ICC IMC Commentary 2018 1stPrint

$80.71

International Mechanical Code and Commentary

Published By Publication Date Number of Pages
ICC 2018
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This comprehensive publication provides a convenient reference for regulations in the 2018 International Mechanical Code® (IMC®).

PDF Catalog

PDF Pages PDF Title
1 2018 IMC® CODE AND COMMENTARY
2 2018 IMC® CODE AND COMMENTARY TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 CHAPTER 1: SCOPE AND ADMINISTRATION
GENERAL COMMENTS
PURPOSE
9 PART 1–SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
12 PART 2–ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION
13 SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
14 SECTION 105 APPROVAL
16 SECTION 106 PERMITS
20 SECTION 107 INSPECTIONS AND TESTING
23 SECTION 108 VIOLATIONS
25 SECTION 109 MEANS OF APPEAL
27 SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES
28 BIBLIOGRAPHY
30 CHAPTER 2: DEFINITIONS
GENERAL COMMENTS
PURPOSE
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
35 COMMENTARY FIGURE 202(1) BREATHING ZONE
38 COMMENTARY FIGURE 202(2) COMMERCIAL KITCHEN HOODS
59 COMMENTARY FIGURE 202(3) THERMAL RESISTANCE
61 BIBLIOGRAPHY
62 CHAPTER 3: GENERAL REGULATIONS
GENERAL COMMENTS
PURPOSE
SECTION 301 GENERAL
66 COMMENTARY FIGURE 301.9 TYPICAL LABEL FOR A CATEGORY I GAS-FIRED FURNACE
68 SECTION 302 PROTECTION OF STRUCTURE
69 COMMENTARY FIGURE 302.3.1 HOLES AND NOTCHES IN WOOD JOISTS
COMMENTARY FIGURE 302.3.2 NOTCHES IN WOOD STUDS
70 COMMENTARY FIGURE 302.3.3 BORED HOLES
71 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
73 SECTION 304 INSTALLATION
74 COMMENTARY FIGURE 304.1 EXCERPTS FROM TYPICAL MANUFACTURER’S INSTALLATION MANUALS
75 COMMENTARY FIGURE 304.1—continued EXCERPTS FROM TYPICAL MANUFACTURER’S INSTALLATION MANUALS
77 COMMENTARY FIGURE 304.3 OIL-FIRED WATER HEATER INSTALLATION IN A HAZARDOUS LOCATION
78 COMMENTARY FIGURE 304.5.1.1 NATURAL VENTILATION OF SPACES CONTAINING HYDROGEN-GENERATING APPLIANCES
80 COMMENTARY FIGURE 304.6(1) APPLIANCE INSTALLATION IN A PUBLIC GARAGE
81 COMMENTARY FIGURE 304.6(2) APPLIANCE PROTECTION AGAINST MOTOR VEHICLE IMPACT
82 COMMENTARY FIGURE 304.7 SUSPENDED APPLIANCE IN RESIDENTIAL GARAGE
84 COMMENTARY FIGURE 304.11(1) GUARD REQUIREMENTS
COMMENTARY FIGURE 304.11(2) FALL ARREST/RESTRAINT DEVICE
85 SECTION 305 PIPING SUPPORT
COMMENTARY FIGURE 305.4 POINT OF SAG BETWEEN HANGERS
TABLE 305.4 PIPING SUPPORT SPACING
86 COMMENTARY FIGURE 305.5 PIPE PROTECTION
SECTION 306 ACCESS AND SERVICE SPACE
88 COMMENTARY FIGURE 306.3 REMOTE LOCATION REQUIREMENTS (ATTIC INSTALLATION)
90 COMMENTARY FIGURE 306.5(1) ACCESS HEIGHT ABOVE GRADE
91 COMMENTARY FIGURE 306.5(2) APPLIANCE ACCESS
92 COMMENTARY FIGURE 306.5.1 APPLIANCES AND EQUIPMENT ON SLOPED ROOFS
SECTION 307 CONDENSATE DISPOSAL
93 TABLE 307.2.2 CONDENSATE DRAIN SIZING
94 COMMENTARY FIGURE 307.2.3(1) PRIMARY AND AUXILIARY DRAIN PAN FLOAT SWITCH
COMMENTARY FIGURE 307.2.3(2) CONDENSATE OVERFLOW SWITCH
COMMENTARY FIGURE 307.2.3(3) IN-LINE CONDENSATE OVERFLOW SWITCH
95 COMMENTARY FIGURE 307.2.3.2 APPLIANCES, EQUIPMENT AND INSULATION IN PANS
96 COMMENTARY FIGURE 307.2.5 DRAIN LINE ACCESS MEANS
COMMENTARY FIGURE 307.3 CONDENSATE PUMP
SECTION 308 CLEARANCE REDUCTION
97 COMMENTARY FIGURE 308.1(1) CLEARANCE TO COMBUSTIBLES—EXAMPLES OF HOW TO MEASURE
98 COMMENTARY FIGURE 308.1(2) REDUCED CLEARANCE FOR 3 1/2-INCH BRICK WALL
COMMENTARY FIGURE 308.1(3) VENTILATED MASONRY CLEARANCE REDUCTION SYSTEM
99 COMMENTARY FIGURE 308.2 TYPICAL CLEARANCES FOR A RADIANT-TYPE WOOD-BURNING STOVE
100 COMMENTARY FIGURE 308.3 REDUCED CLEARANCE TO COMBUSTIBLES
101 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
102 COMMENTARY FIGURE 308.4.2(1) REDUCED CLEARANCE TO COMBUSTIBLES
COMMENTARY FIGURE 308.4.2(2) CLEARANCE TO COMBUSTIBLES
103 COMMENTARY FIGURE 308.4.2(3) CLEARANCE TO COMBUSTIBLES
COMMENTARY FIGURE 308.4.2(4) CLEARANCE TO COMBUSTIBLES
104 SECTION 309 TEMPERATURE CONTROL
SECTION 310 EXPLOSION CONTROL
105 SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
BIBLIOGRAPHY
106 CHAPTER 4: VENTILATION
GENERAL COMMENTS
PURPOSE
107 SECTION 401 GENERAL
109 COMMENTARY FIGURE 401.4(1) INTAKE OPENING
110 TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
COMMENTARY FIGURE 401.4(2) INTAKE OPENING
111 SECTION 402 NATURAL VENTILATION
COMMENTARY FIGURE 402.2 NATURAL LIGHT AND VENTILATION WINDOWS
112 COMMENTARY FIGURE 402.3 NATURAL VENTILATION FROM ADJOINING SPACE
SECTION 403 MECHANICAL VENTILATION
113 COMMENTARY FIGURE 402.4 VENTILATION OPENINGS BELOW GRADE
COMMENTARY FIGURE 403.1(1) AN ENERGY-CONSERVING ALTERNATIVE TO NATURAL VENTILATION
114 COMMENTARY FIGURE 403.1(2) TYPICAL HVAC SYSTEM
119 COMMENTARY FIGURE 403.3.1.1 OCCUPIED ZONE
121 COMMENTARY FIGURE 403.3.1.1(1) NAIL SALON STATIONS
COMMENTARY FIGURE 403.3.1.1(2) MANICURE EXHAUST TABLE
122 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
123 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
124 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
125 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
EQUATION 4-1
126 TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
127 EQUATION 4-5
TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
128 EQUATION 4-8
134 EQUATION 4-9
136 TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3, AND R-4 OCCUPANCIES
COMMENTARY FIGURE 403.3.2.4 LABELING OF CONTROLS FOR WHOLE-HOUSE VENTILATION SYSTEM
SECTION 404 ENCLOSED PARKING GARAGES
137 COMMENTARY FIGURE 403.3.2.5 EXHAUST EQUIPMENT MUST BE LISTED AND LABELED
COMMENTARY FIGURE 404.1 MECHANICAL VENTILATION OF ENCLOSED PARKING GARAGES
138 SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
139 BIBLIOGRAPHY
140 CHAPTER 5: EXHAUST SYSTEMS
GENERAL COMMENTS
PURPOSE
SECTION 501 GENERAL
143 COMMENTARY FIGURE 501.3.1(1) SEPARATION REQUIREMENTS FOR ROOF EXHAUST (EXPLOSIVE OR FLAMMABLE) DUCT TERMINATIONS
144 COMMENTARY FIGURE 501.3.1(2) SEPARATION REQUIREMENTS FOR ROOF EXHAUST (EXPLOSIVE OR FLAMMABLE) DUCT TERMINATIONS
146 SECTION 502 REQUIRED SYSTEMS
148 EQUATION 5-1
164 COMMENTARY FIGURE 502.14(1) OVERHEAD SOURCE CAPTURE SYSTEM
COMMENTARY FIGURE 502.14(2) WALL-MOUNTED SOURCE CAPTURE SYSTEM
166 COMMENTARY FIGURE 502.20(1) PEDICURE STATION
COMMENTARY FIGURE 502.20(2) MANICURE STATION
167 SECTION 503 MOTORS AND FANS
168 SECTION 504 CLOTHES DRYER EXHAUST
169 COMMENTARY FIGURE 504.2 NONCOMBUSTIBLE WALL RECEPTACLE FOR CLOTHES DRYER EXHAUST DUCT
171 COMMENTARY FIGURE 504.4 JOINTS IN DRYER EXHAUST DUCT MUST BE SEALED
172 COMMENTARY FIGURE 504.4.1 DRYER DUCT TERMINALS
COMMENTARY FIGURE 504.5 DRYER EXHAUST DUCT POWER VENTILATOR
173 COMMENTARY FIGURE 504.7 DRYER EXHAUST DUCT PROTECTION
174 COMMENTARY FIGURE 504.8.2(1) DRYER EXHAUST DUCT INSTALLATION
175 COMMENTARY FIGURE 504.8.2(2) FRAMING CAVITIES MUST BE LARGE ENOUGH TO ALLOW A 4-INCH EXHAUST DUCT WITHOUT DEFORMATION
176 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
COMMENTARY FIGURE 504.8.4.1 CLOTHES DRYER EXHAUST DUCT LENGTH
177 COMMENTARY FIGURE 504.8.5 EXAMPLE OF PERMANENT LABEL OF EQUIVALENT LENGTH
178 COMMENTARY FIGURE 504.8.6 DOMESTIC CLOTHES DRYER ROUGH-IN
179 COMMENTARY FIGURE 504.9 MULTIPLE DRYER EXHAUST SYSTEM
181 SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT
183 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
185 COMMENTARY FIGURE 506.3.1.1(1) TYPICAL FACTORY-BUILT GREASE DUCT LABEL
COMMENTARY FIGURE 506.3.1.1(2) FACTORY-BUILT GREASE DUCTS
186 COMMENTARY FIGURE 506.3.1.2(1) PROHIBITED INSTALLATION OF FLEXIBLE AIR DUCT CONNECTING TO A MAKEUP AIR PLENUM ABOVE A TYPE I HOOD
COMMENTARY FIGURE 506.3.1.2(2) BACKWALL MAKEUP AIR PLENUM
187 COMMENTARY FIGURE 506.3.2.1(1) TYPES OF DUCT JOINTS
188 COMMENTARY FIGURE 506.3.2.1(2) WELDED FLANGE JOINT
189 COMMENTARY FIGURE 506.3.2.2 DUCT-TO-HOOD JOINTS
191 COMMENTARY FIGURE 506.3.6 PROHIBITED INSTALLATION OF A GREASE DUCT
192 COMMENTARY FIGURE 506.3.7 PREVENTION OF GREASE ACCUMULATION
193 COMMENTARY FIGURE 506.3.7.1(1) GREASE COLLECTION RESERVOIR
194 COMMENTARY FIGURE 506.3.7.1(2) GREASE RESERVOIR
195 COMMENTARY FIGURE 506.3.8(1) GREASE DUCT CLEANOUT
COMMENTARY FIGURE 506.3.8(2) GREASE DUCT CLEANOUT
197 COMMENTARY FIGURE 506.3.10 UNDERGROUND GREASE DUCT
198 COMMENTARY FIGURE 506.3.11 TERMINATION THROUGH EXTERIOR WALLS
199 COMMENTARY FIGURE 506.3.11.1(1) EXHAUST DUCT ENCLOSED BY A VERTICAL SHAFT
200 COMMENTARY FIGURE 506.3.11.1(2) EXHAUST DUCT PENETRATING A WALL
201 COMMENTARY FIGURE 506.3.11.2(1) FIELD-APPLIED GREASE DUCT ENCLOSURE
202 COMMENTARY FIGURE 506.3.11.2(2) PARTIAL APPLICATION OF FIELD-APPLIED GREASE DUCT ENCLOSURE (PROHIBITED)
204 COMMENTARY FIGURE 506.3.13.2 CLEARANCES TO OPENINGS FOR TYPE I EXHAUST DUCT TERMINATIONS
205 COMMENTARY FIGURE 506.5.1(1) ROOF-MOUNTED EXHAUST FAN FOR A TYPE I HOOD (Notice that the duct does not extend
18 inches above the roof surface)
206 COMMENTARY FIGURE 506.5.1(2) INLINE EXHAUST FAN FOR A TYPE I HOOD
COMMENTARY FIGURE 506.5.1.2 AN INLINE FAN MUST BE LOCATED IN A ROOM OR SPACE HAVING THE SAME FIRE-RESISTANCE RATING AS THE GREASE-DUCT ENCLOSURE
208 COMMENTARY FIGURE 506.5.2 POLLUTION-CONTROL UNIT
COMMENTARY FIGURE 506.5.3(1) KITCHEN EXHAUST FAN MOUNTED 18 INCHES ABOVE THE ROOF SURFACE WITH VENTS FOR THE SHAFT
209 COMMENTARY FIGURE 506.5.3(2) RESTRAINT CABLE FOR HINGED UPBLAST EXHAUST FAN
COMMENTARY FIGURE 506.5.6 EXHAUST OUTLET TERMINATION
210 SECTION 507 COMMERCIAL KITCHEN HOODS
211 COMMENTARY FIGURE 507.1(1) TYPICAL LABEL FOR A TYPE I HOOD
212 COMMENTARY FIGURE 507.1(2) ELECTRIC DEEP FAT FRYER WITH RECIRCULATING HOOD
COMMENTARY FIGURE 507.1(3) ELECTRIC GRIDDLE WITH RECIRCULATING HOOD
213 COMMENTARY FIGURE 507.1(4) HIBACHI TABLE WITH INTEGRAL DOWN-DRAFT EXHAUST SYSTEM
COMMENTARY FIGURE 507.1(5) DOWN-DRAFT EXHAUST SYSTEM
214 COMMENTARY FIGURE 507.1.1 COMMERCIAL KITCHEN EXHAUST HOOD SYSTEMS SHALL OPERATE DURING THE COOKING OPERATION
216 COMMENTARY FIGURE 507.1.1.1 SENSORS FOR AUTOMATIC OPERATION MUST BE LOCATED IN EACH HOOD SERVED BY A COMMON EXHAUST SYSTEM
217 COMMENTARY FIGURE 507.1.3 WATER HEATER NEXT TO A TYPE I HOOD
222 COMMENTARY FIGURE 507.2.6 TYPE I HOOD THAT MAY BE LISTED FOR REDUCED CLEARANCE
COMMENTARY FIGURE 507.2.7 GREASE DUCT ENCLOSURE SYSTEM USED ON THE TOP OF A TYPE I HOOD (Prohibited)
223 TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE
COMMENTARY FIGURE 507.2.8 APPLIANCE VENTING UNDERNEATH A TYPE I HOOD
225 COMMENTARY FIGURE 507.2.8.2(1) MINIMUM ANGLE OF GREASE FILTERS
COMMENTARY FIGURE 507.2.8.2(2) GREASE FILTER MOUNTED AT MINIMUM ANGLE OF 45 DEGREES
COMMENTARY FIGURE 507.2.9 GREASE GUTTER WITH RESERVOIR
226 COMMENTARY FIGURE 507.3 TYPE II HOOD ABOVE A DISHWASHER
227 COMMENTARY FIGURE 507.4.1(1) CANOPY HOOD—ELEVATION
COMMENTARY FIGURE 507.4.1(2) WALL-TYPE CANOPY HOOD
228 COMMENTARY FIGURE 507.4.1(3) WALL-TYPE CANOPY HOOD WITH MAKEUP AIR
COMMENTARY FIGURE 507.4.1(4) ISLAND-TYPE CANOPY HOOD
229 COMMENTARY FIGURE 507.4.1(5) BACK-TO-BACK (DOUBLE ISLAND) TYPE CANOPY HOOD
COMMENTARY FIGURE 507.4.1(6) CANOPY HOOD WITH SIDE PANELS—SIDE VIEW
COMMENTARY FIGURE 507.4.1(7) CANOPY HOOD WITH SIDE PANELS—ELEVATION
230 COMMENTARY FIGURE 507.4.2 NONCANOPY-TYPE HOOD (LOW-WALL OR BACKSHELF)
COMMENTARY FIGURE 507.5(1) CANOPY HOOD SERVING MULTIPLE APPLIANCES
231 COMMENTARY FIGURE 507.5(2) BACKSHELF/PASS-OVER HOOD
COMMENTARY FIGURE 507.5(3) BACKSHELF HOOD WITH ONE SIDE PANEL
232 COMMENTARY FIGURE 507.5.1 HOOD APPLIANCE PLAN VIEW
234 SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
235 COMMENTARY FIGURE 508.1(1) MAKEUP AIR
236 COMMENTARY FIGURE 508.1(2) MAKEUP AIR
237 COMMENTARY FIGURE 508.1(3) MAKEUP AIR SUPPLIED FROM FACE OF HOOD
COMMENTARY FIGURE 508.1(4) MAKEUP AIR SUPPLIED TO HOOD (Short-circuit hood)
238 COMMENTARY FIGURE 508.1.2 OUTDOOR AIR BALANCE REQUIRED
239 SECTION 509 FIRE SUPPRESSION SYSTEMS
COMMENTARY FIGURE 509.1 SUPPRESSION SYSTEM FOR COMMERCIAL-TYPE COOKING EQUIPMENT
240 SECTION 510 HAZARDOUS EXHAUST SYSTEMS
244 COMMENTARY FIGURE 510.5 MANIFOLDED HAZARDOUS EXHAUST DUCTS
248 TABLE 510.9 MINIMUM DUCT THICKNESS
249 COMMENTARY FIGURE 510.9.1 DUCT JOINTS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
250 SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
252 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
253 SECTION 513 SMOKE CONTROL SYSTEMS
256 COMMENTARY FIGURE 513.4.1 STACK EFFECT
261 EQUATION 5-2
262 COMMENTARY FIGURE 513.8(1) SMOKE LAYER INTERFACE
264 COMMENTARY FIGURE 513.8(2) AXISYMMETRICAL PLUME
COMMENTARY FIGURE 513.8(3) BALCONY SPILL PLUME
265 COMMENTARY FIGURE 513.8(4) WINDOW PLUME
COMMENTARY FIGURE 513.8(5) PLUGHOLING
266 COMMENTARY FIGURE 513.8.1(1) EXAMPLE, CRITICAL LEVEL OF SMOKE
267 COMMENTARY FIGURE 513.8.1(2) SMOKE LAYER
269 EQUATION 5-3
274 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
276 BIBLIOGRAPHY
278 CHAPTER 6: DUCT SYSTEMS
GENERAL COMMENTS
PURPOSE
SECTION 601 GENERAL
279 COMMENTARY FIGURE 601.2(1) POSITIVE PRESSURE IN CORRIDOR PROVIDES MAKEUP AIR FOR SMALL EXHAUST FANS IN ADJACENT ROOMS
280 COMMENTARY FIGURE 601.2(2) ELEVATION VIEW FOR COMMENTARY FIGURE 601.2(1)
281 COMMENTARY FIGURE 601.2.1(1) CORRIDOR NOT FIRE-RESISTANCE RATED: SPACE ABOVE CEILING CAN BE USED AS A PLENUM
282 COMMENTARY FIGURE 601.2.1(2) SPACE ABOVE CEILING PROHIBITED FROM BEING USED AS A PLENUM
COMMENTARY FIGURE 601.2.1(3) FIRE-RESISTANCE-RATED CEILING IN CORRIDOR: SPACE ABOVE CEILING CAN BE USED AS A PLENUM
283 COMMENTARY FIGURE 601.2.1(4) FIRE-RESISTANCE-RATED CORRIDOR WITH SUSPENDED NONRATED CEILING (Allowed if smoke detectors or sprinkler water flow detectors shut down the air handler)
COMMENTARY FIGURE 601.2.1(5) SPACE ABOVE CEILING CAN BE USED AS A PLENUM IF PART OF AN ENGINEERED SMOKE CONTROL SYSTEM
285 SECTION 602 PLENUMS
286 COMMENTARY FIGURE 602.1(1) TYPICAL FLOOR/CEILING OR ROOF/CEILING RETURN AIR PLENUM
COMMENTARY FIGURE 602.1(2) MECHANICAL ROOM USED AS RETURN AIR PLENUM
287 COMMENTARY FIGURE 602.1(3) MULTIPLE FIRE AREAS
288 COMMENTARY FIGURE 602.1(4) PROHIBITED RETURN AIR PLENUM APPLICATION
289 COMMENTARY FIGURE 602.2 PLENUM ENCLOSURE CONSTRUCTION
292 COMMENTARY FIGURE 602.2.1.5 DISCRETE PRODUCTS
293 COMMENTARY FIGURE 602.2.1.8 PIPE AND DUCT INSULATION FOR USE IN PLENUMS
294 COMMENTARY FIGURE 602.3(1) ACCEPTABLE STUD AND JOIST SPACE PLENUM INSTALLATION
295 COMMENTARY FIGURE 602.3(2) PROHIBITED STUD AND JOIST SPACE PLENUM INSTALLATION
296 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
297 TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITS
299 COMMENTARY FIGURE 603.5.2 NONMETALLIC PHENOLIC DUCTS
300 COMMENTARY FIGURE 603.6 TESTING OF FLEXIBLE AIR DUCTS AND CONNECTORS
COMMENTARY FIGURE 603.6(1) FLEXIBLE CONNECTOR
301 COMMENTARY FIGURE 603.6(2) SAMPLE LABELS
COMMENTARY FIGURE 603.6(3) SAMPLE LABELS
302 COMMENTARY FIGURE 603.6(4) INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
303 COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
304 COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
305 COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
306 COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
307 COMMENTARY FIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
308 COMMENTARYFIGURE 603.6(4)—continued INSTALLATION INSTRUCTIONS FOR FLEXIBLE AIR DUCTS AND AIR CONNECTORS
310 COMMENTARY FIGURE 603.7 FURNACE DUCTS IN PRIVATE GARAGE
311 COMMENTARY FIGURE 603.8.2 UNDERGROUND DUCTS REQUIRE AN AIR LEAKAGE TEST BEFORE BURIAL
312 COMMENTARY FIGURE 603.9(1) TYPICAL HVAC METAL DUCT JOINTS REQUIRING SEALING
313 COMMENTARY FIGURE 603.9(2) BUTTON-LOCK AND SNAP-LOCK DUCT SEAMS
315 COMMENTARY FIGURE 603.17(1) AIR DISPERSION SYSTEM
316 COMMENTARY FIGURE 603.17(2) AIR DISPERSION SYSTEM
SECTION 604 INSULATION
317 COMMENTARY FIGURE 604.3 DUCT COVERINGS AND LININGS
319 SECTION 605 AIR FILTERS
320 SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
321 COMMENTARY FIGURE 606.2(1) AIR DISTRIBUTION SYSTEM SERVING NOT MORE THAN ONE SPACE
322 COMMENTARY FIGURE 606.2(2) AIR DISTRIBUTION SYSTEM SERVING MORE THAN ONE SPACE
COMMENTARY FIGURE 606.2.1 SMOKE DETECTOR REQUIRED IN RETURN AIR SYSTEMS WITH FLOW GREATER THAN 2000 CFM
324 COMMENTARY FIGURE 606.2.2(1) LOCATION OF SMOKE DETECTORS IN COMMON RETURN AIR PLENUM
COMMENTARY FIGURE 606.2.2(2) LOCATION OF SMOKE DETECTOR, EXCEPTION ITEM 1
325 COMMENTARY FIGURE 606.2.2(3) TYPICAL FAN-POWERED TERMINAL UNIT
COMMENTARY FIGURE 606.2.3 RETURN RISER
327 SECTION 607 DUCT AND TRANSFER OPENINGS
COMMENTARY FIGURE 607.1(1) FIRE DAMPER
COMMENTARY FIGURE 607.1(2) SMOKE DAMPER
328 COMMENTARY FIGURE 607.1(3) COMBINATION FIRE/SMOKE DAMPER
COMMENTARY FIGURE 607.1(4) CEILING DAMPERS
329 COMMENTARY FIGURE 607.1(5) FIRE DAMPER IN WALL FRAME
COMMENTARY FIGURE 607.1.1 HORIZONTAL DUCT BETWEEN TWO SHAFTS
332 [BF] TABLE 607.3.2.1 FIRE DAMPER RATING
333 COMMENTARY FIGURE 607.3.1(1) DYNAMIC RATED FIRE DAMPERS
COMMENTARY FIGURE 607.3.1(2) CEILING RADIATION DAMPER IN A SUSPENDED CEILING
335 COMMENTARY FIGURE 607.3.3.2(1) LOCATION OF SMOKE DETECTORS IN DUCTS NEAR SMOKE/FIRE DAMPERS
COMMENTARY FIGURE 607.3.3.2(2) LOCATION OF SMOKE DETECTORS NEAR SMOKE/FIRE DAMPERS IN AIR TRANSFER OPENING
337 COMMENTARY FIGURE 607.5 FIRE DAMPERS IN RATED WALL
338 COMMENTARY FIGURE 607.5.2 EXCEPTION 3: FIRE DAMPERS NOT REQUIRED WHERE DUCT IS 26-GAGE METAL AND CONTINUOUS
339 COMMENTARY FIGURE 607.5.3(1) FIRE DAMPERS NOT REQUIRED—EXCEPTION 1
340 COMMENTARY FIGURE 607.5.3(2) FIRE DAMPERS NOT REQUIRED—EXCEPTION 3
342 COMMENTARY FIGURE 607.5.5(1) ACCEPTABLE METHOD OF SUBDUCTING
343 COMMENTARY FIGURE 607.5.5.1(1) VERTICAL SHAFT—BOTTOM ENCLOSURE
COMMENTARY FIGURE 607.5.5(2) PROHIBITED METHOD OF SUBDUCTING
344 COMMENTARY FIGURE 607.5.5.1(2) VERTICAL SHAFTS—BOTTOM ENCLOSURES ROOM
COMMENTARY FIGURE 607.5.5.1(3) VERTICAL SHAFTS—BOTTOM ENCLOSURES WITH DRAFTSTOPPING
345 COMMENTARY FIGURE 607.5.5.1(4) VERTICAL SHAFTS—BOTTOM ENCLOSURES WITH FIRE SPRINKLERS
COMMENTARY FIGURE 607.5.5.1(5) VERTICAL SHAFTS—BOTTOM ENCLOSURES
346 COMMENTARY FIGURE 607.5.7(1) SMOKE DAMPER REQUIRED IN AIR TRANSFER OPENING IN A SMOKE PARTITION
COMMENTARY FIGURE 607.5.7(2) SMOKE DAMPER NOT REQUIRED WHERE AIR TRANSFER OPENING IS DUCTED
347 COMMENTARY FIGURE 607.5.7(3) SMOKE DAMPER NOT REQUIRED WHERE AIR TRANSFER OPENING IS DUCTED
348 COMMENTARY FIGURE 607.6.1(1) AIR DUCT PENETRATION OF A FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
COMMENTARY FIGURE 607.6.1(2) EXCEPTION: FIRE DAMPERS NOT REQUIRED AT EVERY FLOO
350 COMMENTARY FIGURE 607.6.3(1) DUCT PENETRATION OF NONFIRE-RESISTANCE-RATED ASSEMBLIES
351 COMMENTARY FIGURE 607.6.3(2) FIRE DAMPERS IN DUCTS PENETRATING NONFIRE-RESISTANCE-RATED ASSEMBLIES
352 BIBLIOGRAPHY
354 CHAPTER 7: COMBUSTION AIR
GENERAL COMMENTS
PURPOSE
SECTION 701 GENERAL
356 COMMENTARY FIGURE 701.2 SIMPLIFIED EXAMPLE SCHEMATIC OF COMBUSTION AIR DAMPER/APPLIANCE INTERLOCK
358 CHAPTER 8: CHIMNEYS AND VENTS
GENERAL COMMENTS
PURPOSE
SECTION 801 GENERAL
362 COMMENTARY FIGURE 801.18.1 APPLIANCE REPLACEMENTS AFFECTING EXISTING APPLIANCES
364 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
366 COMMENTARY FIGURE 802.9 SIDEWALL VENT TERMINAL
SECTION 803 CONNECTORS
368 TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
369 TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
370 COMMENTARY FIGURE 803.10.3(1) CHIMNEY CONNECTOR INSTALLATION
COMMENTARY FIGURE 803.10.3(2) CHIMNEY CONNECTOR INSTALLATION WITH THIMBLE
371 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
372 COMMENTARY FIGURE 803.10.4 CHIMNEY CONNECTOR SYSTEMS
373 SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
COMMENTARY FIGURE 804.1 DIRECT VENT APPLIANCE
374 COMMENTARY FIGURE 804.3(1) TYPICAL EXHAUSTER APPLICATIONS
COMMENTARY FIGURE 804.3(2) TYPICAL POWER EXHAUSTER
COMMENTARY FIGURE 804.3(3) EXHAUSTER AND CONTROL PACKAGE
375 COMMENTARY FIGURE 804.3(4) DRAFT INDUCER
COMMENTARY FIGURE 804.3.1 DRAFT CONDITIONS WITH EQUIPMENT BURNER-INLET BLOWER
376 COMMENTARY FIGURE 804.3.2 SIMPLIFIED SAMPLE INTERLOCK CIRCUIT DIAGRAM FOR APPLIANCE SERVED BY POWER EXHAUSTER
377 COMMENTARY FIGURE 804.3.4(1) EXHAUSTER TERMINATIONS
378 COMMENTARY FIGURE 804.3.4(2) HORIZONTAL EXHAUSTER TERMINATION
379 COMMENTARY FIGURE 804.3.6 PROHIBITED APPLIANCE CONNECTION ON DISCHARGE SIDE OF POWER EXHAUSTER
380 SECTION 805 FACTORY-BUILT CHIMNEYS
COMMENTARY FIGURE 805.1(1) SAMPLE FACTORY-BUILT CHIMNEY LABELS
381 COMMENTARY FIGURE 805.1(1)—continued SAMPLE FACTORY-BUILT CHIMNEY LABELS
382 COMMENTARY FIGURE 805.1(2) FACTORY-BUILT CHIMNEY COMPONENTS
383 COMMENTARY FIGURE 805.1(3) LOW-HEAT CHIMNEY TERMINATION
COMMENTARY FIGURE 805.1(4) WIND EFFECT ON CHIMNEY TERMINATION
385 COMMENTARY FIGURE 805.3 CHIMNEY OFFSET LIMITATION
COMMENTARY FIGURE 805.7 DECORATIVE SHROUDS
386 SECTION 806 METAL CHIMNEYS
BIBLIOGRAPHY
388 CHAPTER 9: SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
GENERAL COMMENTS
PURPOSE
SECTION 901 GENERAL
389 SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
390 COMMENTARY FIGURE 903.1(1) RECESSED WALL FACTORY-BUILT FIREPLACE
COMMENTARY FIGURE 903.1(2) FREE-STANDING FACTORY-BUILT FIREPLACE
392 SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
393 COMMENTARY FIGURE 905.1(1) TYPICAL ROOM HEATER
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
394 COMMENTARY FIGURE 905.1(2) SAMPLE APPLIANCE LABEL
395 SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
397 SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
398 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
399 SECTION 914 SAUNA HEATERS
400 SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
401 SECTION 918 FORCED-AIR WARM-AIR FURNACES
402 SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
403 SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
COMMENTARY FIGURE 924.1(1) TYPICAL FUEL CELL COMPONENTS
404 COMMENTARY FIGURE 924.1(2) GENERIC FUEL CELL SYSTEM
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RADIANT HEATING SYSTEMS
405 SECTION 928 EVAPORATIVE COOLING EQUIPMENT
406 SECTION 929 HIGH-VOLUME LARGE-DIAMETER FANS
COMMENTARY FIGURE 929.1 HIGH-VOLUME LARGE-DIAMETER FAN
408 CHAPTER 10: BOILERS, WATER HEATERS AND PRESSURE VESSELS
GENERAL COMMENTS
PURPOSE
SECTION 1001 GENERAL
409 SECTION 1002 WATER HEATERS
410 SECTION 1003 PRESSURE VESSELS
411 SECTION 1004 BOILERS
412 COMMENTARY FIGURE 1004.1 STEAM AND HOT WATER BOILER LABEL
413 TABLE 1004.3.1 BOILER TOP CLEARANCES
414 SECTION 1005 BOILER CONNECTIONS
415 COMMENTARY FIGURE 1005.1(1) MULTIPLE INDEPENDENT HOT WATER BOILER INSTALLATION
COMMENTARY FIGURE 1005.1(2) MULTIPLE MODULAR UNITS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
416 COMMENTARY FIGURE 1005.2 TYPICAL REPLACEMENT (MAKEUP) WATER CONNECTIONS TO VARIOUS TYPES OF SYSTEMS
417 COMMENTARY FIGURE 1006.1 SAFETY VALVE FOR STEAM APPLICATIONS
COMMENTARY FIGURE 1006.2 PRESSURE RELIEF VALVE FOR HOT WATER APPLICATIONS
420 COMMENTARY FIGURE 1006.7 COMPARISON OF FLAME DETECTION METHODS
422 SECTION 1007 BOILER LOW-WATER CUTOFF
423 COMMENTARY FIGURE 1007.1(1) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL WITH GAUGE GLASS AND TRI-COCKS FOR STEAM BOILER APPLICATION
COMMENTARY FIGURE 1007.1(2) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
COMMENTARY FIGURE 1007.1(3) ELECTRONIC PROBE-TYPE LOW-WATER CUTOFF CONTROL FOR HOT WATER BOILER APPLICATION
SECTION 1008 BOTTOM BLOWOFF VALVE
424 COMMENTARY FIGURE 1007.2 SIMPLIFIED SAMPLE WIRING SCHEMATIC FOR BASIC GAS-FIRED BOILER
SECTION 1009 HOT WATER BOILER EXPANSION TANK
425 EQUATION 10-1
COMMENTARY FIGURE 1009.2(1) CLOSED-TYPE EXPANSION (COMPRESSION) TANK
COMMENTARY FIGURE 1009.2(2) CLOSED-DIAPHRAGM-TYPE EXPANSION TANK
426 TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
COMMENTARY FIGURE 1009.3 OPEN-TYPE EXPANSION TANK
427 SECTION 1010 GAUGES
428 COMMENTARY FIGURE 1010.2 STEAM BOILER SIGHT GLASS
SECTION 1011 TESTS
429 BIBLIOGRAPHY
430 CHAPTER 11: REFRIGERATION
GENERAL COMMENTS
431 COMMENTARY FIGURE 11(1) OZONE DEPLETION PROCESS
PURPOSE
432 COMMENTARY FIGURE 11(2) COMPRESSION CYCLE
COMMENTARY FIGURE 11(3) REFRIGERATION SYSTEM EXAMPLE
433 SECTION 1101 GENERAL
435 COMMENTARY FIGURE 1101.10(1) INSTALLATION OF LOCKING CAPS FOR REFRIGERANT ACCESS PORT
COMMENTARY FIGURE 1101.10(2) REFRIGERANT LOCKING CAPS AND TOOLS
436 COMMENTARY FIGURE 1101.10(3) REFRIGERANT LABELS FOR LOCKING CAPS
COMMENTARY FIGURE 1101.10(4) SPECIAL REMOVAL TOOLS FOR REFRIGERANT LOCKING CAPS
437 SECTION 1102 SYSTEM REQUIREMENTS
438 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
439 COMMENTARY FIGURE 1103.1 CLASSIFICATION OF REFRIGERANTS
440 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
441 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
442 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
443 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
444 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
446 COMMENTARY FIGURE 1103.3.1 REFRIGERATION SYSTEM CLASSIFICATION
447 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
449 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
450 COMMENTARY FIGURE 1104.4.2 VOLUME CALCULATION WITH ZONE DAMPERS
451 SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
452 EQUATION 11-1
454 EQUATION 11-2
COMMENTARY FIGURE 1105.6.3 THE MINIMUM EMERGENCY VENTILATION RATE FOR AMMONIA IS 30 ACH PER IIAR2
456 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
457 TABLE 1106.5.2 MINIMUM EXHAUST RATES
458 SECTION 1107 REFRIGERANT PIPING
459 COMMENTARY FIGURE 1107.2 REFRIGERANT PIPING IS NOT PERMITTED IN AN INTERIOR EXIT STAIRWAY, AMONG OTHER SPECIFIED LOCATIONS
462 SECTION 1108 FIELD TEST
463 [F] SECTION 1109 PERIODIC TESTING
464 CHAPTER 12: HYDRONIC PIPING
GENERAL COMMENTS
PURPOSE
SECTION 1201 GENERAL
465 SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
469 TABLE 1202.5 HYDRONIC PIPE FITTINGS
470 COMMENTARY FIGURE 1202.7(1) PACKED SLIP EXPANSION JOINT
COMMENTARY FIGURE 1202.7(2) FLEXIBLE BALL JOINT
COMMENTARY FIGURE 1202.7(3) METAL BELLOWS EXPANSION JOINT
COMMENTARY FIGURE 1202.7(4) RUBBER EXPANSION JOINT
COMMENTARY FIGURE 1202.7(5) FLEXIBLE HOSE
471 SECTION 1203 JOINTS AND CONNECTIONS
472 COMMENTARY FIGURE 1203.2 PREPARATION OF PIPE END
474 COMMENTARY FIGURE 1203.3.8.1(1) MECHANICALLY FORMED JOINT
COMMENTARY FIGURE 1203.3.8.1(2) MECHANICALLY FORMED JOINT—DIMPLE LOCATION
476 COMMENTARY FIGURE 1203.8.1 PLASTIC HEAT-FUSED JOINT
COMMENTARY FIGURE 1203.9.1 COMPRESSION-TYPE MECHANICAL JOINT
477 SECTION 1204 PIPE INSULATION
478 SECTION 1205 VALVES
COMMENTARY FIGURE 1205.1.1 HEAT EXCHANGERS
479 COMMENTARY FIGURE 1205.1.2 CENTRAL SYSTEMS
COMMENTARY FIGURE 1205.1.4 PRESSURE-REDUCING VALVES
COMMENTARY FIGURE 1205.1.6 EXPANSION TANKS
480 SECTION 1206 PIPING INSTALLATION
482 COMMENTARY FIGURE 1206.9(1) PIPE EXPANSION
COMMENTARY FIGURE 1206.9(2) “L” BEND
483 COMMENTARY FIGURE 1206.9(3) “Z” BEND
COMMENTARY FIGURE 1206.9(4) “U” BEND
SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
484 SECTION 1209 EMBEDDED PIPING
485 SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
TABLE 1210.4 GROUND-SOURCE LOOP PIPE
486 TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
489 BIBLIOGRAPHY
490 CHAPTER 13: FUEL OIL PIPING AND STORAGE
GENERAL COMMENTS
PURPOSE
SECTION 1301 GENERAL
491 COMMENTARY FIGURE 1301.5(1) TYPICAL OIL STORAGE TANK BASEMENT INSTALLATION
492 COMMENTARY FIGURE 1301.5(2) BASEMENT INSTALLATION WITH TANK REMOVED
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
493 SECTION 1303 JOINTS AND CONNECTIONS
495 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
497 SECTION 1306 OIL GAUGING
498 SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
BIBLIOGRAPHY
500 CHAPTER 14: SOLAR THERMAL SYSTEMS
GENERAL COMMENTS
COMMENTARY FIGURE 14(1) PASSIVE SOLAR SPACE HEATING
COMMENTARY FIGURE 14(2) PASSIVE SOLAR HEATING AND COOLING APPLICATION
501 COMMENTARY FIGURE 14(3) ACTIVE SPACE AND DOMESTIC WATER HEATING SYSTEM
COMMENTARY FIGURE 14(4) PASSIVE COLLECTION WITH MECHANICAL DISTRIBUTION
PURPOSE
502 SECTION 1401 GENERAL
COMMENTARY FIGURE 1401.3(1) GOSSELIN RATINGS
503 COMMENTARY FIGURE 1401.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLY NONTOXIC) GOSSELIN RATING OF 1
COMMENTARY FIGURE 1401.3(3) DOUBLE-WALL HEAT EXCHANGER
COMMENTARY FIGURE 1401.4 SOLAR THERMAL SYSTEMS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC 900/SRCC 300
SECTION 1402 DESIGN AND INSTALLATION
504 COMMENTARY FIGURE 1401.4.1 SOLAR THERMAL COLLECTORS AND PANELS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC 901/SRCC 100
505 COMMENTARY FIGURE 1402.3 SIMPLIFIED SCHEMATIC OF SOLAR WATER HEATING SYSTEM
COMMENTARY FIGURE 1402.4 FLAT-PLATE SOLAR COLLECTORS
507 COMMENTARY FIGURE 1402.5.3 SIMPLIFIED SCHEMATIC OF DRAINBACK FREEZE PROTECTION SYSTEM
COMMENTARY FIGURE 1402.7.1 DOUBLE ENVELOPE PASSIVE SOLAR HEATING
510 SECTION 1403 HEAT TRANSFER FLUIDS
511 SECTION 1404 LABELING
BIBLIOGRAPHY
512 CHAPTER 15: REFERENCED STANDARDS
GENERAL COMMENTS
PURPOSE
513 COMMENTARY FIGURE 15 REFERENCED STANDARDS
514 ACCA
AHRI
AMCA
ANSI
ASHRAE
515 ASME
ASSE
516 ASSE
ASTM
519 AWS
AWWA
520 CPSC
CSA
DOL
FDA
521 FS
ICC
IIAR
522 MSS
NAIMA
NBBI
NFPA
523 NSF
SMACNA
UL
528 APPENDIX A: CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
529 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
530 APPENDIX B: RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS
532 INDEX
538 ICC EVALUATION SERVICE
539 ICC premiumACCESS
540 ICC LEARNING CENTER
541 ICC ASSESSMENT CENTER
ICC IMC Commentary 2018 1stPrint
$80.71