ICC IgCC Commentary 2015
$118.08
International Green Construction Code and Commentary
Published By | Publication Date | Number of Pages |
ICC | 2015 | 343 |
This comprehensive publication provides a convenient reference for regulations in the 2015 International Green Construction Code® (IgCC®).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2015 IgCC® CODE AND COMMENTARY |
2 | 2015 IgCC® CODE AND COMMENTARY TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
8 | CHAPTER 1: SCOPE AND ADMINISTRATION GENERAL COMMENTS PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL |
10 | SECTION 102 APPLICABILITY |
11 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DUTIES AND POWERS OF THE CODE OFFICIAL |
12 | SECTION 104 CONSTRUCTION DOCUMENTS SECTION 105 APPROVAL |
14 | SECTION 106 PERMITS SECTION 107 INSPECTIONS SECTION 108 BOARD OF APPEALS |
15 | SECTION 109 CERTIFICATE OF OCCUPANCY SECTION 109 CERTIFICATE OF OCCUPANCY BIBLIOGRAPHY |
16 | CHAPTER 2: DEFINITIONS GENERAL COMMENTS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
36 | BIBLIOGRAPHY |
38 | CHAPTER 3: JURISDICTIONAL REQUIREMENTS GENERAL COMMENTS SECTION 301 GENERAL SECTION 302 JURISDICTIONAL REQUIREMENTS |
40 | TABLE 302.1 REQUIREMENTS DETERMINED BY THE JURISDICTION BIBLIOGRAPHY |
42 | CHAPTER 4: SITE DEVELOPMENT AND LAND USE GENERAL COMMENTS PURPOSE SECTION 401 GENERAL |
43 | SECTION 402 PRESERVATION OF NATURAL RESOURCES |
46 | SECTION 403 STORMWATER MANAGEMENT |
47 | SECTION 404 LANDSCAPE IRRIGATION AND OUTDOOR FOUNTAINS |
49 | SECTION 405 MANAGEMENT OF VEGETATION, SOILS AND EROSION CONTROL |
52 | TABLE 405.1.2 MAXIMUM CONE PENETROMETER READINGS |
53 | SECTION 406 BUILDING SITE WASTE MANAGEMENT |
54 | SECTION 407 TRANSPORTATION IMPACT |
55 | TABLE 407.3 BICYCLE PARKING |
57 | SECTION 408 HEAT ISLAND MITIGATION |
59 | TABLE 408.3.1 REFLECTANCE AND EMITTANCE |
60 | SECTION 409 SITE LIGHTING TABLE 409.1.1 LIGHT POLLUTION ZONES |
61 | TABLE 409.2 UPLIGHT RATINGS TABLE 409.3(1) MAXIMUM GLARE RATINGS FOR BUILDING-MOUNTED LUMINAIRES WITH THE BACKLIGHT ORIENTED TOWARDS THE BUILDING TABLE 409.3(2) MAXIMUM ALLOWABLE BACKLIGHT AND GLARE RATINGS BIBLIOGRAPHY |
64 | CHAPTER 5: MATERIAL RESOURCE CONSERVATION AND EFFICIENCY GENERAL COMMENTS PURPOSE SECTION 501 GENERAL SECTION 502 CONSTRUCTION MATERIAL MANAGEMENT |
65 | SECTION 503 CONSTRUCTION WASTE MANAGEMENT |
67 | FIGURE 503.1 CONSTRUCTION WASTE SECTION 504 WASTE MANAGEMENT AND RECYCLING SECTION 505 MATERIAL SELECTION |
75 | FIGURE 505.3 SAMPLE MINIMUM REPORTING CRITERIA FOR IgCC SECTION 505.3 WHOLE BUILDING LIFE CYCLE ASSESSMENT |
77 | SECTION 506 LAMPS |
80 | CHAPTER 6: ENERGY CONSERVATION, EFFICIENCY AND CO2E EMISSION REDUCTION GENERAL COMMENTS PURPOSE SECTION 601 GENERAL |
82 | SECTION 602 PERFORMANCE-BASED COMPLIANCE EQUATION 6-1 |
83 | TABLE 602.2.1.1 ELECTRICITY GENERATION ENERGY CONVERSION FACTORS BY EPA eGRID SUB-REGION |
84 | TABLE 602.2.1.2 U.S. AVERAGE BUILDING FUELS ENERGY CONVERSION FACTORS BY FUEL TYPE EQUATION 6-2 |
85 | TABLE 602.3.1 ELECTRICITY EMISSION RATE BY EPA eGRID SUB-REGION TABLE 602.3.2 FOSSIL FUEL EMISSION FACTORS SECTION 603 ENERGY METERING, MONITORING AND REPORTING |
86 | TABLE 603.2 ENERGY USE CATEGORIES |
90 | SECTION 604 AUTOMATED DEMAND-RESPONSE (AUTO-DR) INFRASTRUCTURE |
92 | SECTION 605 BUILDING ENVELOPE SYSTEMS |
93 | FIGURE 605.1.1 CALCULATING PRESCRIPTIVE ENVELOPE VALUES |
95 | SECTION 606 BUILDING MECHANICAL SYSTEMS TABLE 606.2.2.1 ENERGY-EFFICIENCY CRITERIA FOR GROUND SOURCE HEAT PUMPS |
97 | EQUATION 6-3 EQUATION 6-4 |
98 | TABLE 606.4 MINIMUM PIPE INSULATION THICKNESS |
99 | TABLE 606.5.1 EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS |
100 | SECTION 607 BUILDING SERVICE WATER HEATING SYSTEMS |
101 | SECTION 608 BUILDING ELECTRICAL POWER AND LIGHTING SYSTEMS |
106 | SECTION 609 SPECIFIC APPLIANCES AND EQUIPMENT TABLE 609.1 APPLIANCES AND EQUIPMENT COVERED BY FEDERAL EFFICIENCY STANDARDS |
109 | TABLE 609.2.3 COMMERCIAL FOOD SERVICE EQUIPMENT—ENERGY-EFFICIENCY AND WATER USE REQUIREMENTS |
110 | TABLE 609.2.3—continued COMMERCIAL FOOD SERVICE EQUIPMENT—ENERGY-EFFICIENCY AND WATER USE REQUIREMENTS |
111 | SECTION 610 ONSITE RENEWABLE ENERGY SYSTEMS |
112 | SECTION 611 ENERGY SYSTEMS COMMISSIONING AND COMPLETION |
115 | SECTION 612 OUTCOME-BASED PATHWAY REQUIREMENTS TABLE 612.1 REFERENCE ANNUAL ENERGY USE INDEX (EUIr) |
116 | EQUATION 6-6 EQUATION 6-7 EQUATION 6-8 |
118 | CHAPTER 7: WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY GENERAL COMMENTS PURPOSE SECTION 701 GENERAL |
119 | TABLE 701.2.1 METERING REQUIREMENTS SECTION 702 FIXTURES, FITTINGS, EQUIPMENT AND APPLIANCES |
120 | TABLE 702.1 MAXIMUM FIXTURE AND FITTING FLOW RATES FOR REDUCED WATER CONSUMPTION |
122 | TABLE 702.5.4 MAXIMUM WATER CONSUMPTION FOR COMMERCIAL DISHWASHERS |
124 | TABLE 702.7.2(1) VOLUME AND MAXIMUM LENGTH OF PIPE OR TUBE OF A TYPE UNKNOWN OR NOT COVERED |
125 | TABLE 702.7.2(2) VOLUME AND MAXIMUM LENGTH OF TYPE K COPPER TUBING TABLE 702.7.2(3) VOLUME AND MAXIMUM LENGTH OF TYPE L COPPER TUBING |
126 | TABLE 702.7.2(4) VOLUME AND MAXIMUM LENGTH OF TYPE M COPPER TUBING TABLE 702.7.2(5) VOLUME AND MAXIMUM LENGTH OF CPVC TUBING, CTS TABLE 702.7.2(6) VOLUME AND MAXIMUM LENGTH OF CPVC PIPE, SCHEDULE 40 |
127 | TABLE 702.7.2(7) VOLUME AND MAXIMUM LENGTH OF CPVC PIPE, SCHEDULE 80 TABLE 702.7.2(8) VOLUME AND MAXIMUM LENGTH OF PE-AL-PE TUBING TABLE 702.7.2(9) VOLUME AND MAXIMUM LENGTH OF PEX AND PE-RT TUBING, CTS |
128 | TABLE 702.7.2(10) VOLUME AND MAXIMUM LENGTH OF PEX-AL-PEX TUBING |
130 | SECTION 703 HVAC SYSTEMS AND EQUIPMENT |
132 | TABLE 703.7.6 MINIMUM CYCLES OF CONCENTRATION FOR DISCHARGE WATER |
133 | SECTION 704 WATER TREATMENT DEVICES AND EQUIPMENT |
134 | BIBLIOGRAPHY |
136 | CHAPTER 8: INDOOR ENVIRONMENTAL QUALITY AND COMFORT GENERAL COMMENTS PURPOSE SECTION 801 GENERAL SECTION 802 BUILDING CONSTRUCTION FEATURES, OPERATIONS AND MAINTENANCE FACILITATION |
137 | SECTION 803 HVAC SYSTEMS |
139 | SECTION 804 SPECIFIC INDOOR AIR QUALITY AND POLLUTANT CONTROL MEASURES |
140 | TABLE 804.2 MAXIMUM CONCENTRATION OF AIR POLLUTANTS SECTION 805 PROHIBITED MATERIALS SECTION 806 MATERIAL EMISSIONS AND POLLUTANT CONTROL |
141 | TABLE 806.1 COMPOSITE PRODUCTS EMISSIONS |
142 | TABLE 806.2(1) SITE-APPLIED ADHESIVE AND SEALANT VOC LIMITS TABLE 806.2(2) VOC EMISSION LIMITS |
144 | TABLE 806.3(1) VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS TABLE 806.3(1)—continued VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS TABLE 806.3(2) ARCHITECTURAL COATINGS VOC EMISSION LIMITS TABLE 806.4(1) FLOORING DEEMED TO COMPLY WITH VOC EMISSION LIMITS TABLE 806.4(2) FLOORING VOC EMISSION LIMITS TABLE 806.5(1) CEILING AND WALL SYSTEMS DEEMED TO COMPLY WITH VOC EMISSION LIMITS TABLE 806.5(2) ACOUSTICAL CEILING TILES AND WALL SYSTEMS VOC EMISSION LIMITS TABLE 806.6(1) INSULATION VOC EMISSION LIMITS |
145 | TABLE 806.6(2) INSULATION MANUFACTURED WITHOUT FORMALDEHYDE VOC EMISSION LIMITS SECTION 807 ACOUSTICS |
146 | TABLE 807.3.1 MAXIMUM PERMISSIBLE OUTDOOR A-WEIGHTED SOUND LEVELS |
147 | TABLE 807.3.2 MAXIMUM PERMISSIBLE INDOOR BACKGROUND SOUND IN ROOMS |
148 | SECTION 808 DAYLIGHTING |
149 | EQUATION 8-1 |
150 | EQUATION 8-2 TABLE 808.3.1 MINIMUM EFFECTIVE APERTURE |
153 | FIGURE 808.4 SKY TYPES |
154 | CHAPTER 9: COMMISSIONING, INSPECTIONS, OPERATIONS AND MAINTENANCE GENERAL COMMENTS PURPOSE SECTION 901 GENERAL SECTION 902 SPECIAL INSPECTION AND COMMISSIONING |
155 | TABLE 902.1 COMMISSIONING AND INSPECTION PLAN REQUIREMENTS |
156 | TABLE 902.1—continued COMMISSIONING AND INSPECTION PLAN REQUIREMENTS TABLE 902.2 REQUIRED SPECIAL INSPECTIONS |
159 | SECTION 903 BUILDING OPERATIONS AND MAINTENANCE DOCUMENTATION |
162 | CHAPTER 10: EXISTING BUILDINGS GENERAL COMMENTS SECTION 1001 GENERAL |
163 | SECTION 1002 ADDITIONS SECTION 1003 ALTERATIONS TO EXISTING BUILDINGS |
164 | TABLE 1003.2 MINIMUM VALUES FOR ADDITIONAL REQUIREMENTS TO ALTERATIONS |
167 | SECTION 1004 CHANGE OF OCCUPANCY SECTION 1005 HISTORIC BUILDINGS SECTION 1006 DEMOLITION SECTION 1007 JURISDICTIONAL REQUIREMENTS |
170 | CHAPTER 11: EXISITING GENERAL COMMENTS SECTION 1101 GENERAL |
171 | SECTION 1102 ADDITIONS SECTION 1103 ALTERATIONS TO EXISTING BUILDING SITES SECTION 1104 CHANGE OF OCCUPANCY |
172 | SECTION 1105 HISTORIC BUILDING SITES |
174 | CHAPTER 12: REFERENCED STANDARDS GENERAL COMMENTS PURPOSE |
175 | FIGURE 12 REFERENCED STANDARDS |
176 | AHRI AMCA APA ARB ASA ASABE ASHE |
177 | ASME ASHRAE ASSE ASTM |
178 | CCR CDPH |
179 | CRRC CSA DOC EPA FSC |
180 | ICC IEC IES ISO |
181 | NEMA NFPA NSC NSF SCAQMD |
182 | SFI SMACNA SRCC TCIA TCNA TMS |
183 | UL USDA |
184 | APPENDIX A: PROJECT ELECTIVES GENERAL COMMENTS |
185 | SECTION A101 GENERAL SECTION A102 DEFINITIONS |
186 | SECTION A103 APPLICABILITY AND CONFORMANCE SECTION A104 SITE PROJECT ELECTIVES |
187 | TABLE A103.2 PROJECT ELECTIVES |
188 | TABLE A103.2—continued PROJECT ELECTIVES SECTION A105 MATERIAL RESOURCE CONSERVATION AND EFFICIENCY |
189 | SECTION A106 ENERGY CONSERVATION, EFFICIENCY AND EARTH ATMOSPHERIC QUALITY |
190 | SECTION A107 WATER RESOURCE CONSERVATION AND EFFICIENCY |
191 | SECTION A108 INDOOR ENVIRONMENTAL QUALITY AND COMFORT |
192 | SECTION A109 REFERENCED STANDARDS |
194 | APPENDIX B: POST-OCCUPANCY COMMISSIONING REPORTING SECTION B101 GENERAL TABLE B101.1 POST-OCCUPANCY COMMISSIONING REPORTING |
196 | INDEX |
204 | ANSI/ASHRAE/USGBC/IES STANDARD 189.1-2014 STANDARD FOR THE DESIGN OF HIGH-PERFORMANCE GREEN BUILDINGS |
205 | ASHRAE STANDARD PROJECT COMMITTEE 189.1 |
206 | ASHRAE STANDARDS COMMITTEE 2014–2015 SPECIAL NOTE DISCLAIMER ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS |
208 | CONTENTS |
209 | FOREWORD |
211 | 1. PURPOSE 2. SCOPE 3. DEFINITIONS, ABBREVIATIONS, AND ACRONYMS |
217 | 4. ADMINISTRATION AND ENFORCEMENT |
218 | 5. SITE SUSTAINABILITY |
221 | TABLE 5.3.6.2A MAXIMUM ALLOWABLE GLARE RATINGS FOR BUILDING-MOUNTED LUMINAIRES WITHIN TWO MOUNTING HEIGHTS OF ANY PROPERTY LINE TABLE 5.3.6.2B MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE RATINGS TABLE 5.3.6.3 MAXIMUM ALLOWABLE PERCENTAGE OF UPLIGHT |
223 | 6. WATER USE EFFICIENCY |
224 | TABLE 6.3.2.1 PLUMBING FIXTURES AND FITTINGS REQUIREMENTS |
225 | TABLE 6.3.3A SUBSYSTEM WATER MEASUREMENT THRESHOLDS TABLE 6.3.3B WATER SUPPLY SOURCE MEASUREMENT THRESHOLDS |
227 | 7. ENERGY EFFICIENCY TABLE 7.3.3.1A ENERGY SOURCE THRESHOLDS |
228 | TABLE 7.3.3.1B SYSTEM ENERGY USE THRESHOLDS |
229 | TABLE 7.4.2.6 SHGC MULTIPLIERS FOR PERMANENT PROJECTIONS |
230 | TABLE 7.4.3.3 MINIMUM SYSTEM SIZE FOR WHICH AN ECONOMIZER IS REQUIRED |
231 | TABLE 7.4.3.7 MAXIMUM NET EXHAUST FLOW RATE IN CFM PER LINEAR FOOT OF HOOD LENGTH |
232 | TABLE 7.4.6.1A LPD FACTORS WHEN USING THE BUILDING AREA METHOD |
233 | TABLE 7.4.6.1B LIGHTING POWER DENSITY FACTORS WHEN USING THE SPACE-BY-SPACE METHOD |
234 | TABLE 7.4.6.1C LIGHTING POWER ALLOWANCE FACTORS |
236 | TABLE 7.5.2A PERFORMANCE OPTION A: ENERGY COST AND CO2E REDUCTIONS TABLE 7.5.2B CO2E EMISSION FACTORS |
237 | 8. INDOOR ENVIRONMENTAL QUALITY (IEQ) |
240 | TABLE 8.4.1.2 MINIMUM SIDELIGHTING EFFECTIVE APERTURE |
244 | 9. THE BUILDING’S IMPACT ON THE ATMOSPHERE, MATERIALS, AND RESOURCES |
245 | TABLE 9.3.5 MAXIMUM MERCURY CONTENT FOR ELECTRIC LAMPS |
248 | 10. CONSTRUCTION AND PLANS FOR OPERATION |
250 | EQUATION 10-1 TABLE 10.3.1.4 MAXIMUM CONCENTRATION OF AIR POLLUTANTS RELEVANT TO IAQ |
253 | TABLE 10.3.2.3 MINIMUM DESIGN SERVICE LIFE FOR BUILDINGS |
255 | 11. NORMATIVE REFERENCES AHRI ANSI ASME ASHRAE |
256 | AHAM ASTM BIFMA |
257 | CARB CDPH CANADIAN GENERAL STANDARDS BOARD CITES CRRC CTI |
258 | CTI GREEN-E GREEN SEAL ILLUMINATING ENERGINEERING SOCIETY OF NORTH AMERICA IAPMO ISO IA |
259 | NATIONAL ARCHIVES AND RECORDS ADMINISTRATION NEMA NATIONAL FIRE PROTECTION ASSOCIATION NATURAL STONE COUNCIL NSF SCAQMD TILE COUNCIL OF NORTH AMERICA |
260 | UNDERWRITERS LABORATORIES UNITED STATES CONGRESS USDA U.S. DOE EPA |
262 | EPA WTO |
263 | NORMATIVE APPENDIX A CLIMATE ZONES AND PRESCRIPTIVE BUILDING ENVELOPE AND DUCT INSULATION TABLES FIGURE U.S. CLIMATE ZONE MAP (ASHRAE Transactions 109(1), Briggs et al., 2003) |
264 | TABLE A-1 (Supersedes Table A2.4.2 in ANSI/ASHRAE/IES Standard 90.1) SINGLE-RAFTER ROOF REQUIREMENTS (I-P) TABLE A-2 (Supersedes Table 6.8.2-1 in ANSI/ASHRAE/IES Standard 90.1) MINIMUM DUCT INSULATION R-VALUEa HEATING- AND COOLING-ONLY SUPPLY DUCTS AND RETURN DUCTS (I-P) |
265 | TABLE A-3 (Supersedes Table 6.8.2-2 in ANSI/ASHRAE/IES Standard 90.1) MINIMUM DUCT INSULATION R-VALUEa COMBINED HEATING AND COOLING SUPPLY DUCTS AND RETURN DUCTS (I-P) |
266 | TABLE A-1 (Supersedes Table A2.4.2 in ANSI/ASHRAE/IES Standard 90.1) SINGLE-RAFTER ROOF REQUIREMENTS (SI) TABLE A-2 (Supersedes Table 6.8.2A in ANSI/ASHRAE/IES Standard 90.1) MINIMUM DUCT INSULATION R-VALUEa HEATING- AND COOLING-ONLY SUPPLY DUCTS AND RETURN DUCTS (SI) |
267 | TABLE A-3 (Supersedes Table 6.8.2A in ANSI/ASHRAE/IES Standard 90.1) MINIMUM DUCT INSULATION R-VALUEa COMBINED HEATING AND COLLING SUPPLY DUCTS AND RETURN DUCTS (SI) |
268 | NORMATIVE APPENDIX B PRESCRIPTIVE EQUIPMENT EFFICIENCY TABLES FOR THE ALTERNATE REDUCED RENEWABLES AND INCREASED EQUIPMENT EFFICIENCY APPROACH IN SECTION 7.4.1.1.2 TABLE B-1 (Supersedes Table 6.8.1-1 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS (I-P) |
270 | TABLE B-2 (Supersedes Table 6.8.1-2 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS MINIMUM EFFICIENCY REQUIREMENTS (I-P) |
271 | TABLE B-2 (Supersedes Table 6.8.1-2 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS MINIMUM EFFICIENCY REQUIREMENTS (I-P) (Continued) |
272 | TABLE B-3 (Supersedes Table 6.8.1-3 in ANSI/ASHRAE/IES Standard 90.1-2013) WATER-CHILLING PACKAGES—EFFICIENCY REQUIREMENTS (I-P)a,b,e |
273 | TABLE B-3 (Supersedes Table 6.8.1-3 in ANSI/ASHRAE/IES Standard 90.1-2013) WATER-CHILLING PACKAGES—EFFICIENCY REQUIREMENTS (I-P)a,b,e (Continued) |
274 | TABLE B-4 (Supersedes Table 6.8.1-4 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED PACKAGED AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE PACKAGED VERTICAL AIR CONDITIONERS, SINGLE PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) |
275 | TABLE B-5 (Supersedes Table 6.8.1-4 in ANSI/ASHRAE/IES Standard 90.1) SINGLE PACKAGED VERTICAL AIR CONDITIONERS, SINGLE PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) |
276 | TABLE B-6 (Supersedes Table 6.8.1-5 in ANSI/ASHRAE/IES Standard 90.1) WARM AIR FURNACE AND COMBUSTION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES, AND UNIT HEATERS (I-P) |
277 | TABLE B-7 (Supersedes Table 6.8.1-6 in ANSI/ASHRAE/IES Standard 90.1) GAS- AND OIL-FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS (I-P) |
278 | TABLE B-8 (Supersedes Table 6.8.1-7 in ANSI/ASHRAE/IES Standard 90.1) PERFORMANCE REQUIREMENTS FOR HEAT-REJECTION EQUIPMENT (I-P) |
279 | TABLE B-9 (Supersedes Table 7.8 in ANSI/ASHRAE/IES Standard 90.1) PERFORMANCE REQUIREMENTS FOR WATER HEATING EQUIPMENT (I-P) |
280 | TABLE B-10 COMMERCIAL REFRIGERATOR AND FREEZERS (I-P) TABLE B-11 COMMERCIAL CLOTHES WASHERS (I-P) TABLE B-12 Supersedes Table 6.8.1-9 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) AIR CONDITIONERS MINIMUM EFFICIENCY (I-P) |
281 | TABLE B-13 (Supersedes Table 6.8.1-10 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) HEAT-PUMP AIR CONDITIONERS MINIMUM EFFICIENCY (I-P) |
282 | TABLE B-13 (Supersedes Table 6.8.1-10 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) HEAT-PUMP AIR CONDITIONERS MINIMUM EFFICIENCY (I-P) (Continued) |
283 | TABLE B-14 COMMERCIAL REFRIGERATION MINIMUM EFFICIENCY REQUIREMENTS (I-P UNITS) |
284 | TABLE B-15 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS MINIMUM NOMINAL EFFICIENCIES BY TRANSFORMER RATING IN KILOVOLT-AMPERES (kVA) |
285 | TABLE B-1 (Supersedes Table 6.8.1-1 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS (SI) |
286 | TABLE B-1 (Supersedes Table 6.8.1-1 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS (SI) (Continued) |
287 | TABLE B-2 (Supersedes Table 6.8.1-2 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS MINIMUM EFFICIENCY REQUIREMENTS (SI) |
288 | TABLE B-2 (Supersedes Table 6.8.1-2 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS MINIMUM EFFICIENCY REQUIREMENTS (SI) (Continued) |
289 | TABLE B-3 (Supersedes Table 6.8.1-3 in ANSI/ASHRAE/IES Standard 90.1-2013) WATER-CHILLING PACKAGES—EFFICIENCY REQUIREMENTS (SI)a,b,e |
290 | TABLE B-3 (Supersedes Table 6.8.1-3 in ANSI/ASHRAE/IES Standard 90.1-2013) WATER-CHILLING PACKAGES—EFFICIENCY REQUIREMENTS (SI)a,b,e (Continued) |
291 | TABLE B-4 (Supersedes Table 6.8.1-4 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE PACKAGED VERTICAL AIR CONDITIONERS, SINGLE PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR CONDITIONERS HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) |
292 | TABLE B-5 (Supersedes Table 6.8.1-4 in ANSI/ASHRAE/IES Standard 90.1) SINGLE PACKAGED VERTICAL AIR CONDITIONERS, SINGLE PACKAGED VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR-CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (SI) |
293 | TABLE B-6 (Supersedes Table 6.8.1-5 in ANSI/ASHRAE/IES Standard 90.1)WARM-AIR FURNACE AND COMBUSTION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS (SI) |
294 | TABLE B-7 (Supersedes Table 6.8.1-6 in ANSI/ASHRAE/IES Standard 90.1) GAS- AND OIL-FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS (SI) |
295 | TABLE B-8 (Supersedes Table 6.8.1-7 in ANSI/ASHRAE/IES Standard 90.1) PERFORMANCE REQUIREMENTS FOR HEAT-REJECTION EQUIPMENT (SI) |
296 | TABLE B-9 (Supersedes Table 7.8 in ANSI/ASHRAE/IES Standard 90.1) PERFORMANCE REQUIREMENTS FOR WATER HEATING EQUIPMENT (SI) |
297 | TABLE B-10 COMMERCIAL REFRIGERATOR AND FREEZERS (SI) TABLE B-11 COMMERCIAL CLOTHES WASHERS (SI) TABLE B-12 (Supersedes Table 6.8.1-9 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) AIR CONDITIONERS MINIMUM EFFICIENCY (SI) |
298 | TABLE B-13 (Supersedes Table 6.8.1-10 in ANSI/ASHRAE/IES Standard 90.1) ELECTRICALLY OPERATED VARIABLE-REFRIGERANT-FLOW (VRF) HEAT-PUMP AIR CONDITONERS MINIMUM EFFICIENCY (SI) |
300 | TABLE B-14 COMMERCIAL REFRIGERATION MINIMUM EFFICIENCY REQUIREMENTS (SI UNITS) |
301 | NORMATIVE APPENDIX C PERFORMANCE OPTION FOR ENERGY EFFICIENCY C1. GENERAL |
303 | TABLE C1.1 MODIFICATIONS AND ADDITIONS TO TABLE G3.1 OF APPENDIX G IN ANSI/ASHRAE/IES STANDARD 90.1 |
304 | TABLE C1.1 MODIFICATIONS AND ADDITIONS TO TABLE G3.1 OF APPENDIX G IN ANSI/ASHRAE/IES STANDARD 90.1 (Continued) |
305 | TABLE C1.1 MODIFICATIONS AND ADDITIONS TO TABLE G3.1 OF APPENDIX G IN ANSI/ASHRAE/IES STANDARD 90.1 (Continued) |
306 | NORMATIVE APPENDIX D BUILDING CONCENTRATIONS D1. BUILDING CONCENTRATIONS |
307 | INFORMATIVE APPENDIX E BUILDING ENVELOPE TABLES |
308 | TABLE E-1 (Supersedes Table 5.5-1 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 1 (A,B)* (I-P) |
309 | TABLE E-2 (Supersedes Table 5.5-2 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 2 (A,B)* (I-P) |
310 | TABLE E-3 (Supersedes Table 5.5-3 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 3 (A,B,C)* (I-P) |
311 | TABLE E-4 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)* (I-P) |
312 | TABLE E-5 (Supersedes Table 5.5-5 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5 (A,B,C)* (I-P) |
313 | TABLE E-6 (Supersedes Table 5.5-6 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6 (A,B)* (I-P) |
314 | TABLE E-7 (Supersedes Table 5.5-7 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 7* (I-P) |
315 | TABLE E-8 (Supersedes Table 5.5-8 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 8* (I-P) |
316 | TABLE E-1 (Supersedes Table 5.5-1 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 1 (A,B)* (SI) |
317 | TABLE E-2 (Supersedes Table 5.5-2 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 2 (A,B)* (SI) |
318 | TABLE E-3 (Supersedes Table 5.5-3 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 3 (A,B,C)* (SI) |
319 | TABLE E-4 (Supersedes Table 5.5-4 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)* (SI) |
320 | TABLE E-5 (Supersedes Table 5.5-5 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5 (SI) |
321 | TABLE E-6 (Supersedes Table 5.5-6 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6 (A,B)* (SI) |
322 | TABLE E-7 (Supersedes Table 5.5-7 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMAGE ZONE 7* (SI) |
323 | TABLE E-8 (Supersedes Table 5.5-8 in ANSI/ASHRAE/IES Standard 90.1) BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 8* (SI) |
324 | INFORMATIVE APPENDIX F INTEGRATED DESIGN F1. INTEGRATED DESIGN PROCESS/INTEGRATED PROJECT DELIVERY |
325 | FIGURE F-1 SAMPLE CHARRETTE DESIGN MATRICES |
326 | INFORMATIVE APPENDIX G INFORMATIVE REFERENCES AIA AMERICAN INSTITUTE OF STEEL CONSTRUCTION ASHRAE ASSOCIATION OF PEDESTRIAN AND BICYCLE PROFESSIONALS ASTM BRITISH STANDARDS INSTITUTE |
327 | CALIFORNIA ENVIRONMENTAL PROTECTION AGENCY, OFFICE OF ENVIRONMENTAL HEALTH HAZARD ASSESSMENT CSA CARPET AND RUG INSTITUE COOL ROOF RATING COUNCIL FSC ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA INSTITUE OF TRANSPORTATION ENGINEERS MTS NIBS NREL |
328 | RESILIENT FLOOR COVERING INSTITUTE SMACNA STATE OF CALIFORNIA, DEPARTMENT OF GENERAL SERVICES, PROCUREMENT DIVISION STEEL RECYCLING INSTITUTE SFI UL GREENGUARD GOLD UNITED STATES DEPRTMENT OF HEALTH AND HUMAN SERVICES ATSDR UNITED STATES DOE UNITED STATES EPA UNITED STATES GSA |
329 | INFORMATIVE APPENDIX H ADDENDA DESCRIPTION INFORMATION TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 |
330 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 (Continued) |
331 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 (Continued) |
332 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 (Continued) |
333 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 (Continued) |
334 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/USGVC/IES STANDARD 189.1-2011 (Continued) |
336 | NOTICE INSTRUCTIONS FOR SUBMITTING A PROPOSED CHANGE TO THIS STANDARD UNDER CONTINUOUS MAINTENANCE ELECTRONIC PREPARATION/SUBMISSION OF FORM FOR PROPOSING CHANGES |
337 | FORM FOR SUBMITTAL OF PROPOSED CHANGE TO AN ASHRAE STANDARD UNDER CONTINUOUS MAINTENANCE |
338 | POLICY STATEMENT DEFINING ASHRAE’S CONCERN FOR THE ENVIRONMENTAL IMPACT OF ITS ACTIVITIES |
339 | IMPORTANT NOTICES ABOUT THIS STANDARD |
340 | ICC EVALUATION SERVICE |
341 | ICC TRAINING AND EDUCATION DEPARTMENT |
342 | SOLAR RATING & CERTIFICATION CORPORATION |
343 | GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED |