ICC IFGC 2024 1stptg
$63.38
International Fuel Gas Code
Published By | Publication Date | Number of Pages |
ICC | 2024 | 215 |
The 2024 International Codes® (I-Codes®) have undergone substantial formatting changes as part of the digital transformation strategy of the International Code Council® (ICC®) to improve the user experience. The changes, promoting a cleaner, more modern look and enhancing readability and sustainability, include: Single column text format and modernized font styles improves readability QR Codes replace vertical margin sidebars and arrows to identify code changes more accurately Shading for table headers and notes improves locating tables and applicable notes Grouping of associated content brings tables and figures immediately after the parent section Users have capability to validate authenticity of their book and register it with the ICC to receive incentives. The 2024 IFGC® addresses the design and installation of fuel gas systems and gas fired appliances through prescriptive and performance requirements. Key changes in the 2024 IFGC® include: Appendix D- D105.2, Test for combustion air and vent drafting for natural draft and Category I appliances. Existing code language has been deleted. The entire section is new for the 2024 Codes. [BS] 302.3.1 Engineered wood products. Sections 302.3.2, 302.3.3, and 302.3.4 have all been deleted. 304.1 -General. The entire section is new for the 2024 Codes. Existing code language has been deleted. The entire section is new for the 2024 Codes. 304.12 Protection from fumes and gases. Existing code language has been deleted. The entire section is new for the 2024 Codes. 403.6 Workmanship and defects. Existing code language has been rewritten and additional code language has been added for the 2024 Codes. Table 503.8- Note: Revisions to Table 503.8 are errata to the 2021 IFGS text that is also applicable to the 2024 IFGS text.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2024 INTERNATIONAL FUEL GAS CODE® |
2 | 2024 INTERNATIONAL FUEL GAS CODE® |
3 | COPYRIGHT |
4 | NEW DESIGN FOR THE 2024 INTERNATIONAL CODES |
5 | PREFACE |
12 | CONTENTS |
14 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 (IFGC)—SCOPE AND GENERAL REQUIREMENTS |
15 | SECTION 102 (IFGC)—APPLICABILITY |
16 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 (IFGC)—CODE COMPLIANCE AGENCY SECTION 104 (IFGC)—DUTIES AND POWERS OF THE CODE OFFICIAL |
18 | SECTION 105 (IFGC)—PERMITS |
19 | SECTION 106 (IFGC)—CONSTRUCTION DOCUMENTS |
20 | SECTION 107 (IFGC)—NOTICE OF APPROVAL SECTION 108 (IFGC)—FEES SECTION 109 (IFGC)—SERVICE UTILITIES |
21 | SECTION 110 (IFGC)—TEMPORARY USES, EQUIPMENT AND SYSTEMS SECTION 111 (IFGC)—INSPECTIONS AND TESTING |
22 | SECTION 112 (IFGC)—MEANS OF APPEALS SECTION 113 (IFGC)—VIOLATIONS |
23 | SECTION 114 (IFGC)—STOP WORK ORDER |
24 | CHAPTER 2 DEFINITIONS SECTION 201 (IFGC)—GENERAL SECTION 202 (IFGC)—GENERAL DEFINITIONS |
33 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 (IFGC)—GENERAL |
34 | SECTION 302 (IFGC)—STRUCTURAL SAFETY SECTION 303 (IFGC)—APPLIANCE LOCATION |
35 | SECTION 304 (IFGS)—COMBUSTION, VENTILATION AND DILUTION AIR EQUATION 3-1 EQUATION 3-2 |
36 | FIGURE 304.5.3—ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3) |
37 | FIGURE 304.6.1(1)—ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1) FIGURE 304.6.1(2)—ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1) |
38 | FIGURE 304.6.1(3)—ALL AIR FROM OUTDOORS (see Section 304.6.1) FIGURE 304.6.2—SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2) |
39 | SECTION 305 (IFGC)—INSTALLATION |
40 | SECTION 306 (IFGC)—ACCESS AND SERVICE SPACE |
42 | SECTION 307 (IFGC)—CONDENSATE DISPOSAL SECTION 308 (IFGS)—CLEARANCE REDUCTION |
43 | TABLE 308.2—REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa through k |
44 | FIGURE 308.2(1)—EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS FIGURE 308.2(2)—WALL PROTECTOR CLEARANCE REDUCTION SYSTEM FIGURE 308.2(3)—MASONRY CLEARANCE REDUCTION SYSTEM |
45 | SECTION 309 (IFGC)—ELECTRICAL SECTION 310 (IFGS)—ELECTRICAL BONDING |
46 | CHAPTER 4 GAS PIPING INSTALLATIONS SECTION 401 (IFGC)—GENERAL SECTION 402 (IFGS)—PIPE SIZING |
47 | EQUATION 4-1 EQUATION 4-2 TABLE 402.4—Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS |
48 | TABLE 402.4(1)—SCHEDULE 40 METALLIC PIPE |
49 | TABLE 402.4(1)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(2)—SCHEDULE 40 METALLIC PIPE |
50 | TABLE 402.4(2)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(3)—SCHEDULE 40 METALLIC PIPE |
51 | TABLE 402.4(3)—SCHEDULE 40 METALLIC PIPE—continued |
52 | TABLE 402.4(4)—SCHEDULE 40 METALLIC PIPE |
53 | TABLE 402.4(4)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(5)—SCHEDULE 40 METALLIC PIPE |
54 | TABLE 402.4(5)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(6)—SCHEDULE 40 METALLIC PIPE |
55 | TABLE 402.4(6)—SCHEDULE 40 METALLIC PIPE—continued |
56 | TABLE 402.4(7)—SCHEDULE 40 METALLIC PIPE |
57 | TABLE 402.4(7)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(8)—SEMIRIGID COPPER TUBING |
58 | TABLE 402.4(8)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(9)—SEMIRIGID COPPER TUBING |
59 | TABLE 402.4(9)—SEMIRIGID COPPER TUBING—continued |
60 | TABLE 402.4(9)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(10)—SEMIRIGID COPPER TUBING |
61 | TABLE 402.4(10)—SEMIRIGID COPPER TUBING—continued |
62 | TABLE 402.4(11)—SEMIRIGID COPPER TUBING |
63 | TABLE 402.4(11)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(12)—SEMIRIGID COPPER TUBING |
64 | TABLE 402.4(12)—SEMIRIGID COPPER TUBING—continued |
65 | TABLE 402.4(13)—SEMIRIGID COPPER TUBING |
66 | TABLE 402.4(13)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(14)—SEMIRIGID COPPER TUBING |
67 | TABLE 402.4(14)—SEMIRIGID COPPER TUBING—continued |
68 | TABLE 402.4(15)—CORRUGATED STAINLESS STEEL TUBING (CSST) TABLE 402.4(16)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
69 | TABLE 402.4(16)—CORRUGATED STAINLESS STEEL TUBING (CSST)—continued TABLE 402.4(17)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
70 | TABLE 402.4(17)—CORRUGATED STAINLESS STEEL TUBING (CSST)—continued TABLE 402.4(18)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
71 | TABLE 402.4(18)—CORRUGATED STAINLESS STEEL TUBING (CSST)—continued TABLE 402.4(19)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
72 | TABLE 402.4(20)—POLYETHYLENE PLASTIC PIPE TABLE 402.4(21)—POLYETHYLENE PLASTIC PIPE |
73 | TABLE 402.4(21)—POLYETHYLENE PLASTIC PIPE—continued TABLE 402.4(22)—POLYETHYLENE PLASTIC PIPE |
74 | TABLE 402.4(22)—POLYETHYLENE PLASTIC PIPE—continued |
75 | TABLE 402.4(23)—POLYETHYLENE PLASTIC PIPE |
76 | TABLE 402.4(24)—POLYETHYLENE PLASTIC PIPE |
77 | TABLE 402.4(25)—SCHEDULE 40 METALLIC PIPE |
78 | TABLE 402.4(25)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(26)—SCHEDULE 40 METALLIC PIPE |
79 | TABLE 402.4(26)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(27)—SCHEDULE 40 METALLIC PIPE |
80 | TABLE 402.4(27)—SCHEDULE 40 METALLIC PIPE—continued |
81 | TABLE 402.4(27)—SCHEDULE 40 METALLIC PIPE—continued TABLE 402.4(28)—SCHEDULE 40 METALLIC PIPE |
82 | TABLE 402.4(28)—SCHEDULE 40 METALLIC PIPE—continued |
83 | TABLE 402.4(29)—SEMIRIGID COPPER TUBING |
84 | TABLE 402.4(29)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(30)—SEMIRIGID COPPER TUBING |
85 | TABLE 402.4(30)—SEMIRIGID COPPER TUBING—continued |
86 | TABLE 402.4(31)—SEMIRIGID COPPER TUBING |
87 | TABLE 402.4(31)—SEMIRIGID COPPER TUBING—continued TABLE 402.4(32)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
88 | TABLE 402.4(32)—CORRUGATED STAINLESS STEEL TUBING (CSST)—continued TABLE 402.4(33)—CORRUGATED STAINLESS STEEL TUBING (CSST) |
89 | TABLE 402.4(34)—CORRUGATED STAINLESS STEEL TUBING (CSST) TABLE 402.4(35)—POLYETHYLENE PLASTIC PIPE |
90 | TABLE 402.4(35)—POLYETHYLENE PLASTIC PIPE—continued TABLE 402.4(36)—POLYETHYLENE PLASTIC PIPE |
91 | TABLE 402.4(36)—POLYETHYLENE PLASTIC PIPE—continued |
92 | TABLE 402.4(36)—POLYETHYLENE PLASTIC PIPE—continued TABLE 402.4(37)—POLYETHYLENE PLASTIC PIPE |
93 | TABLE 402.4(37)—POLYETHYLENE PLASTIC PIPE—continued |
94 | SECTION 403 (IFGS)—PIPING MATERIALS |
95 | TABLE 403.8.2—SPECIFICATIONS FOR THREADING METALLIC PIPE |
97 | SECTION 404 (IFGC)—PIPING SYSTEM INSTALLATION |
99 | SECTION 405 (IFGS)—PIPING BENDS AND CHANGES IN DIRECTION SECTION 406 (IFGS)—INSPECTION, TESTING AND PURGING |
100 | TABLE 406.7.1.1—SIZE AND LENGTH OF PIPING |
101 | TABLE 406.7.1.1—SIZE AND LENGTH OF PIPING—continued |
102 | SECTION 407 (IFGC)—PIPING SUPPORT SECTION 408 (IFGC)—DRIPS AND SLOPED PIPING FIGURE 408.4—METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP |
103 | SECTION 409 (IFGC)—SHUTOFF VALVES TABLE 409.1.1—MANUAL GAS VALVE STANDARDS |
104 | SECTION 410 (IFGC)—FLOW CONTROLS SECTION 411 (IFGC)—APPLIANCE AND MANUFACTURED HOME CONNECTIONS |
105 | SECTION 412 (IFGC)—LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES |
107 | SECTION 413 (IFGC)—COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES |
108 | [F] TABLE 413.10.2.3—SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG |
109 | SECTION 414 (IFGC)—SUPPLEMENTAL AND STANDBY GAS SUPPLY SECTION 415 (IFGS)—PIPING SUPPORT INTERVALS TABLE 415.1—SUPPORT OF PIPING SECTION 416 (IFGS)—OVERPRESSURE PROTECTION DEVICES |
111 | CHAPTER 5 CHIMNEYS AND VENTS SECTION 501 (IFGC)—GENERAL |
112 | SECTION 502 (IFGC)—VENTS |
113 | SECTION 503 (IFGS)—VENTING OF APPLIANCES |
114 | TABLE 503.4—TYPE OF VENTING SYSTEM TO BE USED |
116 | FIGURE 503.6.5—TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL |
119 | FIGURE 503.8—THROUGH-THE-WALL VENT TERMINAL CLEARANCE TABLE 503.8—THROUGH-THE-WALL VENT TERMINAL CLEARANCE |
120 | TABLE 503.10.2.4—MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES |
121 | TABLE 503.10.2.5—MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES TABLE 503.10.5—CLEARANCES FOR CONNECTORSa |
122 | TABLE 503.10.5—CLEARANCES FOR CONNECTORSa—continued |
123 | SECTION 504 (IFGS)—SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS |
124 | TABLE 504.2(1)—TYPE B DOUBLE-WALL GAS VENT |
125 | TABLE 504.2(1)—TYPE B DOUBLE-WALL GAS VENT—continued |
126 | TABLE 504.2(1)—TYPE B DOUBLE-WALL GAS VENT |
127 | TABLE 504.2(1)—TYPE B DOUBLE-WALL GAS VENT—continued |
128 | TABLE 504.2(2)—TYPE B DOUBLE-WALL GAS VENT |
129 | TABLE 504.2(2)—TYPE B DOUBLE-WALL GAS VENT—continued |
130 | TABLE 504.2(3)—MASONRY CHIMNEY |
131 | TABLE 504.2(3)—MASONRY CHIMNEY—continued |
132 | TABLE 504.2(4)—MASONRY CHIMNEY |
133 | TABLE 504.2(4)—MASONRY CHIMNEY—continued |
134 | TABLE 504.2(5)—SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT |
135 | TABLE 504.2(6)—EXTERIOR MASONRY CHIMNEY |
136 | TABLE 504.2(6)—EXTERIOR MASONRY CHIMNEY—continued |
138 | TABLE 504.3(1)—TYPE B DOUBLE-WALL VENT |
139 | TABLE 504.3(1)—TYPE B DOUBLE-WALL VENT—continued |
140 | TABLE 504.3(1)—TYPE B DOUBLE-WALL VENT—continued |
141 | TABLE 504.3(2)—TYPE B DOUBLE-WALL VENT |
142 | TABLE 504.3(2)—TYPE B DOUBLE-WALL VENT—continued |
143 | TABLE 504.3(3)—MASONRY CHIMNEY |
144 | TABLE 504.3(3)—MASONRY CHIMNEY—continued |
145 | TABLE 504.3(4)—MASONRY CHIMNEY |
146 | TABLE 504.3(4)—MASONRY CHIMNEY—continued |
147 | TABLE 504.3(5)—SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT |
148 | TABLE 504.3(6a)—EXTERIOR MASONRY CHIMNEY TABLE 504.3(6b)—EXTERIOR MASONRY CHIMNEY |
149 | TABLE 504.3(6b)—EXTERIOR MASONRY CHIMNEY—continued TABLE 504.3(7a)—EXTERIOR MASONRY CHIMNEY |
150 | TABLE 504.3(7b)—EXTERIOR MASONRY CHIMNEY |
151 | TABLE 504.3(7b)—EXTERIOR MASONRY CHIMNEY—continued TABLE 504.3.2—MAXIMUM VENT CONNECTOR LENGTH |
152 | TABLE 504.3.2—MAXIMUM VENT CONNECTOR LENGTH—continued |
154 | SECTION 505 (IFGC)—DIRECT-VENT, INTEGRAL VENT,MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING SECTION 506 (IFGC)—FACTORY-BUILT CHIMNEYS |
155 | CHAPTER 6 SPECIFIC APPLIANCES SECTION 601 (IFGC)—GENERAL SECTION 602 (IFGC)—DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES SECTION 603 (IFGC)—LOG LIGHTERS SECTION 604 (IFGC)—VENTED GAS FIREPLACES (DECORATIVE APPLIANCES) SECTION 605 (IFGC)—VENTED GAS FIREPLACE HEATERS SECTION 606 (IFGC)—INCINERATORS AND CREMATORIES SECTION 607 (IFGC)—COMMERCIAL-INDUSTRIAL INCINERATORS SECTION 608 (IFGC)—VENTED WALL FURNACES |
156 | SECTION 609 (IFGC)—FLOOR FURNACES SECTION 610 (IFGC)—DUCT FURNACES SECTION 611 (IFGC)—NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS |
157 | SECTION 612 (IFGC)—RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS SECTION 613 (IFGC)—CLOTHES DRYERS SECTION 614 (IFGC)—CLOTHES DRYER EXHAUST |
158 | TABLE 614.9.4.1 [M] TABLE 614.9.4.1—DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH |
159 | SECTION 615 (IFGC)—SAUNA HEATERS |
160 | SECTION 616 (IFGC)—ENGINE AND GAS TURBINE-POWERED EQUIPMENT SECTION 617 (IFGC)—POOL AND SPA HEATERS SECTION 618 (IFGC)—FORCED-AIR WARM-AIR FURNACES |
161 | SECTION 619 (IFGC)—CONVERSION BURNERS SECTION 620 (IFGC)—UNIT HEATERS SECTION 621 (IFGC)—UNVENTED ROOM HEATERS |
162 | SECTION 622 (IFGC)—VENTED ROOM HEATERS SECTION 623 (IFGC)—COOKING APPLIANCES SECTION 624 (IFGC)—WATER HEATERS SECTION 625 (IFGC)—REFRIGERATORS SECTION 626 (IFGC)—GAS-FIRED TOILETS |
163 | SECTION 627 (IFGC)—AIR-CONDITIONING APPLIANCES SECTION 628 (IFGC)—ILLUMINATING APPLIANCES |
164 | SECTION 629 (IFGC)—SMALL CERAMIC KILNS SECTION 630 (IFGC)—INFRARED RADIANT HEATERS SECTION 631 (IFGC)—BOILERS SECTION 632 (IFGC)—EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS SECTION 633 (IFGC)—STATIONARY FUEL-CELL POWER SYSTEMS SECTION 634 (IFGC)—GASEOUS HYDROGEN SYSTEMS SECTION 635 (IFGC)—OUTDOOR DECORATIVE APPLIANCES |
165 | CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 (IFGC)—GENERAL SECTION 702 (IFGC)—GENERAL DEFINITIONS SECTION 703 (IFGC)—GENERAL REQUIREMENTS |
166 | SECTION 704 (IFGC)—PIPING, USE AND HANDLING |
167 | SECTION 705 (IFGC)—TESTING OF HYDROGEN PIPING SYSTEMS |
168 | SECTION 706 (IFGC)—LOCATION OF GASEOUS HYDROGEN SYSTEMS SECTION 707 (IFGC)—OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS SECTION 708 (IFGC)—DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS |
169 | CHAPTER 8 REFERENCED STANDARDS (IFGC/IFGS) AISI ANSI |
171 | ASME ASSP ASTM |
172 | CGA CSA DOTn |
173 | ICC MSS NFPA SMACNA |
174 | UL |
175 | APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (IFGS) SECTION A101—GENERAL PIPING CONSIDERATIONS SECTION A102—DESCRIPTION OF TABLES |
176 | TABLE A102.2—EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES |
177 | TABLE A102.2—EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES—continued TABLE A102.4—MULTIPLIERS TO BE USED WITHTABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 |
178 | SECTION A103—USE OF CAPACITY TABLES |
179 | EQUATION A-1 EQUATION A-2 |
180 | TABLE A103.4—THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS SECTION A104—USE OF SIZING EQUATIONS SECTION A105—PIPE AND TUBE DIAMETERS TABLE A105.1—SCHEDULE 40 STEEL PIPE STANDARD SIZES |
181 | TABLE A105.1—SCHEDULE 40 STEEL PIPE STANDARD SIZES—continued TABLE A105.2—COPPER TUBE STANDARD SIZES |
182 | SECTION A106—EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING FIGURE A106.1—PIPING PLAN SHOWING A STEEL PIPING SYSTEM |
183 | FIGURE A106.2—PIPING PLAN SHOWING A CSST SYSTEM |
184 | FIGURE A106.3—PIPING PLAN SHOWING A COPPER TUBING SYSTEM |
185 | FIGURE A106.4—PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM |
187 | APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTEDFOR USE WITH TYPE B VENTS (IFGS) SECTION B101—EXAMPLES USING SINGLE-APPLIANCE VENTING TABLES FIGURE B101.1—EXAMPLE 1—SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE |
188 | FIGURE B101.2—EXAMPLE 2—SINGLE FAN-ASSISTED APPLIANCE |
189 | FIGURE B101.4(1)—TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT FIGURE B101.4(2)—TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR |
190 | FIGURE B101.4(3)—VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR FIGURE B101.4(4)—VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR |
191 | FIGURE B101.4(5)—ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE SECTION B102—EXAMPLES USING COMMON VENTING TABLES |
192 | FIGURE B102.1—EXAMPLE 4—COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES |
193 | FIGURE B102.2—EXAMPLE 5A—COMMON VENTING A DRAFT HOOD WITHA FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT |
194 | TABLE B102.3—MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa |
195 | FIGURE B102.5(1)—VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITHTYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR |
196 | FIGURE B102.5(2)—VENT SYSTEM SERVING TWO OR MORE APPLIANCESWITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS FIGURE B102.5(3)—MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR |
197 | FIGURE B102.5(4)—MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS FIGURE B102.5(5)—ASBESTOS CEMENT TYPE B OR SINGLE-WALL METALVENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES |
198 | FIGURE B102.5(6)—USE OF MANIFOLD COMMON VENT CONNECTOR FIGURE B102.5(7)—USE OF OFFSET COMMON VENT |
199 | FIGURE B102.5(8)—MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM |
200 | FIGURE B102.5(9)—MULTISTORY VENT SYSTEMS |
201 | FIGURE B102.5(10)—NATIONAL FUEL GAS CODE 99-PERCENT WINTER DESIGN TEMPERATURES FOR THE CONTIGUOUS UNITED STATES |
202 | APPENDIX C RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION (IFGS) SECTION C101—GENERAL SECTION C102—OCCUPANT AND INSPECTOR SAFETY |
203 | SECTION C103—GAS PIPING AND CONNECTIONS INSPECTIONS SECTION C104—INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING |
204 | SECTION C105—INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING |
205 | SECTION C106—APPLIANCE-SPECIFIC INSPECTIONS |
207 | TABLE C106—CO THRESHOLDS |
208 | APPENDIX D BOARD OF APPEALS (IFGC) SECTION D101—GENERAL |
210 | INDEX |
212 | ICC EVALUATION SERVICE® |
213 | ICC CREDENTIALING |
214 | ICC CHANGES TO THE CODE DEVELOPMENT PROCESS |
215 | ICC DIGITAL CODES PREMIUM® |