Shopping Cart

No products in the cart.

ICC IBC Commentary BothVolumes 2012

$157.08

IBC Code and Commentary Combo, Vol. 1 & 2

Published By Publication Date Number of Pages
ICC 2012 1928
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This bundle includes both Volume 1 and Volume 2 of the 2012 International Building Code Commentary. Volume 1 contains chapters 1 through 15 (administrative and fire & life safety provisions) and Volume 2 contains chapters 16 through 35 (includes structural provisions) and the appendices. This comprehensive yet concise publication provides a convenient reference for regulations of the 2012 International Building Code

PDF Catalog

PDF Pages PDF Title
1 2012 INTERNATIONAL BUILDING CODE AND COMMENTARY VOLUME I
2 2012 IBC CODE AND COMMENTARY VOLUME 1 TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 CHAPTER 1: SCOPE AND ADMINISTRATION
PART 1 SCOPE AND APPLICATION
9 SECTION 101 GENERAL
11 SECTION 102 APPLICABILITY
12 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
16 SECTION 105 PERMITS
19 SECTION 106 FLOOR AND ROOF DESIGN LOADS
20 SECTION 107 SUBMITTAL DOCUMENTS
23 SECTION 108 TEMPORARY STRUCTURES AND USES
24 SECTION 109 FEES
25 SECTION 110 INSPECTIONS
27 SECTION 111 CERTIFICATE OF OCCUPANCY
28 SECTION 112 SERVICE UTILITIES
29 SECTION 113 BOARD OF APPEALS
30 SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
31 SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
BIBLIOGRAPHY
34 CHAPTER 2: DEFINITIONS
SECTION 201 GENERAL
35 SECTION 202 DEFINITIONS
38 FIGURE 202.1(1) AISLES AND AISLE ACCESSWAYS
39 FIGURE 202.1(2) ANCHOR BOLTS
FIGURE 202.1(3) MASONRY/FLOOR ANCHOR BOLT CONNECTOR
40 FIGURE 202.1(4) COVERED MALL BUILDING
41 FIGURE 202.1(5) EXAMPLE OF ANNULAR SPACE
42 FIGURE 202.1(7) BUILDING AREA—PROJECTED
FIGURE 202.1(6) GROSS CROSS-SECTIONAL AREA FOR SINGLE WYTHE WALL UNDER LOAD
46 FIGURE 202.2(1) STORY ABOVE GRADE
47 FIGURE 202.2(2) MASONRY CONSTRUCTION TERMS
48 FIGURE 202.2(3) GROUP R-2—BOARDING HOUSE (OCCUPANTS PRIMARILY NONTRANSIENT)
62 FIGURE 202.4(1) SPECIFIED AND NOMINAL DIMENSIONS FOR NOMINAL 8 × 8 × 16 CONCRETE MASONRY UNITS
FIGURE 202.4(2) BALANCED DOOR
63 FIGURE 202.4(3) GROUP R-2—DORMITORY
FIGURE 202.4(4) EXAMPLE OF DRAFTSTOPPING
64 FIGURE 202.4(5) EXAMPLE OF DRAFTSTOPPING
67 FIGURE 202.5(1) EXIT
68 FIGURE 202.5(2) EXIT ACCESS
FIGURE 202.5(3) EXIT DISCHARGE
69 FIGURE 202.5(4) EXIT DISCHARGE, LEVEL OF
70 FIGURE 202.5(5) EXIT HORIZONTAL
74 FIGURE 202.6(1) EXAMPLE OF FIRE BARRIER
76 FIGURE 202.6(2) EXAMPLES OF FIRE-RESISTANT JOINT SYSTEMS
77 FIGURE 202.6(3) FIRE SEPARATION DISTANCE MEASURED TO AN INTERIOR LOT LINE
FIGURE 202.6(4) FIRE SEPARATION DISTANCE MEASURED TO AN INTERIOR LOT LINE
78 FIGURE 202.6(5) FIRE SEPARATION DISTANCE MEASURED TO AN IMAGINARY LINE BETWEEN TWO BUILDINGS ON THE SAME LOT
84 FIGURE 202.7(1) DETERMINATION OF GRADE PLANE ELEVATION WHERE GRADE SLOPES UNIFORMLY ALONG THE ENTIRE LENGTH OF THE EXTERIOR WALLS
85 FIGURE 202.7(2) DETERMINATION OF GRADE PLANE ELEVATIONS WHERE GRADE AND EXTERIOR WALLS ARE IRREGULAR
FIGURE 202.7(3) DETERMINATION OF GRADE PLANE WHERE GRADE SLOPES AWAY FROM THE EXTERIOR WALL
86 FIGURE 202.7(4) DETERMINATION OF GRADE PLANE ELEVATION WHERE GRADE DOES NOT SLOPE UNIFORMLY ALONG THE LENGTH OF THE EXTERIOR WALLS
89 FIGURE 202.8(1) BUILDING HEIGHT
90 FIGURE 202.8(2) HIGH-RISE BUILDING
91 FIGURE 202.8(3) EXAMPLES OF HORIZONTAL ASSEMBLIES
101 FIGURE 202.13(1) EXAMPLES OF SINGLE MEMBRANE PENETRATION
113 FIGURE 202.18(1) RUNNING BOND MASONRY
118 FIGURE 202.19(1) SMOKE BARRIER
128 FIGURE 202.20(1) EXAMPLES OF THROUGH-PENETRATION FIRESTOP SYSTEMS
137 BIBLIOGRAPHY
140 CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
141 SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
142 FIGURE 302.1 GROUP CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
143 FIGURE 303.1.2(1) ACCESSORY ASSEMBLY USE LIMITED BY OCCUPANT LOAD
FIGURE 303.1.2(2) ACCESSORY ASSEMBLY USE GREATER THAN 10% OF FLOOR AREA BUT LESS THAN 750 SQ. FT.
144 FIGURE 303.2(1) GROUP A-1
145 FIGURE 303.2(2) GROUP A-1
FIGURE 303.3 GROUP A-2
147 SECTION 304 BUSINESS GROUP B
148 SECTION 305 EDUCATIONAL GROUP E
149 SECTION 306 FACTORY GROUP F
151 SECTION 307 HIGH-HAZARD GROUP H
156 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
157 TABLE 307.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
158 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
161 SECTION 308 INSTITUTIONAL GROUP I
163 FIGURE 308.4(1) GROUP I-2—HOSPITAL
FIGURE 308.4(2) GROUP I-2—NURSING HOME
164 FIGURE 308.5 GROUP I-3—OCCUPANCY CONDITIONS
165 FIGURE 308.5.1 CONDITION 1
166 FIGURE 308.5.2 CONDITION 2
FIGURE 308.5.3 CONDITION 3
167 FIGURE 308.5.4 CONDITION 4
168 FIGURE 308.5.5 CONDITION 5
169 SECTION 309 MERCANTILE GROUP M
170 FIGURE 309.1(1) GROUP M—DEPARTMENT STORE
FIGURE 309.1(2) GROUP M—SELF-SERVICE GAS STATION(NO CAR REPAIR IS DONE)
171 SECTION 310 RESIDENTIAL GROUP R
172 FIGURE 310.3 GROUP R-1—HOTEL
173 FIGURE 310.4(1) GROUP R-2—APARTMENTS (OCCUPANTS PRIMARILY NONTRANSIENT)
174 FIGURE 310.4(2) GROUP R-2—DORMITORY (OCCUPANTS PRIMARILY NONTRANSIENT)
175 FIGURE 310.5(1) GROUP R-3—MIXED OCCUPANCY BUILDING
176 FIGURE 310.5(2) GROUP R-3—MIXED OCCUPANCY BUILDING
SECTION 311 STORAGE GROUP S
177 FIGURE 311.2 GROUP S-1—REPAIR GARAGES
178 FIGURE 311.3 GROUP S-2—ENCLOSED PARKING GARAGE
179 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
BIBLIOGRAPHY
182 CHAPTER 4: SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
183 FIGURE 402.1 COVERED MALL BUILDING
185 FIGURE 402.1.2 OPEN MALL PERIMETER
187 FIGURE 402.4 TENANT SPACE AND ANCHOR BUILDING SEPARATIONS
189 FIGURE 402.4.3 MINIMUM WIDTH OF OPEN MALL
192 FIGURE 402.6.4 STOREFRONT SIGNAGE WITH PLASTIC SIGNS
194 FIGURE 402.8 MEANS OF EGRESS
195 EQUATION 4-1
FIGURE 402.8.1.1 COVERED MALL MINIMUM WIDTH
198 SECTION 403 HIGH-RISE BUILDINGS
199 FIGURE 403.1(1) HIGH-RISE BUILDING
200 FIGURE 403.1(2) HIGH-RISE BUILDINGS—STACK EFFECT
201 FIGURE 403.1(3) HIGH-RISE BUILDINGS—EVACUATION TIMES
203 TABLE 403.2.4 MINIMUM BOND STRENGTH
208 FIGURE 403.5.1 HIGH-RISE BUILDINGS: REMOTENESS OF EXIT STAIRWAYS
211 FIGURE403.6.1 HIGH-RISE BUILDINGS: FIRE SERVICE ACCESS ELEVATORS
212 SECTION 404 ATRIUMS
215 FIGURE 404.6(1) ENCLOSURE OF ATRIUMS (EXCEPTION 1)
FIGURE 404.6(2) ENCLOSURE OF ATRIUMS (EXCEPTION 3)
216 SECTION 405 UNDERGROUND BUILDINGS
217 FIGURE 405.1 EXAMPLES OF UNDERGROUND BUILDINGS
219 FIGURE 405.4 EXAMPLE OF COMPARTMENTATION, ELEVATOR PROTECTION AND EGRESS OF AN UNDERGROUND BUILDING
220 FIGURE 405.4.1 EXAMPLE OF HORIZONTAL COMPARTMENTATION
222 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
228 FIGURE 406.5.2 TWO-STORY OPEN PARKING GARAGE
229 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
233 SECTION 407 GROUP I-2
235 FIGURE 407.2.1 GROUP I-2: WAITING ROOMS AND SIMILAR AREAS
FIGURE 407.2.2 GROUP I-2: CARE PROVIDERS’ STATION
237 FIGURE 407.3 GROUP I-2: CORRIDOR WALLS
238 FIGURE 407.4.3 GROUP I-2 EXAMPLE OF SUITE
239 FIGURE 407.4.3.5.3 MEANS OF EGRESS TRAVEL IN SUITES WITH GROUP I-2 PATIENT SLEEPING ROOMS
241 FIGURE 407.5 GROUP I-2: SMOKE BARRIER
242 FIGURE 407.5.2(1) ACCEPTABLE EGRESS ARRANGEMENT
243 FIGURE 407.5.2(2) UNACCEPTABLE EGRESS ARRANGEMENT
244 SECTION 408 GROUP I-3
245 FIGURE 408.1 GROUP I-3: OCCUPANCY CONDITIONS
249 FIGURE 408.4.1 GROUP I-3: MANUAL RELEASE
250 FIGURE 408.5(1) GROUP I-3: VERTICAL OPENINGS
251 FIGURE 408.5(2) GROUP I-3: VERTICAL OPENINGS
252 FIGURE 408.6.1 GROUP I-3: SMOKE COMPARTMENTS
253 FIGURE 408.6.2 GROUP I-3: REFUGE AREA
254 SECTION 409 MOTION PICTURE PROJECTION ROOMS
256 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
262 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
264 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
265 TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
269 TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
272 SECTION 413 COMBUSTIBLE STORAGE
273 SECTION 414 HAZARDOUS MATERIALS
274 FIGURE 414.2 CONTROL AREAS
275 TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
276 FIGURE 414.2.2 CONTROL AREAS
278 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
279 TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
281 TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
284 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
286 TABLE 415.5.2 DETACHED BUILDING REQUIRED
293 TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
297 FIGURE 415.10.2 ALLOWABLE HPM CORRIDOR ARRANGEMENTS
304 FIGURE 415.10.11.1 CROSS-SECTIONAL DIAMETERS OF VARIOUS-SHAPED DUCTS
305 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
306 SECTION 417 DRYING ROOMS
307 SECTION 418 ORGANIC COATINGS
308 SECTION 419 LIVE/WORK UNITS
311 SECTION 420 GROUPS I-1, R-1, R-2, R-3
SECTION 421 HYDROGEN CUTOFF ROOMS
314 SECTION 422 AMBULATORY CARE FACIILITIES
315 SECTION 423 STORM SHELTERS
316 SECTION 424 CHILDREN’S PLAY STRUCTURES
317 BIBLIOGRAPHY
320 CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
321 SECTION 501 GENERAL
SECTION 502 DEFINITIONS
322 SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
FIGURE 503.1 MINIMUM CONSTRUCTION TYPE IN ACCORDANCE WITH TABLE 503
324 TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS
325 TABLE 503—continued ALLOWABLE BUILDING HEIGHTS AND AREAS
326 FIGURE 503.1.2 (1) BUILDINGS ON SAME LOT
327 FIGURE 503.1.2(2) TWO BUILDINGS ON SAME LOT CREATED BY FIRE WALL
SECTION 504 BUILDING HEIGHT
329 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
332 SECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
333 EQUATION 5-2
334 FIGURE 506.2(1) FRONTAGE INCREASE—FIRE WALL
FIGURE 506.2(2) FRONTAGE INCREASE
EQUATION 5-3
335 FIGURE 506.2.1(1) FRONTAGE INCREASE—THREE SIDES
FIGURE 506.2.1(2) FRONTAGE INCREASE—FOUR SIDES
336 FIGURE 506.2.2(1) ACCESS TO OPEN SPACE
FIGURE 506.2.2(2) ACCESS TO OPEN SPACE
341 SECTION 507 UNLIMITED AREA BUILDINGS
342 FIGURE 507.1 REQUIRED SEPARATION FOR UNLIMITED AREA BUILDINGS
346 FIGURE 507.8.1.1 USE GROUP H-2 NOT LOCATED AT THE PERIMETER OF AN UNLIMITED AREA BUILDING
347 FIGURE 507.8.2(1) GROUP H-2 AT THE CORNER OF AN UNLIMITED AREA BUILDING
FIGURE 507.8.2(2) GROUP H-2 AT THE CORNER OF AN UNLIMITED AREA BUILDING
349 SECTION 508 MIXED USE AND OCCUPANCY
350 FIGURE 508.2.1(1) ACCESSORY USES LIMITED BY FLOOR AREA
FIGURE 508.2.1(2) ACCESSORY USES LIMITED BY TABULAR AREA
352 FIGURE 508.3 NONSEPARATED USES
357 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
358 FIGURE 508.4(1) SEPARATED OCCUPANCIES—EXAMPLE 1
359 FIGURE 508.4(2) SEPARATED OCCUPANCIES—EXAMPLE 1: LOCATION ON STORIES
360 FIGURE 508.4(3) SEPARATED OCCUPANCIES—EXAMPLE 2
361 FIGURE 508.4(4) SEPARATED OCCUPANCIES—EXAMPLE 3
362 SECTION 509 INCIDENTAL USES
363 TABLE 509 INCIDENTAL USES
SECTION 510 SPECIAL PROVISIONS
365 FIGURE 510.2 HORIZONTAL BUILDING SEPARATION
367 FIGURE 510.4 EXAMPLE R-1 OVER ENCLOSED PARKING
368 FIGURE 510.5 EXAMPLE TYPE IIIA, GROUP R-2 HEIGHT INCREASE
369 FIGURE 510.6 EXAMPLE TYPE IIIA, GROUP R-2 HEIGHT INCREASE
370 FIGURE 510.7 OPEN PARKING BELOW OTHER GROUPS
372 FIGURE 510.8 EXAMPLES S-2 PARKING OVER GROUP B AND M OCCUPANCIES
FIGURE 510.9 MULTIPLE SEPARATE BUILDINGS
BIBLIOGRAPHY
374 CHAPTER 6: TYPES OF CONSTRUCTION
SECTION 601 GENERAL
375 TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
377 FIGURE 601(1) PROTECTION OF SECONDARY MEMBERS
FIGURE 601(2) PROTECTION OF ROOF CONSTRUCTION
378 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
379 FIGURE 602(1) DETERMINING FIRE SEPARATION DISTANCE
FIGURE 602(2) DETERMINING FIRE SEPARATION DISTANCE FOR MULTISTORY BUILDINGS
380 SECTION 602 CONSTRUCTION CLASSIFICATION
381 FIGURE 602.2 EXAMPLES OF TYPE I AND II CONSTRUCTION
382 FIGURE 602.3 EXAMPLE OF TYPE III CONSTRUCTION
TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES
383 FIGURE 602.4.1(1) HEAVY TIMBER—FLOOR BEAM AND COLUMN FRAMING
384 FIGURE 602.4.1(2) COLUMN/FLOOR BEAM CONNECTIONS
385 FIGURE 602.4.3(1) SPACED MEMBERS WITH COVER PLATE
FIGURE 602.4.3(2) SOLID BLOCKING OF SPACED MEMBERS
386 FIGURE 602.4.4(1) CONCEALED SPACES
387 FIGURE 602.4.4(2) HEAVY TIMBER FLOORING
388 FIGURE 602.5 EXAMPLE OF TYPE V CONSTRUCTION
SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
390 BIBLIOGRAPHY
392 CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
393 SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
394 FIGURE 703.2 STANDARD TIME-TEMPERATURE CURVE
399 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
400 FIGURE 704.2 COLUMN PROTECTION
FIGURE 704.3 INDIVIDUAL FIRE PROTECTION METHOD
401 FIGURE 704.4 MEMBRANE FIRE PROTECTION METHOD
404 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
406 FIGURE 705.2 PROJECTIONS FROM EXTERIOR WALLS
408 FIGURE 705.6 TYPE IIB AND VB EXTERIOR FIRE-RESISTANCE-RATED WALL CONTINUITY AND STRUCTURAL STABILITY
EQUATION 7-1
409 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EXAMPLE 705.7 ELEVATION OF EXTERIOR WALL
411 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
412 FIGURE 705.8.1 EXAMPLES OF PERMITTED UNLIMITED OPENING AREA IN THE FIRST STORY
EQUATION 7-2
413 FIGURE 705.8.5(1) EXTERIOR WALL VERTICAL FLAME BARRIER
414 FIGURE 705.8.5(2) EXTERIOR WALL HORIZONTAL FLAME BARRIER
415 FIGURE 705.8.6 VERTICAL FIRE EXPOSURE OF ADJACENT BUILDING
417 SECTION 706 FIRE WALLS
418 FIGURE 705.11.1(1) PARAPET WALL EXTENSION WITH SLOPING 100% NONSPRINKLERED BUILDING
FIGURE 705.11.1(2) PARAPET WALL EXTENSION WITH SLOPING ROOF SPRINKLERED BUILDING
419 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
420 FIGURE 706.2(1) DETAILS OF MASONRY FIRE WALL FOR STABILITY
421 FIGURE 706.2(2) DETAILS OF GYPSUM BOARD AREA SEPARATION WALLS (FIREWALL)
422 FIGURE 706.4(1) RELATIONSHIP BETWEENFUEL LOAD AND FIRE ENDURANCE
FIGURE 706.4(2) OCCUPANCIES—FUEL LOAD—FIRE SEVERITY
424 FIGURE 706.5.1(1) EXAMPLE OF METHOD 1
425 FIGURE 706.5.1(2) EXAMPLE OF METHOD 2
426 FIGURE 706.5.1(3) EXAMPLE OF METHOD 2
427 FIGURE 706.6 GENERIC FIRE WALL EXAMPLE
428 FIGURE 706.6.1(1) FIRE WALLS—STEPPED BUILDINGS
429 FIGURE 706.6.1(2) FIRE WALLS—STEPPED BUILDINGS
FIGURE 706.6.1(3) FIRE WALLS—EXTENSION EXCEPTION
430 FIGURE 706.6.2 FIRE WALL EXTENSION AT SLOPING ROOF > 2:12
431 SECTION 707 FIRE BARRIERS
432 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
433 FIGURE 707.5 CONTINUITY OF FIRE BARRIERS
436 SECTION 708 FIRE PARTITIONS
437 FIGURE 708.4(1) CONTINUITY OF FIRE PARTITIONS
438 FIGURE 708.4 (2)(A) FIRE PARTITION CONTINUITY
439 FIGURE 708.4(2)(B) FIRE PARTITION CONTINUITY
440 FIGURE 708.4(2)(C) FIRE PARTITION CONTINUITY
441 SECTION 709 SMOKE BARRIERS
443 FIGURE 709.5 ACCEPTABLE MEETING EDGES OF DOUBLE MEANS OF EGRESS DOORS
SECTION 710 SMOKE PARTITIONS
445 SECTION 711 HORIZONTAL ASSEMBLIES
446 FIGURE 711.3.1 CEILING PANELS USED IN FIRE-RESISTANCE-RATED ASSEMBLIES
447 FIGURE 711.3.3(1) UNUSABLE SPACE ABOVE A FIRE-RESISTANCE-RATED ASSEMBLY
448 FIGURE 711.3.3(2) UNUSABLE SPACE BELOW A FIRE-RESISTANCE-RATED ASSEMBLY
FIGURE 711.4(1) CONTINUITY OF FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
449 FIGURE 711.4(2) PIPE PENETRATION OF FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
450 SECTION 712 VERTICAL OPENINGS
451 FIGURE 712.1.3.1 SHAFT ENCLOSURE—DRAFT CURTAIN EXCEPTION
452 FIGURE 712.1.3.2 SHAFT ENCLOSURE—SHUTTERS EXCEPTION
453 FIGURE 712.1.8 TWO-STORY SHAFT ENCLOSURE EXCEPTION
454 SECTION 713 SHAFT ENCLOSURES
455 FIGURE 713.4 VERTICAL SHAFTS—FIRE-RESISTANCE RATING
456 FIGURE 713.7 PROTECTED OPENING IN SHAFT ENCLOSURE
457 FIGURE 713.11(1) VERTICAL SHAFTS—BOTTOM ENCLOSURES METHOD 1
FIGURE 713.11(2) VERTICAL SHAFTS—BOTTOM ENCLOSURE ROOM METHOD 2
FIGURE 713.11(2) VERTICAL SHAFTS—BOTTOM ENCLOSURE ROOM METHOD 2
458 FIGURE 713.11(3) VERTICAL SHAFTS—BOTTOM ENCLOSURE ROOM METHOD 2—EXCEPTION 1
FIGURE 713.11(4) VERTICAL SHAFTS—BOTTOM ENCLOSURE WITH SPRINKLERS—METHOD 2—EXCEPTION 1
459 FIGURE 713.11(5) VERTICAL SHAFTS—BOTTOM ENCLOSURE EXCEPTION 3
460 FIGURE 713.12 VERTICAL SHAFTS—TOP ENCLOSURE AT FLOOR
461 FIGURE 713.13.3 REFUSE CHUTE (FIRE BARRIER OPTION)
464 SECTION 714 PENETRATIONS
466 FIGURE 714.3.1(1) VERTICAL SHAFTS—COMBUSTIBLE PENETRATIONS
FIGURE 714.3.1(2) COMBUSTIBLE PIPE PENETRATION OF FIRE-RESISTANCE-RATED WALL
467 FIGURE 714.3.1(3) EXAMPLES OF ANNULAR SPACE PROTECTION
470 FIGURE 714.3.2(1) OUTLET BOXES IN RATED ASSEMBLIES
471 FIGURE 714.3.2(2) EXCEPTION TO ANNULAR SPACE PROTECTION
472 FIGURE 714.4.1(1) NONCOMBUSTIBLE PENETRATION OF A FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
473 FIGURE 714.4.1(2) EXAMPLES OF ANNULAR SPACE PROTECTION WITH SLEEVES
474 FIGURE 714.4.1.1.2 EXAMPLE OF CABLING THROUGH-PENETRATION FIRESTOP SYSTEM
475 FIGURE 714.4.1.2(1) PROTECTION OF PENETRATIONS THROUGH CEILING MEMBRANE OF FIRE-RESISTANCE-RATED ASSEMBLY
FIGURE 714.4.1.2(2) NONCOMBUSTIBLE PIPE PENETRATIONS OF CEILING MEMBRANE OF AFIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
478 FIGURE 714.4.2.1 NONCOMBUSTIBLE PIPE PENETRATIONS OF NONFIRE-RESISTANCE-RATED ASSEMBLIES
SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
479 FIGURE 715.1 EXAMPLES OF JOINT LOCATIONS
482 FIGURE 715.4 EXTERIOR CURTAIN WALL/FLOOR INTERSECTION
483 SECTION 716 OPENING PROTECTIVES
TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
484 FIGURE 716.3(1) FIRE-RATED GLAZING LOCATIONS
TABLE 716.3(1) MARKINGS OF FIRE RATED GLAZING
487 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
488 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
493 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
495 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
498 TABLE 717.3.2.1 FIRE DAMPER RATING
500 FIGURE 717.5 FIRE DAMPERS IN RATED WALL
502 FIGURE 717.5.3.1(1) FIRE DAMPERS—EXCEPTION 1
FIGURE 717.5.3.1(2) FIRE DAMPERS—EXCEPTION 1.4
504 FIGURE 717.5.4(1) FIRE DAMPERS—EXCEPTION 1
FIGURE 717.5.4(2) FIRE DAMPERS—EXCEPTION 2
506 FIGURE 717.6.1(1) AIR DUCT PENETRATION OF A FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
FIGURE 717.6.1(2) AIR DUCT PENETRATION OF A FIRE-RESISTANCE-RATED ROOF ASSEMBLY
508 FIGURE 717.6.3(1) DUCT PENETRATIONS OF NONFIRE-RESISTANCE-RATED ASSEMBLIES
509 FIGURE 717.6.3(2) FIRE DAMPERS IN DUCTS PENETRATING NONFIRE-RESISTANCE-RATED ASSEMBLIES
SECTION 718 CONCEALED SPACES
511 FIGURE 718.2.3(1) FIREBLOCKING—SOFFITS
512 FIGURE 718.2.3(2) FIREBLOCKING—DROP CEILINGS
FIGURE 718.2.3(3) FIREBLOCKING—COVE CEILING
513 FIGURE 718.2.4 FIREBLOCKING—STAIRS
514 FIGURE 718.2.7 FIREBLOCKING—CONCEALED FLOOR SPACES
515 FIGURE 718.3.2 DRAFTSTOPPING—GROUPS R-1, R-2, R-3 AND R-4 AT TENANT AND DWELLING UNIT SEPARATIONS
516 FIGURE 718.3.3 DRAFTSTOPPING—CONCEALED FLOOR SPACES, OTHER GROUP
517 FIGURE 718.4.2(1) DRAFTSTOPPING AT TENANT AND DWELLING UNIT SEPARATIONS
518 FIGURE 718.4.2(2) DRAFTSTOPPING IN LINE WITH TENANT AND DWELLING UNIT SEPARATION WALLS
519 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
520 FIGURE 720.2 CONCEALED INSULATION
521 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
522 FIGURE 721.1.1 (1) STEEL COLUMN ENCASED IN CONCRETE
523 FIGURE 721.1.1(2) REINFORCING STEEL IN CONCRETE COLUMNS, BEAMS, GIRDERS AND TRUSSES
524 FIGURE 721.1(2) (a) CONCRETE WALL
FIGURE 721.1(2) (b) METAL STUD WALL WITH PLASTER
525 FIGURE 721.1(3) WOOD FLOOR TRUSS
526 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
527 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
528 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
529 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
530 TABLE 721.1(2)RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
531 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
532 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
533 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
534 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
535 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
536 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
537 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
538 TABLE 721.1(2)—continuedRATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa
539 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
540 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
541 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
542 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
543 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
544 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa
545 TABLE 721.1(3)—continuedMINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
546 TABLE 721.1(3)—continuedMINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
547 TABLE 721.1(3)—continuedMINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
548 TABLE 721.1(3)—continuedMINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
SECTION 722 CALCULATED FIRE RESISTANCE
550 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
551 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
552 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
553 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
554 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
555 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
556 EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
557 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
558 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
559 TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
560 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
561 EQUATION 7-6
562 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
563 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
564 EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
565 EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
566 TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
567 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
568 FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
569 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
EQUATION 7-13
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1.2.1 EXAMPLE—STEEL COLUMN PROTECTED WITH WALLBOARD
571 EQUATION 7-14
FIGURE 722.5.1.3 EXAMPLE—SPRAY-APPLIED MATERIALS, FIRE ENDURANCE TEST DATA
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
572 EQUATION 7-15
EQUATION 7-16
573 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
574 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
575 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
576 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
577 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
578 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
579 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
580 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
581 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE722.5.1(6)(c)]
582 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
583 EQUATION 7-17
584 FIGURE 722.6 EXAMPLE—WOOD STUD WALL WITH WALLBOARD
TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
585 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
586 EQUATION 7-18
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
587 FIGURE 722.6.3(1) LOAD FIGURE
FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS
BIBLIOGRAPHY
590 CHAPTER 8: INTERIOR FINISHES
SECTION 801 GENERAL
591 SECTION 802 DEFINITIONS
592 SECTION 803 WALL AND CEILING FINISHES
FIGURE 803.1(1) ASTM E 84 TUNNEL TEST
FIGURE 803.1(2) FLAME IN TUNNEL TEST
593 TABLE 803.1(3) TYPICAL FLAME SPREAD OF COMMON MATERIALS
FIGURE 803.1.2(1) ROOM CORNER TEST
594 FIGURE 803.1.2(2) FLAME IN ROOM CORNER TEST
597 TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
598 FIGURE 803.11.2 SET-OUT CONSTRUCTION
599 FIGURE 803.11.4 THIN INTERIOR FINISHES
600 SECTION 804 INTERIOR FLOOR FINISH
FIGURE 804.2 RADIANT FLOOR PANEL TEST (NFPA 253)
601 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
602 SECTION 806 DECORATIVE MATERIALS AND TRIM
604 FIGURE 806.5(1) TRIM COVERAGE AREA
FIGURE 806.5(2) MAXIMUM DIMENSION—FOAM PLASTIC TRIM
SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
605 BIBLIOGRAPHY
608 CHAPTER 9: FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
611 SECTION 902 DEFINITIONS
612 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
613 FIGURE 903.2 SUMMARY OF OCCUPANCY-RELATED AUTOMATIC SPRINKLER THRESHOLDS
618 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
624 FIGURE 903.2.11.1 SPACING OF OPENINGS IN STORIES OR BASEMENTS
625 FIGURE 903.2.11.1(1) OPENINGS IN STORIES OR BASEMENTS—LESS THAN 75 FEET FROM ANY POINT TO AN OPENING
FIGURE 903.2.11.1(2) OPENINGS IN STORIES OR BASEMENTS—MORE THAN 75 FEET FROM ANY POINT TO AN OPENING
FIGURE 903.2.11.1(3) OPENINGS IN STORIES OR BASEMENTS—LESS THAN 75 FEET FROM ANY POINT TO AN OPENING
FIGURE 903.2.11.1(4) OPENINGS IN STORIES OR BASEMENTS
627 TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
628 FIGURE 903.3.1 NFPA 13, NFPA 13R, NFPA 13D SYSTEMS
FIGURE 903.3.1.1 TYPICAL WET PIPE SYSTEM
629 FIGURE 903.3 SAMPLE SPRINKLER SYSTEM DRAWING AND DATA SUBMITTALS
637 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
644 SECTION 905 STANDPIPE SYSTEMS
645 FIGURE 905.3.1(1) HEIGHT THRESHOLD FOR STANDPIPES
646 FIGURE 905.3.1(2) HEIGHT REQUIREMENTS FOR STANDPIPES WITH MULTIPLE LEVELS OF FIRE DEPARTMENT VEHICLE ACCESS
652 SECTION 906 PORTABLE FIRE EXTINGUISHERS
654 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
655 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
657 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
659 FIGURE 907.2 SUMMARY OF MANUAL FIRE ALARM AND AUTOMATIC SMOKE DETECTION SYSTEM THRESHOLDS
672 FIGURE 907.2.11.2 LOCATION OF SMOKE ALARMS IN A DWELLING UNIT
684 TABLE 907.5.2.3.3 VISIBLE ALARMS
687 SECTION 908 EMERGENCY ALARM SYSTEMS
691 SECTION 909 SMOKE CONTROL SYSTEMS
694 FIGURE 909.4.1 STACK EFFECT
698 EQUATION 9-1
EQUATION 9-2
699 FIGURE 909.8(1) SMOKE LAYER INTERFACE IN AN ATRIUM
701 FIGURE 909.8(2) AXISYMMETRICAL PLUM
FIGURE 909.8(3) BALCONY SPILL PLUME
702 FIGURE 909.8(4) WINDOW PLUME
FIGURE 909.8(5) PLUGHOLING
703 FIGURE 909.8.1(1) EXAMPLE, CRITICAL LEVEL OF SMOKE
704 FIGURE 909.8.1(2) SMOKE LAYER INTERFACE
706 EQUATION 9-3
715 FIGURE 909.20.1 DIMENSIONAL REQUIREMENTS FOR SMOKEPROOF ENCLOSURE VESTIBULE
716 FIGURE 909.20.3.2 SMOKEPROOF ENCLOSURE WITH OPEN VESTIBULE ARRANGEMENT
717 FIGURE 909.20.4.1 SMOKEPROOF ENCLOSURE WITH CORRIDOR ARRANGEMENT
718 FIGURE 909.20.4.2 MECHANICALLY VENTILATED VESTIBULE
721 SECTION 910 SMOKE AND HEAT REMOVAL
722 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTS
724 FIGURE 910.3.4 SMOKE AND HEAT VENT SPACING
725 EQUATION 9-4
727 SECTION 911 FIRE COMMAND CENTER
729 SECTION 912 FIRE DEPARTMENT CONNECTIONS
730 FIGURE 912.3.1 LOCKING FDC CAPS
731 FIGURE 912.4 FIRE DEPARTMENT CONNECTION WITH SIGN
SECTION 913 FIRE PUMPS
733 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
FIGURE 914.1.1 SHAFTWAY SIGNAGE
SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE
734 BIBLIOGRAPHY
736 CHAPTER 10: MEANS OF EGRESS
737 SECTION 1001 ADMINISTRATION
738 SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS
740 FIGURE 1003.3.1(1) DOOR CLOSER HEADROOM PROTRUSIONS FOR WALKING SURFACES
FIGURE 1003.3.1(2) REDUCED VERTICAL CLEARANCE
741 FIGURE 1003.3.2(1) POST-MOUNTED OBJECTS
FIGURE 1003.3.2(2) POST-MOUNTED PROTRUDING OBJECTS
742 FIGURE 1003.3.3 EXAMPLES OF HORIZONTAL PROJECTIONS
743 FIGURE 1003.5 ELEVATION CHANGE
744 SECTION 1004 OCCUPANT LOAD
745 FIGURE 1004.1.1 COMBINED OCCUPANT LOAD FOR EGRESS DESIGN
746 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
747 FIGURE 1004.1.2 TYPICAL NET FLOOR AREA OCCUPANT LOAD CALCULATION
748 FIGURE 1004.3 EXAMPLE OF OCCUPANT LOAD LIMIT SIGN
749 FIGURE 1004.4 TYPICAL FIXED SEATING
750 SECTION 1005 MEANS OF EGRESS SIZING
753 FIGURE 1005.6(1) EGRESS CONVERGENCE AT FIRST STORY
FIGURE 1005.6(2) EGRESS CONVERGENCE AT INTERMEDIATE LEVEL
754 FIGURE 1005.6(3) NO EGRESS CONVERGENCE
755 FIGURE 1005.7.1 TYPICAL DOOR RESTRICTIONS INTO PASSAGEWAY, AISLE AND CORRIDOR WIDTH
SECTION 1006 MEANS OF EGRESS ILLUMINATION
757 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
760 FIGURE 1007.2.1 ELEVATOR REQUIRED FOR ACCESSIBLE MEANS OF EGRESS
762 FIGURE 1007.3(1) ACCESSIBLE MEANS OF EGRESS STAIRWAY WITH ENLARGED STORY-LEVEL LANDING
763 FIGURE 1007.3(2) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM AN AREA OF REFUGE
764 FIGURE 1007.3(3) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM A HORIZONTAL EXIT
766 FIGURE 1007.6 SEPARATE TRAVEL DISTANCES TO AN AREA OF REFUGE
770 FIGURE 1007.7.3 EXTERIOR AREA OF RESCUE ASSISTANCE—PLAN VIEW
771 FIGURE 1007.7.4 EXTERIOR AREA OF RESCUE ASSISTANCE—ELEVATION
773 SECTION 1008 DOORS, GATES AND TURNSTILES
775 FIGURE 1008.1.1(1) TYPICAL DOOR OPENING CLEARANCE
FIGURE 1008.1.1(2) TYPICAL DOOR OPENING CLEARANCE WITH PANIC HARDWARE
778 FIGURE 1008.1.4.1(1) REVOLVING DOORS IN BOOKFOLD POSITION
FIGURE 1008.1.4.1(2) TYPICAL REVOLVING DOOR/SIDE SWINGING DOOR ARRANGEMENT
779 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
782 FIGURE 1008.1.5 DOOR LANDINGS
783 FIGURE 1008.1.7(1) VERTICAL CHANGES IN LEVEL
FIGURE 1008.1.7(2) BEVELED CHANGES IN LEVEL
FIGURE 1008.1.7(3) BEVELED CHANGES IN LEVEL
FIGURE 1008.1.7(4) DOOR THRESHOLD HEIGHT LIMITATIONS
784 FIGURE 1008.1.8(1) SPACING OF DOORS IN SERIES
FIGURE 1008.1.8(2) SPACING OF DOORS IN SERIES
785 FIGURE 1008.1.9.1 DOOR HARDWARE
786 FIGURE 1008.1.9.3 SURFACE AND FLUSH BOLT LOCATIONS
787 FIGURE 1008.1.9.4 TYPICAL MANUAL BOLT HARDWARE
793 FIGURE 1008.1.10.1 EXAMPLES OF TYPICAL PANIC HARDWARE
794 FIGURE 1008.1.10.1—continued EXAMPLES OF TYPICAL PANIC HARDWARE
795 SECTION 1009 STAIRWAYS
798 FIGURE 1009.3 DRAFT CURTAIN, EXCEPTIONS 3 AND 4
802 FIGURE 1009.5(1) STAIRWAY HEADROOM REQUIREMENTS
FIGURE 1009.5(2) EXAMPLE OF SECTION 1009.2, EXCEPTION 2
804 FIGURE 1009.7.1 TREAD DEPTH MEASUREMENT
FIGURE 1009.7.2 TREAD/RISER DIMENSIONS
806 FIGURE 1009.7.3 STAIR WINDERS WITHIN A DWELLING
807 FIGURE 1009.7.4(1) CONSISTENTLY SHAPED WINDERS
FIGURE 1009.7.4(2) SLOPED LANDING
808 FIGURE 1009.7.5.1 TREAD/RISER PROFILE (SOLID RISER)
809 FIGURE 1009.7.5.3 TREAD/RISER PROFILE (OPEN RISER)
FIGURE 1009.8(1) TYPICAL LANDING DIMENSIONS STRAIGHT-RUN STAIRWAY
810 FIGURE 1009.8(2) TYPICAL LANDING DIMENSIONS STRAIGHT-RUN STAIRWAY
FIGURE 1009.8(3) REVERSING RUN STAIRWAY
811 FIGURE 1009.9.1 OPEN TREAD IN ACCORDANCE WITH EXCEPTION 1
FIGURE 1009.8(4) DOOR CLEARANCE REQUIREMENTS IN STAIRWAY
812 FIGURE 1009.10 STAIRWAY RISE LIMITATION
813 FIGURE 1009.11 CURVED STAIRWAYS—MINIMUM DIMENSIONAL REQUIREMENTS
814 FIGURE 1009.12 SPIRAL STAIRWAYS
FIGURE 1009.13 TYPICAL ALTERNATING TREAD DEVICE
816 FIGURE 1009.14 TYPICAL SHIP LADDER
817 FIGURE 1009.15 EXAMPLE OF SECTION 1009.15, EXCEPTION 3
818 SECTION 1010 RAMPS
819 FIGURE 1010.3 TYPICAL MEANS OF EGRESS RAMP
820 FIGURE 1010.6.3 DOORWAY OPENING ONTO LANDING
821 FIGURE 1010.7 RAMP LANDINGS
822 FIGURE 1010.9(1) RAMP WITH HANDRAIL AT WALL
823 FIGURE 1010.9(2) RAMP WITH HANDRAIL AND BARRIER
FIGURE 1010.9(3) RAMP WITH HANDRAIL AND CURB
FIGURE 1010.9(4) RAMP WITH HANDRAIL AND GUARD
825 FIGURE 1010.10.1 EDGE PROTECTION
SECTION 1011 EXIT SIGNS
826 FIGURE 1011.1 EXIT SIGNS WITHIN AN EXIT ENCLOSURE
828 FIGURE 1011.6.1 MINIMUM SIZES OF EXIT SIGNS
SECTION 1012 HANDRAILS
829 FIGURE 1012.2 HANDRAIL REQUIREMENTS
830 FIGURE 1012.3.1 EXAMPLE OF TYPE I ALTERNATIVE HANDRAIL CONFIGURATION
831 FIGURE 1012.3.2 EXAMPLES OF TYPE II HANDRAIL CONFIGURATIONS
832 FIGURE 1012.4(1) EXAMPLES OF PROHIBITED HANDRAIL DESIGNS
FIGURE 1012.4(2) REDUCED BRACKET EXTENSIONS EXAMPLE PER SECTION 1012.4, EXCEPTION 3
834 FIGURE 1012.8(1) TYPICAL HANDRAIL ARRANGEMENT
FIGURE 1012.8(2) PROJECTION OF HANDRAIL
835 FIGURE 1012.9 HANDRAILS FOR MONUMENTAL STAIRS
SECTION 1013 GUARDS
836 FIGURE 1013.2(1) OPEN-SIDED WALKING AREA
FIGURE 1013.2(2) DROP OFF MEASUREMENTS AND GUARD HEIGHTS
837 FIGURE 1013.2(3) DROP OFF MEASUREMENTS AND GUARD HEIGHTS FOR 2- AND 3-STORY GROUP R-3 AND R-2
FIGURE 1013.2.1 GUARD SYSTEM WITH GLAZING
838 FIGURE 1013.3 GUARD HEIGHT
839 FIGURE 1013.4(1) GUARD OPENING LIMITATIONS
840 FIGURE 1013.4(2) EXAMPLE OF GUARD WITH HORIZONTAL MEMBERS
841 FIGURE 1013.7 PROTECTION AT ROOF-HATCH OPENING
842 SECTION 1014 EXIT ACCESS
843 FIGURE 1014.2(1) EGRESS PROHIBITED THROUGH GROUP H AREAS
FIGURE 1014.2(2) EGRESS THROUGH ADJOINING ROOMS AND SPACES
844 FIGURE 1014.3 COMMON PATH OF EGRESS TRAVEL
845 TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
846 TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
848 FIGURE 1015.2.1(1) EXAMPLES OF REMOTENESS BETWEEN EXITS OR EXIT ACCESS DOORS FROM A ROOM OR BUILDING
849 FIGURE 1015.2.1(2) REMOTENESS OF EXITS INTERCONNECTING BY A 1-HOUR FIRE-RESISTANCE-RATED CORRIDOR
FIGURE 1015.2.1(3) REMOTENESS OF EXITS IN A BUILDING WITH AN AUTOMATIC SPRINKLER SYSTEM
850 FIGURE 1015.2.1(4) REMOTE LOCATION OF EXIT ACCESS DOORS (ADJOINING ROOMS)
851 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
852 TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCE
853 FIGURE 1016.3(1) LENGTH OF EXIT ACCESS TRAVEL
FIGURE 1016.3(2) MEASURING TRAVEL DISTANCE USING RECTILINEAR APPROACH
854 SECTION 1017 AISLES
FIGURE 1017.3 AISLES AND AISLE ACCESSWAYS IN MERCANTILE
855 SECTION 1018 CORRIDORS
856 TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
FIGURE 1018.1 APPLICATION OF TABLE 1018.1
857 TABLE 1018.2 MINIMUM CORRIDOR WIDTH
859 FIGURE 1018.4(1) ALLOWABLE DEAD-END CONDITIONS
FIGURE 1018.4(2) CORRIDOR LENGTH/WIDTH RATIO FOR DEAD-END CONSIDERATIONS
861 FIGURE 1018.6(1) CORRIDOR CONTINUITY—EXAMPLE 1
862 FIGURE 1018.6(2) CORRIDOR CONTINUITY—EXAMPLE 2
FIGURE 1018.6(3) CORRIDOR CONTINUITY—EXAMPLE 3
863 FIGURE 1018.6(4) ELEVATOR LOBBY/CORRIDOR OPTION 1
FIGURE 1018.6(5) ELEVATOR LOBBY/CORRIDOR OPTION 2
864 FIGURE 1018.6(6) ELEVATOR LOBBY/CORRIDOR OPTION 3
SECTION 1019 EGRESS BALCONIES
865 FIGURE 1019.2 EGRESS BALCONIES
SECTION 1020 EXITS
866 SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION
867 FIGURE 1021.1 NUMBER OF EXITS
870 FIGURE 1021.2(1) EXAMPLE 1 OF EXCEPTION 7—NOT PERMITTED
FIGURE 1021.2(2) EXAMPLE 2 OF EXCEPTION 7—PERMITTED
871 TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
872 FIGURE 1021.2(3) EXAMPLE OF SINGLE-EXIT APARTMENT BUILDING
FIGURE 1021.2(4) EXAMPLE OF SINGLE-EXIT APARTMENT WITHIN A TWO-EXIT BUILDING
873 FIGURE 1021.2.1 STORIES WITH ONE EXIT
874 FIGURE 1021.2.3 MULTISTORY DWELLING UNITS
876 SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
880 FIGURE 1022.7(1) EXAMPLES OF EXTERIOR WALL PROTECTIVES
881 FIGURE 1022.7(2) EXTERIOR WALL PROTECTION
882 FIGURE 1022.8 EXAMPLE OF DISCHARGE IDENTIFICATION
884 FIGURE 1022.10.2(1) TYPICAL SMOKEPROOF ENCLOSURE ENTRY
FIGURE 1022.10.2(2) TYPICAL SMOKEPROOF ENCLOSURE WITH OPEN BALCONY ARRANGEMENT
SECTION 1023 EXIT PASSAGEWAYS
885 FIGURE 1023.1 ARRANGEMENT FOR LOBBY AND PASSAGEWAY
887 SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
888 FIGURE 1024.2.1 LEADING EDGE OF STEP AND LANDING
FIGURE 1024.2.3 HANDRAIL MARKINGS
889 FIGURE 1024.2.4.1 PERIMETER DEMARCATION LINES—FLOOR-MOUNTED OPTION
890 FIGURE 1024.2.4.2 PERIMETER DEMARCATION LINES—WALL-MOUNTED OPTION
FIGURE 1024.2.4.3 PERIMETER DEMARCATION LINES—OPTIONS AT DOORS INTO EXIT ENCLOSURES
891 FIGURE 1024.2.5 OBSTACLE MARKINGS
FIGURE 1024.2.6.1 EMERGENCY EXIT SYMBOL
892 FIGURE 1024.2.6 EXAMPLES OF EXIT DOOR TO EXTERIOR OPTIONS
893 SECTION 1025 HORIZONTAL EXITS
894 FIGURE 1025.1 TYPICAL HORIZONTAL EXITS
896 FIGURE 1025.4 REFUGE AREA EXCEPTION
SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
897 FIGURE 1026.3 EXTERIOR STAIRWAY
898 FIGURE 1026.5 EXTERIOR BALCONY AND STAIRWAY ADJACENT TO LOT LINE
900 FIGURE 1026.6(1) PROTECTION OF EXTERIOR STAIRWAYS
901 FIGURE 1026.6(2) EXTERIOR BALCONY WITH REMOTE STAIRWAYS
FIGURE 1026.6(3) EXAMPLE OF EXCEPTION 4
902 SECTION 1027 EXIT DISCHARGE
903 FIGURE 1027.1(1) PROTECTION OF LOBBY WITH AN EXIT DISCHARGE
904 FIGURE 1027.1(2) VESTIBULE WITH EXIT DISCHARGE
FIGURE 1027.1(3) SEPARATION DETAILS FOR VESTIBULE WITH EXIT DISCHARGE
906 SECTION 1028 ASSEMBLY
907 FIGURE 1028.2 GROUP A-1 WITH WAITING SPACE
909 FIGURE 1028.6.1(1) COMPUTATION OF WIDTH FOR STEPPED AISLES
910 FIGURE 1028.6.1(2) COMPUTATION OF WIDTH FOR LEVEL, SLOPED OR RAMPED AISLES
911 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
FIGURE 1028.6.2.2(1) ROOF HEIGHT (CONVEX DOME ROOF)
912 FIGURE 1028.6.2.2(2) ROOF HEIGHT (CONCAVE SUSPENDED ROOF)
913 FIGURE 1028.6.2.3(1) INDOOR SEATING SPRINKLERED AREAS (CONVEX DOME ROOF)
FIGURE 1028.6.2.3(2) INDOOR SEATING SPRINKLERED AREAS (CONCAVE SUSPENDED ROOF)
915 FIGURE 1028.8.1 PATH THROUGH ADJACENT ROWS
916 FIGURE 1028.9.2 TYPICAL AISLE CATCHMENTS
917 FIGURE 1028.9.3 COMPUTATION OF EXIT PASSAGE FOR CONVERGING AISLES
918 FIGURE 1028.9.4 AISLE WITH OPPOSITE EXITS
919 FIGURE 1028.9.5 TYPICAL BALCONY ARRANGEMENT
920 FIGURE 1028.10.1 AISLE AND AISLE ACCESSWAY MEASUREMENT WITH SEATING AND TABLES
FIGURE 1028.10.1.1 ACCESS FOR TABLES AND SEATING
921 FIGURE 1028.10.2 MINIMUM REQUIRED ROW WIDTH CLEARANCE FOR AISLE ACCESSWAYS
922 TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
FIGURE 1028.10.2.1 TYPICAL DUAL ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH
923 FIGURE 1028.10.2.2 TYPICAL SINGLE ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH
924 FIGURE 1028.11.1 TYPICAL SEATING PLATFORMS ALSO USED AS STEPPING AISLES
925 FIGURE 1028.11.2 TYPICAL RISER CONSTRUCTION IN STEPPED AISLES
926 FIGURE 1028.13 TYPICAL RAILING FOR RAMPED AISLES WITH RAILING IN THE AISLE
927 FIGURE 1028.13.1 DISCONTINUOUS AISLE HANDRAILS
928 FIGURE 1028.14.2 TYPICAL BALCONY GUARDS AT FASCIA
SECTION 1029 EMERGENCY ESCAPE AND RESCUE
929 FIGURE 1029.2 EMERGENCY ESCAPE WINDOW
930 BIBLIOGRAPHY
931 FIGURE 1029.5 WINDOW WELLS AT EMERGENCY ESCAPE WINDOWS
934 CHAPTER 11: ACCESSIBILITY
937 SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
938 SECTION 1103 SCOPING REQUIREMENTS
940 FIGURE 1103.2.7 EXAMPLE OF RAISED AREA EXCEPTION
941 SECTION 1104 ACCESSIBLE ROUTE
943 FIGURE 1104.3.2 EXAMPLE OF PRESS BOX ACCESSED FROM BLEACHER SEATING
945 SECTION 1105 ACCESSIBLE ENTRANCES
946 FIGURE 1105.1.2 EXAMPLE OF ELEVATED WALKWAY ENTRANCE
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
947 TABLE 1106.1 ACCESSIBLE PARKING SPACES
949 FIGURE 1106.6 EXAMPLE OF ACCESSIBLE PARKING SPACES
950 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
958 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
960 FIGURE 1107.6.2.1.2(1) BUILDING WITH FIRE WALLS IS TREATED AS A SINGLE STRUCTURE
961 FIGURE 1107.6.2.1.2(2) TWO STRUCTURALLY JOINED BUILDINGS ARE TREATED AS A SINGLE STRUCTURE
963 FIGURE 1107.7.1.1 DWELLING UNITS ON ONE STORY
964 FIGURE 1107.7.1.2(1) BUILDING HAS TWO ACCESSIBLE LEVELS, EACH WITH AN ACCESSIBLE ENTRANCE ON AN ACCESSIBLE ROUTE
FIGURE 1107.7.1.2(2) SINGLE BUILDING WITH MULTIPLE COMMON ENTRANCES—LOWER GROUND FLOOR UNITS MAY BE COVERED
965 FIGURE 1107.7.1.2(3) EXAMPLE FOR GRADE CALCULATIONS
966 FIGURE 1107.7.2(1) BUILDINGS WITH ELEVATOR(S): ALL SINGLE-STORY UNITS AND THE PRIMARY ENTRY LEVEL OF MULTISTORY UNITS
FIGURE 1107.7.2(2) GROUND FLOOR UNITS IN BUILDINGS OF FOUR OR MORE UNITS
967 FIGURE 1107.7.3(1) DWELLING UNITS OVER SHOPS AND GARAGES
FIGURE 1107.7.3(2) ELEVATOR TO FIRST FLOOR OF DWELLING UNITS ABOVE GRADE OR ENTRANCE LEVEL DOES NOT MAKE AN ELEVATOR BUILDING
968 FIGURE 1107.7.4 SITE ANALYSIS TEST: THE NUMBER OF COVERED UNITS
969 FIGURE 1107.7.5(1) BUILDING MEETS BOTH ACCESSIBILITY CRITERIA FOR EXEMPTION
FIGURE 1107.7.5(2) BUILDING MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS
970 SECTION 1108 SPECIAL OCCUPANCIES
971 TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
FIGURE 1108.2.2.3(1) EXAMPLE OF BOX SEATING IN A SPORTS VENUE
FIGURE 1108.2.2.3(2) EXAMPLE OF BOX SEATING IN A THEATER
973 FIGURE 1108.2.6 EXAMPLE OF LAWN SEATING
974 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
976 FIGURE 1108.2.9.1 EXAMPLE OF DINING SEATING
TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
977 FIGURE 1108.4.1.2 GALLERY SEATING
978 FIGURE 1108.4.1.5 COURTROOM WELL WORK STATIONS
FIGURE 1108.4.3.1 EXAMPLE OF ACCESSIBLE VISITOR CUBICLE IN A COURTHOUSE
979 SECTION 1109 OTHER FEATURES AND FACILITIES
980 FIGURE 1109.2(1 ) SIDE APPROACH WHEELCHAIR TRANSFER
981 FIGURE 1109.2(2) EXAMPLES OF TOILET ROOM PLANS WITH OVERLAP
983 FIGURE 1109.2.2(1) AMBULATORY-ACCESSIBLE COMPARTMENT
984 FIGURE 1109.2.2(2) WHEELCHAIR-ACCESSIBLE COMPARTMENT; OUT-SWINGING DOOR
FIGURE 1109.2.2(3) WHEELCHAIR-ACCESSIBLE COMPARTMENT; IN-SWINGING DOOR
985 FIGURE 1109.4 EXAMPLE OF KITCHENETTE
986 FIGURE 1109.5.1 EXAMPLE OF DRINKING FOUNTAINS FOR PERSONS USING WHEELCHAIR AND STANDING PERSONS
989 FIGURE 1109.7(1) PLATFORM (WHEELCHAIR) LIFT
FIGURE 1109.7(2) STAIRWAY CHAIRLIFT
FIGURE 1109.8.1(1) EXAMPLE OF LOCKER AREA
990 FIGURE 1109.8.1(2) EXAMPLE OF LOCKER ROOM
991 FIGURE 1109.11 EXAMPLE OF ACCESSIBLE WORK STATION
992 FIGURE 1109.12.1 EXAMPLE OF ACCESSIBLE DRESSING ROOM
993 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
FIGURE 1109.12.3 SERVICE COUNTERS
996 SECTION 1110 SIGNAGE
FIGURE 1110.1 INTERNATIONAL SYMBOLS OF ACCESSIBILITY
997 FIGURE 1110.4 VARIABLE MESSAGE SIGNAGE
998 BIBLIOGRAPHY
1000 CHAPTER 12: INTERIOR ENVIRONMENT
1001 SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
1003 FIGURE 1203.2(1) COMBINATION OF SOFFIT AND RIDGE VENTS
1004 FIGURE 1203.2(2) VENTILATION OF RAFTER SPACE
1006 FIGURE 1203.4.1 NATURAL LIGHT AND VENTILATION WINDOWS
FIGURE 1203.4.1.1 NATURAL VENTILATION FROM ADJOINING SPACE
1007 FIGURE 1203.4.1.2 VENTILATION OPENINGS BELOW GRADE
1008 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
1009 FIGURE 1205.2.1 NATURAL LIGHT FROM ADJACENT SPACE
1010 FIGURE 1205.3 ARTIFICIAL LIGHTING IN A ROOM
SECTION 1206 YARDS OR COURTS
1011 FIGURE 1206.1 YARDS AND COURTS
1012 FIGURE 1206.3 DIMENSIONS OF COURTS
1013 SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
1014 FIGURE 1208.2(1) MINIMUM CEILING HEIGHT—ALLOWABLE PROJECTIONS IN ONE- AND TWO-FAMILY DWELLINGS
FIGURE 1208.2(2) SLOPED CEILING HEIGHTS
1015 FIGURE 1208.2.1 FURRED CEILING HEIGHTS
SECTION 1209 ACCESS TO UNOCCUPIED SPACES
1016 SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
1017 BIBLIOGRAPHY
1018 CHAPTER 13: ENERGY EFFICIENCY
SECTION 1301 GENERAL
BIBLIOGRAPHY
1020 CHAPTER 14: EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
1023 SECTION 1404 MATERIALS
1025 SECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
1026 TABLE 1405.3.1 CLASS III VAPOR RETARDERS
1027 FIGURE 1405.3 CLIMATE ZONES FIGURE 1405.3 FROM FIGURE C301.1 OF THE IECC
1028 TABLE 1450.3 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1029 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1030 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1031 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1032 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1033 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1034 TABLE 1405.3—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1035 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1036 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1037 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1038 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1039 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1040 TABLE 1405.3—continuedCLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
1041 TABLE C301(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE 1405.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
1042 FIGURE 1405.4(1) FLASHING AT SIDING ROOF INTERFACE
FIGURE 1405.4(2) FLASHING AT SIDING/WINDOW INTERFACE
FIGURE 1405.4(3) FLASHING UNDER WINDOW IN EXTERIOR WALL
FIGURE 1405.4(4) FLASHING AT VARIOUS POINTS
1043 FIGURE 1405.4(5) FLASHING EXTENSION
1045 FIGURE 1405.7 STONE VENEER WITH CONCRETE BACKING
1047 FIGURE 1405.9 TERRA COTTA VENEER
FIGURE 1405.10(1) MASONRY VENEER ADHERED TO MASONRY BACKING
1048 FIGURE 1405.10(2) MASONRY VENEER ADHERED TO STEEL-FRAME BACKING
1052 FIGURE 1405.17 WOOD WEATHERBOARD ATTACHMENT
SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
1054 TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
1055 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
1056 FIGURE 1406.4 ORIEL WINDOW
FIGURE 1407.1(1) CONTINUOUS EDGE GRIP SYSTEM
1057 FIGURE 1407.1(2) SECTION THROUGH VERTICAL JOINT (HORIZONTAL JOINT SIMILAR)
FIGURE1407.1(3) TYPICAL RUT AND RETURN SYSTEM SECTION THROUGH VERTICAL JOINT (HORIZONTAL JOINT SIMILAR)
1061 FIGURE 1407.11.3.4 FLAME BARRIER
TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
1063 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
1064 SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
1066 BIBLIOGRAPHY
1068 CHAPTER 15: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
1069 SECTION 1503 WEATHER PROTECTION
1070 SECTION 1504 PERFORMANCE REQUIREMENTS
1072 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
1073 TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
1074 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
1076 TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a
TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
1078 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
1081 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa, b, c
1083 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
1087 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
1088 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
1089 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
1090 FIGURE 1507.8.4(1) POSSIBLE WATER DAMAGE AT ICE DAMS
FIGURE 1507.8.4(2) PROTECTIVE ICE SHEILD
1091 TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
1092 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
1093 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
1094 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
1096 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
1097 SECTION 1508 ROOF INSULATION
1098 TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOFTOP STRUCTURES
1103 SECTION 1510 REROOFING
1104 SECTION 1511 SOLAR PHOTOVOLTAIC PANELS/MODULES
BIBLIOGRAPHY
1108 INDEX
1146 TRAINING RESOURCES
1147 ICC PLAN REVIEW SERVICES
1148 VALUABLE GUIDES TO CHANGES IN THE 2012 I-CODES®
1149 A117.1 IMPROVING ACCESSIBILITY FOR 50 YEARS
1150 2012 IBC CODE AND COMMENTARY VOLUME 2
1151 2012 IBC CODE AND COMMENTARY VOLUME 2 TITLE PAGE
1152 COPYRIGHT
1153 PREFACE
1155 TABLE OF CONTENTS
1157 CHAPTER 16: STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
1159 SECTION 1603 CONSTRUCTION DOCUMENTS
1161 SECTION 1604 GENERAL DESIGN REQUIREMENTS
1162 TABLE 1604.3 DEFLECTION LIMITS
1163 TABLE 1604.3.6 CONCRETE ROOF MEMBER DEFLECTION CRITERIA
1165 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
1168 EQUATION 16-6
EQUATION 16-7
EQUATION 16-15
EQUATION 16-16
EQUATION 16-22
EQUATION 16-18
1169 SECTION 1605 LOAD COMBINATIONS
1170 FIGURE 1605.1(1) EXAMPLES OF DISCONTINUOUS SHEAR WALLS
FIGURE 1605.1(2) COLLECTORS
1171 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
1172 EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
1173 EQUATION 16-17
EQUATION 16-18
EQUATOIN 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
1174 SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
1175 TABLE 1607.1(1) SUMMARY OF MINIMUM LIVE LOAD REQUIRED IN UNINHABITABLE ATTICS
FIGURE 1607.1 DETERMINATION OF ATTIC LIVE LOAD IN ACCORDANCE WITH TABLE 1607.1 FOOTNOTES I, J AND K
1176 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADS
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADS
1177 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADS
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADS
1180 FIGURE 1607.8.1 HANDRAIL DESIGN LOAD
FIGURE 1607.8.1.2 COMPONENT DESIGN LOAD
1181 FIGURE 1607.8.3 VEHICLE BARRIER REQUIREMENTS
1182 EQUATION 16-23
TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR
1183 FIGURE 1607.10.1 LIVE LOAD REDUCTION EXAMPLE
1184 EQUATION 16-24
EQUATION 16-25
1185 FIGURE 1607.11 PARTIAL LOADING
1186 EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
FIGURE 1607.12.2.1 MINIMUM ROOF LIVE LOAD IN ACCORDANCE WITH EQUATION 16-26
1188 FIGURE 1607.13 TOP-RUNNING BRIDGE CRANE
SECTION 1608 SNOW LOADS
1189 FIGURE 1608.1(1) BALANCED AND UNBALANCED LOADS FOR A SAWTOOTH ROOF
1190 FIGURE 1608.1(2) DRIFTING SNOW ON LOW ROOFS AND DECKS
FIGURE 1608.1(3) DRIFTING SNOW ONTO ADJACENT LOW STRUCTURE
1191 FIGURE 1608.1(4) SNOW DRIFTING AT ROOF PROJECTIONS
TABLE 1608.2 GROUND SNOW LOADS, pg , FOR ALASKAN LOCATIONS
1192 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES
1193 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES
1194 SECTION 1609 WIND LOADS
1195 FIGURE 1609.1(1) WIND PRESSURES CAUSED BY EXTERNAL WIND FLOW
FIGURE 1609.1(2) OPENING IN EXTERIOR WALL OF BUILDING
1197 FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
1198 FIGURE 1609B ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY III AND IV BUILDINGS AND OTHER STRUCTURES
1199 FIGURE 1609C ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
1200 FIGURE 1609.1.1.1 WIND SPEED-UP EFFECT
1201 FIGURE 1609.1.2 EFFECTS OF OPENINGS IN THE BUILDING ENVELOPE
1202 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
1203 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONS
1205 EQUATION 16-34
1207 EQUATION 16-35
1208 TABLE 1609.6.2 NET PRESSURE COEFFICIENTS
1209 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
1210 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
1211 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
1212 TABLE 1610.1 LATERAL SOIL LOAD
EQUATION 16-36
1213 FIGURE 1611.1(1) SECONDARY ROOF DRAINAGE NOT REQUIRED
TABLE 1611.1(2) FLOW RATE, IN GALLONS PER MINUTE, OF VARIOUS ROOF DRAINS AT VARIOUS WATER DEPTHS AT DRAIN INLETS (INCHES)
1214 FIGURE 1611.1(3) SEPARATE PRIMARY AND SECONDARY ROOF DRAINS
1215 FIGURE 1611.1(4) EQUATION 16-35 COEFFICIENT
FIGURE 1611.1(5) RAIN LOAD EXAMPLE
1216 FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
1217 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
1218 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
1219 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
1220 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
1221 SECTION 1612 FLOOD LOADS
1225 SECTION 1613 EARTHQUAKE LOADS
1227 EQUATION 16-37
EQUATION 16-38
1228 EQUATION 16-39
EQUATION 16-40
TABLE 1613.3.3 (1) VALUES OF SITE COEFFICIENT
TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT
1229 TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATIONS
TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
1230 FIGURE 1613.3.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1231 FIGURE 1613.3.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1232 FIGURE 1613.3.1(2)RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1233 FIGURE 1613.3.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1234 FIGURE 1613.3.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1235 FIGURE 1613.3.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1236 FIGURE 1613.3.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
1237 FIGURE 1613.3.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5%OF CRITICAL DAMPING), SITE CLASS B
1238 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 STRUCTURAL INTEGRITY
1240 EQUATION 16-41
FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
1241 EQUATION 16-42
BIBLIOGRAPHY
1247 CHAPTER 17: SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
1248 SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
1250 FIGURE 1703.5.3 TYPICAL LABEL INFORMATION
SECTION 1704 SPECIAL INSPECTIONS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATIONS
1254 SECTION 1705 REQUIRED VERIFICATION AND INSPECTION
1255 TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL
1256 TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
1258 TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS
1259 TABLE 1705.7 REQUIRED VERIFICATION AND INSPECTION OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
1269 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 TEST SAFE LOAD
1270 SECTION 1709 IN-SITU LOAD TESTS
SECTION 1710 PRECONSTRUCTION LOAD TESTS
1272 SECTION 1711 MATERIAL AND TEST STANDARDS
1274 BIBLIOGRAPHY
1277 CHAPTER 18: SOILS AND FOUNDATIONS
1278 SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
1279 FIGURE 1803.5.2 TYPICAL SETUP FOR CONDUCTING STATIC LOAD TESTS
1280 FIGURE 1803.5.3 SWELLING POTENTIAL OF SOILS AND PLASTICITY INDEX
1284 SECTION 1804 EXCAVATION, GRADING AND FILL
1286 SECTION 1805 DAMPPROOFING AND WATERPROOFING
1289 FIGURE 1805.2.2 MATERIALS FOR WATERPROOFING AND DAMPROOFING INSTALLATIONS
1291 FIGURE 1805.3.2 MATERIALS FOR WATERPROOFING INSTALLATIONS
1292 FIGURE 1805.3.3(1) DETAIL—MEMBRANE PLACEMENT THROUGH A KEY JOINT
1293 FIGURE 1805.3.3(2) PIPE DETAIL—PROPER PLACEMENT OF WATERPROOFING ELEMENTS
1294 FIGURE 1805.4.2 FOUNDATION DRAINAGE SYSTEM
1295 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
1296 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
1297 SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
FIGURE 1807.1.2 UNBALANCED BACKFILL HEIGHT
1298 FIGURE 1807.1.4 WOOD FOUNDATION
1300 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS
1302 FIGURE 1807.1.6.3 TIE AT TOP COURSE BED JOINT
TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
1303 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES
1304 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
1305 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
1306 EQUATION 18-1
EQUATION 18-2
1307 EQUATION 18-2
SECTION 1808 FOUNDATIONS
1311 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
FIGURE 1808.7.1(1) BUILDINGS ADJACENT TO ASCENDING SLOPE EXCEEDING 1 TO 1
1312 FIGURE 1808.7.2 BUILDINGS ADJACENT TO DESCENDING SLOPE EXCEEDING 1 TO 1
FIGURE 1808.7.4 FOOTING ELEVATION ON GRADED SITES
1313 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ”²C OF CONCRETE OR GROUT
1314 TABLE 1808.8.2 MINIMUM CONCRETE COVER
1315 SECTION 1809 SHALLOW FOUNDATIONS
1316 FIGURE 1809.6 ISOLATED FOOTINGS
1317 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
FIGURE 1809.8 PUNCHING SHEAR (EXAGGERATED ILLUSTRATION)
1318 FIGURE 1809.9.2 BRICK FOOTING OFFSET
1320 FIGURE 1809.10 FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
1321 SECTION 1810 DEEP FOUNDATIONS
1325 FIGURE 1810.3.1.2 COMPOSITE ELEMENTS
1326 FIGURE 1810.3.1.6 STEEL CASINGS
1327 FIGURE 1810.3.2.4 TIMBER PILES
1329 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
1333 EQUATION 18-4
1336 FIGURE 1810.3.5.3.1 STEEL H-PILE SECTIONS
1339 FIGURE 1810.3.8 PRECAST NONPRESTRESSED AND PRESTRESSED CONCRETE PILES
1340 EQUATION 18-5
1341 EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
1342 EQUATION 18-11
1345 FIGURE 1810.3.9.5 BELLED DRILLED SHAFT
FIGURE 1810.3.9.6 SOCKETED DRILLED SHAFTS
1349 FIGURE 1810.4.1.5 TYPICAL EFFECTS OF OVERDRIVING TIMBER PILES
1352 FIGURE 1810.4.7 ENLARGED BASE PILES—UNCASED OR CASED SHAFTS
1354 BIBLIOGRAPHY
1357 CHAPTER 19: CONCRETE
SECTION 1901 GENERAL
1358 SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
1364 SECTION 1904 DURABILITY REQUIREMENTS
1366 TABLE 1904.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH
SECTION 1905 MODIFICATIONS TO ACI 318
1367 FIGURE 1904.2 WEATHERING PROBABILITY MAP FOR CONCRETE
1368 FIGURE 1905.1.1 PLAN OF WALL WITH OPENINGS
1373 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
1374 SECTION 1908 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN
EQUATION 19-1
1375 TABLE 1908.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS (pounds)
1376 SECTION 1909 ANCHORAGE TO CONCRETE—STRENGTH DESIGN
SECTION 1910 SHOTCRETE
1380 SECTION 1911 REINFORCED GYPSUM CONCRETE
SECTION 1912 CONCRETE-FILLED PIPE COLUMNS
1381 BIBLIOGRAPHY
1387 CHAPTER 20: ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
BIBLIOGRAPHY
1389 CHAPTER 21: MASONRY
1390 SECTION 2101 GENERAL
1392 SECTION 2102 DEFINITIONS AND NOTATIONS
1393 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
1398 TABLE 2103.11 CERAMIC TILE MORTAR COMPOSITIONS
1400 SECTION 2104 CONSTRUCTION
1401 FIGURE 2104.2 CORBELED MASONRY
1402 FIGURE 2104.2.1 MOLDED CORNICE
SECTION 2105 QUALITY ASSURANCE
1403 TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY
1404 TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY
1405 SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
1406 EQUATION 21-1
SECTION 2108 STRENGTH DESIGN OF MASONRY
1407 SECTION 2109 EMPIRICAL DESIGN OF MASONRY
1408 TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
1409 EQUATION 21-2
1410 TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
1411 SECTION 2110 GLASS UNIT MASONRY
1412 SECTION 2111 MASONRY FIREPLACES
FIGURE 2111.1 SECTION THROUGH FIREPLACE
1414 FIGURE 2111.6 RUMFORD FIREPLACE
1416 FIGURE 2111.10 HEARTH EXTENSION
1417 FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
FIGURE 2111.11(1) COMBUSTIBLE MATERIALS PROJECTION ABOVE FIREPLACE OPENING
1418 FIGURE 2111.13.1 FACTORY-BUILT FIREPLACE EXTERIOR COMBUSTION AIR DUCT
SECTION 2112 MASONRY HEATERS
1419 SECTION 2113 MASONRY CHIMNEYS
1421 FIGURE 2113.5 CORBELING LIMITATIONS
1422 FIGURE 2113.6 MASONRY CHIMNEY CHANGE IN SHAPE (OFFSET)
1423 FIGURE 2113.9 MINIMUM TERMINATION OF CHIMNEYS
FIGURE 2113.9.1 MASONRY CHIMNEY CAP AND RAIN CAP
1426 FIGURE 2113.11.2.3 MASONRY CHIMNEY FOR MEDIUM-HEAT APPLIANCE
1428 FIGURE 2113.14 LOW-HEAT CHIMNEY WITH MORE THAN TWO FLUES
1429 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES
1430 TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
1431 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
BIBLIOGRAPHY
1432 FIGURE 2113.20(1) FIREBLOCKING
FIGURE 2113.20(2) FIREBLOCKING (SECTION)
1435 CHAPTER 22: STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
1436 SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
1437 SECTION 2205 STRUCTURAL STEEL
1438 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
1439 SECTION 2208 STEEL CABLE STRUCTURES
1440 SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
1441 SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
FIGURE 2211.2 HEADER TYPES
1442 BIBLIOGRAPHY
1445 CHAPTER 23: WOOD
1446 SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
1447 SECTION 2303 MINIMUM STANDARDS AND QUALITY
1448 FIGURE 2303.1.1 TYPICAL LABELS (Grade Marks) American Lumber Standards Committee, U.S.D.C.
1457 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
1460 TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING
1461 TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
1462 TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
1463 TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
1464 TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a, b (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)a, b
1465 FIGURE 2304.8.2.1 SIMPLE SPAN PATTERN
FIGURE 2304.8.2.2 TWO-SPAN CONTINUOUS PATTERN
1466 FIGURE 2304.8.2.3 COMBINATION SIMPLE AND TWO-SPAN CONTINUOUS PATTERN
FIGURE 2304.8.2.4 CANTILEVERED PIECES INTERMIXED PATTERN
1467 FIGURE 2304.8.4.1 TWO-INCH TONGUE-AND-GROOVE DECKING
1468 FIGURE 2304.8.4.3 CONTROLLED RANDOM PATTERN TWO-INCH TONGUE-AND-GROOVE DECKING
FIGURE 2304.8.5.1 THREE- AND FOUR-INCH TONGUE-AND-GROOVE DECKING
1469 FIGURE 2304.9.2 SHEATHING FASTENERS
1470 TABLE 2304.9.1 FASTENING SCHEDULE
1471 TABLE 2304.9.1—continued FASTENING SCHEDULE
1472 TABLE 2304.9.1—continued FASTENING SCHEDULE
1473 FIGURE 2304.9.1 STANDARD NAILS AND STAPLES
1477 FIGURE 2304.11.2.1 WOOD-FRAMING CLEARANCES
1478 FIGURE 2304.11.2.5 GIRDER END CLEARANCE
1479 FIGURE 2304.11.2.6(1) SIDING CLEARANCES
FIGURE 2304.11.2.6(2) SIDING CLEARANCE AT CONCRETE PATIO
1480 FIGURE 2304.11.2.7 POST AND COLUMN PROTECTION
1481 FIGURE 2304.11.6 TERMITE INFESTATION PROBABILITY MAP
1482 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
1483 EQUATION 23-1
1484 TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP
EQUATION 23-2
1485 SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
1488 FIGURE 2306.1 CERTIFICATE OF CONFORMANCE
1489 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
1491 FIGURE 2306.2(1) HOW WOOD SPLITS AND HOW STAGGERING MINIMIZES SPLITTING
FIGURE 2306.2(2) STAGGERED NAILING
1492 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
1493 TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
1494 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
1495 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
1496 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
1497 TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
1498 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
1505 FIGURE 2308.8.2 CUTTING, NOTCHING AND BORING JOISTS
1506 FIGURE 2308.8.3 FRAMING AROUND OPENING
FIGURE 2308.8.4 JOISTS SUPPORTING PARTITIONS AND HEAVY LOADS
1507 TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1508 TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1509 TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1510 TABLE 2308.8(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1511 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
1514 FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
1515 TABLE 2308.9.3(1) BRACED WALL PANELS
TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHING
1516 TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING
TABLE 2308.9.3(5) HARDBOARD SIDING
1517 FIGURE 2308.9.3.1 ALTERNATIVE BRACED WALL PANELS—ONE-STORY
1519 FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
1520 FIGURE 2308.9.5 HEADER SUPPORT CONDITIONS FOR EXTERIOR LOAD-BEARING WALLS
1521 TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
1522 TABLE 2308.9.5—continued HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS(Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
1523 FIGURE 2308.9.5.2(1) STUDS AND HEADERS AROUND WALL OPENINGS
FIGURE 2308.9.5.2(2) STUDS AND HEADERS AROUND WALL OPENINGS—BAY WINDOWS (Source: AF&PA Wood Frame Construction Manual for One- and Two-Family Dwellings, SBC High Wind Edition, 1995.
1524 TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS
FIGURE 2308.9.6 HEADER SUPPORT CONDITIONS FOR INTERIOR LOAD-BEARING WALLS
1525 FIGURE 2308.9.10 CUTTING, NOTCHING AND BORED HOLES IN STUDS
1527 TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
1528 FIGURE 2308.10.4 RAFTER END CUT AT RIDGE
FIGURE 2308.10.4.1 RAFTER TIES
1529 TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240)
1530 TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240)
1531 TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
1532 TABLE 2308.10.2(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
1533 TABLE 2308.10.3 (1)RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1534 TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1535 TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1536 TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1537 TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1538 TABLE 2308.10.3(3)— continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1539 TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1540 TABLE 2308.10.3(4)—continuedRAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
1541 TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1542 TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1543 TABLE 2308.10.3(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1544 TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
1545 FIGURE 2308.10.5 BRACED RAFTER CONSTRUCTION
1546 TABLE 2308.10.4.1 RAFTER TIE CONNECTIONS
1548 TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1549 TABLE 2308.10.9—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1551 FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS
FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS
1553 TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Percentage of Wall Bracing per each Braced Wall Linea)
1556 FIGURE 2308.12.6(1) BRACED WALL PANELS OUT OF PLANE
FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
1557 FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
1558 FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR
FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
BIBLIOGRAPHY
1563 CHAPTER 24: GLASS AND GLAZING
1564 SECTION 2401 GENERAL
1565 SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
FIGURE 2403.1 EXAMPLE IDENTIFYING MARK
1567 SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
1568 EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
1569 EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
1570 EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
1572 FIGURE 2405.3(1) FULLY TEMPERED GLAZING—30° MAXIMUM SLOPE
1573 FIGURE 2405.3(2) INACCESSIBLE AREA UNDER SLOPED GLAZING
1574 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
1576 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
1577 FIGURE 2406.4.1 EXAMPLES OF DOORS REQUIRING SAFETY GLAZING
1578 FIGURE 2406.4.2(1) SAFETY GLAZING IN CLOSE PROXIMITY TO DOORS
1579 FIGURE 2406.4.2(2) SAFETY GLAZING AT FULL-HEIGHT INTERVENING WALL
1580 FIGURE 2406.4.2(3) SAFETY GLAZING AT INTERMEDIATE-HEIGHT INTERVENING WALL
1581 FIGURE 2406.4.3(1) FIXED OR OPERABLE GLAZED OPENING
1582 FIGURE 2406.4.3(2) HORIZONTAL RAIL AT GLAZED OPENINGS
1583 FIGURE 2406.4.3(3) ELEVATED GLAZED OPENINGS
1584 FIGURE 2406.4.5(1) SAFETY GLAZING AT WET SURFACES
1585 FIGURE 2406.4.5(2) GLAZING IN POOL ENCLOSURE
SECTION 2407 GLASS IN HANDRAILS AND GUARDS
1586 FIGURE 2407.1 GLASS GUARDS
1587 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
1588 SECTION 2409 GLASS IN ELEVATOR HOISTWAYS AND ELEVATOR CARS
BIBLIOGRAPHY
1591 CHAPTER 25: GYPSUM BOARD AND PLASTER
SECTION 2501 GENERAL
1592 SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
1593 SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
FIGURE 2504.1.2(1) STUDLESS PLASTER PARTITION WITH GYPSUM BOARD LATH
1594 FIGURE 2504.1.2(2) STUDLESS PLASTER PARTITION WITH RIBBED METAL LATH
SECTION 2505 SHEAR WALL CONSTRUCTION
1595 SECTION 2506 GYPSUM BOARD MATERIALS
TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES
1596 SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
1597 SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
1599 TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
1600 FIGURE 2508.5(1) HORIZONTAL GYPSUM BOARD CEILING DIAPHRAGM CONSTRUCTION
FIGURE 2508.5(2) PARTITION SUPPORTED LATERALLY BY GYPSUM BOARD CEILING DIAPHRAGM
1601 FIGURE 2508.5.3 PERIMETER BLOCKING
SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
1602 SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
1603 FIGURE 2510.5 THREE-COAT PLASTER ON UNSHEATHED EXTERIOR STUD WALL
1605 SECTION 2511 INTERIOR PLASTER
1606 TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
FIGURE 2511.1(1) THREE-COAT PLASTER ON INTERIOR STUD WALL
1607 FIGURE 2511.1(2) TWO-COAT PLASTER ON INTERIOR STUD WALL
1608 SECTION 2512 EXTERIOR PLASTER
1609 FIGURE 2512.1 THREE-COAT PLASTER ON EXTERIOR STUD WALL
FIGURE 2512.1.2 WEEP SCREED FOR EXTERIOR PLASTER ON STUD WALL AT SLAB ON GRADE
1611 TABLE 2512.6 CEMENT PLASTERS
1612 SECTION 2513 EXPOSED AGGREGATE PLASTER
1613 BIBLIOGRAPHY
1615 CHAPTER 26: PLASTIC
1616 SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
1617 FIGURE 2603.1 FOAM PLASTIC COMPLIANCE
1621 FIGURE 2603.4.1.6 FOAM PLASTIC, ATTIC AND CRAWL SPACES
1623 FIGURE 2603.4.1.13 FOAM PLASTIC SPRAY APPLIED TO SILL PLATE AND HEADER
1626 FIGURE 2603.9 TERMITE INFESTATION PROBABILITY MAP
1627 SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
1628 SECTION 2606 LIGHT-TRANSMITTING PLASTICS
1630 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
1631 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANEL
1632 FIGURE 2607.4 FLAME BARRIER
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
1633 SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
1634 FIGURE 2609.2 PLASTIC ROOF PANEL SEPARATION FROM OTHER PANELS
1635 FIGURE 2609.3 PLASTIC ROOF PANEL SEPARATION FROM EXTERIOR WALL
TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
1636 SECTION 2610 LIGHT-TRANSMITTINGPLASTIC SKYLIGHT GLAZING
1637 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
1638 FIGURE 2611.3(1) MAXIMUM AREA OF LIGHT-TRANSMITTING PLASTIC SIGNS—EXAMPLE 1
SECTION 2612 FIBER-REINFORCED POLYMER
1639 FIGURE 2611.3(2) MAXIMUM AREA OF LIGHT-TRANSMITTING PLASTIC SIGNS—EXAMPLE 2
1641 SECTION 2613 REFLECTIVE PLASTIC CORE INSULATION
BIBLIOGRAPHY
1643 CHAPTER 27: ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
1645 BIBLIOGRAPHY
1647 CHAPTER 28: MECHANICAL SYSTEMS
SECTION 2801 GENERAL
1648 FIGURE 2801.1 EXAMPLE LABELS
BIBLIOGRAPHY
1649 CHAPTER 29: PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
1651 TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
1652 TABLE 2902.1—(continued) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
1653 TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
1656 TABLE 2902.1.1(1) SOLUTION SUMMARY FOR SAMPLE PROBLEM 1
1657 TABLE 2902.1.1(2) SOLUTION SUMMARY FOR SAMPLE PROBLEM 2
1659 TABLE 2902.1.1(3) SOLUTION SUMMARY FOR SAMPLE PROBLEM 3
1661 TABLE 2902.1.1(4) SOLUTION SUMMARY FOR SAMPLE PROBLEM 4
1662 FIGURE 2902.3(1) RESTAURANT ENTRY SIGN
1663 FIGURE 2902.3(2) CUSTOMER TOILET ACCESS
1664 FIGURE 2902.3.1 WALK-UP ICE CREAM SHOP WITH OUTDOOR SEATING
1666 BIBLIOGRAPHY
CHAPTER 30: ELEVATORS AND CONVEYING SYSTEMS
1667 SECTION 3001 GENERAL
1668 SECTION 3002 HOISTWAY ENCLOSURES
1670 FIGURE 3002.3 ELEVATOR CORRIDOR CALL STATION PICTOGRAPH
1671 FIGURE 3002.4(a) EXAMPLES–ELEVATOR CAR SIZING—3,500 lb PASSENGER ELEVATOR
1672 FIGURE 3002.4(b) EXAMPLES–ELEVATOR CAR SIZING—4,000 lb PASSENGER ELEVATOR
FIGURE 3002.6 ADDITIONAL DOOR IN FRONT OF HOISTWAY
1673 SECTION 3003 EMERGENCY OPERATIONS
1674 SECTION 3004 HOISTWAY VENTING
1675 FIGURE 3004.1 STACK EFFECT
1676 FIGURE 3004.3 SIZING OF VENT AREA
SECTION 3005 CONVEYING SYSTEMS
1677 FIGURE 3005.2.1 DRAFT AND SPRINKLER WATER CURTAIN
1678 SECTION 3006 MACHINE ROOMS
1679 FIGURE 3006.4 EXCEPTIONS MACHINE ROOM FIRE RESISTANCE
1680 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
1681 TABLE 3007.4 LOBBY COMPARISON TABLE—FIRE SERVICES ACCESS ELEVATORS AND OCCUPANT EVACUATION ELEVATORS
1683 FIGURE 3007.7.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
1684 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
1690 BIBLIOGRAPHY
1691 CHAPTER 31: SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
1694 FIGURE 3102.6.1 NONCOMBUSTIBLE AND FLAME-RESISTANT MEMBRANE CONSTRUCTION
1696 SECTION 3103 TEMPORARY STRUCTURES
1697 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
FIGURE 3104 EXAMPLE—PEDESTRIAN WALKWAY
1698 FIGURE 3104.5 PEDESTRIAN WALKWAY—BUILDING INTERFACE
1700 FIGURE 3104.10 TUNNELED WALKWAY
SECTION 3105 AWNINGS AND CANOPIES
1701 FIGURE 3105(1) EXAMPLE—CANOPY
FIGURE 3105(2) EXAMPLE OF CANOPY STRUCTURE
FIGURE 3105(3) EXAMPLE—AWNING
1702 SECTION 3106 MARQUEES
FIGURE 3106(1) EXAMPLE—MARQUEE
FIGURE 3106(2) EXAMPLE—MARQUEE
1703 FIGURE 3106.2 PERMISSIBLE PROJECTION, HEIGHT AND CLEARANCES FOR MARQUEES
1704 SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
1705 SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
1706 FIGURE 3109.4.1 OPENING LIMITATIONS
FIGURE 3109.4.1.1 BARRIER OPENINGS
1707 FIGURE 3109.4.1.3 PRIVATE SWIMMING POOL BARRIER CONSTRUCTION
FIGURE 3109.4.1.5 CHAIN-LINK FENCE MESH FORPRIVATE SWIMMING POOLS
1709 SECTION 3110 AUTOMATIC VEHICULAR GATES
1710 SECTION 3111 SOLAR PHOTOVOLTAIC PANELS/MODULES
BIBLIOGRAPHY
1711 CHAPTER 32: ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
1712 SECTION 3202 ENCROACHMENTS
FIGURE 3202.1.1 ENCROACHMENT BELOW GRADE
FIGURE 3202.1.3 AREAWAYS
1713 FIGURE 3202.2.1 STEPS
1714 FIGURE 3202.2.3 AWNINGS
1715 FIGURE 3202.3.1 AWNINGS, CANOPIES, MARQUEES AND SIGNS 8 FEET OR MORE ABOVE GRADE
FIGURE 3202.3.2 WINDOWS, BALCONIES, ARCHITECTURAL FEATURES AND MECHANICAL EQUIPMENT
1717 CHAPTER 33: SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
1718 SECTION 3303 DEMOLITION
1719 SECTION 3304 SITE WORK
SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
1720 TABLE 3306.1 PROTECTION OF PEDESTRIANS
1722 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
1723 SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
1724 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
BIBLIOGRAPHY
1725 CHAPTER 34: EXISTING STRUCTURES
1726 SECTION 3401 GENERAL
1728 SECTION 3402 DEFINITIONS
SECTION 3403 ADDITIONS
1729 FIGURE 3403.1 EXISTING BUILDING WITH ADDITION
1730 SECTION 3404 ALTERATIONS
1732 SECTION 3405 REPAIRS
1735 SECTION 3406 FIRE ESCAPES
1737 SECTION 3407 GLASS REPLACEMENT
SECTION 3408 CHANGE OF OCCUPANCY
1738 SECTION 3409 HISTORIC BUILDINGS
SECTION 3410 MOVED STRUCTURES
SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS
1744 TABLE 3411.8.5 RAMPS
1747 SECTION 3412 COMPLIANCE ALTERNATIVES
1751 EQUATION 34-1
EQUATION 34-2
1752 EQUATION 34-3
1753 EQUATION 34-4
FIGURE 3412.6.2.2(1) ALLOWABLE AREA—SINGLE OCCUPANCY BUILDING
1754 FIGURE 3412.6.2.2(2) ALLOWABLE AREA—MIXED OCCUPANCY BUILDING
1756 TABLE 3412.6.3 COMPARTMENTATION VALUES
1757 TABLE 3412.6.4 SEPARATION VALUES
FIGURE 3412.6.4.1(1) DWELLING UNIT SEPARATION
1758 FIGURE 3412.6.4.1(2) TENANT SEPARATION
1759 TABLE 3412.6.5 CORRIDOR WALL VALUES
FIGURE 3412.6.5(1) CORRIDOR WALL VALUES—CATEGORY
1760 FIGURE 3412.6.5(2) CORRIDOR WALL VALUES—CATEGORY
TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALUE
1761 TABLE 3412.6.6(2) CONSTRUCTION-TYPE FACTOR
EQUATION 34-5
1762 TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES
1763 TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES
1764 TABLE 3412.6.10 SMOKE CONTROL VALUES
1766 FIGURE 3412.6.11(1) MEANS OF EGRESS VALUES—CATEGORY
1767 TABLE 3412.6.11 MEANS OF EGRESS VALUES
FIGURE 3412.6.11(2) MEANS OF EGRESS VALUES—CATEGORY
1768 TABLE 3412.6.12 DEAD-END VALUES
1769 FIGURE 3412.6.12.1(1) TYPICAL DEAD-END CORRIDOR
FIGURE 3412.6.12.1(2) DEAD-END VALUES—CATEGORY
FIGURE 3412.6.12.1(3) DEAD-END VALUES—CATEGORY
1770 EQUATION 34-6
FIGURE 3412.6.13(1) EXIT ACCESS TRAVEL DISTANCE VALUES—OCCUPANCY GROUP S-1
1771 FIGURE 3412.6.13(2) EXIT ACCESS TRAVEL DISTANCE VALUES—OCCUPANCY GROUP B
FIGURE 3412.6.13(3) EXIT ACCESS TRAVEL DISTANCE VALUES—OCCUPANCY GROUP R
TABLE 3412.6.14 ELEVATOR CONTROL VALUES
1772 TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
1773 TABLE 3412.6.16 MIXED OCCUPANCY VALUES
1775 TABLE 3412.6.17 SPRINKLER SYSTEM VALUES
1776 TABLE 3412.6.18 STANDPIPE SYSTEM VALUES
1778 TABLE 3412.6.19 INCIDENTAL USE AREA VALUES
1779 TABLE 3412.7 SUMMARY SHEET—BUILDING CODE
1780 TABLE 3412.8 MANDATORY SAFETY SCORES
TABLE 3412.9 EVALUATION FORMULAS
1781 TABLE 3412.9 EVALUATION FORMULAS
BIBLIOGRAPHY
1783 CHAPTER 35: REFERENCED STANDARDS
1784 FIGURE 35 REFERENCED STANDARDS
1785 AA
AAMA
ACI
1786 AF&PA
AISC
AISI
1787 AITC
ALI
AMCA
ANSI
1788 APA
APSP
1789 ASABE
ASCE/SEI
ASME
1790 ASTM
1796 AWCI
AWPA
AWS
BHMA
1797 CGSB
CPA
CPSC
CSA
1798 CSSB
DASMA
DOC
DOJ
1799 DOL
DOTn
EN
FEMA
FM
1800 GA
HPVA
HUD
ICC
1801 ISO
NAAMM
1802 NCMA
NFPA
1803 PCI
PTI
1804 RMI
SDI
SJI
SPRI
TIA
1805 TMS
TPI
UL
1806 ULC
1807 USC
WDMA
WRI
1809 APPENDIX EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
1810 SECTION A102 REFERENCED STANDARDS
1811 APPENDIX B: BOARD OF APPEALS
SECTION B101 GENERAL
1815 APPENDIX C: GROUP U-AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
1816 SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
1817 SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
1819 APPENDIX D: FIRE DISTRICTS
SECTION D101 GENERAL
1820 FIGURE D101.2.1 EXAMPLE OF FIRE DISTRICTS
1821 FIGURE D101.2.2 BUFFER ZONES
SECTION D102 BUILDING RESTRICTIONS
1822 FIGURE D101.2.3 ADDING ADJACENT BLOCKS
1824 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
1825 FIGURE D104 BUILDINGS PARTIALLY WITHIN FIRE DISTRICTS
SECTION D106 REFERENCED STANDARDS
BIBLIOGRAPHY
1827 APPENDIX E: SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
1828 SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
1829 TABLE E104.3.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
1830 SECTION E105 OTHER FEATURES AND FACILITIES
1831 SECTION E106 TELEPHONES
1832 TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
1833 SECTION E107 SIGNAGE
1834 SECTION E108 BUS STOPS
1835 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
1837 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
BIBLIOGRAPHY
1839 APPENDIX F: RODENTPROOFING
SECTION F101 GENERAL
1841 APPENDIX G: FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
1842 SECTION G102 APPLICABILITY
1843 SECTION G103 POWERS AND DUTIES
1845 SECTION G104 PERMITS
1846 SECTION G105 VARIANCES
1849 SECTION G201 DEFINITIONS
1850 SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
1851 SECTION G501 MANUFACTURED HOMES
1852 SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
1853 SECTION G801 OTHER BUILDING WORK
1854 SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
1855 SECTION G1101 REFERENCED STANDARDS
BIBLIOGRAPHY
1857 APPENDIX H: SIGNS
SECTION H101 GENERAL
1858 SECTION H102 DEFINITIONS
1859 SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
1860 SECTION H106 ELECTRICAL
1861 SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
1862 SECTION H110 ROOF SIGNS
1863 SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
1864 FIGURE H112.5 ADDITIONAL SIGN LOADS
1865 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
1866 TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
1867 APPENDIX I: PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITIONS
SECTION I103 EXTERIOR WALLS AND OPENINGS
1868 FIGURE I102.1 PATIO COVERS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
1869 APPENDIX J: GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
1870 SECTION J103 PERMITS REQUIRED
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
1871 SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
1872 SECTION J107 FILLS
FIGURE J107.3 BENCHING DETAILS
1873 SECTION J108 SETBACKS
FIGURE J108.1 DRAINAGE DIMENSIONS
1874 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
1875 SECTION J111 REFERENCED STANDARDS
BIBLIOGRAPHY
1877 APPENDIX K: ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
1878 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
1879 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
1881 APPENDIX L: EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
1883 APPENDIX M: TSUNAMI-GENERATED FLOOD HAZARD
1884 SECTION M101 TSUNAMI-GENERATED FLOOD HAZARD
1886 SECTION M102 REFERENCED STANDARDS
BIBLIOGRAPHY
1887 INDEX
1925 COMMITTED TO BUILDING A GREEN AND SUSTAINABLE WORLD
1926 ICC EVALUATION SERVICE
1927 MEMBERSHIP BENEFITS
1928 VALUABLE GUIDES TO CHANGES IN THE 2012 I-CODES®
ICC IBC Commentary BothVolumes 2012
$157.08