The 2021 IFC® contains regulations to safeguard life and property from fires and explosion hazards. Topics include general precautions, emergency planning and preparedness, fire department access and water supplies, automatic sprinkler systems, fire alarm systems, special hazards, and the storage and use of hazardous materials. Key changes to the IFC include: Requirements for Additive Manufacturing (3-D Printing) equipment and operations for both non-industrial and industrial applications are now provided. Flame propagation performance of permanently installed artificial combustible vegetation is required to be verified when exceeding certain heights located on roofs or in close proximity to buildings. Provisions for emergency responder communication were revised to reflect the expansion of such systems beyond radios and the need for increased performance of such systems. Sprinkler requirements for the storage, manufacture and sale of upholstered furniture and mattresses were updated and clarified. Part of this update is a new exception for single-story self-storage facilities accessed directly from the exterior. An automatic sprinkler system is now required for open parking garages exceeding a certain fire area threshold. The requirements for energy storage system (ESS) were further refined to reflect the variety of new technologies and applications (in building and standalone) and the need for proper commissioning and decommissioning of such systems. A new chapter was added that provides clarification and specific requirements for the storage of distilled spirits and wines in barrels and casks. The provisions for construction fire safety were reorganized and expanded with an emphasis on the owner’s responsibilities. The new language requires a site safety plan and designation of a site safety director.

PDF Catalog

PDF Pages PDF Title
1 2021 IFC® INTERNATIONAL FIRE CODE®
2 2021 IFC® INTERNATIONAL FIRE CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 ARRANGEMENT AND FORMAT OF THE 2021 IFC
24 TABLE OF CONTENTS
34 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—GENERAL PROVISIONS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
SECTION 102 APPLICABILITY
35 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
SECTION 104 DUTIES AND POWERS OF THE FIRE CODE OFFICIAL
37 SECTION 105 PERMITS
40 TABLE 105.5.9 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.5.11 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
42 TABLE 105.5.22 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
TABLE 105.5.22—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
45 SECTION 106 CONSTRUCTION DOCUMENTS
46 SECTION 107 FEES
SECTION 108 INSPECTIONS
SECTION 109 MAINTENANCE
47 SECTION 110 SERVICE UTILITI
SECTION 111 MEANS OF APPEALS
SECTION 112 VIOLATIONS
48 SECTION 113 STOP WORK ORDER
SECTION 114 UNSAFE STRUCTURES OR EQUIPMENT
50 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
88 PART II—GENERAL SAFETY PROVISIONS
CHAPTER 3 GENERAL REQUIREMENTS
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
89 SECTION 304 COMBUSTIBLE WASTE MATERIAL
SECTION 305 IGNITION SOURCES
90 SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
SECTION 308 OPEN FLAMES
92 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
93 SECTION 310 SMOKING
SECTION 311 VACANT PREMISES
94 SECTION 312 VEHICLE IMPACT PROTECTION
95 SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
SECTION 315 GENERAL STORAGE
96 TABLE 315.7.6(1) SEPARATION DISTANCE BETWEEN WOOD PALLET STACKS AND BUILDINGS
97 TABLE 315.7.6(2) SEPARATION DISTANCE BETWEEN PLASTIC PALLET STACKS AND BUILDINGS
TABLE 315.7.6(3) SEPARATION FROM OTHER PALLET PILES AND ON-SITE STORAGE (WOOD PALLETS)
TABLE 315.7.6(4) SEPARATION FROM OTHER PALLET PILES AND ON-SITE STORAGE (PLASTIC PALLETS)
SECTION 316 HAZARDS TO FIRE FIGHTERS
98 SECTION 317 LANDSCAPED ROOFS
SECTION 318 LAUNDRY CARTS
SECTION 319 MOBILE FOOD PREPARATION VEHICLES
100 SECTION 320 ADDITIVE MANUFACTURING (3D PRINTING)
101 SECTION 321 ARTIFICIAL COMBUSTIBLE VEGETATION
102 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS
108 SECTION 404 FIRE SAFETY, EVACUATION AND LOCKDOWN PLANS
109 SECTION 405 EMERGENCY EVACUATION DRILLS
110 TABLE 405.3 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
111 SECTION 407 HAZARD COMMUNICATION
112 PART III—BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
113 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
114 SECTION 505 PREMISES IDENTIFICATION
SECTION 506 KEY BOXESBOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES
115 SECTION 508 FIRE COMMAND CENTER
116 SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
117 SECTION 510 EMERGENCY RESPONDER COMMUNICATION COVERAGE
120 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
SECTION 603 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
122 SECTION 604 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
123 SECTION 605 FUEL-FIRED APPLIANCES
126 SECTION 606 COMMERCIAL COOKING EQUIPMENT AND SYSTEMS
127 TABLE 606.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
SECTION 607 COMMERCIAL COOKING OIL STORAGE
128 SECTION 608 MECHANICAL REFRIGERATION
130 [M] TABLE 608.18.2 MINIMUM EXHAUST RATE
131 SECTION 609 HYPERBARIC FACILITIES
SECTION 610 CLOTHES DRYER EXHAUST SYSTEMS
132 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 PENETRATIONS
133 SECTION 704 JOINTS AND VOIDS
SECTION 705 DOOR AND WINDOW OPENINGS
SECTION 706 DUCT AND AIR TRANSFER OPENINGS
134 SECTION 707 CONCEALED SPACES
SECTION 708 SPRAY FIRE-RESISTANT MATERIALS AND INTUMESCENT FIRE-RESISTANT MATERIALS
136 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH IN EXISTING BUILDINGS
137 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
138 SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS
139 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
142 SECTION 806 NATURAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
SECTION 807 DECORATIVE MATERIALS AND ARTIFICIAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
144 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
146 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
147 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
149 SECTION 902 DEFINITIONS
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
151 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
154 TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE PROTECTION SYSTEMS
TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE PROTECTION SYSTEMS
157 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
161 SECTION 905 STANDPIPE SYSTEMS
163 SECTION 906 PORTABLE FIRE EXTINGUISHERS
164 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
TABLE 906.1—continued ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
165 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25 INCHa
166 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
176 TABLE 907.5.2.3.2 VISIBLE ALARMS
178 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
180 EQUATION 9-1
EQUATION 9-2
187 SECTION 910 SMOKE AND HEAT REMOVAL
EQUATION 9-3
EQUATION 9-4
188 SECTION 911 EXPLOSION CONTROL
189 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTSf
190 SECTION 912 FIRE DEPARTMENT CONNECTIONS
191 SECTION 913 FIRE PUMPS
SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
194 TABLE 914.8.3 HANGAR FIRE SUPPRESSION REQUIREMENTS
SECTION 915 CARBON MONOXIDE DETECTION
196 SECTION 916 GAS DETECTION SYSTEMS
197 SECTION 917 MASS NOTIFICATION SYSTEMS
198 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
199 SECTION 1003 GENERAL MEANS OF EGRESS
200 SECTION 1004 OCCUPANT LOAD
[BE] TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
201 [BE] TABLE 1004.5—continued MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
202 SECTION 1005 MEANS OF EGRESS SIZING
203 SECTION 1006 NUMBERS OF EXITS AND EXIT ACCESS DOORWAYS
204 [BE] TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
205 [BE] TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
[BE] TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
206 [BE] TABLE 1006.3.4(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
207 SECTION 1008 MEANS OF EGRESS ILLUMINATION
208 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
210 SECTION 1010 DOORS, GATES AND TURNSTILES
217 [BE] TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
218 [BE] TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
220 SECTION 1011 STAIRWAYS
224 SECTION 1012 RAMPS
225 SECTION 1013 EXIT SIGNS
226 SECTION 1014 HANDRAILS
227 SECTION 1015 GUARDS
229 SECTION 1016 EXIT ACCESS
230 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
[BE] TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
231 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
232 SECTION 1020 CORRIDORS
[BE] TABLE 1020.2 CORRIDOR FIRE-RESISTANCE RATING
[BE] TABLE 1020.3 MINIMUM CORRIDOR WIDTH
233 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
234 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
236 SECTION 1024 EXIT PASSAGEWAYS
237 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
238 SECTION 1026 HORIZONTAL EXITS
239 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
240 SECTION 1028 EXIT DISCHARGE
241 SECTION 1029 EGRESS COURTS
SECTION 1030 ASSEMBLY
242 [BE] TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
246 [BE] TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
248 SECTION 1031 EMERGENCY ESCAPE AND RESCUE
249 SECTION 1032 MAINTENANCE OF THE MEANS OF EGRESS
252 CHAPTER 11 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
253 TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa
259 SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS
261 TABLE 1104.9 REVOLVING DOOR SPEEDS
263 TABLE 1104.18 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
264 SECTION 1105 CONSTRUCTION REQUIREMENTS FOR EXISTING GROUP I-2
265 TABLE 1105.3 FLOOR LEVEL LIMITATIONS FOR GROUP I-2, CONDITION 2
TABLE 1105.4 INCIDENTAL USES IN EXISTING GROUP I-2 OCCUPANCIES
268 SECTION 1106 REQUIREMENTS FOR OUTDOOR OPERATIONS
270 CHAPTER 12 ENERGY SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 EMERGENCY AND STANDBY POWER SYSTEMS
272 SECTION 1204 PORTABLE GENERATORS
273 SECTION 1205 SOLAR PHOTOVOLTAIC POWER SYSTEMS
274 FIGURE 1205.4.1(1) LABEL FOR SOLAR PV SYSTEMS THAT REDUCE SHOCK HAZARD WITHIN ARRAY AND SHUT DOWN CONDUCTORS LEAVING ARRAY
275 FIGURE 1205.4.1(2) LABEL FOR SOLAR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY
SECTION 1206 STATIONARY FUEL CELL POWER SYSTEMS
276 SECTION 1207 ELECTRICAL ENERGY STORAGE SYSTEMS (ESS)
TABLE 1207.1.1 ENERGY STORAGE SYSTEM (ESS) THRESHOLD QUANTITIES
281 TABLE 1207.5 MAXIMUM ALLOWABLE QUANTITIES OF ELECTROCHEMICAL ESS
282 TABLE 1207.6 ELECTROCHEMICAL ESS TECHNOLOGY-SPECIFIC REQUIREMENTS
284 TABLE 1207.7 INDOOR ESS INSTALLATIONS
285 TABLE 1207.8 OUTDOOR ESS INSTALLATIONSa
286 TABLE 1207.9 SPECIAL ESS INSTALLATIONS
287 TABLE 1207.10 MOBILE ENERGY STORAGE SYSTEMS (ESS)
290 CHAPTERS 13 THROUGH 19 RESERVED
292 PART IV—SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20 AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE
293 SECTION 2005 PORTABLE FIRE EXTINGUISHERS
SECTION 2006 AIRCRAFT FUELING
298 SECTION 2007 HELISTOPS AND HELIPORTS
300 CHAPTER 21 DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 CLASSIFICATIONS
SECTION 2104 GENERAL REQUIREMENTS
301 SECTION 2105 OPERATING REQUIREMENTS
EQUATION 21-1
SECTION 2106 SPOTTING AND PRETREATING
302 SECTION 2107 DRY CLEANING SYSTEMS
SECTION 2108 FIRE PROTECTION
304 CHAPTER 22 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 DUST EXPLOSION PREVENTION
TABLE 2203.1 CRITICAL DEPTH LAYER
305 TABLE 2203.3.1.2 MINIMUM CONVEYING VELOCITIES
307 SECTION 2204 DUST EXPLOSION SCREENING TESTS
SECTION 2205 STANDARDS
TABLE 2205.1 EXPLOSION PROTECTION STANDARDS
308 CHAPTER 23 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
309 SECTION 2304 DISPENSING OPERATIONS
310 SECTION 2305 OPERATIONAL REQUIREMENTS
311 SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
315 SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
316 SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
318 TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
320 SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES
321 SECTION 2311 REPAIR GARAGES
322 TABLE 2311.6.2 TEMPERATURE COMPENSATED CYLINDER PRESSURE TABLEa
326 CHAPTER 24 FLAMMABLE FINISHES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS
328 SECTION 2404 SPRAY FINISHING
332 SECTION 2405 DIPPING OPERATIONS
333 SECTION 2406 POWDER COATING
334 SECTION 2407 ELECTROSTATIC APPARATUS
335 SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
336 SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS
338 CHAPTER 25 FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
SECTION 2507 WARNING SIGNS
340 CHAPTER 26 FUMIGATION AND INSECTICIDAL FOGGING
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FIRE SAFETY REQUIREMENTS
342 CHAPTER 27 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
SECTION 2702 DEFINITIONS
SECTION 2703 GENERAL SAFETY PROVISIONS
346 SECTION 2704 STORAGE
347 SECTION 2705 USE AND HANDLING
348 TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
349 TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
350 TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
352 CHAPTER 28 LUMBER YARDS AND AGRO-INDUSTRIAL, SOLID BIOMASS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
353 SECTION 2804 FIRE PROTECTION
SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIALS ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
354 SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIALS, FINES, COMPOST, SOLID BIOMASS FEEDSTOCK AND RAW PRODUCT ASSOCIATED WITH YARD WASTE, AGRO-INDUSTRIAL AND RECYCLING FACILITIES
SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER AND SOLID BIOFUEL PRODUCTS
355 SECTION 2810 OUTDOOR STORAGE OF PALLETS AT PALLET MANUFACTURING AND RECYCLING FACILITIES
356 CHAPTER 29 MANUFACTURE OF ORGANIC COATINGS
SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION
357 SECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
SECTION 2907 PROCESS PIPING
358 SECTION 2908 RAW MATERIALS IN PROCESS AREAS
SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS
360 CHAPTER 30 INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
361 SECTION 3007 OPERATION AND MAINTENANCE
362 CHAPTER 31 TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
364 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
365 SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
SECTION 3105 TEMPORARY SPECIAL EVENT STRUCTURES
366 SECTION 3106 OUTDOOR ASSEMBLY EVENTS
367 SECTION 3107 OPERATIONAL REQUIREMENTS
370 CHAPTER 32 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
371 SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION
372 TABLE 3203.8 EXAMPLES OF COMMODITY CLASSIFICATION
373 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
374 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
375 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
376 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
377 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
378 TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION
379 FIGURE 3203.9(1) EVALUATION BY VOLUME OF GROUP A EXPANDED PLASTICS IN MIXED COMMODITIES
FIGURE 3203.9(2) EVALUATION BY WEIGHT OF GROUP A EXPANDED PLASTICS IN MIXED COMMODITIES
380 EQUATION 32-1
EQUATION 32-2
EQUATION 32-3
SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
381 SECTION 3205 HOUSEKEEPING AND MAINTENANCE
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
382 TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
384 SECTION 3207 SOLID-PILED AND SHELF STORAGE
SECTION 3208 RACK STORAGE
385 TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 3209 AUTOMATED STORAGE
386 SECTION 3210 SPECIALTY STORAGE
388 CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
SECTION 3303 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
389 SECTION 3304 TEMPORARY HEATING EQUIPMENT
390 SECTION 3305 PRECAUTIONS AGAINST FIRE
391 SECTION 3306 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 3307 FLAMMABLE GASES
SECTION 3308 EXPLOSIVE MATERIALS
SECTION 3309 PORTABLE GENERATORS
SECTION 3310 FIRE REPORTING
SECTION 3311 ACCESS FOR FIRE FIGHTING
392 SECTION 3312 MEANS OF EGRESS
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3314 STANDPIPES
393 SECTION 3315 AUTOMATIC SPRINKLER SYSTEM
SECTION 3316 PORTABLE FIRE EXTINGUISHERS
SECTION 3317 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3318 SAFEGUARDING ROOFING OPERATIONS
394 CHAPTER 34 TIRE REBUILDING AND TIRE STORAGE
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
SECTION 3405 OUTDOOR STORAGE
395 SECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT
396 CHAPTER 35 WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
SECTION 3504 FIRE SAFETY REQUIREMENTS
397 SECTION 3505 GAS WELDING AND CUTTING
398 SECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
SECTION 3508 ACETYLENE GENERATORS
399 SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
SECTION 3510 HOT WORK ON FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS
400 CHAPTER 36 MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL PRECAUTIONS
SECTION 3604 FIRE PROTECTION EQUIPMENT
401 SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES
402 CHAPTER 37 COMBUSTIBLE FIBERS
SECTION 3701 GENERAL
SECTION 3702 DEFINITIONS
SECTION 3703 GENERAL PRECAUTIONS
SECTION 3704 LOOSE FIBER STORAGE
403 SECTION 3705 BALED STORAGE
404 CHAPTER 38 HIGHER EDUCATION LABORATORIES
SECTION 3801 GENERAL
SECTION 3802 DEFINITIONS
SECTION 3803 GENERAL SAFETY PROVISIONS
405 SECTION 3804 LABORATORY SUITE CONSTRUCTION
TABLE 3804.1.1 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR
406 SECTION 3805 NONSPRINKLERED LABORATORIES
407 TABLE 3805.4 DESIGN AND NUMBER OF CONTROL AREAS IN EXISTING NONSPRINKLERED LABORATORIES
SECTION 3806 EXISTING SPRINKLERED LABORATORIES
TABLE 3806.2.1 DESIGN AND NUMBER OF CONTROL AREAS IN EXISTING SPRINKLERED LABORATORIES
408 CHAPTER 39 PROCESSING AND EXTRACTION FACILITIES
SECTION 3901 GENERAL
SECTION 3902 DEFINITIONS
SECTION 3903 PROCESSING AND EXTRACTION
SECTION 3904 SYSTEMS AND EQUIPMENT
409 SECTION 3905 SAFETY SYSTEMS
412 CHAPTER 40 STORAGE OF DISTILLED SPIRITS AND WINES
SECTION 4001 GENERAL
SECTION 4002 DEFINITIONS
SECTION 4003 PRECAUTIONS AGAINST FIRE
413 SECTION 4004 STORAGE
SECTION 4005 FIRE PROTECTION
SECTION 4006 SIGNAGE
414 CHAPTERS 41 THROUGH 49 RESERVED
416 PART V—HAZARDOUS MATERIALS
CHAPTER 50 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 5001 GENERAL
419 SECTION 5002 DEFINITIONS
SECTION 5003 GENERAL REQUIREMENTS
420 TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
421 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
422 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa
423 TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
424 TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREAa
425 TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL
429 TABLE 5003.8.2 DETACHED BUILDING REQUIRED
TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
433 TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
434 SECTION 5004 STORAGE
435 TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
437 SECTION 5005 USE, DISPENSING AND HANDLING
439 TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
442 CHAPTER 51 AEROSOLS
SECTION 5101 GENERAL
SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
443 TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
444 TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
445 TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS, AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS
446 SECTION 5106 RETAIL DISPLAY
TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS, AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL DISPLAY AREAS
447 TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS
SECTION 5107 MANUFACTURING FACILITIES
448 CHAPTER 52 RESERVED
450 CHAPTER 53 COMPRESSED GASES
SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
SECTION 5303 GENERAL REQUIREMENTS
454 SECTION 5304 STORAGE OF COMPRESSED GASES
SECTION 5305 USE AND HANDLING OF COMPRESSED GASES
455 SECTION 5306 MEDICAL GASES
SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED
458 CHAPTER 54 CORROSIVE MATERIALS
SECTION 5401 GENERAL
SECTION 5402 DEFINITION
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE
460 CHAPTER 55 CRYOGENIC FLUIDS
SECTION 5501 GENERAL
SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS
462 SECTION 5504 STORAGE
TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
463 TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 5505 USE AND HANDLING
466 CHAPTER 56 EXPLOSIVES AND FIREWORKS
SECTION 5601 GENERAL
468 TABLE 5601.8.1(1) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES
TABLE 5601.8.1(2) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES
TABLE 5601.8.1(3) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVESa
469 SECTION 5602 DEFINITIONS
470 SECTION 5603 RECORD KEEPING AND REPORTING
SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING
471 TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
472 TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
473 TABLE 5604.5.2(1)—continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
474 TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARD
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4c
476 SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
477 TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
TABLE 5605.3—continued MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
479 SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
481 SECTION 5607 BLASTING
482 SECTION 5608 FIREWORKS DISPLAY
483 SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS
484 CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 5701 GENERAL
SECTION 5702 DEFINITIONS
485 SECTION 5703 GENERAL REQUIREMENTS
486 TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
487 TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
TABLE 5703.6.2 PIPING STANDARDS
489 SECTION 5704 STORAGE
500 TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
501 TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
502 TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
503 TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKSa
504 TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
505 TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
506 TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa
507 TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS
508 TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
509 SECTION 5705 DISPENSING, USE, MIXING AND HANDLING
510 TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1)
513 TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS
515 SECTION 5706 SPECIAL OPERATIONS
524 SECTION 5707 ON-DEMAND MOBILE FUELING OPERATIONS
528 CHAPTER 58 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS
529 SECTION 5804 STORAGE
SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS
530 SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS
531 SECTION 5808 HYDROGEN FUEL GAS ROOMS
534 CHAPTER 59 FLAMMABLE SOLIDS
SECTION 5901 GENERAL
SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
SECTION 5905 USE
SECTION 5906 MAGNESIUM
538 CHAPTER 60 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
539 SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
542 TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
544 SECTION 6005 OZONE GAS GENERATORS
546 CHAPTER 61 LIQUEFIED PETROLEUM GASES
SECTION 6101 GENERAL
SECTION 6102 DEFINITIONS
SECTION 6103 INSTALLATION OF EQUIPMENT
547 SECTION 6104 LOCATION OF LP-GAS CONTAINERS
SECTION 6105 PROHIBITED USE OF LP-GAS
SECTION 6106 DISPENSING AND OVERFILLING
SECTION 6107 SAFETY PRECAUTIONS AND DEVICES
548 TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS
SECTION 6108 FIRE PROTECTION
549 SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
550 TABLE 6109.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS
SECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE
SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES
552 CHAPTER 62 ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITION
SECTION 6203 GENERAL REQUIREMENTS
SECTION 6204 STORAGE
553 TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES
554 SECTION 6205 USE
556 CHAPTER 63 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS
557 TABLE 6303.1.4 STORAGE OF CLASS 1, 2 AND 3 OXIDIZER LIQUIDS AND SOLIDS
SECTION 6304 STORAGE
558 TABLE 6304.1.5(1) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.1.5(2) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDSFor
TABLE 6304.1.5(3) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.2.1 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
559 SECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE
562 CHAPTER 64 PYROPHORIC MATERIALS
SECTION 6401 GENERAL
SECTION 6402 DEFINITION
SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE
563 TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE
564 CHAPTER 65 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING
566 CHAPTER 66 UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
SECTION 6602 DEFINITION
SECTION 6603 GENERAL REQUIREMENTS
567 SECTION 6604 STORAGE
SECTION 6605 USE
568 CHAPTER 67 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
SECTION 6702 DEFINITION
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE
569 SECTION 6705 USE
570 CHAPTERS 68 THROUGH 79 RESERVED
572 PART VI—REFERENCED STANDARDS
CHAPTER 80 REFERENCED STANDARDS
AASHTO
AFSI
ANSI
API
573 ASCE/SEI
ASHRAE
ASME
574 ASSP
ASTM
575 BHMA
CA
CGA
576 CGR
CPSC
CSA
577 DOC
DOL
DOTn
DOTy
EN
578 FCC
FM
ICC
579 IIAR
IKECA
580 ISO
NEMA
NFPA
584 UL
587 USC
588 PART VII—APPENDICES
APPENDIX A BOARD OF APPEALS
SECTION A101 GENERAL
590 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
591 TABLE B105.1(1) REQUIRED FIRE FLOW FOR ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES
TABLE B105.1(2) REFERENCE TABLE FOR TABLES B105.1(1) AND B105.2
592 TABLE B105.2 REQUIRED FIRE FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES
SECTION B106 REFERENCED STANDARDS
TABLE B106.1 REFERENCED STANDARDS
594 APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 NUMBER OF FIRE HYDRANTS
TABLE C102.1 REQUIRED NUMBER AND SPACING OF FIRE HYDRANTSh
SECTION C103 FIRE HYDRANT SPACING
595 SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION C105 REFERENCED STANDARD
TABLE C105.1 REFERENCED STANDARD
596 APPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
597 TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
598 SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
SECTION D108 REFERENCED STANDARDS
TABLE D108.1 REFERENCED STANDARDS
600 APPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
604 SECTION E103 EVALUATION OF HAZARDS
605 SECTION E104 REFERENCED STANDARDS
TABLE E104.1 REFERENCED STANDARDS
606 APPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS
TABLE F102.1 REFERENCED STANDARDS
607 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
608 APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
609 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
610 APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
SECTION H102 HMIS
611 SECTION H103 EMERGENCY PLAN
SECTION H104 SECURITY
SECTION H105 REFERENCED STANDARDS
TABLE H105.1 REFERENCED STANDARDS
612 FIGURE H101.1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
613 FIGURE H101.2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
614 FIGURE H101.3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP
615 FIGURE H102.1 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INVENTORY REPORT
616 TABLE H102.1 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) SUMMARY REPORTa (Storageb Conditions)c
617 FIGURE H103.1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION III: EMERGENCY PLAN
618 APPENDIX I FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
619 SECTION I102 REFERENCED STANDARDS
TABLE I102.1 REFERENCED STANDARDS
620 APPENDIX J BUILDING INFORMATION SIGN
SECTION J101 GENERAL
FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN
622 SECTION J102 REFERENCED STANDARDS
TABLE J102.1 REFERENCED STANDARDS
624 APPENDIX K CONSTRUCTION REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
SECTION K101 GENERAL
SECTION K102 FIRE SAFETY REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
626 SECTION K103 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES
TABLE K103.1 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES
SECTION K104 MEANS OF EGRESS REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES
627 SECTION K105 REFERENCED STANDARDS
TABLE K105.1 REFERENCED STANDARDS
628 APPENDIX L REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS
SECTION L101 GENERAL
SECTION L102 DEFINITIONS
SECTION L103 PERMITS
SECTION L104 DESIGN AND INSTALLATION
630 SECTION L105 ACCEPTANCE TESTS
SECTION L106 INSPECTION, TESTING AND MAINTENANCE
SECTION L107 REFERENCED STANDARDS
TABLE L107.1 REFERENCED STANDARDS
632 APPENDIX M HIGH-RISE BUILDINGS—RETROACTIVE AUTOMATIC SPRINKLER REQUIREMENT
SECTION M101 SCOPE
SECTION M102 WHERE REQUIRED
SECTION M103 COMPLIANCE
634 APPENDIX N INDOOR TRADE SHOWS AND EXHIBITIONS
SECTION N101 GENERAL
SECTION N102 DEFINITIONS
SECTION N103 PUBLIC SAFETY FOR EVENTS
635 SECTION N104 INTERIOR FINISH AND DECORATIVE MATERIALS
SECTION N105 MULTIPLE-LEVEL BOOTHS
SECTION N106 COVERED BOOTHS
SECTION N107 DISPLAY AND STORAGE OF HAZARDOUS AND COMBUSTIBLE MATERIALS
636 SECTION N108 MEANS OF EGRESS
SECTION N109 REFERENCED STANDARDS
TABLE N109.1 REFERENCED STANDARDS
638 INDEX
670 RESOURCE A RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI)
672 RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS [RVI]
673 COPYRIGHT
674 TABLE OF CONTENTS
676 PREFACE
677 ABOUT THE INTERNATIONAL CODE COUMNCIL
678 1.0 INTRODUCTION
PURPOSE AND SCOPE
2.0 DEFINITIONS AND ACRONYMS
3.0 REMOTE VIRTUAL INSPECTION PROCESS
679 CUSTOMER: REQUESTING A REMOTE VIRTUAL INSPECTION
680 AHJ: SCHEDULING REMOTE VIRTUAL INSPECTION
681 CUSTOMER: PREPARE FOR REMOTE VIRTUAL INSPECTION
CUSTOMER: PREPARE TO RECEIVE REMOTE VIRTUAL INSPECTION CALL
682 WHAT TO EXPECT DURING THE INSPECTION
INSPECTION RESULTS
683 MAINTAINING RECORDS OF INSPECTIONS
4.0 TRANING AND COMMUNICATION
STAFF TRAINING
684 CUSTOMER/APPLICANT
ADDITIONAL CONSIDERATIONS
685 5.0 APPENDIX A (EXAMPLES OF POTENTIAL ACTIVITIES)
686 KEYS TO SUCCESS FOR REMOTE VIRTUAL INSPECTIONS
687 THE KEY STEPS TO A REMOTE VIRTUAL INSPECTION
688 ICC DIGITIAL CODES LIBRARY
689 RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS [RVI]
690 VALUABLE GUIDES TO CHANGES IN THE 2021 I-CODES
691 PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™)
692 ICC MEMBERSHIP
693 ICC LEARNING CENTER
ICC IFC 2021 1stptg
$86.13