ICC IMC Commentary 2018 1stPrint
$80.71
International Mechanical Code and Commentary
Published By | Publication Date | Number of Pages |
ICC | 2018 |
This comprehensive publication provides a convenient reference for regulations in the 2018 International Mechanical Code® (IMC®).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2018 IMC® CODE AND COMMENTARY |
2 | 2018 IMC® CODE AND COMMENTARY TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
8 | CHAPTER 1: SCOPE AND ADMINISTRATION GENERAL COMMENTS PURPOSE |
9 | PART 1–SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
12 | PART 2–ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION |
13 | SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
14 | SECTION 105 APPROVAL |
16 | SECTION 106 PERMITS |
20 | SECTION 107 INSPECTIONS AND TESTING |
23 | SECTION 108 VIOLATIONS |
25 | SECTION 109 MEANS OF APPEAL |
27 | SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
28 | BIBLIOGRAPHY |
30 | CHAPTER 2: DEFINITIONS GENERAL COMMENTS PURPOSE SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
35 | COMMENTARY FIGURE 202(1) BREATHING ZONE |
38 | COMMENTARY FIGURE 202(2) COMMERCIAL KITCHEN HOODS |
59 | COMMENTARY FIGURE 202(3) THERMAL RESISTANCE |
61 | BIBLIOGRAPHY |
62 | CHAPTER 3: GENERAL REGULATIONS GENERAL COMMENTS PURPOSE SECTION 301 GENERAL |
66 | COMMENTARY FIGURE 301.9 TYPICAL LABEL FOR A CATEGORY I GAS-FIRED FURNACE |
68 | SECTION 302 PROTECTION OF STRUCTURE |
69 | COMMENTARY FIGURE 302.3.1 HOLES AND NOTCHES IN WOOD JOISTS COMMENTARY FIGURE 302.3.2 NOTCHES IN WOOD STUDS |
70 | COMMENTARY FIGURE 302.3.3 BORED HOLES |
71 | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION |
73 | SECTION 304 INSTALLATION |
74 | COMMENTARY FIGURE 304.1 EXCERPTS FROM TYPICAL MANUFACTURER’S INSTALLATION MANUALS |
75 | COMMENTARY FIGURE 304.1—continued EXCERPTS FROM TYPICAL MANUFACTURER’S INSTALLATION MANUALS |
77 | COMMENTARY FIGURE 304.3 OIL-FIRED WATER HEATER INSTALLATION IN A HAZARDOUS LOCATION |
78 | COMMENTARY FIGURE 304.5.1.1 NATURAL VENTILATION OF SPACES CONTAINING HYDROGEN-GENERATING APPLIANCES |
80 | COMMENTARY FIGURE 304.6(1) APPLIANCE INSTALLATION IN A PUBLIC GARAGE |
81 | COMMENTARY FIGURE 304.6(2) APPLIANCE PROTECTION AGAINST MOTOR VEHICLE IMPACT |
82 | COMMENTARY FIGURE 304.7 SUSPENDED APPLIANCE IN RESIDENTIAL GARAGE |
84 | COMMENTARY FIGURE 304.11(1) GUARD REQUIREMENTS COMMENTARY FIGURE 304.11(2) FALL ARREST/RESTRAINT DEVICE |
85 | SECTION 305 PIPING SUPPORT COMMENTARY FIGURE 305.4 POINT OF SAG BETWEEN HANGERS TABLE 305.4 PIPING SUPPORT SPACING |
86 | COMMENTARY FIGURE 305.5 PIPE PROTECTION SECTION 306 ACCESS AND SERVICE SPACE |
88 | COMMENTARY FIGURE 306.3 REMOTE LOCATION REQUIREMENTS (ATTIC INSTALLATION) |
90 | COMMENTARY FIGURE 306.5(1) ACCESS HEIGHT ABOVE GRADE |
91 | COMMENTARY FIGURE 306.5(2) APPLIANCE ACCESS |
92 | COMMENTARY FIGURE 306.5.1 APPLIANCES AND EQUIPMENT ON SLOPED ROOFS SECTION 307 CONDENSATE DISPOSAL |
93 | TABLE 307.2.2 CONDENSATE DRAIN SIZING |
94 | COMMENTARY FIGURE 307.2.3(1) PRIMARY AND AUXILIARY DRAIN PAN FLOAT SWITCH COMMENTARY FIGURE 307.2.3(2) CONDENSATE OVERFLOW SWITCH COMMENTARY FIGURE 307.2.3(3) IN-LINE CONDENSATE OVERFLOW SWITCH |
95 | COMMENTARY FIGURE 307.2.3.2 APPLIANCES, EQUIPMENT AND INSULATION IN PANS |
96 | COMMENTARY FIGURE 307.2.5 DRAIN LINE ACCESS MEANS COMMENTARY FIGURE 307.3 CONDENSATE PUMP SECTION 308 CLEARANCE REDUCTION |
97 | COMMENTARY FIGURE 308.1(1) CLEARANCE TO COMBUSTIBLES—EXAMPLES OF HOW TO MEASURE |
98 | COMMENTARY FIGURE 308.1(2) REDUCED CLEARANCE FOR 3 1/2-INCH BRICK WALL COMMENTARY FIGURE 308.1(3) VENTILATED MASONRY CLEARANCE REDUCTION SYSTEM |
99 | COMMENTARY FIGURE 308.2 TYPICAL CLEARANCES FOR A RADIANT-TYPE WOOD-BURNING STOVE |
100 | COMMENTARY FIGURE 308.3 REDUCED CLEARANCE TO COMBUSTIBLES |
101 | TABLE 308.4.2 CLEARANCE REDUCTION METHODSb |
102 | COMMENTARY FIGURE 308.4.2(1) REDUCED CLEARANCE TO COMBUSTIBLES COMMENTARY FIGURE 308.4.2(2) CLEARANCE TO COMBUSTIBLES |
103 | COMMENTARY FIGURE 308.4.2(3) CLEARANCE TO COMBUSTIBLES COMMENTARY FIGURE 308.4.2(4) CLEARANCE TO COMBUSTIBLES |
104 | SECTION 309 TEMPERATURE CONTROL SECTION 310 EXPLOSION CONTROL |
105 | SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS BIBLIOGRAPHY |
106 | CHAPTER 4: VENTILATION GENERAL COMMENTS PURPOSE |
107 | SECTION 401 GENERAL |
109 | COMMENTARY FIGURE 401.4(1) INTAKE OPENING |
110 | TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS COMMENTARY FIGURE 401.4(2) INTAKE OPENING |
111 | SECTION 402 NATURAL VENTILATION COMMENTARY FIGURE 402.2 NATURAL LIGHT AND VENTILATION WINDOWS |
112 | COMMENTARY FIGURE 402.3 NATURAL VENTILATION FROM ADJOINING SPACE SECTION 403 MECHANICAL VENTILATION |
113 | COMMENTARY FIGURE 402.4 VENTILATION OPENINGS BELOW GRADE COMMENTARY FIGURE 403.1(1) AN ENERGY-CONSERVING ALTERNATIVE TO NATURAL VENTILATION |
114 | COMMENTARY FIGURE 403.1(2) TYPICAL HVAC SYSTEM |
119 | COMMENTARY FIGURE 403.3.1.1 OCCUPIED ZONE |
121 | COMMENTARY FIGURE 403.3.1.1(1) NAIL SALON STATIONS COMMENTARY FIGURE 403.3.1.1(2) MANICURE EXHAUST TABLE |
122 | TABLE 403.3.1.1 MINIMUM VENTILATION RATES |
123 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES |
124 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES |
125 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES EQUATION 4-1 |
126 | TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 |
127 | EQUATION 4-5 TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY EQUATION 4-6 EQUATION 4-7 |
128 | EQUATION 4-8 |
134 | EQUATION 4-9 |
136 | TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3, AND R-4 OCCUPANCIES COMMENTARY FIGURE 403.3.2.4 LABELING OF CONTROLS FOR WHOLE-HOUSE VENTILATION SYSTEM SECTION 404 ENCLOSED PARKING GARAGES |
137 | COMMENTARY FIGURE 403.3.2.5 EXHAUST EQUIPMENT MUST BE LISTED AND LABELED COMMENTARY FIGURE 404.1 MECHANICAL VENTILATION OF ENCLOSED PARKING GARAGES |
138 | SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES |
139 | BIBLIOGRAPHY |
140 | CHAPTER 5: EXHAUST SYSTEMS GENERAL COMMENTS PURPOSE SECTION 501 GENERAL |
143 | COMMENTARY FIGURE 501.3.1(1) SEPARATION REQUIREMENTS FOR ROOF EXHAUST (EXPLOSIVE OR FLAMMABLE) DUCT TERMINATIONS |
144 | COMMENTARY FIGURE 501.3.1(2) SEPARATION REQUIREMENTS FOR ROOF EXHAUST (EXPLOSIVE OR FLAMMABLE) DUCT TERMINATIONS |
146 | SECTION 502 REQUIRED SYSTEMS |
148 | EQUATION 5-1 |
164 | COMMENTARY FIGURE 502.14(1) OVERHEAD SOURCE CAPTURE SYSTEM COMMENTARY FIGURE 502.14(2) WALL-MOUNTED SOURCE CAPTURE SYSTEM |
166 | COMMENTARY FIGURE 502.20(1) PEDICURE STATION COMMENTARY FIGURE 502.20(2) MANICURE STATION |
167 | SECTION 503 MOTORS AND FANS |
168 | SECTION 504 CLOTHES DRYER EXHAUST |
169 | COMMENTARY FIGURE 504.2 NONCOMBUSTIBLE WALL RECEPTACLE FOR CLOTHES DRYER EXHAUST DUCT |
171 | COMMENTARY FIGURE 504.4 JOINTS IN DRYER EXHAUST DUCT MUST BE SEALED |
172 | COMMENTARY FIGURE 504.4.1 DRYER DUCT TERMINALS COMMENTARY FIGURE 504.5 DRYER EXHAUST DUCT POWER VENTILATOR |
173 | COMMENTARY FIGURE 504.7 DRYER EXHAUST DUCT PROTECTION |
174 | COMMENTARY FIGURE 504.8.2(1) DRYER EXHAUST DUCT INSTALLATION |
175 | COMMENTARY FIGURE 504.8.2(2) FRAMING CAVITIES MUST BE LARGE ENOUGH TO ALLOW A 4-INCH EXHAUST DUCT WITHOUT DEFORMATION |
176 | TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH COMMENTARY FIGURE 504.8.4.1 CLOTHES DRYER EXHAUST DUCT LENGTH |
177 | COMMENTARY FIGURE 504.8.5 EXAMPLE OF PERMANENT LABEL OF EQUIVALENT LENGTH |
178 | COMMENTARY FIGURE 504.8.6 DOMESTIC CLOTHES DRYER ROUGH-IN |
179 | COMMENTARY FIGURE 504.9 MULTIPLE DRYER EXHAUST SYSTEM |
181 | SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT |
183 | SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
185 | COMMENTARY FIGURE 506.3.1.1(1) TYPICAL FACTORY-BUILT GREASE DUCT LABEL COMMENTARY FIGURE 506.3.1.1(2) FACTORY-BUILT GREASE DUCTS |
186 | COMMENTARY FIGURE 506.3.1.2(1) PROHIBITED INSTALLATION OF FLEXIBLE AIR DUCT CONNECTING TO A MAKEUP AIR PLENUM ABOVE A TYPE I HOOD COMMENTARY FIGURE 506.3.1.2(2) BACKWALL MAKEUP AIR PLENUM |
187 | COMMENTARY FIGURE 506.3.2.1(1) TYPES OF DUCT JOINTS |
188 | COMMENTARY FIGURE 506.3.2.1(2) WELDED FLANGE JOINT |
189 | COMMENTARY FIGURE 506.3.2.2 DUCT-TO-HOOD JOINTS |
191 | COMMENTARY FIGURE 506.3.6 PROHIBITED INSTALLATION OF A GREASE DUCT |
192 | COMMENTARY FIGURE 506.3.7 PREVENTION OF GREASE ACCUMULATION |
193 | COMMENTARY FIGURE 506.3.7.1(1) GREASE COLLECTION RESERVOIR |
194 | COMMENTARY FIGURE 506.3.7.1(2) GREASE RESERVOIR |
195 | COMMENTARY FIGURE 506.3.8(1) GREASE DUCT CLEANOUT COMMENTARY FIGURE 506.3.8(2) GREASE DUCT CLEANOUT |
197 | COMMENTARY FIGURE 506.3.10 UNDERGROUND GREASE DUCT |
198 | COMMENTARY FIGURE 506.3.11 TERMINATION THROUGH EXTERIOR WALLS |
199 | COMMENTARY FIGURE 506.3.11.1(1) EXHAUST DUCT ENCLOSED BY A VERTICAL SHAFT |
200 | COMMENTARY FIGURE 506.3.11.1(2) EXHAUST DUCT PENETRATING A WALL |
201 | COMMENTARY FIGURE 506.3.11.2(1) FIELD-APPLIED GREASE DUCT ENCLOSURE |
202 | COMMENTARY FIGURE 506.3.11.2(2) PARTIAL APPLICATION OF FIELD-APPLIED GREASE DUCT ENCLOSURE (PROHIBITED) |
204 | COMMENTARY FIGURE 506.3.13.2 CLEARANCES TO OPENINGS FOR TYPE I EXHAUST DUCT TERMINATIONS |
205 | COMMENTARY FIGURE 506.5.1(1) ROOF-MOUNTED EXHAUST FAN FOR A TYPE I HOOD (Notice that the duct does not extend 18 inches above the roof surface) |
206 | COMMENTARY FIGURE 506.5.1(2) INLINE EXHAUST FAN FOR A TYPE I HOOD COMMENTARY FIGURE 506.5.1.2 AN INLINE FAN MUST BE LOCATED IN A ROOM OR SPACE HAVING THE SAME FIRE-RESISTANCE RATING AS THE GREASE-DUCT ENCLOSURE |
208 | COMMENTARY FIGURE 506.5.2 POLLUTION-CONTROL UNIT COMMENTARY FIGURE 506.5.3(1) KITCHEN EXHAUST FAN MOUNTED 18 INCHES ABOVE THE ROOF SURFACE WITH VENTS FOR THE SHAFT |
209 | COMMENTARY FIGURE 506.5.3(2) RESTRAINT CABLE FOR HINGED UPBLAST EXHAUST FAN COMMENTARY FIGURE 506.5.6 EXHAUST OUTLET TERMINATION |
210 | SECTION 507 COMMERCIAL KITCHEN HOODS |
211 | COMMENTARY FIGURE 507.1(1) TYPICAL LABEL FOR A TYPE I HOOD |
212 | COMMENTARY FIGURE 507.1(2) ELECTRIC DEEP FAT FRYER WITH RECIRCULATING HOOD COMMENTARY FIGURE 507.1(3) ELECTRIC GRIDDLE WITH RECIRCULATING HOOD |
213 | COMMENTARY FIGURE 507.1(4) HIBACHI TABLE WITH INTEGRAL DOWN-DRAFT EXHAUST SYSTEM COMMENTARY FIGURE 507.1(5) DOWN-DRAFT EXHAUST SYSTEM |
214 | COMMENTARY FIGURE 507.1.1 COMMERCIAL KITCHEN EXHAUST HOOD SYSTEMS SHALL OPERATE DURING THE COOKING OPERATION |
216 | COMMENTARY FIGURE 507.1.1.1 SENSORS FOR AUTOMATIC OPERATION MUST BE LOCATED IN EACH HOOD SERVED BY A COMMON EXHAUST SYSTEM |
217 | COMMENTARY FIGURE 507.1.3 WATER HEATER NEXT TO A TYPE I HOOD |
222 | COMMENTARY FIGURE 507.2.6 TYPE I HOOD THAT MAY BE LISTED FOR REDUCED CLEARANCE COMMENTARY FIGURE 507.2.7 GREASE DUCT ENCLOSURE SYSTEM USED ON THE TOP OF A TYPE I HOOD (Prohibited) |
223 | TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE COMMENTARY FIGURE 507.2.8 APPLIANCE VENTING UNDERNEATH A TYPE I HOOD |
225 | COMMENTARY FIGURE 507.2.8.2(1) MINIMUM ANGLE OF GREASE FILTERS COMMENTARY FIGURE 507.2.8.2(2) GREASE FILTER MOUNTED AT MINIMUM ANGLE OF 45 DEGREES COMMENTARY FIGURE 507.2.9 GREASE GUTTER WITH RESERVOIR |
226 | COMMENTARY FIGURE 507.3 TYPE II HOOD ABOVE A DISHWASHER |
227 | COMMENTARY FIGURE 507.4.1(1) CANOPY HOOD—ELEVATION COMMENTARY FIGURE 507.4.1(2) WALL-TYPE CANOPY HOOD |
228 | COMMENTARY FIGURE 507.4.1(3) WALL-TYPE CANOPY HOOD WITH MAKEUP AIR COMMENTARY FIGURE 507.4.1(4) ISLAND-TYPE CANOPY HOOD |
229 | COMMENTARY FIGURE 507.4.1(5) BACK-TO-BACK (DOUBLE ISLAND) TYPE CANOPY HOOD COMMENTARY FIGURE 507.4.1(6) CANOPY HOOD WITH SIDE PANELS—SIDE VIEW COMMENTARY FIGURE 507.4.1(7) CANOPY HOOD WITH SIDE PANELS—ELEVATION |
230 | COMMENTARY FIGURE 507.4.2 NONCANOPY-TYPE HOOD (LOW-WALL OR BACKSHELF) COMMENTARY FIGURE 507.5(1) CANOPY HOOD SERVING MULTIPLE APPLIANCES |
231 | COMMENTARY FIGURE 507.5(2) BACKSHELF/PASS-OVER HOOD COMMENTARY FIGURE 507.5(3) BACKSHELF HOOD WITH ONE SIDE PANEL |
232 | COMMENTARY FIGURE 507.5.1 HOOD APPLIANCE PLAN VIEW |
234 | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR |
235 | COMMENTARY FIGURE 508.1(1) MAKEUP AIR |
236 | COMMENTARY FIGURE 508.1(2) MAKEUP AIR |
237 | COMMENTARY FIGURE 508.1(3) MAKEUP AIR SUPPLIED FROM FACE OF HOOD COMMENTARY FIGURE 508.1(4) MAKEUP AIR SUPPLIED TO HOOD (Short-circuit hood) |
238 | COMMENTARY FIGURE 508.1.2 OUTDOOR AIR BALANCE REQUIRED |
239 | SECTION 509 FIRE SUPPRESSION SYSTEMS COMMENTARY FIGURE 509.1 SUPPRESSION SYSTEM FOR COMMERCIAL-TYPE COOKING EQUIPMENT |
240 | SECTION 510 HAZARDOUS EXHAUST SYSTEMS |
244 | COMMENTARY FIGURE 510.5 MANIFOLDED HAZARDOUS EXHAUST DUCTS |
248 | TABLE 510.9 MINIMUM DUCT THICKNESS |
249 | COMMENTARY FIGURE 510.9.1 DUCT JOINTS TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES |
250 | SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS |
252 | TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS |
253 | SECTION 513 SMOKE CONTROL SYSTEMS |
256 | COMMENTARY FIGURE 513.4.1 STACK EFFECT |
261 | EQUATION 5-2 |
262 | COMMENTARY FIGURE 513.8(1) SMOKE LAYER INTERFACE |
264 | COMMENTARY FIGURE 513.8(2) AXISYMMETRICAL PLUME COMMENTARY FIGURE 513.8(3) BALCONY SPILL PLUME |
265 | COMMENTARY FIGURE 513.8(4) WINDOW PLUME COMMENTARY FIGURE 513.8(5) PLUGHOLING |
266 | COMMENTARY FIGURE 513.8.1(1) EXAMPLE, CRITICAL LEVEL OF SMOKE |
267 | COMMENTARY FIGURE 513.8.1(2) SMOKE LAYER |
269 | EQUATION 5-3 |
274 | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS |
276 | BIBLIOGRAPHY |
278 | CHAPTER 6: DUCT SYSTEMS GENERAL COMMENTS PURPOSE SECTION 601 GENERAL |
279 | COMMENTARY FIGURE 601.2(1) POSITIVE PRESSURE IN CORRIDOR PROVIDES MAKEUP AIR FOR SMALL EXHAUST FANS IN ADJACENT ROOMS |
280 | COMMENTARY FIGURE 601.2(2) ELEVATION VIEW FOR COMMENTARY FIGURE 601.2(1) |
281 | COMMENTARY FIGURE 601.2.1(1) CORRIDOR NOT FIRE-RESISTANCE RATED: SPACE ABOVE CEILING CAN BE USED AS A PLENUM |
282 | COMMENTARY FIGURE 601.2.1(2) SPACE ABOVE CEILING PROHIBITED FROM BEING USED AS A PLENUM COMMENTARY FIGURE 601.2.1(3) FIRE-RESISTANCE-RATED CEILING IN CORRIDOR: SPACE ABOVE CEILING CAN BE USED AS A PLENUM |
283 | COMMENTARY FIGURE 601.2.1(4) FIRE-RESISTANCE-RATED CORRIDOR WITH SUSPENDED NONRATED CEILING (Allowed if smoke detectors or sprinkler water flow detectors shut down the air handler) COMMENTARY FIGURE 601.2.1(5) SPACE ABOVE CEILING CAN BE USED AS A PLENUM IF PART OF AN ENGINEERED SMOKE CONTROL SYSTEM |
285 | SECTION 602 PLENUMS |
286 | COMMENTARY FIGURE 602.1(1) TYPICAL FLOOR/CEILING OR ROOF/CEILING RETURN AIR PLENUM COMMENTARY FIGURE 602.1(2) MECHANICAL ROOM USED AS RETURN AIR PLENUM |
287 | COMMENTARY FIGURE 602.1(3) MULTIPLE FIRE AREAS |
288 | COMMENTARY FIGURE 602.1(4) PROHIBITED RETURN AIR PLENUM APPLICATION |
289 | COMMENTARY FIGURE 602.2 PLENUM ENCLOSURE CONSTRUCTION |
292 | COMMENTARY FIGURE 602.2.1.5 DISCRETE PRODUCTS |
293 | COMMENTARY FIGURE 602.2.1.8 PIPE AND DUCT INSULATION FOR USE IN PLENUMS |
294 | COMMENTARY FIGURE 602.3(1) ACCEPTABLE STUD AND JOIST SPACE PLENUM INSTALLATION |
295 | COMMENTARY FIGURE 602.3(2) PROHIBITED STUD AND JOIST SPACE PLENUM INSTALLATION |
296 | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION |
297 | TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS |
299 | COMMENTARY FIGURE 603.5.2 NONMETALLIC PHENOLIC DUCTS |
300 | COMMENTARY FIGURE 603.6 TESTING OF FLEXIBLE AIR DUCTS AND CONNECTORS COMMENTARY FIGURE 603.6(1) FLEXIBLE CONNECTOR |
301 | COMMENTARY FIGURE 603.6(2) SAMPLE LABELS COMMENTARY FIGURE 603.6(3) SAMPLE LABELS |
302 | COMMENTARY FIGURE 603.6(4) INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
303 | COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
304 | COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
305 | COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
306 | COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
307 | COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
308 | COMMENTARYFIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS |
310 | COMMENTARY FIGURE 603.7 FURNACE DUCTS IN PRIVATE GARAGE |
311 | COMMENTARY FIGURE 603.8.2 UNDERGROUND DUCTS REQUIRE AN AIR LEAKAGE TEST BEFORE BURIAL |
312 | COMMENTARY FIGURE 603.9(1) TYPICAL HVAC METAL DUCT JOINTS REQUIRING SEALING |
313 | COMMENTARY FIGURE 603.9(2) BUTTON-LOCK AND SNAP-LOCK DUCT SEAMS |
315 | COMMENTARY FIGURE 603.17(1) AIR DISPERSION SYSTEM |
316 | COMMENTARY FIGURE 603.17(2) AIR DISPERSION SYSTEM SECTION 604 INSULATION |
317 | COMMENTARY FIGURE 604.3 DUCT COVERINGS AND LININGS |
319 | SECTION 605 AIR FILTERS |
320 | SECTION 606 SMOKE DETECTION SYSTEMS CONTROL |
321 | COMMENTARY FIGURE 606.2(1) AIR DISTRIBUTION SYSTEM SERVING NOT MORE THAN ONE SPACE |
322 | COMMENTARY FIGURE 606.2(2) AIR DISTRIBUTION SYSTEM SERVING MORE THAN ONE SPACE COMMENTARY FIGURE 606.2.1 SMOKE DETECTOR REQUIRED IN RETURN AIR SYSTEMS WITH FLOW GREATER THAN 2000 CFM |
324 | COMMENTARY FIGURE 606.2.2(1) LOCATION OF SMOKE DETECTORS IN COMMON RETURN AIR PLENUM COMMENTARY FIGURE 606.2.2(2) LOCATION OF SMOKE DETECTOR, EXCEPTION ITEM 1 |
325 | COMMENTARY FIGURE 606.2.2(3) TYPICAL FAN-POWERED TERMINAL UNIT COMMENTARY FIGURE 606.2.3 RETURN RISER |
327 | SECTION 607 DUCT AND TRANSFER OPENINGS COMMENTARY FIGURE 607.1(1) FIRE DAMPER COMMENTARY FIGURE 607.1(2) SMOKE DAMPER |
328 | COMMENTARY FIGURE 607.1(3) COMBINATION FIRE/SMOKE DAMPER COMMENTARY FIGURE 607.1(4) CEILING DAMPERS |
329 | COMMENTARY FIGURE 607.1(5) FIRE DAMPER IN WALL FRAME COMMENTARY FIGURE 607.1.1 HORIZONTAL DUCT BETWEEN TWO SHAFTS |
332 | [BF] TABLE 607.3.2.1 FIRE DAMPER RATING |
333 | COMMENTARY FIGURE 607.3.1(1) DYNAMIC RATED FIRE DAMPERS COMMENTARY FIGURE 607.3.1(2) CEILING RADIATION DAMPER IN A SUSPENDED CEILING |
335 | COMMENTARY FIGURE 607.3.3.2(1) LOCATION OF SMOKE DETECTORS IN DUCTS NEAR SMOKE/FIRE DAMPERS COMMENTARY FIGURE 607.3.3.2(2) LOCATION OF SMOKE DETECTORS NEAR SMOKE/FIRE DAMPERS IN AIR TRANSFER OPENING |
337 | COMMENTARY FIGURE 607.5 FIRE DAMPERS IN RATED WALL |
338 | COMMENTARY FIGURE 607.5.2 EXCEPTION 3: FIRE DAMPERS NOT REQUIRED WHERE DUCT IS 26-GAGE METAL AND CONTINUOUS |
339 | COMMENTARY FIGURE 607.5.3(1) FIRE DAMPERS NOT REQUIRED—EXCEPTION 1 |
340 | COMMENTARY FIGURE 607.5.3(2) FIRE DAMPERS NOT REQUIRED—EXCEPTION 3 |
342 | COMMENTARY FIGURE 607.5.5(1) ACCEPTABLE METHOD OF SUBDUCTING |
343 | COMMENTARY FIGURE 607.5.5.1(1) VERTICAL SHAFT—BOTTOM ENCLOSURE COMMENTARY FIGURE 607.5.5(2) PROHIBITED METHOD OF SUBDUCTING |
344 | COMMENTARY FIGURE 607.5.5.1(2) VERTICAL SHAFTS—BOTTOM ENCLOSURES ROOM COMMENTARY FIGURE 607.5.5.1(3) VERTICAL SHAFTS—BOTTOM ENCLOSURES WITH DRAFTSTOPPING |
345 | COMMENTARY FIGURE 607.5.5.1(4) VERTICAL SHAFTS—BOTTOM ENCLOSURES WITH FIRE SPRINKLERS COMMENTARY FIGURE 607.5.5.1(5) VERTICAL SHAFTS—BOTTOM ENCLOSURES |
346 | COMMENTARY FIGURE 607.5.7(1) SMOKE DAMPER REQUIRED IN AIR TRANSFER OPENING IN A SMOKE PARTITION COMMENTARY FIGURE 607.5.7(2) SMOKE DAMPER NOT REQUIRED WHERE AIR TRANSFER OPENING IS DUCTED |
347 | COMMENTARY FIGURE 607.5.7(3) SMOKE DAMPER NOT REQUIRED WHERE AIR TRANSFER OPENING IS DUCTED |
348 | COMMENTARY FIGURE 607.6.1(1) AIR DUCT PENETRATION OF A FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY COMMENTARY FIGURE 607.6.1(2) EXCEPTION: FIRE DAMPERS NOT REQUIRED AT EVERY FLOO |
350 | COMMENTARY FIGURE 607.6.3(1) DUCT PENETRATION OF NONFIRE-RESISTANCE-RATED ASSEMBLIES |
351 | COMMENTARY FIGURE 607.6.3(2) FIRE DAMPERS IN DUCTS PENETRATING NONFIRE-RESISTANCE-RATED ASSEMBLIES |
352 | BIBLIOGRAPHY |
354 | CHAPTER 7: COMBUSTION AIR GENERAL COMMENTS PURPOSE SECTION 701 GENERAL |
356 | COMMENTARY FIGURE 701.2 SIMPLIFIED EXAMPLE SCHEMATIC OF COMBUSTION AIR DAMPER/APPLIANCE INTERLOCK |
358 | CHAPTER 8: CHIMNEYS AND VENTS GENERAL COMMENTS PURPOSE SECTION 801 GENERAL |
362 | COMMENTARY FIGURE 801.18.1 APPLIANCE REPLACEMENTS AFFECTING EXISTING APPLIANCES |
364 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
366 | COMMENTARY FIGURE 802.9 SIDEWALL VENT TERMINAL SECTION 803 CONNECTORS |
368 | TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES |
369 | TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES |
370 | COMMENTARY FIGURE 803.10.3(1) CHIMNEY CONNECTOR INSTALLATION COMMENTARY FIGURE 803.10.3(2) CHIMNEY CONNECTOR INSTALLATION WITH THIMBLE |
371 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES |
372 | COMMENTARY FIGURE 803.10.4 CHIMNEY CONNECTOR SYSTEMS |
373 | SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS COMMENTARY FIGURE 804.1 DIRECT VENT APPLIANCE |
374 | COMMENTARY FIGURE 804.3(1) TYPICAL EXHAUSTER APPLICATIONS COMMENTARY FIGURE 804.3(2) TYPICAL POWER EXHAUSTER COMMENTARY FIGURE 804.3(3) EXHAUSTER AND CONTROL PACKAGE |
375 | COMMENTARY FIGURE 804.3(4) DRAFT INDUCER COMMENTARY FIGURE 804.3.1 DRAFT CONDITIONS WITH EQUIPMENT BURNER-INLET BLOWER |
376 | COMMENTARY FIGURE 804.3.2 SIMPLIFIED SAMPLE INTERLOCK CIRCUIT DIAGRAM FOR APPLIANCE SERVED BY POWER EXHAUSTER |
377 | COMMENTARY FIGURE 804.3.4(1) EXHAUSTER TERMINATIONS |
378 | COMMENTARY FIGURE 804.3.4(2) HORIZONTAL EXHAUSTER TERMINATION |
379 | COMMENTARY FIGURE 804.3.6 PROHIBITED APPLIANCE CONNECTION ON DISCHARGE SIDE OF POWER EXHAUSTER |
380 | SECTION 805 FACTORY-BUILT CHIMNEYS COMMENTARY FIGURE 805.1(1) SAMPLE FACTORY-BUILT CHIMNEY LABELS |
381 | COMMENTARY FIGURE 805.1(1)—continued SAMPLE FACTORY-BUILT CHIMNEY LABELS |
382 | COMMENTARY FIGURE 805.1(2) FACTORY-BUILT CHIMNEY COMPONENTS |
383 | COMMENTARY FIGURE 805.1(3) LOW-HEAT CHIMNEY TERMINATION COMMENTARY FIGURE 805.1(4) WIND EFFECT ON CHIMNEY TERMINATION |
385 | COMMENTARY FIGURE 805.3 CHIMNEY OFFSET LIMITATION COMMENTARY FIGURE 805.7 DECORATIVE SHROUDS |
386 | SECTION 806 METAL CHIMNEYS BIBLIOGRAPHY |
388 | CHAPTER 9: SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT GENERAL COMMENTS PURPOSE SECTION 901 GENERAL |
389 | SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES |
390 | COMMENTARY FIGURE 903.1(1) RECESSED WALL FACTORY-BUILT FIREPLACE COMMENTARY FIGURE 903.1(2) FREE-STANDING FACTORY-BUILT FIREPLACE |
392 | SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS |
393 | COMMENTARY FIGURE 905.1(1) TYPICAL ROOM HEATER SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES |
394 | COMMENTARY FIGURE 905.1(2) SAMPLE APPLIANCE LABEL |
395 | SECTION 907 INCINERATORS AND CREMATORIES SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS |
397 | SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES |
398 | SECTION 911 DUCT FURNACES SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS |
399 | SECTION 914 SAUNA HEATERS |
400 | SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES |
401 | SECTION 918 FORCED-AIR WARM-AIR FURNACES |
402 | SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS |
403 | SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS COMMENTARY FIGURE 924.1(1) TYPICAL FUEL CELL COMPONENTS |
404 | COMMENTARY FIGURE 924.1(2) GENERIC FUEL CELL SYSTEM SECTION 925 MASONRY HEATERS SECTION 926 GASEOUS HYDROGEN SYSTEMS SECTION 927 RADIANT HEATING SYSTEMS |
405 | SECTION 928 EVAPORATIVE COOLING EQUIPMENT |
406 | SECTION 929 HIGH-VOLUME LARGE-DIAMETER FANS COMMENTARY FIGURE 929.1 HIGH-VOLUME LARGE-DIAMETER FAN |
408 | CHAPTER 10: BOILERS, WATER HEATERS AND PRESSURE VESSELS GENERAL COMMENTS PURPOSE SECTION 1001 GENERAL |
409 | SECTION 1002 WATER HEATERS |
410 | SECTION 1003 PRESSURE VESSELS |
411 | SECTION 1004 BOILERS |
412 | COMMENTARY FIGURE 1004.1 STEAM AND HOT WATER BOILER LABEL |
413 | TABLE 1004.3.1 BOILER TOP CLEARANCES |
414 | SECTION 1005 BOILER CONNECTIONS |
415 | COMMENTARY FIGURE 1005.1(1) MULTIPLE INDEPENDENT HOT WATER BOILER INSTALLATION COMMENTARY FIGURE 1005.1(2) MULTIPLE MODULAR UNITS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS |
416 | COMMENTARY FIGURE 1005.2 TYPICAL REPLACEMENT (MAKEUP) WATER CONNECTIONS TO VARIOUS TYPES OF SYSTEMS |
417 | COMMENTARY FIGURE 1006.1 SAFETY VALVE FOR STEAM APPLICATIONS COMMENTARY FIGURE 1006.2 PRESSURE RELIEF VALVE FOR HOT WATER APPLICATIONS |
420 | COMMENTARY FIGURE 1006.7 COMPARISON OF FLAME DETECTION METHODS |
422 | SECTION 1007 BOILER LOW-WATER CUTOFF |
423 | COMMENTARY FIGURE 1007.1(1) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL WITH GAUGE GLASS AND TRI-COCKS FOR STEAM BOILER APPLICATION COMMENTARY FIGURE 1007.1(2) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION COMMENTARY FIGURE 1007.1(3) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION SECTION 1008 BOTTOM BLOWOFF VALVE |
424 | COMMENTARY FIGURE 1007.2 SIMPLIFIED SAMPLE WIRING SCHEMATIC FOR BASIC GAS-FIRED BOILER SECTION 1009 HOT WATER BOILER EXPANSION TANK |
425 | EQUATION 10-1 COMMENTARY FIGURE 1009.2(1) CLOSED-TYPE EXPANSION (COMPRESSION) TANK COMMENTARY FIGURE 1009.2(2) CLOSED-DIAPHRAGM-TYPE EXPANSION TANK |
426 | TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING COMMENTARY FIGURE 1009.3 OPEN-TYPE EXPANSION TANK |
427 | SECTION 1010 GAUGES |
428 | COMMENTARY FIGURE 1010.2 STEAM BOILER SIGHT GLASS SECTION 1011 TESTS |
429 | BIBLIOGRAPHY |
430 | CHAPTER 11: REFRIGERATION GENERAL COMMENTS |
431 | COMMENTARY FIGURE 11(1) OZONE DEPLETION PROCESS PURPOSE |
432 | COMMENTARY FIGURE 11(2) COMPRESSION CYCLE COMMENTARY FIGURE 11(3) REFRIGERATION SYSTEM EXAMPLE |
433 | SECTION 1101 GENERAL |
435 | COMMENTARY FIGURE 1101.10(1) INSTALLATION OF LOCKING CAPS FOR REFRIGERANT ACCESS PORT COMMENTARY FIGURE 1101.10(2) REFRIGERANT LOCKING CAPS AND TOOLS |
436 | COMMENTARY FIGURE 1101.10(3) REFRIGERANT LABELS FOR LOCKING CAPS COMMENTARY FIGURE 1101.10(4) SPECIAL REMOVAL TOOLS FOR REFRIGERANT LOCKING CAPS |
437 | SECTION 1102 SYSTEM REQUIREMENTS |
438 | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION |
439 | COMMENTARY FIGURE 1103.1 CLASSIFICATION OF REFRIGERANTS |
440 | TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
441 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
442 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
443 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
444 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
446 | COMMENTARY FIGURE 1103.3.1 REFRIGERATION SYSTEM CLASSIFICATION |
447 | SECTION 1104 SYSTEM APPLICATION REQUIREMENTS |
449 | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS |
450 | COMMENTARY FIGURE 1104.4.2 VOLUME CALCULATION WITH ZONE DAMPERS |
451 | SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS |
452 | EQUATION 11-1 |
454 | EQUATION 11-2 COMMENTARY FIGURE 1105.6.3 THE MINIMUM EMERGENCY VENTILATION RATE FOR AMMONIA IS 30 ACH PER IIAR2 |
456 | SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS |
457 | TABLE 1106.5.2 MINIMUM EXHAUST RATES |
458 | SECTION 1107 REFRIGERANT PIPING |
459 | COMMENTARY FIGURE 1107.2 REFRIGERANT PIPING IS NOT PERMITTED IN AN INTERIOR EXIT STAIRWAY, AMONG OTHER SPECIFIED LOCATIONS |
462 | SECTION 1108 FIELD TEST |
463 | [F] SECTION 1109 PERIODIC TESTING |
464 | CHAPTER 12: HYDRONIC PIPING GENERAL COMMENTS PURPOSE SECTION 1201 GENERAL |
465 | SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE |
469 | TABLE 1202.5 HYDRONIC PIPE FITTINGS |
470 | COMMENTARY FIGURE 1202.7(1) PACKED SLIP EXPANSION JOINT COMMENTARY FIGURE 1202.7(2) FLEXIBLE BALL JOINT COMMENTARY FIGURE 1202.7(3) METAL BELLOWS EXPANSION JOINT COMMENTARY FIGURE 1202.7(4) RUBBER EXPANSION JOINT COMMENTARY FIGURE 1202.7(5) FLEXIBLE HOSE |
471 | SECTION 1203 JOINTS AND CONNECTIONS |
472 | COMMENTARY FIGURE 1203.2 PREPARATION OF PIPE END |
474 | COMMENTARY FIGURE 1203.3.8.1(1) MECHANICALLY FORMED JOINT COMMENTARY FIGURE 1203.3.8.1(2) MECHANICALLY FORMED JOINT—DIMPLE LOCATION |
476 | COMMENTARY FIGURE 1203.8.1 PLASTIC HEAT-FUSED JOINT COMMENTARY FIGURE 1203.9.1 COMPRESSION-TYPE MECHANICAL JOINT |
477 | SECTION 1204 PIPE INSULATION |
478 | SECTION 1205 VALVES COMMENTARY FIGURE 1205.1.1 HEAT EXCHANGERS |
479 | COMMENTARY FIGURE 1205.1.2 CENTRAL SYSTEMS COMMENTARY FIGURE 1205.1.4 PRESSURE-REDUCING VALVES COMMENTARY FIGURE 1205.1.6 EXPANSION TANKS |
480 | SECTION 1206 PIPING INSTALLATION |
482 | COMMENTARY FIGURE 1206.9(1) PIPE EXPANSION COMMENTARY FIGURE 1206.9(2) “L” BEND |
483 | COMMENTARY FIGURE 1206.9(3) “Z” BEND COMMENTARY FIGURE 1206.9(4) “U” BEND SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS |
484 | SECTION 1209 EMBEDDED PIPING |
485 | SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS TABLE 1210.4 GROUND-SOURCE LOOP PIPE |
486 | TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS |
489 | BIBLIOGRAPHY |
490 | CHAPTER 13: FUEL OIL PIPING AND STORAGE GENERAL COMMENTS PURPOSE SECTION 1301 GENERAL |
491 | COMMENTARY FIGURE 1301.5(1) TYPICAL OIL STORAGE TANK BASEMENT INSTALLATION |
492 | COMMENTARY FIGURE 1301.5(2) BASEMENT INSTALLATION WITH TANK REMOVED SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING |
493 | SECTION 1303 JOINTS AND CONNECTIONS |
495 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
497 | SECTION 1306 OIL GAUGING |
498 | SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING BIBLIOGRAPHY |
500 | CHAPTER 14: SOLAR THERMAL SYSTEMS GENERAL COMMENTS COMMENTARY FIGURE 14(1) PASSIVE SOLAR SPACE HEATING COMMENTARY FIGURE 14(2) PASSIVE SOLAR HEATING AND COOLING APPLICATION |
501 | COMMENTARY FIGURE 14(3) ACTIVE SPACE AND DOMESTIC WATER HEATING SYSTEM COMMENTARY FIGURE 14(4) PASSIVE COLLECTION WITH MECHANICAL DISTRIBUTION PURPOSE |
502 | SECTION 1401 GENERAL COMMENTARY FIGURE 1401.3(1) GOSSELIN RATINGS |
503 | COMMENTARY FIGURE 1401.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLY NONTOXIC) GOSSELIN RATING OF 1 COMMENTARY FIGURE 1401.3(3) DOUBLE-WALL HEAT EXCHANGER COMMENTARY FIGURE 1401.4 SOLAR THERMAL SYSTEMS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC 900/SRCC 300 SECTION 1402 DESIGN AND INSTALLATION |
504 | COMMENTARY FIGURE 1401.4.1 SOLAR THERMAL COLLECTORS AND PANELS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC 901/SRCC 100 |
505 | COMMENTARY FIGURE 1402.3 SIMPLIFIED SCHEMATIC OF SOLAR WATER HEATING SYSTEM COMMENTARY FIGURE 1402.4 FLAT-PLATE SOLAR COLLECTORS |
507 | COMMENTARY FIGURE 1402.5.3 SIMPLIFIED SCHEMATIC OF DRAINBACK FREEZE PROTECTION SYSTEM COMMENTARY FIGURE 1402.7.1 DOUBLE ENVELOPE PASSIVE SOLAR HEATING |
510 | SECTION 1403 HEAT TRANSFER FLUIDS |
511 | SECTION 1404 LABELING BIBLIOGRAPHY |
512 | CHAPTER 15: REFERENCED STANDARDS GENERAL COMMENTS PURPOSE |
513 | COMMENTARY FIGURE 15 REFERENCED STANDARDS |
514 | ACCA AHRI AMCA ANSI ASHRAE |
515 | ASME ASSE |
516 | ASSE ASTM |
519 | AWS AWWA |
520 | CPSC CSA DOL FDA |
521 | FS ICC IIAR |
522 | MSS NAIMA NBBI NFPA |
523 | NSF SMACNA UL |
528 | APPENDIX A: CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS |
529 | FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS |
530 | APPENDIX B: RECOMMENDED PERMIT FEE SCHEDULE B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS B102 FEE FOR REINSPECTION B103 TEMPORARY OPERATION INSPECTION FEE B104 SELF-CONTAINED UNITS LESS THAN 2 TONS |
532 | INDEX |
538 | ICC EVALUATION SERVICE |
539 | ICC premiumACCESS |
540 | ICC LEARNING CENTER |
541 | ICC ASSESSMENT CENTER |