
526 EQUATION 21-1
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
527 EQUATION 21-2
TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
528 SECTION 2110 GLASS UNIT MASONRY
529 SECTION 2111 MASONRY FIREPLACES
531 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
532 SECTION 2113 MASONRY CHIMNEYS
535 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
536 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
538 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
539 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
540 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
541 SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
542 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
546 FIGURE 2303.4.1.2(1) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING ONE ROW OF PITMR
547 FIGURE 2303.4.1.2(2) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF ONE ROW OF PITMR
548 FIGURE 2303.4.1.2(3) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING TWO ROWS OF PITMR
549 FIGURE 2303.4.1.2(4) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF TWO ROWS OF PITMR
550 FIGURE 2303.4.1.2(5) PITMR AND PITMDB FOR FLAT PORTION OF TOP CHORD IN A PIGGYBACK ASSEMBLY
551 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
552 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
553 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
554 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood structural panels are five-ply, five-layer unless otherwise noted)a
555 TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
557 TABLE 2304.10.2 FASTENING SCHEDULE
558 TABLE 2304.10.2—continued FASTENING SCHEDULE
559 TABLE 2304.10.2—continued FASTENING SCHEDULE
560 TABLE 2304.10.2—continued FASTENING SCHEDULE
561 TABLE 2304.10.2—continued FASTENING SCHEDULE
562 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
564 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
565 TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
566 EQUATION 23-2
SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2306.1 STANDARDS FOR DESIGN AND CONSTRUCTION OF WOOD ELEMENTS IN STRUCTURES USING ALLOWABLE STRESS DESIGN
567 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
568 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
FIGURE 2306.2(1) CASES 1 THROUGH 6 FOR USE WITH TABLE 2306.2(1)
569 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
570 FIGURE 2306.2(2) FASTENER SPACING DIAGRAMS FOR USE WITH TABLE 2306.2(2)
571 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
572 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
574 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
575 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
576 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
577 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
578 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
579 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
580 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
582 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
583 TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
584 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
585 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
586 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
587 TABLE 2308.6.1 WALL BRACING REQUIREMENTSa
588 TABLE 2308.6.3(1) BRACING METHODS
589 TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not exposed to the weather, strength axis parallel or perpendicular to studs except as indicated)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING (Not exposed to the weather, long dimension of the panel parallel or perpendicular to studs)
590 TABLE 2308.6.3(5) HARDBOARD SIDING
FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
591 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
593 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
595 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
596 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
598 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)
599 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
600 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
601 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
602 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
603 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
604 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
605 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
606 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
607 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
608 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
609 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
610 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
611 TABLE 2308.7.2(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
612 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
613 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
614 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
615 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
TABLE 2308.7.2(7) RAFTER SPAN ADJUSTMENT FACTOR
616 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSi
617 TABLE 2308.7.3.1(1) HEEL JOINT CONNECTION ADJUSTMENT FACTORS
TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
618 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
620 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
621 EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
622 EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
623 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
624 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
625 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
626 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
628 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
629 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
630 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
631 SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
632 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
633 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
634 SECTION 2514 REINFORCED GYPSUM CONCRETE
636 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
640 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
641 [BS]TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
[BS]TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
642 [BS]TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
643 [BS]TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
644 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
645 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
646 SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
647 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
648 SECTION 2613 FIBER-REINFORCED POLYMER
SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
650 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
652 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
654 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
655 [P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
656 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
657 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
659 [P] 2903 INSTALLATION OF FIXTURES
660 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
661 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
662 SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
663 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
664 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
665 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
668 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
669 SECTION 3103 TEMPORARY STRUCTURES
670 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
671 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
672 SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
673 SECTION 3113 RELOCATABLE BUILDINGS
SECTION 3114 PUBLIC USE RESTROOM BUILDINGS IN FLOOD HAZARD AREAS
674 SECTION 3115 INTERMODAL SHIPPING CONTAINERS
676 TABLE 3115.8.5.3 ALLOWABLE SHEAR VALUES FOR INTERMODAL SHIPPING CONTAINER CORRUGATED STEEL WALLS FOR WIND OR SEISMIC LOADING
677 FIGURE 3115.8.5.3(1) BRACING UNIT DISTRIBUTION—MAXIMUM LINEAR LENGTH
FIGURE 3115.8.5.3(2 )BRACING UNIT DISTRIBUTION—MINIMUM LINEAR LENGTH
678 FIGURE 3115.8.5.3(3) BRACING UNIT DISTRIBUTION—BOUNDARY ELEMENTS
FIGURE 3115.8.5.3(4) BRACING UNIT DISTRIBUTION—PENETRATION LIMITATIONS
680 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
682 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
683 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
684 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
685 SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
686 SECTION 3314 FIRE WATCH DURING CONSTRUCTON
688 CHAPTER 34 RESERVED
690 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
691 AISC
AISI
ALI
AMCA
ANSI
692 APA
693 ASABE
ASCE/SEI
694 ASHRAE
ASME
ASSP
ASTM
706 AWC
AWCI
707 AWPA
AWS
BHMA
CEN
CPA
708 CPSC
CSA
CSSB
DASMA
709 DHA
DOC
DOL
DOTn
EN
FEMA
710 FM
GA
ICC
711 ISO
712 MHI
NAAMM
NCMA
NFPA
715 PCI
PTI
RMI
SBCA
SDI
SJI
716 SPRI
SRCC
TIA
TMS
717 TPI
UL
719 ULC
USC
WCLIB
720 WDMA
WRI
722 APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
SECTION A102 REFERENCED STANDARDS
TABLE A102.1 REFERENCED STANDARDS
724 APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
726 APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
728 APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
729 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
730 SECTION D106 REFERENCED STANDARDS
TABLE D106.1 REFERENCED STANDARDS
732 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
733 TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
734 SECTION E107 SIGNAGE
735 SECTION E108 BUS STOPS
SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
736 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
TABLE E111.1 REFERENCED STANDARDS
738 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
740 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 DEFINITIONS
741 SECTION G103 APPLICABILITY
SECTION G104 POWERS AND DUTIES
742 SECTION G105 PERMITS
SECTION G106 VARIANCES
743 SECTION G107 SUBDIVISIONS
744 SECTION G108 SITE IMPROVEMENT
SECTION G109 MANUFACTURED HOMES
SECTION G110 RECREATIONAL VEHICLES
SECTION G111 TANKS
745 SECTION G112 OTHER BUILDING WORK
SECTION G113 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G114 UTILITY AND MISCELLANEOUS GROUP U
746 SECTION G115 REFERENCED STANDARDS
TABLE G115.1 REFERENCED STANDARDS
748 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
749 SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
750 SECTION H109 GROUND SIGNS
SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
751 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
SECTION H115 THICKNESS OF SIGNS
TABLE H115.1(1) SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE H115.1(2) THICKNESS OF PROJECTION SIGN
SECTION H116 REFERENCED STANDARDS
TABLE H116.1 REFERENCED STANDARDS
752 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
754 APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
755 SECTION J104 PERMIT APPLICATION AND SUBMITTALS
SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
756 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
757 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
TABLE J111.1 REFERENCED STANDARDS
758 APPENDIX K ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
759 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
760 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
762 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
764 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M101 REFUGE STRUCTURES FOR VERTICAL EVACUATION FROM TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M102 REFERENCED STANDARDS
TABLE M102.1 REFERENCED STANDARDS
766 APPENDIX N REPLICABLE BUILDINGS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
767 SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
768 [A] APPENDIX O PERFORMANCE-BASED APPLICATION
[A] SECTION O101 GENERAL
770 INDEX
810 RESOURCE A RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI)
812 RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI)
813 COPYRIGHT
814 TABLE OF CONTENTS
816 PREFACE
817 ABOUT THE INTERNATIONAL CODE COUNCIL
818 1.0 INTRODUCTION
PURPOSE AND SCOPE
2.0 DEFINITIONS AND ACRONYMS
3.0 REMOTE VIRTUAL INSPECTION PROCESS
819 CUSTOMER: REQUESTING A REMOTE VIRTUAL INSPECTION
820 AHJ: SCHEDULING REMOTE VIRTUAL INSPECTION
821 CUSTOMER: PREPARE FOR REMOTE VIRTUAL INSPECTION
CUSTOMER: PREPARE TO RECEIVE REMOTE VIRTUAL INSPECTION CALL
822 WHAT TO EXPECT DURING THE INSPECTION
INSPECTION RESULTS
823 MAINTAINING RECORDS OF INSPECTIONS
4.0 TRAINING AND COMMUNICATION
STAFF TRAINING
824 CUSTOMER/APPLICANT
ADDITIONAL CONSIDERATIONS
825 5.0 APPENDIX A (EXAMPLES OF POTENTIAL ACTIVITIES)
826 KEYS TO SUCCESS FOR REMOTE VIRTUAL INSPECTIONS
WHAT ARE REMOTE VIRTUAL INSPECTIONS (RVI)?
RVI BENEFITS
THE FOUNDATION OF SUCCESS: TRAINING AND COMMUNICATION
827 THE KEY STEPS TO A REMOTE VIRTUAL INSPECTION
828 ICC DIGITAL CODES LIBRARY
829 RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI) BACK COVER
830 VALUABLE GUIDES TO CHANGES IN THE 2021 I-CODES
831 ICC EVALUATION SERVICE
832 S.K. GHOSH ASSOCIATES
833 TELEWORK WITH ICC DIGITAL CODES PREMIUM
ICC IBC 2021 1stptg
$82.08