Shopping Cart

No products in the cart.

ICC IFC Commentary 2012

$81.25

International Fire Code and Commentary

Published By Publication Date Number of Pages
ICC 2012 1343
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This comprehensive publication provides a convenient reference for regulations in the 2012 International Fire Code

PDF Catalog

PDF Pages PDF Title
1 2012 IFC® CODE AND COMMENTARY
2 2012 IFC® CODE AND COMMENTARY TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 ARRANGEMENT AND FORMAT OF THE 2012 IFC
7 2012 IFC CHAPTER REORGANIZATION
10 LEGISLATION
16 PART I—ADMINISTRATIVE
CHAPTER 1: SCOPE AND ADMINISTRATION
18 FIGURE 1(2) SYSTEMS APPROACHES TO CODE COMPLIANCE
FIGURE 1(3) TYPES OF TORTS
19 FIGURE 1(4) MARKMAN’S SIX RULES
20 FIGURE 1(5) HOW BUILDINGS, PEOPLE AND FIRE INTERACT
21 FIGURE 1(6) NORMAL PLANNING APPROACH
22 PART 1—GENERAL PROVISIONS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
23 SECTION 102 APPLICABILITY
26 PART 2—ADMINISTRATIVE PROVISIONS
SECTION 103 DEPARTMENT OF FIRE PREVENTION
27 SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES
31 SECTION 105 PERMITS
37 TABLE 105.6.8 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.6.10 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
39 TABLE 105.6.20 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
TABLE 105.6.20—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
44 SECTION 106 INSPECTIONS
45 SECTION 107 MAINTENANCE
46 SECTION 108 BOARD OF APPEALS
47 SECTION 109 VIOLATIONS
49 SECTION 110 UNSAFE BUILDINGS
50 SECTION 111 STOP WORK ORDER
SECTION 112 SERVICE UTILITIES
51 SECTION 113 FEES
BIBLIOGRAPHY
52 CHAPTER 2: DEFINITIONS
SECTION 201 GENERAL
53 SECTION 202 GENERAL DEFINITIONS
55 FIGURE 202-A1 EXAMPLE OF AIR-INFLATED MEMBRANE STRUCTURE
FIGURE 202-A2 AIR-SUPPORTED MEMBRANE STRUCTURE—SWIMMING POOL COVER
56 FIGURE 202-A3 AISLES AND AISLE ACCESSWAYS
58 FIGURE 202-A4 PROPERTIES OF FUEL ETHANOL
61 FIGURE 202-B1 ARRANGEMENT OF BARRICADE
66 FIGURE 202-C1 EXAMPLE OF A FREE-STANDING MEMBRANE-COVERED CANOPY
FIGURE 202-C2 EXAMPLE OF A CANOPY SUPPORTED BY A BUILDING AND STANCHION
FIGURE 202-C3 EXAMPLE OF A FREE-STANDING MOTOR FUEL-DISPENSING FACILITY CANOPY
76 FIGURE 202-D1 TYPICAL DIP TANK INSTALLATION
FIGURE 202-D2 BALANCED DOOR
77 FIGURE 202-D3 EXAMPLE OF DRAFTSTOPPING
78 FIGURE 202-D4 EXAMPLE OF DRAFTSTOPPING
82 FIGURE 202-E1 EXIT
FIGURE 202-E2 EXIT ACCESS
83 FIGURE 202-E3 EXIT DISCHARGE
FIGURE 202-E4 EXIT DISCHARGE, LEVEL OF
84 FIGURE 202-E5 EXIT HORIZONTAL
85 FIGURE 202-E6 COMPARISON OF CLASSIFICATION SYSTEMS FOR EXPLOSIVE MATERIALS
90 FIGURE 202-F1 EXAMPLES OF FIRE-RESISTANT JOINT SYSTEMS
94 FIGURE 202-F2 FLAMMABLE SOLID TEST METHOD
FIGURE 202-F3 MELTING AND IGNITION TEMPERATURES OF SELECTED PURE METALS IN SOLID FORM
95 FIGURE 202-F4 COMMON FLAMMABLE SOLIDS AND THEIR PROPERTIES
97 FIGURE 202-F5 FLUE SPACES
101 FIGURE 202-H1 HAZARDOUS PRODUCTION MATERIALS (HPM) USED IN THE MANUFACTURE OF SEMICONDUCTORS
103 FIGURE 202-H2 HIGH-RISE BUILDING
104 FIGURE 202-H3 COMMON HIGHLY TOXIC MATERIALS AND THEIR HAZARDS
106 FIGURE 202-H4 TYPICAL WELDING CHART
110 FIGURE 202-L1 LIQUID OXYGEN AMBULATORY CONTAINER
FIGURE 202-L2 LIQUID OXYGEN HOME CARE CONTAINER
115 FIGURE 202-M1 METAL HYDRIDE STORAGE CONTAINER AND ITS METAL HYDRIDE CONTENT
116 FIGURE 202-N1 NESTING OF CYLINDERS
118 FIGURE 202-O1 ACCESSORY ASSEMBLY USE LIMITED BY OCCUPANT LOAD
119 FIGURE 202-O2 ACCESSORY ASSEMBLY USE GREATER THAN 10 PERCENT OF FLOOR AREA BUT LESS THAN 750 FT.2
120 FIGURE 202-O3 GROUP A-1
FIGURE 202-O4 GROUP A-1
121 FIGURE 202-O5 GROUP A-1
142 FIGURE 202-O6 COMPARISON OF HYDROGEN PEROXIDE STRUCTURE WITH BENZOYL PEROXIDE
FIGURE 202-O7 COMPARISON OF ORGANIC PEROXIDE CLASSIFICATION SYSTEMS
146 FIGURE 202-P1 INSULATED HORIZONTAL PRESSURE VESSEL
147 FIGURE 202-P2 VERTICAL PRESSURE VESSEL
152 FIGURE 202-S1 TYPE I SAFETY CAN
FIGURE 202-S2 TYPE II SAFETY CAN
153 FIGURE 202-S3 TYPICAL COMPONENTS OF AN HPM FACILITY
157 FIGURE 202-S4 TYPICAL PAINT SPRAY BOOTH
161 FIGURE 202-T1 EXAMPLE OF TENT STRUCTURE
163 FIGURE 202-T2 SPEED PILLOW TRAFFIC CALMING DEVICE
FIGURE 202-T3 ROUND-ABOUT TRAFFIC CALMING DEVICE
165 FIGURE 202-T4 TUBE TRAILER
167 BIBLIOGRAPHY
168 PART II—GENERAL SAFETY PROVISIONS
CHAPTER 3: GENERAL REQUIREMENTS
FIGURE 3 THE FIRE SAFETY CONCEPTS TREE
169 SECTION 301 GENERAL
SECTION 302 DEFINITIONS
SECTION 303 ASPHALT KETTLES
170 SECTION 304 COMBUSTIBLE WASTE MATERIAL
173 SECTION 305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
174 SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
176 SECTION 308 OPEN FLAMES
180 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
FIGURE 309.2 BATTERY CHARGERS FOR POWERED INDUSTRIAL TRUCKS
181 SECTION 310 SMOKING
FIGURE 310.3 NO SMOKING SIGN
182 SECTION 311 VACANT PREMISES
184 SECTION 312 VEHICLE IMPACT PROTECTION
185 FIGURE 312.2(1 )PUMP ISLAND PROTECTION
FIGURE 312.2(2) GUARD POST INSTALLATION IN PUBLIC REPAIR GARAGE
186 FIGURE 312.3 ONE METHOD OF EQUIPMENT PROTECTION
SECTION 313 FUELED EQUIPMENT
187 SECTION 314 INDOOR DISPLAYS
FIGURE 314.4 INDOOR CAR DISPLAY
188 SECTION 315 GENERAL STORAGE
190 SECTION 316 HAZARDS TO FIRE FIGHTERS
191 FIGURE 316.2.1 SHAFTWAY SIGNAGE
193 SECTION 317 ROOFTOP GARDENS AND LANDSCAPED ROOFS
194 SECTION 318 LAUNDRY CARTS
195 BIBLIOGRAPHY
196 CHAPTER 4: EMERGENCY PLANNING AND PREPAREDNESS
198 SECTION 401 GENERAL
199 SECTION 402 DEFINITIONS
200 SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS
201 SECTION 404 FIRE SAFETY AND EVACUATION PLANS
204 SECTION 405 EMERGENCY EVACUATION DRILLS
205 TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
206 SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
207 SECTION 407 HAZARD COMMUNICATION
208 SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS
213 FIGURE 408.7.4 TACTILE CODING OF INSTITUTIONAL KEYS
216 BIBLIOGRAPHY
218 PART III—BUILDING AND EQUIPMENT DESIGN FEATURES
CHAPTER 5: FIRE SERVICE FEATURES
SECTION 501 GENERAL
219 SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
220 FIGURE 503.1.1(1) FIRE DEPARTMENT ACCESS—LARGE BUILDING
FIGURE 503.1.1(2) FIRE DEPARTMENT ACCESS ON TWO SIDES
221 FIGURE 503.1.1(3) SMALL BUILDING ACCESS
224 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
225 SECTION 505 PREMISES IDENTIFICATION
SECTION 506 KEY BOXES
FIGURE 506.1(1) SURFACE-MOUNTED KEY BOX
226 FIGURE 506.1(2) RECESSED-MOUNTED KEY BOX
SECTION 507 FIRE PROTECTION WATER SUPPLIES
228 FIGURE 507.5.1(1) HYDRANT LAYOUT TO MINIMIZE HOSE RUN
FIGURE 507.5.1(2) HYDRANT LOCATION—GROUP R-3 AND U
229 FIGURE 507.5.1(3) ACCEPTABLE HYDRANTLOCATION WITH SPRINKLERS
230 FIGURE 507.5.5 HYDRANT CLEARANCE
FIGURE 507.5.6 HYDRANT IMPACT PROTECTION
SECTION 508 FIRE COMMAND CENTER
232 SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS
233 SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
237 BIBLIOGRAPHY
238 CHAPTER 6: BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
239 SECTION 603 FUEL-FIRED APPLIANCES
242 FIGURE 603.4.2 PORTABLE OUTDOOR GAS-FIRED HEATING APPLIANCE/PATIO HEATER
245 SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS
251 FIGURE 604.5 TYPICAL BATTERY UNIT EMERGENCY LIGHTING
252 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
253 FIGURE 605.3 REQUIRED CLEARANCES
FIGURE 605.4 TYPICAL MULTIPLUG ADAPTER AND POWER TAP
254 FIGURE 605.5 EXAMPLES OF UNACCEPTABLE PRACTICES
257 FIGURE 605.11 BASIC SCHEMATIC OF A PHOTOVOLTAIC SYSTEM
258 FIGURE 605.11.1.3 PV ARRAY DISCONNECT SWITCHES
259 FIGURE 605.11.3.2 INSTALLATION OF A PV ARRAY ON A SINGLE-FAMILY DWELLING
261 SECTION 606 MECHANICAL REFRIGERATION
266 SECTION 607 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS
267 FIGURE 607.4 TYPICAL ELEVATOR KEY BOX
268 TABLE 608.1 BATTERY REQUIREMENTS
269 SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS
272 SECTION 609 COMMERCIAL KITCHEN HOODS
273 TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
274 SECTION 610 COMMERCIAL KITCHEN COOKING OIL STORAGE
275 FIGURE 610.2 COOKING OIL STORAGE TANK AND RECOVERY CART
FIGURE 610.1 COOKING OIL FLASH POINT AND IGNITION TEMPERATURES
276 BIBLIOGRAPHY
278 CHAPTER 7: FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
279 SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
282 SECTION 704 FLOOR OPENINGS AND SHAFTS
BIBLIOGRAPHY
284 CHAPTER 8: INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
285 SECTION 802 DEFINITIONS
SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
286 FIGURE 803.1.1(1) ASTM E 84 TUNNEL TEST
FIGURE 803.1.1(2) FLAME IN TUNNEL TEST
FIGURE 803.1.1(3) TYPICAL FLAME SPREAD OF COMMON MATERIALS
287 FIGURE 803.1.2(1) ROOM CORNER TEST
FIGURE 803.1.2(2) FLAME IN ROOM CORNER TEST
288 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
290 FIGURE 803.4 APPLIED FLAME-RETARDANT COATINGS
294 FIGURE 803.7.3(1) FOAM PLASTIC DECORATIVE TRIM COVERAGE AREA
FIGURE 803.7.3(2) MAXIMUM DIMENSIONS—FOAM PLASTIC TRIM
295 SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS
296 FIGURE 804.3.1 RADIANT FLOOR PANEL TEST (NFPA 253)
297 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
298 FIGURE 805.1 EFFECT OF LOCATION OF FIRE
299 FIGURE 805.1.1.2(1) TYPICAL FIRE TEST SETUP
300 FIGURE 805.1.1.2(2) STEADY VERSUS UNSTEADY FIRES
305 SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
FIGURE 806.1(1) GRAPH OF HEAT RELEASE RATE VERSUS TIME FOR TEST NUMBER 3
306 FIGURE 806.1(2) SUMMARY OF TREE PARAMETERS
307 SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
311 FIGURE 807.4.3.2 ARTWORK COVERAGE AREA EXAMPLE
312 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
313 BIBLIOGRAPHY
314 CHAPTER 9: FIRE PROTECTION SYTEMS
SECTION 901 GENERAL
318 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
321 SECTION 902 DEFINITIONS
322 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
323 FIGURE 903.2 SUMMARY OF OCCUPANCY-RELATED AUTOMATIC SPRINKLER THRESHOLDSa
328 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
333 FIGURE 903.2.11.1 SPACING OF OPENINGS IN STORIES OR BASEMENTS
334 FIGURE 903.2.11.1(1) OPENINGS IN STORIES OR BASEMENTS Less than 75 feet from any point to an opening
FIGURE 903.2.11.1(2) OPENINGS IN STORIES OR BASEMENTS More than 75 feet from any point to an opening
335 FIGURE 903.2.11.1(3) OPENINGS IN STORIES OR BASEMENTS Less than 75 feet from any point to an opening
FIGURE 903.2.11.1(4) OPENINGS IN STORIES OR BASEMENTS
337 TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
338 TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE SUPPRESSION SYSTEMS
FIGURE 903.3.1 NFPA 13, NFPA 13R, NFPA 13D SYSTEMS
339 FIGURE 903.3 SAMPLE SPRINKLER SYSTEM DRAWING AND DATA SUBMITTALS
340 FIGURE 903.3.1.1 TYPICAL WET PIPE SYSTEM
347 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
348 FIGURE 904.1.1 PERSONNEL QUALIFICATION REQUIREMENTS BY TYPE OF FIRE-EXTINGUISHING AGENT
358 SECTION 905 STANDPIPE SYSTEMS
360 FIGURE 905.3.1(1) HEIGHT THRESHOLD FOR STANDPIPES
361 FIGURE 905.3.1(2) HEIGHT REQUIREMENTS FOR STANDPIPES
367 SECTION 906 PORTABLE FIRE EXTINGUISHERS
368 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
370 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCHa
372 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
375 FIGURE 907.2 SUMMARY OF MANUAL FIRE ALARM AND AUTOMATIC SMOKE DETECTION SYSTEM THRESHOLDS
388 FIGURE 907.2.11.2 LOCATION OF SMOKE ALARMS IN A DWELLING
399 TABLE 907.5.2.3.3 VISIBLE ALARMS
404 SECTION 908 EMERGENCY ALARM SYSTEMS
406 SECTION 909 SMOKE CONTROL SYSTEMS
409 FIGURE 909.4.1 STACK EFFECT
413 EQUATION 9-1
414 EQUATION 9-2
415 FIGURE 909.8(1) SMOKE LAYER INTERFACE IN AN ATRIUM
416 FIGURE 909.8(2) AXISYMMETRICAL PLUME
FIGURE 909.8(3) BALCONY SPILL PLUME
417 FIGURE 909.8(4) WINDOW PLUME
FIGURE 909.8(5) PLUGHOLING
418 FIGURE 909.8.1(1) EXAMPLE OF CRITICAL LEVEL OF SMOKE
FIGURE 909.8.1(2) SMOKE LAYER INTERFACE
421 EQUATION 9-3
430 SECTION 910 SMOKE AND HEAT VENTS
432 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
434 FIGURE 910.3.4 SMOKE AND HEAT VENT SPACING
435 EQUATION 9-4
436 SECTION 911 EXPLOSION CONTROL
437 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
439 SECTION 912 FIRE DEPARTMENT CONNECTIONS
440 FIGURE 912.3.1 LOCKING FDC CAPS
441 FIGURE 912.4 FIRE DEPARTMENT CONNECTION WITH SIGN
SECTION 913 FIRE PUMPS
443 SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
449 TABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTSa,b,c
451 BIBLIOGRAPHY
452 CHAPTER 10: MEAN OF EGRESS
453 SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
454 SECTION 1003 GENERAL MEANS OF EGRESS
456 FIGURE 1003.3.1(1) DOOR CLOSER HEADROOM PROTRUSIONS FOR WALKING SURFACES
FIGURE 1003.3.1(2) REDUCED VERTICAL CLEARANCE
457 FIGURE 1003.3.2(1) POST-MOUNTED OBJECTS
FIGURE 1003.3.2(2) POST-MOUNTED PROTRUDING OBJECTS
458 FIGURE 1003.3.3 EXAMPLES OF HORIZONTAL PROJECTIONS
459 FIGURE 1003.5 ELEVATION CHANGE
460 SECTION 1004 OCCUPANT LOAD
FIGURE 1004.1.1 COMBINED OCCUPANT LOAD FOR EGRESS DESIGN
462 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
463 FIGURE 1004.1.2 TYPICAL NET FLOOR AREA OCCUPANT LOAD CALCULATION
464 FIGURE 1004.3 EXAMPLE OF OCCUPANT LOAD LIMIT SIGN
465 FIGURE 1004.4 TYPICAL FIXED SEATING
466 SECTION 1005 MEANS OF EGRESS SIZING
469 FIGURE 1005.6(1) EGRESS CONVERGENCE AT FIRST STORY
FIGURE 1005.6(2) EGRESS CONVERGENCE AT INTERMEDIATE LEVEL
470 FIGURE 1005.6(3) NO EGRESS CONVERGENCE
FIGURE 1005.7.1 TYPICAL DOOR RESTRICTIONS INTO PASSAGEWAY, AISLE AND CORRIDOR WIDTH
471 SECTION 1006 MEANS OF EGRESS ILLUMINATION
473 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
476 FIGURE 1007.2.1 ELEVATOR REQUIRED FOR ACCESSIBLE MEANS OF EGRESS
478 FIGURE 1007.3(1) ACCESSIBLE MEANS OF EGRESS STAIRWAY WITH ENLARGED STORY-LEVEL LANDING
479 FIGURE 1007.3(2) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM AN AREA OF REFUGE
480 FIGURE 1007.3(3) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM A HORIZONTAL EXIT
482 FIGURE 1007.6 SEPARATE TRAVEL DISTANCES TO AN AREA OF REFUGE
485 FIGURE 1007.7.3 EXTERIOR AREA OF RESCUE ASSISTANCE—PLAN VIEW
486 FIGURE 1007.7.4 EXTERIOR AREA OF RESCUE ASSISTANCE—ELEVATION
488 SECTION 1008 DOORS, GATES AND TURNSTILES
489 FIGURE 1008.1.1(1) TYPICAL DOOR OPENING CLEARANCE
490 FIGURE 1008.1.1(2) TYPICAL DOOR OPENING CLEARANCE WITH PANIC HARDWARE
493 FIGURE 1008.1.4.1(1) REVOLVING DOORS IN BOOKFOLD POSITION
494 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
FIGURE 1008.1.4.1(2) TYPICAL REVOLVING DOOR/SIDE SWINGING DOOR ARRANGEMENT
497 FIGURE 1008.1.5 DOOR LANDINGS
498 FIGURE 1008.1.7(1) VERTICAL CHANGES IN LEVEL
FIGURE 1008.1.7(2) BEVELED CHANGES IN LEVEL
499 FIGURE 1008.1.7(3) BEVELED CHANGES IN LEVEL
FIGURE 1008.1.7(4) DOOR THRESHOLD HEIGHT LIMITATIONS
FIGURE 1008.1.8(1) SPACING OF DOORS IN SERIES
500 FIGURE 1008.1.8(2) SPACING OF DOORS IN SERIES
FIGURE 1008.1.9.1 DOOR HARDWARE
502 FIGURE 1008.1.9.3 SURFACE AND FLUSH BOLT LOCATIONS
503 FIGURE 1008.1.9.4 TYPICAL MANUAL BOLT HARDWARE
508 FIGURE 1008.1.10.1 EXAMPLES OF TYPICAL PANIC HARDWARE
509 FIGURE 1008.1.10.1—continued EXAMPLES OF TYPICAL PANIC HARDWARE
511 SECTION 1009 STAIRWAYS
513 FIGURE 1009.3 DRAFT CURTAIN, EXCEPTIONS 3 AND 4
517 FIGURE 1009.5(1) STAIRWAY HEADROOM REQUIREMENTS
518 FIGURE 1009.5(2) EXAMPLE OF SECTION 1009.2, EXCEPTION 2
519 FIGURE 1009.7.1 TREAD DEPTH MEASUREMENT
520 FIGURE 1009.7.2 TREAD/RISER DIMENSIONS
521 FIGURE 1009.7.3 STAIR WINDERS WITHIN A DWELLING
522 FIGURE 1009.7.4(1) CONSISTENTLY SHAPED WINDERS
523 FIGURE 1009.7.4(2) SLOPED LANDING
524 FIGURE 1009.7.5.1 TREAD/RISER PROFILE (SOLID RISER)
FIGURE 1009.7.5.3 TREAD/RISER PROFILE (OPEN RISER
525 FIGURE 1009.8(1) TYPICAL LANDING DIMENSIONS STRAIGHT-RUN STAIRWAY
FIGURE 1009.8(2) TYPICAL LANDING DIMENSIONS STRAIGHT-RUN STAIRWAY
526 FIGURE 1009.8(3) REVERSING RUN STAIRWAY
FIGURE 1009.8(4) DOOR CLEARANCE REQUIREMENTS IN STAIRWAY
527 FIGURE 1009.9.1 OPEN TREAD IN ACCORDANCE WITH EXCEPTION 1
528 FIGURE 1009.10 STAIRWAY RISE LIMITATION
529 FIGURE 1009.11 CURVED STAIRWAYS—MINIMUM DIMENSIONAL REQUIREMENTS
FIGURE 1009.12 SPIRAL STAIRWAYS
531 FIGURE 1009.13 TYPICAL ALTERNATING TREAD DEVICE
FIGURE 1009.14 TYPICAL SHIP LADDER
532 FIGURE 1009.15 EXAMPLE OF SECTION 1009.15, EXCEPTION 3
533 SECTION 1010 RAMPS
534 FIGURE 1010.3 TYPICAL MEANS OF EGRESS RAMP
536 FIGURE 1010.6.3 DOORWAY OPENING ONTO LANDING
FIGURE 1010.7 RAMP LANDINGS
538 FIGURE 1010.9(1) RAMP WITH HANDRAIL AT WALL
FIGURE 1010.9(2) RAMP WITH HANDRAIL AND BARRIER
539 FIGURE 1010.9(3) RAMP WITH HANDRAIL AND CURB
FIGURE 1010.9(4) RAMP WITH HANDRAIL AND GUARD
540 FIGURE 1010.10.1 EDGE PROTECTION
541 SECTION 1011 EXIT SIGNS
FIGURE 1011.1 EXIT SIGNS WITHIN AN EXIT ENCLOSURE
543 FIGURE 1011.6.1 MINIMUM SIZES OF EXIT SIGNS
544 SECTION 1012 HANDRAILS
545 FIGURE 1012.2 HANDRAIL REQUIREMENTS
546 FIGURE 1012.3.1 EXAMPLE OF TYPE I ALTERNATIVE HANDRAIL CONFIGURATION
547 FIGURE 1012.3.2 EXAMPLES OF TYPE II HANDRAIL CONFIGURATIONS
548 FIGURE 1012.4(1) EXAMPLES OF PROHIBITED HANDRAIL DESIGNS
FIGURE 1012.4(2) REDUCED BRACKET EXTENSIONS EXAMPLE PER SECTION 1012.4, EXCEPTION 3
550 FIGURE 1012.8(1) TYPICAL HANDRAIL ARRANGEMENT
FIGURE 1012.8(2) PROJECTION OF HANDRAIL
551 SECTION 1013 GUARDS
FIGURE 1012.9 HANDRAILS FOR MONUMENTAL STAIRS
552 FIGURE 1013.2(1) OPEN-SIDED WALKING AREA
FIGURE 1013.2(2) DROP OFF MEASUREMENTS AND GUARD HEIGHT
553 FIGURE 1013.2.1 GUARD SYSTEM WITH GLAZING
554 FIGURE 1013.2(3) DROP OFF MEASUREMENTS AND GUARD HEIGHTS FOR 2- AND 3-STORY GROUP R-3 AND R-2
FIGURE 1013.3 GUARD HEIGHT
555 FIGURE 1013.4(1) GUARD OPENING LIMITATIONS
556 FIGURE 1013.4(2) EXAMPLE OF GUARD WITH HORIZONTAL MEMBERS
FIGURE 1013.7 PROTECTION AT ROOF-HATCH OPENING
557 SECTION 1014 EXIT ACCESS
559 FIGURE 1014.2(1) EGRESS PROHIBITED THROUGH GROUP H AREAS
FIGURE 1014.2(2) EGRESS THROUGH ADJOINING ROOMS AND SPACES
560 FIGURE 1014.3 COMMON PATH OF EGRESS TRAVEL
561 TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
562 TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
564 FIGURE 1015.2.1(1) EXAMPLES OF REMOTENESS BETWEEN EXITS OR EXIT ACCESS DOORS FROM A ROOM OR BUILDING
FIGURE 1015.2.1(2) REMOTENESS OF EXITS INTERCONNECTING BY A 1-HOUR FIRE-RESISTANCE-RATED CORRIDOR
565 FIGURE 1015.2.1(3) REMOTENESS OF EXITS IN A BUILDING WITH AN AUTOMATIC SPRINKLER SYSTEM
FIGURE 1015.2.1(4) REMOTE LOCATION OF EXIT ACCESS DOORS (ADJOINING ROOMS)
567 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
568 FIGURE 1016.3(1) LENGTH OF EXIT ACCESS TRAVEL
FIGURE 1016.3(2) MEASURING TRAVEL DISTANCE USING RECTILINEAR APPROACH
569 SECTION 1017 AISLES
570 FIGURE 1017.3 AISLES AND AISLE ACCESSWAYS IN MERCANTILE
571 SECTION 1018 CORRIDORS
572 TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
FIGURE 1018.1 APPLICATION OF TABLE 1018.1
573 TABLE 1018.2 MINIMUM CORRIDOR WIDTH
575 FIGURE 1018.4(1) ALLOWABLE DEAD-END CONDITIONS
FIGURE 1018.4(2) CORRIDOR LENGTH/WIDTH RATIO FOR DEAD-END CONSIDERATIONS
577 FIGURE 1018.6(1) CORRIDOR CONTINUITY—EXAMPLE 1
578 FIGURE 1018.6(2) CORRIDOR CONTINUITY—EXAMPLE 2
FIGURE 1018.6(3) CORRIDOR CONTINUITY—EXAMPLE 3
579 FIGURE 1018.6(4) ELEVATOR LOBBY/CORRIDOR OPTION 1
SECTION 1019 EGRESS BALCONIES
580 FIGURE 1018.6(5) ELEVATOR LOBBY/CORRIDOR OPTION 2
FIGURE 1018.6(6) ELEVATOR LOBBY/CORRIDOR OPTION 3
581 SECTION 1020 EXITS
FIGURE 1019.2 EGRESS BALCONIES
582 SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION
583 FIGURE 1021.1 NUMBER OF EXITS
586 FIGURE 1021.2(1) EXAMPLE 1 OF EXCEPTION 7—NOT PERMITTED
FIGURE 1021.2(2) EXAMPLE 2 OF EXCEPTION 7—PERMITTED
587 FIGURE 1021.2(3) EXAMPLE OF SINGLE-EXIT APARTMENT BUILDING
FIGURE 1021.2(4) EXAMPLE OF SINGLE-EXIT APARTMENT WITHIN A TWO-EXIT BUILDING
TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
588 TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
589 FIGURE 1021.2.1 STORIES WITH ONE EXIT
590 FIGURE 1021.2.3 MULTISTORY DWELLING UNITS
591 SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
596 FIGURE 1022.7(1) EXAMPLES OF EXTERIOR WALL PROTECTIVES
597 FIGURE 1022.7(2) EXTERIOR WALL PROTECTION
598 FIGURE 1022.8 EXAMPLE OF DISCHARGE IDENTIFICATION
600 FIGURE 1022.10.2(1) TYPICAL SMOKEPROOF ENCLOSURE ENTRY
FIGURE 1022.10.2(2) TYPICAL SMOKEPROOF ENCLOSURE WITH OPEN BALCONY ARRANGEMENT
601 SECTION 1023 EXIT PASSAGEWAYS
FIGURE 1023.1 ARRANGEMENT FOR LOBBY AND PASSAGEWAY
603 SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
604 FIGURE 1024.2.1 LEADING EDGE OF STEP AND LANDING
605 FIGURE 1024.2.3 HANDRAIL MARKINGS
FIGURE 1024.2.4.1 PERIMETER DEMARCATION LINES—FLOOR-MOUNTED OPTION
606 FIGURE 1024.2.4.2 PERIMETER DEMARCATION LINES—WALL-MOUNTED OPTION
FIGURE 1024.2.4.3 PERIMETER DEMARCATION LINES—OPTIONS AT DOORS INTO EXIT ENCLOSURES
607 FIGURE 1024.2.5 OBSTACLE MARKINGS
FIGURE 1024.2.6.1 EMERGENCY EXIT SYMBOL
608 FIGURE 1024.2.6 EXAMPLES OF EXIT DOOR TO EXTERIOR OPTIONS
609 SECTION 1025 HORIZONTAL EXITS
610 FIGURE 1025.1 TYPICAL HORIZONTAL EXITS
612 FIGURE 1025.4 REFUGE AREA EXCEPTION
SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
613 FIGURE 1026.3 EXTERIOR STAIRWAY
614 FIGURE 1026.5 EXTERIOR BALCONY AND STAIRWAY ADJACENT TO LOT LINE
616 FIGURE 1026.6(1) PROTECTION OF EXTERIOR STAIRWAYS
617 FIGURE 1026.6(2) EXTERIOR BALCONY WITH REMOTE STAIRWAYS
FIGURE 1026.6(3) EXAMPLE OF EXCEPTION 4
618 SECTION 1027 EXIT DISCHARGE
619 FIGURE 1027.1(1) PROTECTION OF LOBBY WITH AN EXIT DISCHARGE
620 FIGURE 1027.1(2) VESTIBULE WITH EXIT DISCHARGE
FIGURE 1027.1(3) SEPARATION DETAILS FOR VESTIBULE WITH EXIT DISCHARGE
622 SECTION 1028 ASSEMBLY
623 FIGURE 1028.2 GROUP A-1 WITH WAITING SPACE
625 FIGURE 1028.6.1(1) COMPUTATION OF WIDTH FOR STEPPED AISLES
FIGURE 1028.6.1(2) COMPUTATION OF WIDTH FOR LEVEL, SLOPED OR RAMPED AISLES
626 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
627 FIGURE 1028.6.2.2(1) ROOF HEIGHT (CONVEX DOME ROOF)
628 FIGURE 1028.6.2.2(2) ROOF HEIGHT (CONCAVE SUSPENDED ROOF)
FIGURE 1028.6.2.3(1) INDOOR SEATING SPRINKLERED AREAS (CONVEX DOME ROOF)
629 FIGURE 1028.6.2.3(2) INDOOR SEATING SPRINKLERED AREAS (CONCAVE SUSPENDED ROOF)
631 FIGURE 1028.8.1 PATH THROUGH ADJACENT ROWS
632 FIGURE 1028.9.2 TYPICAL AISLE CATCHMENTS
633 FIGURE 1028.9.3 COMPUTATION OF EXIT PASSAGE FOR CONVERGING AISLES
634 FIGURE 1028.9.4 AISLE WITH OPPOSITE EXITS
635 FIGURE 1028.9.5 TYPICAL BALCONY ARRANGEMENT
FIGURE 1028.10.1 AISLE AND AISLE ACCESSWAY MEASUREMENT WITH SEATING AND TABLES
636 FIGURE 1028.10.1.1 ACCESS FOR TABLES AND SEATING
637 FIGURE 1028.10.2 MINIMUM REQUIRED ROW WIDTH CLEARANCE FOR AISLE ACCESSWAYS
638 TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
FIGURE 1028.10.2.1 TYPICAL DUAL ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH
FIGURE 1028.10.2.2 TYPICAL SINGLE ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH
640 FIGURE 1028.11.1 TYPICAL SEATING PLATFORMS ALSO USED AS STEPPING AISLES
FIGURE 1028.11.2 TYPICAL RISER CONSTRUCTION IN STEPPED AISLES
642 FIGURE 1028.13 TYPICAL RAILING FOR RAMPED AISLES WITH RAILING IN THE AISLE
FIGURE 1028.13.1 DISCONTINUOUS AISLE HANDRAILS
643 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
644 FIGURE 1028.14.2 TYPICAL BALCONY GUARDS AT FASCIA
645 FIGURE 1029.2 EMERGENCY ESCAPE WINDOW
646 FIGURE 1029.5 WINDOW WELLS EMERGENCY ESCAPE WINDOW
647 SECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS
649 BIBLIOGRAPHY
652 CHAPTER 11: CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 1101 GENERAL
653 SECTION 1102 DEFINITIONS
SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
654 TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa
655 FIGURE 1103.3 STACK EFFECT AND SMOKE MIGRATION VIA VERTICAL SHAFTS
664 SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS
666 TABLE 1104.9 REVOLVING DOOR SPEEDS
670 TABLE 1104.17.2 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
671 SECTION 1105 REQUIREMENTS FOR OUTDOOR OPERATIONS
672 BIBLIOGRAPHY
674 CHAPTER 12 through CHAPTER 19 RESERVED
676 PART IV—SPECIAL OCCUPANCIES AND OPERATIONS
CHAPTER 20: AVIATION FACILITIES
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
677 SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 AIRCRAFT MAINTENANCE
678 SECTION 2005 PORTABLE FIRE EXTINGUISHERS
680 SECTION 2006 AIRCRAFT FUELING
681 FIGURE 2006.2 AIRCRAFT-FUELING VEHICLE
FIGURE 2006.3 AIRCRAFT-FUELING VEHICLE
691 SECTION 2007 HELISTOPS AND HELIPORTS
FIGURE 2007.1 HELICOPTER LANDING AREA AT GRADE
692 BIBLIOGRAPHY
694 CHAPTER 21: DRY CLEANING
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
695 SECTION 2103 CLASSIFICATIONS
696 FIGURE 2103.2.1 CHARACTERISTICS OF DRY CLEANING SOLVENTS
SECTION 2104 GENERAL REQUIREMENTS
697 SECTION 2105 OPERATING REQUIREMENTS
699 EQUATION 21-1
700 SECTION 2106 SPOTTING AND PRETREATING
701 SECTION 2107 DRY CLEANING SYSTEMS
703 SECTION 2108 FIRE PROTECTION
704 BIBLIOGRAPHY
706 CHAPTER 22: COMBUSTIBLE DUST-PRODUCING OPERATIONS
707 SECTION 2201 GENERAL
SECTION 2202 DEFINITION
SECTION 2203 PRECAUTIONS
708 SECTION 2204 EXPLOSION PROTECTION
TABLE 2204.1 EXPLOSION PROTECTION STANDARDS
BIBLIOGRAPHY
710 CHAPTER 23: MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2301 GENERAL
711 SECTION 2302 DEFINITIONS
SECTION 2303 LOCATION OF DISPENSING DEVICES
FIGURE 2303.1(1) LOCATION OF DISPENSING DEVICES
712 FIGURE 2303.1(2) LOCATION OF DISPENSING DEVICES
FIGURE 2303.1(3) LOCATION OF DISPENSING DEVICES
FIGURE 2303.1(4) LOCATION OF DISPENSING DEVICES
FIGURE 2303.1(5) LOCATION OF DISPENSING DEVICES
713 FIGURE 2303.2 EMERGENCY DISCONNECT SWITCH
SECTION 2304 DISPENSING OPERATIONS
715 SECTION 2305 OPERATIONAL REQUIREMENTS
718 SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
719 FIGURE 2306.2.3(1) ABOVE-GROUND TANKS LOCATED OUTSIDE ABOVE GRADE
FIGURE 2306.2.3(2) BIODIESEL FUELING KIOSK
720 FIGURE 2306.2.3(3) BIODIESEL FUELER
TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
721 FIGURE 2306.2.3(4) 6,000 GALLONS OR LESS PROTECTED ABOVE-GROUND STORAGE TANKS CLASS I, II OR III LIQUIDS
FIGURE 2306.2.3(5) GREATER THAN 6,000 GALLONS PROTECTED ABOVE-GROUND STORAGE TANKS STORING CLASS I, II OR III LIQUIDS
722 FIGURE 2306.2.3(6) ALL OTHER ABOVE-GROUND STORAGE TANKS STORING CLASS II AND III LIQUIDS ONLY
725 FIGURE 2306.7.3 MOUNTING OF DISPENSERS
726 FIGURE 2306.7.4 DISPENSER EMERGENCY VALVES
727 FIGURE 2306.7.5.1 BREAKAWAY DEVICES
728 FIGURE 2306.7.7.2 LOCATION OF ABOVE-GRADE REMOTE PUMPS
732 FIGURE 2306.8.4 ALCOHOL-BLENDED FUEL DISPENSER SIGN
SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
734 SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
736 TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
737 SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
742 SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES
745 SECTION 2311 REPAIR GARAGES
750 BIBLIOGRAPHY
752 CHAPTER 24: FLAMMABLE FINISHES
SECTION 2401 GENERAL
753 SECTION 2402 DEFINITIONS
SECTION 2403 PROTECTION OF OPERATIONS
754 FIGURE 2403.2.1.1(1) FLAMMABLE VAPOR AREA—ELECTRICAL CLASSIFICATION
755 FIGURE 2403.2.1.1(2) EXTENT OF CLASS I, DIVISIONS I AND 2 LOCATIONS IN ENCLOSED COATING PROCESS
758 FIGURE 2403.3.5.1 SPRAY GUN CLEANING MACHINE
759 SECTION 2404 SPRAY FINISHING
762 FIGURE 2404.3.2.5 EXAMPLE OF SPRAY-BOOTH CLEAR SPACE
763 FIGURE 2404.4.1 MAXIMUM TRAVEL TO EXTINGUISHERS
767 FIGURE 2404.7.5(1) INDEPENDENT DUCTS FOR SPRAY BOOTHS
768 FIGURE 2404.7.5(2) COMMON DUCTING SPRAY BOOTHS
769 FIGURE 2404.7.6(1) SEPARATION REQUIREMENTS FOR ROOF EXHAUST DUCT TERMINATIONS
FIGURE 2404.7.6(2) SEPARATION REQUIREMENTS
772 SECTION 2405 DIPPING OPERATIONS
776 FIGURE 2405.9.1 SEPARATION REQUIREMENTS FOR QUENCHING TANKS
FIGURE 2405.9.3 TYPICAL QUENCH TANK ALARM LOCATION
777 FIGURE 2405.10 TYPICAL FLOW-COAT SETUP
SECTION 2406 POWDER COATING
778 FIGURE 2405.11 TYPICAL ROLL-COATING SETUP
780 SECTION 2407 ELECTROSTATIC APPARATUS
782 SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
783 SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS
784 SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS
785 BIBLIOGRAPHY
786 CHAPTER 25: FRUIT AND CROP RIPENING
SECTION 2501 GENERAL
FIGURE 2501.1 FLAMMABILITY CHARACTERISTICS AND ETHYLENE HAZARDS
787 SECTION 2502 DEFINITIONS
SECTION 2503 ETHYLENE GAS
SECTION 2504 SOURCES OF IGNITION
788 SECTION 2505 COMBUSTIBLE WASTE
SECTION 2506 ETHYLENE GENERATORS
789 SECTION 2507 WARNING SIGNS
BIBLIOGRAPHY
790 CHAPTER 26: FUMIGATION AND INSECTICIDAL FOGGING
791 FIGURE 26-1 HAZARDOUS PROPERTIES OF COMMON FUMIGANTS
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
792 SECTION 2603 FIRE SAFETY REQUIREMENTS
793 FIGURE 2603.3.1 FUMIGATION WARNING SIGN
795 BIBLIOGRAPHY
796 CHAPTER 27: SEMICONDUCTOR FABRICATION FACILITIES
SECTION 2701 GENERAL
797 SECTION 2702 DEFINITIONS
FIGURE 2702.1(1) TYPICAL COMPONENTS OF AN HPM FACILITY
798 FIGURE 2702.1(2) HAZARDOUS PRODUCTION MATERIALS (HPM) USED IN THE MANUFACTURE OF SEMICONDUCTORS
799 SECTION 2703 GENERAL SAFETY PROVISIONS
800 FIGURE 2703.3.1 CLEAN ROOM CLASSIFICATIONS
804 FIGURE 2703.10.4.1 CROSS-SECTIONAL DIAMETERS OF VARIOUS-SHAPED DUCTS
810 FIGURE 2703.16 COMMON DOPANT GASES AND THEIR HAZARD CLASSIFICATION
SECTION 2704 STORAGE
811 SECTION 2705 USE AND HANDLING
812 TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
813 TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
814 TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
817 BIBLIOGRAPHY
818 CHAPTER 28: LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 2801 GENERAL
819 SECTION 2802 DEFINITIONS
SECTION 2803 GENERAL REQUIREMENTS
820 SECTION 2804 FIRE PROTECTION
821 SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 2806 LOG STORAGE AREAS
SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
822 SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES
823 SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS
824 FIGURE 2809.3 LUMBER YARD FIRE APPARATUS ACCESS ROADS
825 BIBLIOGRAPHY
826 CHAPTER 29: MANUFACTURE OF ORGANIC COATINGS
828 SECTION 2901 GENERAL
SECTION 2902 DEFINITION
SECTION 2903 GENERAL PRECAUTIONS
829 SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION
830 FIGURE 2904.3 FLAMMABLE LIQUID BONDING AND GROUNDING
831 SECTION 2905 PROCESS STRUCTURES
SECTION 2906 PROCESS MILLS AND KETTLES
832 SECTION 2907 PROCESS PIPING
833 SECTION 2908 RAW MATERIALS IN PROCESS AREAS
SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS
835 BIBLIOGRAPHY
836 CHAPTER 30: INDUSTRIAL OVENS
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
837 SECTION 3003 LOCATION
SECTION 3004 FUEL PIPING
SECTION 3005 INTERLOCKS
SECTION 3006 FIRE PROTECTION
838 SECTION 3007 OPERATION AND MAINTENANCE
BIBLIOGRAPHY
840 CHAPTER 31: TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 3101 GENERAL
841 SECTION 3102 DEFINITIONS
SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
844 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
846 SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
852 BIBLIOGRAPHY
854 CHAPTER 32: HIGH-PILED COMBUSTIBLE STORAGE
SECTION 3201 GENERAL
856 SECTION 3202 DEFINITIONS
SECTION 3203 COMMODITY CLASSIFICATION
FIGURE 3203.1 CLASSIFICATION LEVELS
859 SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS
860 FIGURE 3203.7.4 MIXED COMMODITIESa, b
SECTION 3205 HOUSEKEEPING AND MAINTENANCE
861 FIGURE 3204.2 HIGHER HAZARD STORAGE ALLOWANCE
862 FIGURE 3205.8 SPRINKLER PENETRATION
SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
864 TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
865 FIGURE 3206.2(1) EXTENT OF PROTECTION
FIGURE 3206.2(2) EXTENT OF PROTECTION INCLUDING AISLES
868 FIGURE 3206.6.1.1 REQUIRED ACCESS DOORS
870 FIGURE 3206.9(1) RACK STORAGE (DOUBLE ROW)
871 FIGURE 3206.9(2) HIGH-PILED STORAGE AREA
FIGURE 3206.9(3) HIGH-PILED STORAGE AREA (ALONG WALLS)
872 FIGURE 3206.9.1 CROSS AISLES
SECTION 3207 SOLID-PILED AND SHELF STORAGE
FIGURE 3207.1(1) PALLETIZED STORAGE ARRAY (COMMODITY CONFIGURED WITH FLUE SPACES)
FIGURE 3207.1(2) ENCAPSULATED COMMODITY
873 FIGURE 3207.1(3) ENCAPSULATED COMMODITY
874 SECTION 3208 RACK STORAGE
FIGURE 3208.1 TYPICAL RACK SYSTEM
876 FIGURE 3208.2.2 DOUBLE-ROW RACKS WITH SOLID SHELVES
877 TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE
FIGURE 3208.3.1 FLUE SPACE PROTECTION EXAMPLE
878 FIGURE 3208.3(1) FLUE SPACES (OPTION 1 OF TABLE 3208.3)
FIGURE 3208.3(2) FLUE SPACES (OPTION 2 OF TABLE 3208.3)
879 FIGURE 3208.3(3) FLUE SPACES GREATER THAN 25 FEET (SEE TABLE 3208.3)
FIGURE 3208.3(4) VERTICAL ALIGNMENT OF FLUE SPACES
880 SECTION 3209 AUTOMATED STORAGE
881 SECTION 3210 SPECIALTY STORAGE
BIBLIOGRAPHY
882 CHAPTER 33: FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 DEFINITIONS
883 SECTION 3303 TEMPORARY HEATING EQUIPMENT
SECTION 3304 PRECAUTIONS AGAINST FIRE
FIGURE 3304.1 NO SMOKING SIGN
884 SECTION 3305 FLAMMABLE AND COMBUSTIBLE LIQUIDS
885 SECTION 3306 FLAMMABLE GASES
SECTION 3307 EXPLOSIVE MATERIALS
886 SECTION 3308 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 3309 FIRE REPORTING
887 SECTION 3310 ACCESS FOR FIRE FIGHTING
SECTION 3311 MEANS OF EGRESS
SECTION 3312 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3313 STANDPIPES
888 SECTION 3314 AUTOMATIC SPRINKLER SYSTEM
SECTION 3315 PORTABLE FIRE EXTINGUISHERS
889 SECTION 3316 MOTORIZED CONSTRUCTION EQUIPMENT
SECTION 3317 SAFEGUARDING ROOFING OPERATIONS
BIBLIOGRAPHY
890 CHAPTER 34: TIRE REBUILDING AND TIRE STORAGE
891 SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 TIRE REBUILDING
SECTION 3404 PRECAUTIONS AGAINST FIRE
892 SECTION 3405 OUTDOOR STORAGE
893 SECTION 3406 FIRE DEPARTMENT ACCESS
SECTION 3407 FENCING
894 SECTION 3408 FIRE PROTECTION
SECTION 3409 INDOOR STORAGE ARRANGEMENT
BIBLIOGRAPHY
896 CHAPTER 35: WELDING AND OTHER HOT WORK
SECTION 3501 GENERAL
897 SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
898 SECTION 3504 FIRE SAFETY REQUIREMENTS
901 SECTION 3505 GAS WELDING AND CUTTING
902 FIGURE 3505.2.1 TYPICAL WELDING CHART
904 SECTION 3506 ELECTRIC ARC HOT WORK
SECTION 3507 CALCIUM CARBIDE SYSTEMS
905 SECTION 3508 ACETYLENE GENERATORS
SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
906 BIBLIOGRAPHY
908 CHAPTER 36: MARINAS
SECTION 3601 SCOPE
SECTION 3602 DEFINITIONS
909 SECTION 3603 GENERAL PRECAUTIONS
910 SECTION 3604 FIRE PROTECTION EQUIPMENT
911 SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES
BIBLIOGRAPHY
912 CHAPTERS 37 through 49 RESERVED
914 PART V—HAZARDOUS MATERIALS
CHAPTER 50: HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 5001 GENERAL
923 SECTION 5002 DEFINITIONS
924 SECTION 5003 GENERAL REQUIREMENTS
929 TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
930 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
931 TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
932 TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
933 TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA
934 TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA
940 FIGURE 5003.5 HAZARD IDENTIFICATION SYMBOLS
941 FIGURE 5003.5.1 HAZARD SYMBOLS
942 TABLE 5003.8.2 DETACHED BUILDING REQUIRED
943 FIGURE 5003.8.3(1) CONTROL AREAS
FIGURE 5003.8.3(2) CONTROL AREA EXAMPLE
944 TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
951 TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
953 SECTION 5004 STORAGE
955 TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
960 SECTION 5005 USE, DISPENSING AND HANDLING
963 TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
966 BIBLIOGRAPHY
968 CHAPTER 51: AEROSOLS
SECTION 5101 GENERAL
969 SECTION 5102 DEFINITIONS
SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS
970 SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS
971 TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
972 TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
975 TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 5105 OUTSIDE STORAGE
TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION 5106 RETAIL DISPLAY
976 TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
977 FIGURE 5106.3.2 GUIDE TO CONTENTS OF NFPA 30B TABLES 6.3.2.7(a) through (l)
979 TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
980 SECTION 5107 MANUFACTURING FACILITIES
BIBLIOGRAPHY
982 CHAPTER 52: COMBUSTIBLE FIBERS
SECTION 5201 GENERAL
SECTION 5202 DEFINITIONS
SECTION 5203 GENERAL PRECAUTIONS
983 SECTION 5204 LOOSE FIBER STORAGE
984 SECTION 5205 BALED STORAGE
BIBLIOGRAPHY
986 CHAPTER 53: COMPRESSED GASES
987 SECTION 5301 GENERAL
SECTION 5302 DEFINITIONS
988 SECTION 5303 GENERAL REQUIREMENTS
989 FIGURE 5303.4.1 STORAGE AND LABELING OF CYLINDERS
996 SECTION 5304 STORAGE OF COMPRESSED GASES
SECTION 5305 USE AND HANDLING OF COMPRESSED GASES
998 SECTION 5306 MEDICAL GAS SYSTEMS
999 SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED
BIBLIOGRAPHY
1000 CHAPTER 54: CORROSIVE MATERIALS
SECTION 5401 GENERAL
1001 SECTION 5402 DEFINITIONS
SECTION 5403 GENERAL REQUIREMENTS
SECTION 5404 STORAGE
SECTION 5405 USE
1002 BIBLIOGRAPHY
1004 CHAPTER 55: CRYOGENIC FLUIDS
SECTION 5501 GENERAL
1005 SECTION 5502 DEFINITIONS
SECTION 5503 GENERAL REQUIREMENTS
1010 SECTION 5504 STORAGE
1011 TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
1012 TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
1013 SECTION 5505 USE AND HANDLING
1015 BIBLIOGRAPHY
1016 CHAPTER 56: EXPLOSIVES AND FIREWORKS
1017 SECTION 5601 GENERAL
1022 TABLE 5601.8.1(1) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES
TABLE 5601.8.1(2) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES
TABLE 5601.8.1(3) APPLICATION OF SEPARATION DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVES
1023 SECTION 5602 DEFINITIONS
1024 SECTION 5603 RECORD KEEPING AND REPORTING
1025 SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING
TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
1029 TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
1030 TABLE 5604.5.2(1)—continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a
1031 TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARDa, b, c
TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4c
1032 FIGURE 5604.6.5.2 AN EXAMPLE OF AN EXPLOSIVES PLACARD
1035 SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS
1037 TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa
1041 SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS
1044 SECTION 5607 BLASTING
1046 FIGURE 5607.15 RECOMMENDED WAITING PERIODS FOR INVESTIGATING MISFIRES
SECTION 5608 FIREWORKS DISPLAY
1049 SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS
BIBLIOGRAPHY
1050 CHAPTER 57: FLAMMABLE AND COMBUSTIBLE LIQUIDS
1051 SECTION 5701 GENERAL
1053 SECTION 5702 DEFINITIONS
SECTION 5703 GENERAL REQUIREMENTS
1054 TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
1055 TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
1057 TABLE 5703.6.2 PIPING STANDARDS
1060 SECTION 5704 STORAGE
1084 TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
1090 TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
1091 TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
1092 TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS
1093 TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
1094 TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS OR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
1095 TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa
1097 TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS
1099 TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
1101 SECTION 5705 DISPENSING, USE, MIXING AND HANDLING
1104 TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
1105 TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1)
1107 FIGURE 5705.3.6.2(1) PARTS CLEANING MACHINE WITH SOLVENT RESERVOIR
1108 FIGURE 5705.3.6.2(2) PARTS CLEANING MACHINE WITHOUT SOLVENT RESERVOIR
1111 TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS
1114 FIGURE 5705.5 TOUCH-FREE ALCOHOL-BASED HAND RUB DISPENSER
1115 SECTION 5706 SPECIAL OPERATIONS
1132 FIGURE 5706.6.1.11 TANK VEHICLE POSITIONING DURING UNLOADING
1135 BIBLIOGRAPHY
1136 CHAPTER 58: FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 5801 GENERAL
1137 SECTION 5802 DEFINITIONS
SECTION 5803 GENERAL REQUIREMENTS
1139 SECTION 5804 STORAGE
1140 SECTION 5805 USE
SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS
1143 SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS
1146 BIBLIOGRAPHY
1148 CHAPTER 59: FLAMMABLE SOLIDS
SECTION 5901 GENERAL
1149 SECTION 5902 DEFINITIONS
SECTION 5903 GENERAL REQUIREMENTS
SECTION 5904 STORAGE
1150 SECTION 5905 USE
SECTION 5906 MAGNESIUM
1153 FIGURE 5906.5.3 A SCHEMATIC DIAGRAM OF WATER PRECIPITATION-TYPE COLLECTOR
1155 BIBLIOGRAPHY
1156 CHAPTER 60: HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 6001 GENERAL
1157 SECTION 6002 DEFINITIONS
SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
1159 SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
1165 TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
1168 FIGURE 6004.3.2.1.1(1) FIRE BARRIER
1169 FIGURE 6004.3.2.1.1(2) FIRE BARRIER LIMITATIONS
1170 FIGURE 6004.3.2.1.2OPENINGS
1171 SECTION 6005 OZONE GAS GENERATORS
1172 FIGURE 6005.1 FEDERAL AGENCY OZONE STANDARDS
1174 BIBLIOGRAPHY
1176 CHAPTER 61: LIQUEFIED PETROLEUM GASES
SECTION 6101 GENERAL
1177 FIGURE 6101.1(1) PROPERTIES OF COMMON LP-GASES
FIGURE 6101.1(2) VAPOR PRESSURES OF PROPANE
1178 SECTION 6102 DEFINITIONS
SECTION 6103 INSTALLATION OF EQUIPMENT
1179 FIGURE 6103.2.1 TYPICAL DOT CYLINDERS
1180 SECTION 6104 LOCATION OF LP-GAS CONTAINERS
1181 FIGURE 6104.3(1) LOCATION OF LPG CYLINDER/CONTAINER PER TABLE 6104.3
1182 TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS
1183 FIGURE 6104.3(2) LOCATION OF DOT AND ASME CONTAINERS
FIGURE 6104.3.1 TORCH-APPLIED ROOFING APPARATUS
1184 SECTION 6105 PROHIBITED USE OF LP-GAS
SECTION 6106 DISPENSING AND OVERFILLING
1185 FIGURE 6106.2 CYLINDER VALVE WITH OVERFILL PREVENTION DEVICE
SECTION 6107 SAFETY PRECAUTIONS AND DEVICES
SECTION 6108 FIRE PROTECTION
1186 SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
1188 TABLE 6109.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS
1189 FIGURE 6109.13 INSTALLATION OF LP-GAS CONTAINERS FOR RETAIL SALE OR EXCHANGE
1190 SECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE
1191 SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES
BIBLIOGRAPHY
1192 CHAPTER 62: ORGANIC PEROXIDES
SECTION 6201 GENERAL
SECTION 6202 DEFINITIONS
1193 SECTION 6203 GENERAL REQUIREMENTS
1194 SECTION 6204 STORAGE
1195 FIGURE 6204.1.1 TYPICAL DETACHED STORAGE STRUCTURE
TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
1196 TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES
1198 SECTION 6205 USE
BIBLIOGRAPHY
1200 CHAPTER 63: OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
1201 SECTION 6301 GENERAL
SECTION 6302 DEFINITIONS
SECTION 6303 GENERAL REQUIREMENTS
1204 SECTION 6304 STORAGE
TABLE 6304.1.2 OXIDIZER LIQUIDS AND SOLIDS-DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
1205 TABLE 6304.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERSa
1206 TABLE 6304.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS
TABLE 6304.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS
1207 TABLE 6304.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
1208 TABLE 6304.2.2 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6305 USE
SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE
1211 BIBLIOGRAPHY
1212 CHAPTER 64: PYROPHORIC MATERIALS
1213 SECTION 6401 GENERAL
SECTION 6402 DEFINITIONS
1214 SECTION 6403 GENERAL REQUIREMENTS
SECTION 6404 STORAGE
1216 TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 6405 USE
1217 BIBLIOGRAPHY
1218 CHAPTER 65: PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 6501 GENERAL
1219 SECTION 6502 DEFINITIONS
SECTION 6503 GENERAL REQUIREMENTS
SECTION 6504 STORAGE AND HANDLING
1221 BIBLIOGRAPHY
1222 CHAPTER 66: UNSTABLE (REACTIVE) MATERIALS
SECTION 6601 GENERAL
1223 SECTION 6602 DEFINITIONS
SECTION 6603 GENERAL REQUIREMENTS
1224 SECTION 6604 STORAGE
1226 SECTION 6605 USE
BIBLIOGRAPHY
1228 CHAPTER 67: WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 6701 GENERAL
1229 SECTION 6702 DEFINITIONS
SECTION 6703 GENERAL REQUIREMENTS
SECTION 6704 STORAGE
1232 SECTION 6705 USE
BIBLIOGRAPHY
1234 CHAPTER 68 through CHAPTER 79 RESERVED
1236 PART VI—REFERENCED STANDARDS
CHAPTER 80: REFERENCED STANDARDS
1237 FIGURE 80 REFERENCED STANDARDS
1238 AASHTO
AFSI
API
ASME
1239 ASTM
1240 BHMA
CA
CGA
CGR
1241 CPSC
DOC
DOL
DOTn
1242 DOTy
EN
EPA
FCC
ICC
1243 ISO
NEMA
NFPA
1246 UL
1247 USC
1248 PART VII—APPENDICES
APPENDIX A: BOARD OF APPEALS
SECTION A101 GENERAL
1252 APPENDIX B: FIRE-FLOW REQUIREMENTS FOR BUILDINGS
1253 SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
1254 SECTION B104 FIRE-FLOW CALCULATION AREA
FIGURE B104.1 FIRE-FLOW CALCULATION AREA = A WAREHOUSE + A LOADING DOCK
1255 SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
1257 TABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS
1258 SECTION B106 REFERENCED STANDARDS
BIBLIOGRAPHY
1260 APPENDIX C: FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 LOCATION
SECTION C103 NUMBER OF FIRE HYDRANTS
1261 FIGURE C103.1 HYDRANT SPACING
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
1262 SECTION C105 DISTRIBUTION OF FIRE HYDRANTS
TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
1263 FIGURE C105.1(1) AVERAGE HYDRANT SPACING
1264 FIGURE C105.1(2) TRAVEL DISTANCE TO HYDRANTS
FIGURE C105.1(3) TRAVEL DISTANCE TO HYDRANTS
1265 FIGURE C105.1(4) HYDRANT SPACING ALONG BOULEVARDS AND HIGH-VOLUME ARTERIAL STREETS
BIBLIOGRAPHY
1266 APPENDIX D: FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
1267 SECTION D103 MINIMUM SPECIFICATIONS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
1268 TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
1269 FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
1270 SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
1271 SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D108 REFERENCED STANDARDS
BIBLIOGRAPHY
1272 APPENDIX E: HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
1279 SECTION E103 EVALUATION OF HAZARDS
1284 E104 REFERENCED STANDARDS
1286 APPENDIX F: HAZARD RANKING
SECTION F101 GENERAL
1287 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
1288 SECTION F102 REFERENCED STANDARDS
1290 APPENDIX G: CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
1291 BIBLIOGRAPHY
1292 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
1294 APPENDIX H: HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS
SECTION H101 HMMP
1295 SECTION H102 HMIS
1296 SECTION H103 EMERGENCY PLAN
SECTION H104 REFERENCED STANDARDS
1297 FIGURE 1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
1298 FIGURE 2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION
1299 FIGURE 3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP
1300 FIGURE 4 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS SUMMARY REPORTa (Storageb Conditions)c
1301 FIGURE 5 SECTION II — HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) HMIS INVENTORY REPORT (Sort Products Alphabetically by Location of Product and then Alphabetically by Product Name)
1302 APPENDIX I: FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
1304 SECTION I102 REFERENCED STANDARDS
1306 APPENDIX J: BUILDING INFORMATION SIGN
SECTION J101 GENERAL
1307 FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN
1309 SECTION J102 REFERENCED STANDARDS
1310 INDEX
ICC IFC Commentary 2012
$81.25