ICC IgCC 2021 1stprint
$112.13
International Green Construction Code® (IgCC®) Powered by ASHRAE Standard 189.1-2020, 2nd Printing
Published By | Publication Date | Number of Pages |
ICC | 2021 | 225 |
A Comprehensive Solution for High-Performance Buildings A whole systems approach to the design, construction and operation of buildings, the IgCC contains measures that result in better indoor environments, lower impact on natural resources, better neighborhood connections, and improved walkability. It includes ANSI/ASHRAE/USGBC/IES 189.1-2020 Standard the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings. The IgCC provisions allow the seamless coordination with either the IECC® or ASHRAE Standard 90.1 for ease of adoption in any jurisdiction.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2021 IgCC® INTERNATIONAL GREEN CONSTRUCTION CODE® |
2 | 2021 IgCC® INTERNATIONAL GREEN CONSTRUCTION CODE® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
10 | ARRANGEMENT AND FORMAT OF THE 2021 IgCC |
18 | TABLE OF CONTENTS |
20 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS |
21 | TABLE 101.5.1 REQUIREMENTS DETERMINED BY THE JURISDICTION TABLE 101.5.1—continued REQUIREMENTS DETERMINED BY THE JURISDICTION |
22 | SECTION 102 APPLICABILITY PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 CODE COMPLIANCE AGENCY SECTION 104 DUTIES AND POWERS OF THE AUTHORITY HAVING JURISDICTION |
23 | SECTION 105 APPROVAL SECTION 106 PERMITS |
24 | SECTION 107 CONSTRUCTION DOCUMENTS SECTION 108 FEES SECTION 109 INSPECTIONS SECTION 110 CERTIFICATE OF OCCUPANCY SECTION 111 MEANS OF APPEALS |
26 | CHAPTER 2 RESERVED |
28 | CHAPTER 3 DEFINITIONS, ABBREVIATIONS AND ACRONYMS 301.1 (3.1) GENERAL 301.2 (3.2) DEFINITIONS |
34 | 301.3 (3.3) ABBREVIATIONS AND ACRONYMS |
38 | CHAPTER 4 RESERVED |
40 | CHAPTER 5 SITE SUSTAINABILITY 501.1 (5.1) SCOPE 501.2 (5.2) COMPLIANCE 501.3 (5.3) MANDATORY PROVISIONS |
44 | TABLE 501.3.6.1 (TABLE 5.3.6.1) MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS |
46 | CHAPTER 6 WATER USE EFFICIENCY 601.1 (6.1) SCOPE 601.2 (6.2) COMPLIANCE 601.3 (6.3) MANDATORY PROVISIONS |
48 | TABLE 601.3.2.1 (TABLE 6.3.2.1) PLUMBING FIXTURES AND FITTINGS REQUIREMENTS |
49 | TABLE 601.3.2.3 (TABLE 6.3.2.3) RECIRCULATING WATER PROPERTIES FOR OPEN-CIRCUIT COOLING-TOWER CONSTRUCTION |
50 | TABLE 601.3.3.1 (TABLE 6.3.3.1) INTERNAL VOLUME OF PIPE OR TUBE IN I-P (SI) |
51 | TABLE 601.3.5.1A (TABLE 6.3.5.1A) WATER SUPPLY SOURCE MEASUREMENT THRESHOLDS |
52 | TABLE 601.3.5.1B (TABLE 6.3.5.1B) SUBSYSTEM WATER MEASUREMENT THRESHOLDS |
54 | CHAPTER 7 ENERGY EFFICIENCY 701.1 (7.1) SCOPE 701.2 (7.2) COMPLIANCE 701.3 (7.3) MANDATORY PROVISIONS |
55 | TABLE 701.3.3.1A (TABLE 7.3.3.1A) ENERGY SOURCE THRESHOLDS TABLE 701.3.3.1B (TABLE 7.3.3.1B) SYSTEM ENERGY USE THRESHOLDS |
56 | 701.4 (7.4) PRESCRIPTIVE OPTION |
57 | TABLE 701.4.1.1 (TABLE 7.4.1.1) RENEWABLE ENERGY REQUIREMENT TABLE 701.4.1.2 (TABLE 7.4.1.2) MULTIPLIERS FOR RENEWABLE ENERGY PROCUREMENT METHODS |
62 | TABLE 701.4.3.4 (TABLE 7.4.3.4) MINIMUM SYSTEM SIZE FOR WHICH AN ECONOMIZER IS REQUIRED |
63 | TABLE 701.4.3.6.3 (TABLE 7.4.3.6.3) MINIMUM VENTILATION FAN EFFICACY REQUIREMENTS TABLE 701.4.3.8.1 (TABLE 7.4.3.8.1) MAXIMUM NET EXHAUST FLOW RATE PER LENGTH OF HOOD |
65 | TABLE 701.4.6.1A (TABLE 7.4.6.1A) LIGHTING POWER DENSITIES USING THE BUILDING AREA METHOD |
66 | TABLE 701.4.6.1B (TABLE 7.4.6.1B) LIGHTING POWER DENSITY (LPD) ALLOWANCES AND ROOM CAVITY RATIO (RCR) THRESHOLDS USING THE SPACE-BY-SPACE METHOD |
67 | TABLE 701.4.6.1B (TABLE 7.4.6.1B)—continued LIGHTING POWER DENSITY (LPD) ALLOWANCES AND ROOM CAVITY RATIO (RCR) THRESHOLDS USING THE SPACE-BY-SPACE METHOD |
68 | TABLE 701.4.6.1B (TABLE 7.4.6.1B)—continued LIGHTING POWER DENSITY (LPD) ALLOWANCES AND ROOM CAVITY RATIO (RCR) THRESHOLDS USING THE SPACE-BY-SPACE METHOD |
69 | TABLE 701.4.6.1B (TABLE 7.4.6.1B)—continued LIGHTING POWER DENSITY (LPD) ALLOWANCES AND ROOM CAVITY RATIO (RCR) THRESHOLDS USING THE SPACE-BY-SPACE METHOD |
70 | TABLE 701.4.6.1B (TABLE 7.4.6.1B)—continued LIGHTING POWER DENSITY (LPD) ALLOWANCES AND ROOM CAVITY RATIO (RCR) THRESHOLDS USING THE SPACE-BY-SPACE METHOD TABLE 701.4.6.1.2 (TABLE 7.4.6.1.2) LIGHTING POWER ALLOWANCE FACTORS |
74 | 701.5 (7.5) PERFORMANCE OPTION |
75 | TABLE 701.5.1 (TABLE 7.5.1) ENERGY COST AND CO2e BUILDING PERFORMANCE FACTORS (BPF) |
76 | TABLE 701.5.2 (TABLE 7.5.2) SOURCE ENERGY CONVERSION FACTORS AND CO2e EMISSIONS FACTORS |
77 | FIGURE 701.5.2 (FIGURE 7.5.2) MAP OF eGRID SUBREGIONS |
78 | CHAPTER 8 INDOOR ENVIRONMENTAL QUALITY (IEQ) 801.1 (8.1) SCOPE 801.2 (8.2) COMPLIANCE 801.3 (8.3) MANDATORY PROVISIONS |
82 | TABLE 801.3.3.2 (TABLE 8.3.3.2) MAXIMUM INTERIOR BACKGROUND SOUND PRESSURE LEVELS FROM BUILDING SYSTEMS AND EXTERIOR SOUND SOURCESa |
83 | TABLE 801.3.3.3 (TABLE 8.3.3.3) MINIMUM SOUND AND IMPACT SOUND RATINGS |
84 | TABLE 801.3.3.4 (TABLE 8.3.3.4) MAXIMUM REVERBERATION TIME TABLE 801.3.3.5.1 (TABLE 8.3.3.5.1) PROPERTY LINE MAXIMUM SOUND LEVELS—PRESCRIPTIVE OPTION TABLE 801.3.3.5.2 (TABLE 8.3.3.5.2) PROPERTY LINE MAXIMUM SOUND LEVELS—TESTED PERFORMANCE OPTION |
85 | TABLE 801.3.4.1.2 (TABLE 8.3.4.1.2) SOIL-GAS CONVEYANCE COMPONENTS |
86 | TABLE 801.3.4.1.3 (TABLE 8.3.4.1.3) VENT PIPE DIAMETER PER VENTED AREA |
87 | TABLE 801.3.5.4.1 (TABLE 8.3.5.4.1) MAXIMUM PERCENT MODULATION FOR LIGHT SOURCES TESTED IN ACCORDANCE WITH CALIFORNIA TITLE 24, PART 6, JA10 |
88 | TABLE 801.3.9 (TABLE 8.3.9) EXTERIOR VIEW SPACES 801.4 (8.4) PRESCRIPTIVE OPTION |
89 | TABLE 801.4.1.2A (TABLE 8.4.1.2A) DAYLIT SPACES TABLE 801.4.1.2B (TABLE 8.4.1.2B) MINIMUM SIDELIGHTING EFFECTIVE APERTURE |
91 | TABLE 801.4.2.3.1 (TABLE 8.4.2.3.1) FLOOR COVERING DEEMED TO COMPLY WITH VOC EMISSION LIMITS |
92 | TABLE 801.4.2.6.1 (TABLE 8.4.2.6.1) CEILING AND WALL PRODUCTS DEEMED TO COMPLY WITH VOC EMISSION LIMITS 801.5 (8.5) PERFORMANCE OPTION |
94 | CHAPTER 9 MATERIALS AND RESOURCES 901.1 (9.1) SCOPE 901.2 (9.2) COMPLIANCE 901.3 (9.3) MADATORY PROVISIONS |
95 | TABLE 901.3.5 (TABLE 9.3.5) MAXIMUM MERCURY CONTENT FOR ELECTRIC LAMPS 901.4 (9.4) PRESCRIPTIVE OPTION |
96 | 901.5 (9.5) PERFORMANCE OPTION |
98 | CHAPTER 10 CONSTRUCTION AND PLANS FOR OPERATION 1001.1 (10.1) SCOPE 1001.2 (10.2) COMPLIANCE 1001.3 (10.3) FUNCTIONAL AND PERFORMANCE TESTING AND COMMISSIONING |
100 | 1001.4 (10.4) CONSTRUCTION OPERATIONS AND START-UP REQUIREMENTS 1001.5 (10.5) ACOUSTICAL FIELD MEASUREMENT |
101 | 1001.6 (10.6) BUILDING ENVELOPE AIRTIGHTNESS 1001.7 (10.7) [JO] POSTCONSTRUCTION BUILDING FLUSH-OUT AND AIR MONITORING EQUATION 10-1 |
102 | TABLE 1001.7.2 (TABLE 10.7.2) MAXIMUM CONCENTRATION OF AIR POLLUTANTS RELEVANT TO IAQ 1001.8 (10.8) SOIL-GAS CONTROL 1001.9 (10.9) PLANS FOR HIGH-PERFORMANCE BUILDING OPERATION |
105 | 1001.10 (10.10) [JO] SERVICE LIFE PLAN |
106 | TABLE 1001.10 (TABLE 10.10) MINIMUM DESIGN SERVICE LIFE FOR BUILDINGS |
108 | CHAPTER 11 NORMATIVE REFERENCES AARST AHAM AHRI AMCA |
109 | ANSI APA ASA ASABE |
110 | ASHE ASHRAE |
111 | ASME ASTM |
112 | BIFMA BSI |
113 | CARB CDPH CEC CEN CGSB CITES |
114 | CPA CRRC CSA CTI DHA |
115 | Green-e GS IA IAPMO ICC |
116 | IEC IES ISO |
117 | LIHI NEMA NFPA NFRC NIST NSC |
118 | NSF NZS SCAQMD TCNA UL |
119 | US Congress USDA USDOE USEPA |
121 | WTO |
122 | NORMATIVE APPENDIX A PRESCRIPTIVE BUILDING ENVELOPE TABLES TABLE A101.1 (TABLE A-1) SINGLE-RAFTER ROOF REQUIREMENTS (I-P) (SUPERSEDES TABLE A2.4.2 IN ANSI/ASHRAE/IES STANDARD 90.1) TABLE A101.1 (TABLE A-1) SINGLE-RAFTER ROOF REQUIREMENTS (SI) (SUPERSEDES TABLE A2.4.2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
124 | NORMATIVE APPENDIX B PRESCRIPTIVE EQUIPMENT EFFICIENCY TABLES FOR THE ALTERNATE REDUCED RENEWABLES AND INCREASED EQUIPMENT EFFICIENCY APPROACH IN SECTION 701.4.1.1 (7.4.1.1) TABLE B101.1 (TABLE B-1) ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
125 | TABLE B101.1 (TABLE B-1)—continued ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
126 | TABLE B101.2 (TABLE B-2) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
127 | TABLE B101.2 (TABLE B-2)—continued ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
128 | TABLE B101.3 (TABLE B-3) ELECTRICALLY OPERATED SINGLE-PACKAGED VERTICAL AIR CONDITIONERS AND SINGLE-PACKAGED VERTICAL HEAT PUMPS AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-4 IN ANSI/ASHRAE/IES STANDARD 90.1) TABLE B101.4 (TABLE B-4) SINGLE-PACKAGED VERTICAL AIR CONDITIONERS, SINGLE-PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
129 | TABLE B101.4 (TABLE B-4)—continued SINGLE-PACKAGED VERTICAL AIR CONDITIONERS, SINGLE-PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
130 | TABLE B101.5 (TABLE B-5) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES, AND UNIT HEATERS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-5 IN ANSI/ASHRAE/IES STANDARD 90.1) |
131 | TABLE B101.6 (TABLE B-6) GAS- AND OIL-FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-6 IN ANSI/ASHRAE/IES STANDARD 90.1) |
132 | TABLE B101.7 (TABLE B-7) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-7 IN ANSI/ASHRAE/IES STANDARD 90.1) |
133 | TABLE B101.8 (TABLE B-8) PERFORMANCE REQUIREMENTS FOR SERVICE WATER HEATING EQUIPMENT (I-P) (SUPERSEDES TABLE 7.8 IN ANSI/ASHRAE/IES STANDARD 90.1) |
134 | TABLE B101.8 (TABLE B-8)—continued PERFORMANCE REQUIREMENTS FOR SERVICE WATER HEATING EQUIPMENT (I-P) (SUPERSEDES TABLE 7.8 IN ANSI/ASHRAE/IES STANDARD 90.1) TABLE B101.9 (TABLE B-9) COMMERCIAL CLOTHES WASHERS (I-P) TABLE B101.10 (TABLE B-10) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-9 IN ANSI/ASHRAE/IES STANDARD 90.1) |
135 | TABLE B101.11 (TABLE B-11) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AND APPLIED HEAT PUMP—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-10 IN ANSI/ASHRAE/IES STANDARD 90.1) |
136 | TABLE B101.11 (TABLE B-11)—continued ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AND APPLIED HEAT PUMP—MINIMUM EFFICIENCY REQUIREMENTS (I-P) (SUPERSEDES TABLE 6.8.1-10 IN ANSI/ASHRAE/IES STANDARD 90.1) |
137 | TABLE B101.1 (TABLE B-1) ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
138 | TABLE B101.1 (TABLE B-1)—continued ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
139 | TABLE B101.2 (TABLE B-2) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
140 | TABLE B101.2 (TABLE B-2)—continued ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
141 | TABLE B101.3 (TABLE B-3) ELECTRICALLY OPERATED SINGLE-PACKAGED VERTICAL AIR CONDITIONERS AND SINGLE-PACKAGED VERTICAL HEAT PUMPS AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
142 | TABLE B101.4 (TABLE B-4) SINGLE-PACKAGED VERTICAL AIR CONDITIONERS, SINGLE-PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
143 | TABLE B101.5 (TABLE B-5) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES, AND UNIT HEATERS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-5 IN ANSI/ASHRAE/IES STANDARD 90.1) |
144 | TABLE B101.6 (TABLE B-6) GAS- AND OIL-FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-6 IN ANSI/ASHRAE/IES STANDARD 90.1) |
145 | TABLE B101.7 (TABLE B-7) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-7 IN ANSI/ASHRAE/IES STANDARD 90.1) |
146 | TABLE B101.8 (TABLE B-8) PERFORMANCE REQUIREMENTS FOR SERVICE WATER HEATING EQUIPMENT (SI) (SUPERSEDES TABLE 7.8 IN ANSI/ASHRAE/IES STANDARD 90.1) |
147 | TABLE B101.8 (TABLE B-8)—continued PERFORMANCE REQUIREMENTS FOR SERVICE WATER HEATING EQUIPMENT (SI) (SUPERSEDES TABLE 7.8 IN ANSI/ASHRAE/IES STANDARD 90.1) TABLE B101.9 (TABLE B-9) COMMERCIAL CLOTHES WASHERS (SI) TABLE B101.10 (TABLE B-10) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-9 IN ANSI/ASHRAE/IES STANDARD 90.1) |
148 | TABLE B101.11 (TABLE B-11) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AND APPLIED HEAT PUMP—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-10 IN ANSI/ASHRAE/IES STANDARD 90.1) |
149 | TABLE B101.11 (TABLE B-11)—continued ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW AND APPLIED HEAT PUMP—MINIMUM EFFICIENCY REQUIREMENTS (SI) (SUPERSEDES TABLE 6.8.1-10 IN ANSI/ASHRAE/IES STANDARD 90.1) |
150 | NORMATIVE APPENDIX C PERFORMANCE OPTION FOR ENERGY EFFICIENCY SECTION C101 (C1) GENERAL |
151 | TABLE C101.1 (TABLE C1.1) MODIFICATIONS AND ADDITIONS TO ANSI/ASHRAE/IES STANDARD 90.1, APPENDIX G, TABLE G3.1 |
152 | TABLE C101.1 (TABLE C1.1) —continued MODIFICATIONS AND ADDITIONS TO ANSI/ASHRAE/IES STANDARD 90.1, APPENDIX G, TABLE G3.1 |
153 | TABLE C101.1 (TABLE C1.1) —continued MODIFICATIONS AND ADDITIONS TO ANSI/ASHRAE/IES STANDARD 90.1, APPENDIX G, TABLE G3.1 TABLE C101.2 (TABLE C1.2) PERFORMANCE MODELING OF DISTRICT ENERGY SYSTEM REQUIREMENTS |
154 | TABLE C101.2 (TABLE C1.2) —continued PERFORMANCE MODELING OF DISTRICT ENERGY SYSTEM REQUIREMENTS |
156 | NORMATIVE APPENDIX D BUILDING CONCENTRATIONS SECTION D101 (D1) BUILDING CONCENTRATIONS |
158 | INFORMATIVE APPENDIX E BUILDING ENVELOPE TABLES |
159 | TABLE E101.0 (TABLE E-0) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 0 (A,B)* (I-P) (SUPERSEDES TABLE 5.5-0 IN ANSI/ASHRAE/IES STANDARD 90.1) |
160 | TABLE E101.1 (TABLE E-1) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 1 (A,B)* (I-P) (SUPERSEDES TABLE 5.5-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
161 | TABLE E101.2 (TABLE E-2) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 2 (A,B)* (I-P) (SUPERSEDES TABLE 5.5-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
162 | TABLE E101.3 (TABLE E-3) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 3 (A,B,C)* (I-P) (SUPERSEDES TABLE 5.5-3 IN ANSI/ASHRAE/IES STANDARD 90.1) |
163 | TABLE E101.4 (TABLE E-4) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 4 (A,B,C)* (I-P) (SUPERSEDES TABLE 5.5-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
164 | TABLE E101.5 (TABLE E-5) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 5 (A,B,C)* (I-P) (SUPERSEDES TABLE 5.5-5 IN ANSI/ASHRAE/IES STANDARD 90.1) |
165 | TABLE E101.6 (TABLE E-6) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 6 (A,B)* (I-P) (SUPERSEDES TABLE 5.5-6 IN ANSI/ASHRAE/IES STANDARD 90.1) |
166 | TABLE E101.7 (TABLE E-7) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 7* (I-P) (SUPERSEDES TABLE 5.5-7 IN ANSI/ASHRAE/IES STANDARD 90.1) |
167 | TABLE E101.8 (TABLE E-8) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 8* (I-P) (SUPERSEDES TABLE 5.5-8 IN ANSI/ASHRAE/IES STANDARD 90.1) |
168 | TABLE E101.0 (TABLE E-0) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 0 (A,B)* (SI) (SUPERSEDES TABLE 5.5-0 IN ANSI/ASHRAE/IES STANDARD 90.1) |
169 | TABLE E101.1 (TABLE E-1) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 1 (A,B)* (SI) (SUPERSEDES TABLE 5.5-1 IN ANSI/ASHRAE/IES STANDARD 90.1) |
170 | TABLE E101.2 (TABLE E-2) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 2 (A,B)* (SI) (SUPERSEDES TABLE 5.5-2 IN ANSI/ASHRAE/IES STANDARD 90.1) |
171 | TABLE E101.3 (TABLE E-3) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 3 (A,B,C)* (SI) (SUPERSEDES TABLE 5.5-3 IN ANSI/ASHRAE/IES STANDARD 90.1) |
172 | TABLE E101.4 (TABLE E-4) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 4 (A,B,C)* (SI) (SUPERSEDES TABLE 5.5-4 IN ANSI/ASHRAE/IES STANDARD 90.1) |
173 | TABLE E101.5 (TABLE E-5) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 5 (A, B, C)* (SI) (SUPERSEDES TABLE 5.5-5 IN ANSI/ASHRAE/IES STANDARD 90.1) |
174 | TABLE E101.6 (TABLE E-6) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 6 (A,B)* (SI) (SUPERSEDES TABLE 5.5-6 IN ANSI/ASHRAE/IES STANDARD 90.1) |
175 | TABLE E101.7 (TABLE E-7) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 7* (SI) (SUPERSEDES TABLE 5.5-7 IN ANSI/ASHRAE/IES STANDARD 90.1) |
176 | TABLE E101.8 (TABLE E-8) EXAMPLE BUILDING ENVELOPE COMPLIANCE VALUES FOR CLIMATE ZONE 8* (SI) (SUPERSEDES TABLE 5.5-8 IN ANSI/ASHRAE/IES STANDARD 90.1) |
178 | INFORMATIVE APPENDIX F INTEGRATED DESIGN SECTION F101 (F1) INTEGRATED DESIGN PROCESS/INEGRATED PROJECT DELIVERY |
179 | FIGURE F101.1 (FIGURE F-1) SAMPLE CHARRETTE DESIGN MATRICES |
180 | INFORMATIVE APPENDIX G INFORMATIVE REFERENCES AIA AISC ASHRAE APBP |
181 | ASTM BSI BUSMethodology CBE CRI CSA DGS |
182 | DHHS ATSDR EPA FSC GSA ICC IES ITE |
183 | MTS NIBS NIST NREL RFCI SFI SMACNA SRI |
184 | UL |
186 | INFORMATIVE APPENDIX H OPTION FOR ENERGY EFFICIENCY USINGTHE IECC PRESCRIPTIVE COMPLIANCE PATH SECTION H101 (H1) GENERAL SECTION H201 (H2) COMPLIANCE SECTION H301 (H3) PRESCRIPTIVE REQUIREMENTS |
192 | INFORMATIVE APPENDIX I zEPI CONVERSION METHODOLOGY TABLE I101.1 (TABLE I-1) zEPI CONVERSION FACTORS, M |
194 | INFORMATIVE APPENDIX J DERIVATION OF SOURCE ENERGY CONSERVATION FACTORS AND CO2e EMISSION FACTORS SECTION J101 (J1) SOURCE ENERGY CONVERSION FACTORS EQUATION J-1 |
195 | TABLE J101.1 (TABLE J1-1) SOURCE ENERGY CONVERSION FACTORS FOR FUEL DELIVERED TO BUILDINGS TABLE J101.2 (TABLE J1-2) HEAT RATES FOR ELECTRIC GENERATION (2017) TABLE J101.3 (TABLE J1-3) UNITED STATES ELECTRICITY GENERATION MIX FOR 2017 |
196 | TABLE J101.4 (TABLE J1-4) UNITED STATES NET GENERATION FOR 2017 SECTION J102 (J2) CARBON DIOXIDE EQUIVALENT (CO2E) EMISSIONS EQUATION J-2 |
197 | TABLE J102.1 (TABLE J2-1) DIRECT AND INDIRECT EMISSIONS FROM FOSSIL FUELS USE TABLE J201.2 (TABLE J2-2) GLOBAL WARMING POTENTIAL (UNITLESS MULTIPLIERS) (SOURCE: IPCC 2013, AR4 WITHOUT CLIMATE CARBON FEEDBACKS) |
198 | TABLE J102.3 (TABLE J2-3) EFFICIENCY ASSUMPTIONS FOR DISTRICT ENERGY SYSTEMS |
200 | INFORMATIVE APPENDIX K ADDITIONAL GUIDANCE FOR FUNCTIONAL AND PERFORMANCE TESTING (FPT) AND THE COMMISSIONING (CX) PROCESS SECTION K101 (K1) PROVIDER QUALIFICATIONS SECTION K201 (K2) CX DOCUMENTATION |
201 | TABLE K101.1 (TABLE K-1) TYPICAL CX PROCESS ACTIVITIES, DELIVERABLES, AND RESPONSIBILITIES |
204 | INFORMATIVE APPENDIX L REQUIREMENTS THAT OVERLAP WITH CORE ELEMENTS OF THE LEED RATING SYSTEM TABLE L101.1 (TABLE L-1) REQUIREMENTS THAT ALIGN WITH LEED TABLE L101.1 (TABLE L-1)—continued REQUIREMENTS THAT ALIGN WITH LEED |
205 | TABLE L101.1 (TABLE L-1)—continued REQUIREMENTS THAT ALIGN WITH LEED TABLE L101.1 (TABLE L-1)—continued REQUIREMENTS THAT ALIGN WITH LEED |
206 | INFORMATIVE APPENDIX M OPTION FOR RESIDENTIAL COMPLIANCE USING THE NATIONAL GREEN BUILDING STANDARD SECTION M101 GENERAL |
208 | INFORMATIVE APPENDIX N ADDENDA DESCRIPTION INFORMATION |
209 | TABLE N101.1 (TABLE N-1) ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
210 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
211 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
212 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
213 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
214 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
215 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
216 | TABLE N101.1 (TABLE N-1) —continued ADDENDA TO ANSI/ASHRAE/ICC/IES/USGBC STANDARD 189.1-2017 |
218 | ANNEX 1 REFERENCED STANDARD REPRODUCTION ANNEX ASHRAE STANDARD 169 |
219 | FIGURE ANNEX 101.1 (FIGURE ANNEX 1-1) ASHRAE STANDARD 169-2013, FIGURE B-1: CLIMATE ZONES FOR UNITED STATES COUNTIES |
220 | SECTION ANNEX 101 (ANNEX 1-1) ASHRAE STANDARD 169-2013, SECTION A3: CLIMATE ZONE DEFINITIONS SECTION A301 (A3) CLIMATE ZONE DEFINITIONS |
221 | TABLE ANNEX 101.1 (TABLE ANNEX 1-1) ASHRAE STANDARD 169-2013, TABLE A-3: THERMAL CLIMATE ZONE DEFINITIONS |
222 | ICC EVALUATION SERVICE |
223 | ICC PLAN REVIEW SERVICES |
224 | ICC MEMBERSHIP |
225 | TELEWORK WITH ICC DIGITAL CODES PREMIUM |