ICC IPC Commentary 2018 1stPrint
$80.71
International Plumbing Code and Commentary
Published By | Publication Date | Number of Pages |
ICC | 2018 | 631 |
This comprehensive publication provides a convenient reference for regulations in the 2018 International Plumbing Code® (IPC®).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2018 IPC® CODE AND COMMENTARY |
2 | 2018 IPC® CODE AND COMMENTARY TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
8 | CHAPTER 1: SCOPE AND ADMINISTRATION GENERAL COMMENTS PURPOSE PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL |
9 | SECTION 102 APPLICABILITY |
12 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF PLUMBING INSPECTION |
13 | SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
14 | SECTION 105 APPROVAL |
16 | SECTION 106 PERMITS |
20 | SECTION 107 INSPECTIONS AND TESTING |
24 | SECTION 108 VIOLATIONS |
26 | SECTION 109 MEANS OF APPEAL |
27 | SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
28 | BIBLIOGRAPHY |
30 | CHAPTER 2: DEFINITIONS GENERAL COMMENTS PURPOSE SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
32 | COMMENTARY FIGURE 202(1) AIR ADMITTANCE VALVE OPENS COMMENTARY FIGURE 202(2) AIR ADMITTANCE VALVE CLOSES |
33 | COMMENTARY FIGURE 202(3) MECHANICAL VENT—NOT CODE COMPLIANT COMMENTARY FIGURE 202(4) AIR GAP, AIR BREAK |
36 | COMMENTARY FIGURE 202(5) DEFINITION OF A BRANCH INTERVAL |
37 | COMMENTARY FIGURE 202(6) BRANCH INTERVALS |
38 | COMMENTARY FIGURE 202(7) BRANCH VENT COMMENTARY FIGURE 202(8) DRAINAGE SYSTEM COMPONENTS |
42 | COMMENTARY FIGURE 202(9) DEPTH OF TRAP SEAL |
44 | COMMENTARY FIGURE 202(10) FIXTURE DRAINS AND FIXTURE BRANCHES COMMENTARY FIGURE 202(11) FIXTURE DRAIN |
47 | COMMENTARY FIGURE 202(12) SENSOR-CONTROLLED GREASE RECOVERY DEVICE COMMENTARY FIGURE 202(13) TIMER-CONTROLLED GREASE RECOVERY DEVICE |
48 | COMMENTARY FIGURE 202(14) GREASE REMOVAL DEVICE, AUTOMATIC COMMENTARY FIGURE 202.(15) TYPES OF WATER DISTRIBUTION SYSTEMS |
53 | COMMENTARY FIGURE 202(16) PARTS OF A PLUMBING SYSTEM |
62 | CHAPTER 3: GENERAL REGULATIONS GENERAL COMMENTS PURPOSE SECTION 301 GENERAL |
64 | SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS COMMENTARY FIGURE 303.1(1) SAMPLE MARKING OF PVC PRESSURE PIPE |
65 | COMMENTARY FIGURE 303.1(2) MARKING OF PVC GRAVITY SEWER PIPE |
66 | SECTION 304 RODENTPROOFING |
67 | SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
68 | COMMENTARY FIGURE 305.2(1) THERMAL EXPANSION RATES FOR PIPING MATERIALS |
69 | COMMENTARY FIGURE 305.2(2) “L” BEND COMMENTARY FIGURE 305.2(3) “Z” BEND |
70 | COMMENTARY FIGURE 305.2(4) “U” BEND |
71 | COMMENTARY FIGURE 305.3(1) PIPE PROTECTION COMMENTARY FIGURE 305.3(2) BUILDING DRAIN PENETRATION THROUGH FOUNDATION WALL |
72 | COMMENTARY FIGURE 305.4(1) PROTECTION AGAINST FREEZING COMMENTARY FIGURE 305.4(2) WATER DISTRIBUTION PIPING IN EXTERIOR WALL |
73 | COMMENTARY FIGURE 305.4(3) PIPING IN EXTERIOR WALL |
74 | COMMENTARY FIGURE 305.4(4) TYPICAL FREEZEPROOF HOSE FAUCET INSTALLATION COMMENTARY FIGURE 305.4(5) SEVERE FROST PENETRATION LEVELS |
75 | COMMENTARY FIGURE 305.4(6) REQUIRED BURIAL DEPTH |
76 | COMMENTARY FIGURE 305.5 ROOF PENETRATIONS |
77 | COMMENTARY FIGURE 305.6(1) REQUIRED SHIELD PLATES COMMENTARY FIGURE 305.6(2) PIPE PROTECTION VIOLATION |
78 | COMMENTARY FIGURE 305.7 PROTECTION OF PLUMBING SYSTEM COMPONENTS SECTION 306 TRENCHING, EXCAVATION AND BACKFILL COMMENTARY FIGURE 306.2 PIPE ON BOTTOM OF TRENCH |
79 | COMMENTARY FIGURE 306.2.1 OVEREXCAVATED TRENCH |
80 | COMMENTARY FIGURE 306.3 TAMPING LOOSE FILL IN 6-INCH LAYERS SECTION 307 STRUCTURAL SAFETY |
81 | COMMENTARY FIGURE 307.2(1) CUTTING, NOTCHING AND BORING OF WALL STUDS COMMENTARY FIGURE 307.2(2) CUTTING, NOTCHING AND BORING OF FLOOR JOISTS, CEILING JOISTS AND RAFTERS |
82 | COMMENTARY FIGURE 307.2(3) NOTCHING AND BORING IN A BEARING WALL COMMENTARY FIGURE 307.2(4) VIOLATION: NOTCH IN FLOOR JOIST TOO DEEP COMMENTARY FIGURE 307.2(5) VIOLATION: HOLES TOO CLOSE TO BOTTOM OF JOIST |
83 | COMMENTARY FIGURE 307.2(6) VIOLATION: NOTCHES TOO DEEP IN WALL STUDS COMMENTARY FIGURE 307.2(7) VIOLATION: EXTERIOR WALLSTUD NOTCHED TOO DEEP COMMENTARY FIGURE 307.2(8) VIOLATION: FLOOR JOIST COMPLETELY SEVERED |
84 | COMMENTARY FIGURE 307.2(9) VIOLATION: EXTERIOR WALL STUD COMPLETELY SEVERE |
85 | COMMENTARY FIGURE 307.2(10) REQUIRED TOP PLATE REINFORCEMENT |
86 | COMMENTARY FIGURE 307.2(11) VIOLATION: WALL TOP PLATES NOT REINFORCED COMMENTARY FIGURE 307.2(12) LAMINATED VENEER LUMBER BEAM COMMENTARY FIGURE 307.2(13) VIOLATION: TOP CHORD OF TRUSS NOTCHED |
87 | COMMENTARY FIGURE 307.2(14) VIOLATION: HOLE IN BOTTOM CHORD OF ROOF TRUSS COMMENTARY FIGURE 307.2(15) VIOLATION: TOP FLANGE OF I-JOIST COMPLETELY SEVERED COMMENTARY FIGURE 307.2(16) VIOLATION: I-JOIST WEB HOLES IRREGULAR SHAPE, TOO LARGE, TOO CLOSE TOGETHER COMMENTARY FIGURE 307.2(17) STRUCTURAL STEEL BEAM |
88 | COMMENTARY FIGURE 307.2(18) FLANGE, LIP AND WEB OF COLD-FORMED STEEL LIGHT-FRAME MEMBER COMMENTARY FIGURE 307.2(19) ALLOWABLE WEB HOLES IN STUDS (PRESCRIPTIVE DESIGN ONLY) COMMENTARY FIGURE 307.2(20) ALLOWABLE WEB HOLES IN MEMBERS OTHER THAN STUDS (PRESCRIPTIVE DESIGN ONLY) |
89 | COMMENTARY FIGURE 307.2(21) ALLOWABLE NOTCHING AND BORING OF STRUCTURAL LOG MEMBERS |
90 | COMMENTARY FIGURE 307.3(1) THROUGH PENETRATION OF ASSEMBLIES COMMENTARY FIGURE 307.3(2) MEMBRANE PENETRATION OF ASSEMBLY |
92 | COMMENTARY FIGURE 307.3(3) TYPICAL FIRESTOP SYTEM DETAIL |
93 | COMMENTARY FIGURE 307.3(4) CAST IRON PIPES PENETRATING CONCRETE FLOOR, INSIDE WALL OF CAVITY COMMENTARY FIGURE 307.3(5) CAST IRON AND COPPER PIPES PENETRATING WALL ASSEMBLY |
94 | COMMENTARY FIGURE 307.3(6) FIRESTOP SYSTEM CHOSEN FOR 2-HR RATED WALL SERVING AS SMOKE BARRIER |
95 | COMMENTARY FIGURE 307.3(6)—continued FIRESTOP SYSTEM CHOSEN FOR 2-HR RATED WALL SERVING AS SMOKE BARRIER |
96 | COMMENTARY FIGURE 307.3(7) VIOLATION: COMMON EXPANDING FOAM SEALANT USED FOR FIRESTOPPING COMMENTARY FIGURE 307.3(8) VIOLATION: PIPING EXCESSIVELY OFFSET THROUGH FIRESTOP SLEEVE ASSEMBLY COMMENTARY FIGURE 307.3(9) VIOLATION: FIRESTOP SLEEVE ASSEMBLIES NOT LOCATED WITHIN WALL COMMENTARY FIGURE 307.4 VIOLATION: TOP CHORD OF FLOOR TRUSS REMOVED COMMENTARY FIGURE 307.5 EXCAVATION IN RELATION TO FOOTING |
97 | SECTION 308 PIPING SUPPORT COMMENTARY FIGURE 308.3(1) PLASTIC HANGER STRAP COMMENTARY FIGURE 308.3(2) PLASTIC INSERT FOR COPPER TUBING THROUGH METAL STUD |
98 | COMMENTARY FIGURE 308.4 POOR HANGER ATTACHMENT TABLE 308.5 HANGER SPACING |
99 | COMMENTARY FIGURE 308.5(1) POINT OF MAXIMUM SAG BETWEEN SUPPORTS COMMENTARY FIGURE 308.5(2) LOCATION OF HANGERS |
100 | COMMENTARY FIGURE 308.6 SWAY BRACING COMMENTARY FIGURE 308.7 RESTRAINED COUPLING |
101 | COMMENTARY FIGURE 308.7.1 ANCHORAGE LOCATION |
102 | COMMENTARY FIGURE 308.9(1) PIPE SUPPORT COMMENTARY FIGURE 308.9(2) PIPE BEND SUPPORT MAINTAINING BEND RADIUS COMMENTARY FIGURE 308.9(3) PIPE BEND SUPPORT MAINTAINING BEND RADIUS |
103 | COMMENTARY FIGURE 308.9(4) PIPE BEND SUPPORT MAINTAINING BEND RADIUS COMMENTARY FIGURE 308.10(1) VIOLATION: THERMAL EXPANSION TANK NOT SUPPORTED COMMENTARY FIGURE 308.10(2) ONE TYPE OF THERMAL EXPANSION TANK SUPPORT |
104 | SECTION 309 FLOOD HAZARD RESISTANCE |
105 | SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 311 TOILET FACILITIES FOR WORKERS |
106 | COMMENTARY FIGURE 311.1 MINIMUM NUMBER OF TOILET FACILITIES SECTION 312 TESTS AND INSPECTIONS |
108 | COMMENTARY FIGURE 312.4(1) SMOKE-GENERATING EQUIPMENT COMMENTARY FIGURE 312.4(2) SMOKE INDICATING PRESENCE OF LEAK |
110 | COMMENTARY FIGURE 312.9 TESTING OF FIELD-FABRICATED SHOWER LINER |
111 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL |
112 | [M] TABLE 314.2.2 CONDENSATE DRAIN SIZING |
113 | COMMENTARY FIGURE 314.2.3(1) CONDENSATE OVERFLOW SWITCH COMMENTARY FIGURE 314.2.3(2) CONDENSATE OVERFLOW SWITCH |
114 | COMMENTARY FIGURE 314.2.3(3) PRIMARY OR AUXILIARY DRAIN PAN FLOAT SWITCH COMMENTARY FIGURE 314.2.3.2 FURNACE ELEVATED ABOVE TOP OF CONDENSATE PAN |
115 | SECTION 315 PENETRATIONS SECTION 316 ALTERNATIVE ENGINEERED DESIGN |
116 | BIBLIOGRAPHY |
118 | CHAPTER 4: FIXTURES, FAUCETS AND FIXTURE FITTINGS GENERAL COMMENTS PURPOSE SECTION 401 GENERAL |
119 | SECTION 402 FIXTURE MATERIALS |
120 | SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
121 | TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
122 | TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.1.1 and 403.2) |
127 | COMMENTARY FIGURE 403.1(1) SOLUTION SUMMARY FOR SAMPLE PROBLEM 1 |
128 | COMMENTARY FIGURE 403.1(2) SOLUTION SUMMARY FOR SAMPLE PROBLEM 2 |
129 | COMMENTARY FIGURE 403.1(3) SOLUTION SUMMARY FOR SAMPLE PROBLEM 3 |
130 | COMMENTARY FIGURE 403.1(4) SOLUTION SUMMARY FOR SAMPLE PROBLEM 4 COMMENTARY FIGURE 403.1(5) BUILDING PLUMBING FIXTURE TOTALS FOR SAMPLE PROBLEM 4 |
132 | COMMENTARY FIGURE 403.3(1) RESTAURANT ENTRY SIGN |
133 | COMMENTARY FIGURE 403.3.1(1) WALK-UP ICE CREAM SHOP WITH OUTDOOR SEATING |
134 | COMMENTARY FIGURE 403.3.1(2) CUSTOMER TOILET ACCESS |
136 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES |
138 | COMMENTARY FIGURE 404.2(1) WATER CLOSET LOCATION COMMENTARY FIGURE 404.2(2) WATER CLOSET HEIGHT COMMENTARY FIGURE 404.2(3) MINIMUM CLEARANCE FOR WATER CLOSET |
139 | COMMENTARY FIGURE 404.2(4) REAR WALL GRAB BAR FOR WATER CLOSET COMMENTARY FIGURE 404.2(5) SIDEWALL GRAB BAR FOR WATER CLOSET |
140 | COMMENTARY FIGURE 404.2(6) INTERNATIONAL SYMBOL FOR ACCESSIBILITY COMMENTARY FIGURE 404.2(7) CHILDREN’S WATER CLOSET LOCATION COMMENTARY FIGURE 404.2(8) CHILDREN’S WATER CLOSET HEIGHT AND SIDEWALL GRAB BARS COMMENTARY FIGURE 404.2(9) WALL HUNG-TYPE URINAL |
141 | COMMENTARY FIGURE 404.2(10) ACCESSIBLE HEIGHT URINAL ON LEFT COMMENTARY FIGURE 404.2(11) BATHTUB WITHOUT PERMANENT SEAT COMMENTARY FIGURE 404.2(12) BATHTUB WITH PERMANENT SEAT COMMENTARY FIGURE 404.2(13) GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS |
142 | COMMENTARY FIGURE 404.2(14) GRAB BARS FOR BATHTUBS WITHOUT PERMANENT SEATS COMMENTARY FIGURE 404.2(15) LOCATION OF BATHTUB CONTROLS |
143 | COMMENTARY FIGURE 404.2(16) TRANSFER-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE COMMENTARY FIGURE 404.2(17) GRAB BARS IN TRANSFER-TYPE SHOWERS COMMENTARY FIGURE 404.2(18) TRANSFER-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION COMMENTARY FIGURE 404.2(19) STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE |
144 | COMMENTARY FIGURE 404.2(20) GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWERS COMMENTARY FIGURE 404.2(21) STANDARD ROLL-IN-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION COMMENTARY FIGURE 404.2(22) ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE COMMENTARY FIGURE 404.2(23) GRAB BARS IN ALTERNATE ROLL-IN SHOWERS |
145 | COMMENTARY FIGURE 404.2(24) ALTERNATE ROLL-IN-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION |
146 | COMMENTARY FIGURE 404.2(25) HEIGHT OF LAVATORIES AND SINKS COMMENTARY FIGURE 404.2(26) KNEE CLEARANCE |
147 | COMMENTARY FIGURE 404.2(27) WALL-MOUNTED ACCESSIBLE LAVATORY COMMENTARY FIGURE 404.2(28) TOE CLEARANCE COMMENTARY FIGURE 404.2(29) ACCESSIBLE KITCHEN SINK |
148 | COMMENTARY FIGURE 404.2(30) ACCESSIBLE DRINKING FOUNTAIN |
151 | COMMENTARY FIGURE 404.2(31) SWING UP GRAB BAR FOR WATER CLOSET |
152 | COMMENTARY FIGURE 404.2(32) PARALLEL APPROACH BATHTUB IN TYPE B UNITS COMMENTARY FIGURE 404.2(33) FORWARD APPROACH BATHTUB IN TYPE B UNITS |
154 | SECTION 405 INSTALLATION OF FIXTURES |
156 | COMMENTARY FIGURE 405.3.1(1) MINIMUM CLEARANCE BETWEEN FIXTURES |
157 | COMMENTARY FIGURE 405.3.1(2) CORNER SINK USER CLEARANCE |
158 | COMMENTARY FIGURE 405.3.3 FIXTURE AND DOOR OBSTRUCTION |
159 | COMMENTARY FIGURE 405.3.5(1) URINAL PARTITIONS COMMENTARY FIGURE 405.3.5(2) URINAL PARTITIONS |
160 | COMMENTARY FIGURE 405.4(1) WATER CLOSET FLOOR FLANGE COMMENTARY FIGURE 405.4(2) GASKETED WASTE TUBE CONNECTION FOR WATER CLOSET |
161 | COMMENTARY FIGURE 405.4.3 WALL-HUNG WATER CLOSET COMMENTARY FIGURE 405.6(1) JOINTS BETWEEN FIXTURES AND WALLS OR FLOORS |
162 | COMMENTARY FIGURE 405.6(2) VIOLATION: LAVATORY NOT ATTACHED OR SEALED TO WALL COMMENTARY FIGURE 405.6(3) LAVATORY PROPERLY SEALED TO WALL COMMENTARY FIGURE 405.8 FIXTURE OVERFLOW |
163 | SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 407 BATHTUBS |
164 | COMMENTARY FIGURE 406.2 CLOTHES WASHER TRENCH DRAIN |
165 | SECTION 408 BIDETS |
166 | SECTION 409 DISHWASHING MACHINES COMMENTARY FIGURE 409.4 RESIDENTIAL DISHWASHER WASTE CONNECTIONS SECTION 410 DRINKING FOUNTAINS |
168 | COMMENTARY FIGURE 410.3 REQUIRED DRINKING FOUNTAINS AND CONFIGURATIONS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS |
169 | COMMENTARY FIGURE 411.1 EMERGENCY SHOWER AND EYEWASH STATION SECTION 412 FAUCETS AND FIXTURE FITTINGS |
171 | COMMENTARY FIGURE 412.1.1(1) AERATED STREAM AERATOR COMMENTARY FIGURE 412.1.1(2) SPRAY AERATOR |
172 | COMMENTARY FIGURE 412.3 TEMPERATURE BURN CHART |
173 | COMMENTARY FIGURE 412.4 DELIVERED WATER TEMPERATURE LIMITS AND TEMPERATURE CONTROL OR DEVICE |
176 | SECTION 413 FLOOR AND TRENCH DRAINS COMMENTARY FIGURE 413.1 TRENCH DRAIN |
177 | FIGURE 413.2(1) TYPICAL FLOOR DRAIN WITHOUT INTEGRAL TRAP COMMENTARY FIGURE 413.2(2) TYPICAL FLOOR DRAIN WITH INTEGRAL TRAP SECTION 414 FLOOR SINKS |
178 | SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
179 | SECTION 416 FOOD WASTE DISPOSER UNITS |
180 | COMMENTARY FIGURE 416.3 COMMERCIAL FOOD WASTE DISPOSER SECTION 417 GARBAGE CAN WASHERS |
181 | COMMENTARY FIGURE 417.2 GARBAGE CAN WASHER SECTION 418 LAUNDRY TRAYS SECTION 419 LAVATORIES COMMENTARY FIGURE 419.1 GROUP WASH-UP FIXTURE |
182 | COMMENTY FIGURE 419.4 ADJUSTABLE HEIGHT SHAMPOO BOWL SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 421 SHOWERS |
183 | COMMENTARY FIGURE 421.2(1) SPECIAL BRACKET FOR SHOWER RISER COMMENTARY FIGURE 421.2(2) SECURING SHOWER RISER |
184 | COMMENTARY FIGURE 421.3 SHOWER FLOOR DESIGN FOR GANG SHOWERS COMMENTARY FIGURE 421.4 SHOWER COMPARTMENT |
186 | COMMENTARY FIGURE 421.5.2 BUILT-UP SHOWER: DRAIN AND LINER ARRANGEMENT |
187 | SECTION 422 SINKS SECTION 423 SPECIALTY PLUMBING FIXTURES |
188 | SECTION 424 URINALS |
189 | COMMENTARY FIGURE 424.1(1) WATERLESS URINAL COMMENTARY FIGURE 424.1(2) WATERLESS URINAL CARTRIDGE SECTION 425 WATER CLOSETS |
190 | COMMENTARY FIGURE 425.1(1) WATER CLOSET RIM HEIGHT |
191 | COMMENTARY FIGURE 425.4 ACCEPTABLE 4 X 3 CLOSET BENDS |
192 | COMMENTARY FIGURE 426.5(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS (PIPES BLOCKING ACCESS) COMMENTARY FIGURE 426.5(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS (PUMP CANNOT BE REACHED |
194 | CHAPTER 5: WATER HEATERS GENERAL COMMENTS PURPOSE SECTION 501 GENERAL |
197 | COMMENTARY FIGURE 501.2 WATER-TO-AIR HEAT EXCHANGER |
199 | COMMENTARY FIGURE 501.6(1) TYPICAL CAPACITY GRAPH FOR TANKLESS WATER HEATERS COMMENTARY FIGURE 501.6(2) TYPICAL CAPACITY TABLE FOR TANKLESS WATER HEATERS COMMENTARY FIGURE 501.6(3) OPERATING POINT FOR TANKLESS WATER HEATERS |
201 | SECTION 502 INSTALLATION |
203 | SECTION 503 CONNECTIONS |
204 | COMMENTARY FIGURE 503.1(1) WATER HEATER VALVE COMMENTARY FIGURE 503.1(2) PLASTIC PIPE TOO CLOSE TO DRAFT HOOD OF GAS-FIRED WATER HEATER |
205 | COMMENTARY FIGURE 503.1(3) SPECIAL HEAT TRAP PIPE NIPPLE COMMENTARY FIGURE 503.1(4) PIPE AND FITTING U-SHAPE HEAT TRAPS |
206 | COMMENTARY FIGURE 503.1(5) FLEXIBLE WATER HEATER CONNECTOR LOOP FOR HEAT TRAP COMMENTARY FIGURE 503.2 CIRCULATING-TYPE WATER HEATERS CONNECTED TO STORAGE TANKS SECTION 504 SAFETY DEVICES |
207 | COMMENTARY FIGURE 504.2 WATER HEATER WITH BOTTOM FEED COMMENTARY FIGURE 504.3 ELECTRIC DISCONNECT ADJACENT TO WATER HEATER |
208 | COMMENTARY FIGURE 504.4 COMBINATION TEMPERATURE AND PRESSURE-RELIEF VALVE |
209 | COMMENTARY FIGURE 504.4.1 TEMPERATURE- AND PRESSURE-RELIEF VALVE INSTALLATION |
210 | COMMENTARY FIGURE 504.5C OMBINATION TEMPERATURE AND PRESSURE-RELIEF VALVE LABEL COMMENTARY FIGURE 504.6(1) RELIEF VALVE DISCHARGE |
212 | COMMENTARY FIGURE 504.6(2) T&P RELIEF VALVE PERMITTED TO DISCHARGE TO THE PAN |
213 | COMMENTARY FIGURE 504.6(3) RELIEF VALVE DISCHARGE DRAINAGE PIPING SYSTEM COMMENTARY FIGURE 504.6(4) VIOLATION: CAPPED RELIEF VALVE TANK TAPPING AND PLUGGED RELIEF VALVE OPENING |
214 | SECTION 505 INSULATION |
216 | CHAPTER 6:: WATER SUPPLY AND DISTRIBUTION GENERAL COMMENTS PURPOSE SECTION 601 GENERAL |
217 | SECTION 602 WATER REQUIRED |
219 | SECTION 603 WATER SERVICE COMMENTARY FIGURE 603.1(1) WATER SERVICE SYSTEM, PUBLIC WATER MAIN |
220 | COMMENTARY FIGURE 603.1(2) WATER SERVICE SYSTEM, PRIVATE WELL |
221 | COMMENTARY FIGURE 603.1(3) DIFFERENCE IN ELEVATION, LOSS OF PRESSURE COMMENTARY FIGURE 603.1(4) DIFFERENCE IN ELEVATION, GAIN OF PRESSURE |
223 | COMMENTARY FIGURE 603.1(5) FRICTION LOSS IN SDR 9 PEX TUBING |
224 | COMMENTARY FIGURE 603.1(6) CAVITATION |
225 | COMMENTARY FIGURE 603.1(7) FRICTION LOSS FOR DISPLACEMENT-TYPE WATER METERS |
226 | COMMENTARY FIGURE 603.1(8) FRICTION LOSS IN SMOOTH PIPE (Type L, ASTM B88 COPPER TUBING) |
228 | COMMENTARY FIGURE 603.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER |
229 | COMMENTARY FIGURE 603.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER COMMENTARY FIGURE 603.2.1 MINIMUM HORIZONTAL SEPARATION DISTANCES BETWEEN WATER SOURCE ELEMENTS AND SOIL ABSORPTION SYSTEM COMPONENTS SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM |
231 | COMMENTARY FIGURE 604.1(1) MAXIMUM FLOW VELOCITY FOR VARIOUS PIPE MATERIALS |
232 | COMMENTARY FIGURE 604.1(2) WATER SYSTEM SCHEMATIC, THREE-STORY COMPACT BUILDING |
233 | COMMENTARY FIGURE 604.1(3) SOLUTION FOR SAMPLE PROBLEM 1 |
234 | COMMENTARY FIGURE 604.1(4) WATER SYSTEM SCHEMATIC, SINGLE-STORY, 16-UNIT MOTEL |
235 | COMMENTARY FIGURE 604.1(5) SPREADSHEET SETUP FOR SAMPLE PROBLEM 2 |
236 | COMMENTARY FIGURE 604.1(6) COMPLETED SPREADSHEET FOR SAMPLE PROBLEM 2—COLD SIDE |
237 | COMMENTARY FIGURE 604.1(7) COMPLETED SPREADSHEET FOR SAMPLE PROBLEM 2—HOT SIDE |
238 | COMMENTARY FIGURE 604.1(8) WATER SYSTEM SCHEMATIC, EIGHT-STORY, 96-UNIT APARTMENT BUILDING COMMENTARY FIGURE 604.1(9) SAMPLE PROBLEM 3—PIPE SIZING TABLE |
239 | COMMENTARY FIGURE 604.1(10) SAMPLE PROBLEM 3—SECTION PIPE SIZES |
240 | TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS |
242 | TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS |
243 | TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES COMMENTARY FIGURE 604.5 WATER SUPPLY CONNECTION WITH REDUCED-SIZE FLEXIBLE SUPPLY |
246 | COMMENTARY FIGURE 604.9(1) EXAMPLE OF MECHANICAL WATER-HAMMER ARRESTORS COMMENTARY FIGURE 604.9(2) AIR CHAMBER WATER-HAMMER ARRESTOR |
247 | TABLE 604.10.1 MANIFOLD SIZING |
248 | COMMENTARY FIGURE 604.10(1) FIELD-BUILT MANIFOLD FOR PARALLEL WATER DISTRIBUTION COMMENTARY FIGURE 604.10(2) FACTORY-BUILT MANIFOLD FOR PARALLEL WATER DISTRIBUTION |
249 | SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
251 | COMMENTARY FIGURE 605.3(1) TYPICAL WATER SERVICE PIPE ENTRY INTO BUILDING |
252 | COMMENTARY FIGURE 605.3(2) WATER SERVICE EXTENDING INTO BUILDING COMMENTARY FIGURE 605.3(3) WATER SERVICE PIPING EXTENDED UNDER SLAB AND THEN UP INTO BUILDING |
253 | TABLE 605.3 WATER SERVICE PIPE |
255 | COMMENTARY FIGURE 605.3(3) SAMPLE MARKING OF PEX TUBING |
256 | COMMENTARY FIGURE 5.3(4) DUCTILE IRON PIPE LINING THICKNESS |
257 | COMMENTARY FIGURE 605.3(5) STEEL PIPE DIMENSIONS SCHEDULE 40 |
260 | TABLE 605.4 WATER DISTRIBUTION PIPE |
261 | TABLE 605.5 PIPE FITTINGS |
262 | COMMENTARY FIGURE 605.5.1 DRILLING AND PULLING BRANCH OUTLETS COMMENTARY FIGURE 605.5.1.1 SPECIALLY PREPARED BRANCH PIPE END COMMENTARY FIGURE 605.5.1.2 BRAZED CONNECTION |
263 | TABLE 605.7 VALVES TABLE 605.8 MANUFACTURED PIPE NIPPLES |
265 | COMMENTARY FIGURE 605.12.1 HEAT APPLICATION OF BRAZED JOINT |
266 | COMMENTARY FIGURE 605.12.3 PREPARATION OF PIPE END |
267 | COMMENTARY FIGURE 605.13.2(1) TYPICAL FLARED TUBE JOINT COMMENTARY FIGURE 605.13.2(2) TYPICAL FLARED TUBE JOINT |
270 | COMMENTARY FIGURE 605.16.2 PEX TUBING CONNECTION |
272 | COMMENTARY FIGURE 605.18.4 BENDING PE PLASTIC PIPE |
274 | COMMENTARY FIGURE 605.23.1(1) CORROSIVE HIERARCHY OF METALS |
275 | COMMENTARY FIGURE 605.23.1(2) DIELECTRIC UNION COMMENTARY FIGURE 605.23.1(3) DIELECTRIC FLANGE FITTING COMMENTARY FIGURE 605.23.1(4) CORROSION CAUSED BY ABSENCE OF DIELECTRIC FITTINGS |
276 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM |
277 | COMMENTARY FIGURE 606.1(1) CURB VALVE ON WATER SUPPLY COMMENTARY FIGURE 606.1(2) VALVE AT ENTRANCE TO BUILDING AND ON DISCHARGE SIDE OF METER |
278 | COMMENTARY FIGURE 606.1(3) VALVES FOR EACH RISER AND DOWNFEED COMMENTARY FIGURE 606.1(4) DWELLING UNIT VALVEs COMMENTARY FIGURE 606.1(5) VALVES ON SUPPLY TO EACH TANK |
279 | COMMENTARY FIGURE 606.1(6) WATER HEATER VALVE |
280 | COMMENTARY FIGURE 606.2(1) SHUTOFF VALVE FOR EACH FIXTURE COMMENTARY FIGURE 606.2(2) SILL FAUCET VALVE |
281 | TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS |
282 | TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS |
283 | SECTION 607 HOT WATER SUPPLY SYSTEM |
284 | COMMENTARY FIGURE 607.2 TEMPERATURE MAINTENANCE SYSTEM FOR HOT WATER USING PUMPED CIRCULATION LOOP |
286 | COMMENTARY FIGURE 607.2.2(1) PROPER ARRANGEMENT FOR TEMPERED WATER RECIRCULATION RETURN |
287 | COMMENTARY FIGURE 607.2.2(2) IMPROPER ARRANGEMENT FOR TEMPERED WATER RECIRCULATION RETURN COMMENTARY FIGURE 607.2.2(3) IMPROPER ARRANGEMENT FOR TEMPERED WATER RECIRCULATION RETURN |
289 | COMMENTARY FIGURE 607.3 THERMAL EXPANSION CONTROL USING THERMAL |
294 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
295 | COMMENTARY FIGURE 608.1(1) ATMOSPHERIC PRESSURE VARIES WITH ELEVATION |
296 | COMMENTARY FIGURE 608.1(2) PRESSURE EXERTED BY 1 CUBIC FOOT OF WATER |
297 | COMMENTARY FIGURE 608.1(3) PRESSURE EXERTED BY A COLUMN OF WATER COMMENTARY FIGURE 608.1(4) BASE PRESSURE COMMENTARY FIGURE 608.1(5) COLUMN OF WATER EXPOSED TO ATMOSPHERE COMMENTARY FIGURE 608.1(6) OPEN TUBE INSERTED IN CONTAINER OF WATER |
298 | COMMENTARY FIGURE 608.1(7) VACUUM APPLIED TO A SEALED TUBE INSERTED IN A CONTAINER OF WATER COMMENTARY FIGURE 608.1(8) EXAMPLE OF SIMPLE SIPHON |
299 | COMMENTARY FIGURE 608.1(9) EXAMPLE OF ASPIRATION, OR VENTURI PRINCIPLE COMMENTARY FIGURE 608.1(10) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE |
300 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
301 | COMMENTARY FIGURE 608.7.1 CONNECTION BETWEEN TWO SYSTEMS |
302 | COMMENTARY FIGURE 608.8(1) YARD HYDRANT WITH STOP-AND-WASTE VALVE COMMENTARY FIGURE 608.8(2) PROHIBITED INSTALLATION OF YARD HYDRANTS CONNECTED TO WATER SERVICE LINES |
303 | FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION |
307 | COMMENTARY FIGURE 608.14.4 BAROMETRIC LOOP COMMENTARY FIGURE 608.14.5 PRESSURE VACUUM BREAKER |
308 | COMMENTARY FIGURE 608.14.7 DOUBLE CHECK-VALVE ASSEMBLY |
310 | COMMENTARY FIGURE 608.16.1(1) AIR GAP FOR A LAVATORY FAUCET |
311 | COMMENTARY FIGURE 608.16.1(2) AIR GAP FOR A PIPING SYSTEM TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS |
312 | COMMENTARY FIGURE 608.16.1(3) AIR GAPS—LOCATED NEAR SINGLE WALL COMMENTARY FIGURE 608.16.1(4) AIR GAPS—LOCATED NEAR INTERSECTING WALLS COMMENTARY FIGURE 608.16.4 SUBMERGED INLET PROTECTED BY VACUUM BREAKER |
313 | COMMENTARY FIGURE 608.16.4.2(1) HOSE (SILL) FAUCET WITHOUT VACUUM BREAKER COMMENTARY FIGURE 608.16.4.2(2) HOSE (SILL) FREEZE PROOF FAUCET WITH INTEGRAL VACUUM BREAKER COMMENTARY FIGURE 608.16.4.2(3) HOSE CONNECTION VACUUM BREAKER |
314 | COMMENTARY FIGURE 608.17.1.1 BEVERAGE DISPENSER |
315 | COMMENTARY FIGURE 608.17.2 FOR BOILER WITHOUT CONDITIONING CHEMICALS COMMENTARY FIGURE 608.17.3(1) GOSSELIN RATINGS |
316 | COMMENTARY FIGURE 608.17.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLY NONTOXIC) GOSSELIN RATING OF 1 COMMENTARY FIGURE 608.17.3(3) DOUBLE-WALL HEAT EXCHANGER |
317 | COMMENTARY FIGURE 608.17.4(1) COMMON FIRE SPRINKLER AND DOMESTIC WATER SUPPLY COMMENTARY FIGURE 608.17.4(2) COMBINATION WATER DISTRIBUTION/AUTOMATIC SPRINKLER SYSTEM |
320 | COMMENTARY FIGURE 608.17.6 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER |
321 | TABLE 608.18.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES |
322 | COMMENTARY FIGURE 608.18.3 DEPTH OF WELL COMMENTARY FIGURE 608.18.4 WELL CASING |
323 | COMMENTARY FIGURE 608.18.5 CASING FOR DRILLED OR DRIVEN WELL COMMENTARY FIGURE 608.18.7 DUG WELL COVER SECTION 609 HEALTH CARE PLUMBING COMMENTARY FIGURE 609.2 DUAL WATER SERVICE FOR HOSPITALS |
324 | SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM |
325 | SECTION 611 DRINKING WATER TREATMENT UNITS |
326 | SECTION 612 SOLAR SYSTEMS SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES BIBLIOGRAPHY |
328 | CHAPTER 7: SANITARY DRAINAGE GENERAL COMMENTS PURPOSE SECTION 701 GENERAL |
330 | COMMENTARY FIGURE 701.3(1) COMMON BUILDING SEWER LOCATED WITHIN A PUBLIC UTILITY SEWER EASEMENT COMMENTARY FIGURE 701.3(2) PRIVATELY CONTROLLED SEWER FOR BUILDINGS ON SAME LOT SECTION 702 MATERIALS |
332 | TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
334 | COMMENTARY FIGURE 702.1 SCHEDULE 40 STEEL PIPE DIMENSIONS |
335 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE |
336 | TABLE 702.3 BUILDING SEWER PIPE |
338 | TABLE 702.4 PIPE FITTINGS |
340 | SECTION 703 BUILDING SEWER |
341 | SECTION 704 DRAINAGE PIPING INSTALLATION |
342 | TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE |
344 | COMMENTARY FIGURE 704.3 ZONE FOR POTENTIAL HYDRAULIC JUMP |
345 | SECTION 705 JOINTS |
347 | COMMENTARY FIGURE 705.3.1 CAULKED JOINT FOR HUB AND SPIGOT (CAST-IRON) COMMENTARY FIGURE 705.3.2 CAST-IRON COMPRESSION GASKET JOINT |
348 | COMMENTARY FIGURE 705.3.3 HUBLESS CAST-IRON DRAINAGE PIPE JOINT COMMENTARY FIGURE 705.4 CONCRETE PIPE AND FITTING JOINT |
349 | COMMENTARY FIGURE 705.5.1 HEAT APPLICATION FOR BRAZING A JOINT COMMENTARY FIGURE 705.5.3 PREPARATION OF PIPE END |
351 | COMMENTARY FIGURE 705.9.2 LEAD-WIPED JOINT |
355 | COMMENTARY FIGURE 705.16.3 CAST-IRON ADAPTER FITTING |
356 | COMMENTARY FIGURE 705.17(1) SLIP JOINT, FLAT-RING STYLE |
357 | COMMENTARY FIGURE 705.17(2) SLIP JOINTS, V-SHAPE O-RING STYLE COMMENTARY FIGURE 705.17(3) TYPICAL LOCATIONS FOR SLIP JOINTS TABLE 705.18 CAULKING FERRULE SPECIFICATIONS TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
359 | COMMENTARY FIGURE 706.3(1) COMPARISON OF DIFFERENT SWEEP PATTERNS FOR VARIOUS MATERIALS |
360 | COMMENTARY FIGURE 706.3(2) COMPARISON OF COMBINATION WYE AND EIGHTH-BEND PATTERNS FOR VARIOUS MATERIALS TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION |
361 | COMMENTARY FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS COMMENTARY FIGURE 706.3(4) DIFFERENCE BETWEEN PVC AND ABS PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT |
362 | COMMENTARY FIGURE 706.3(5) COMBINATION TEES COMMENTARY FIGURE 706.3(6) FITTING USES |
363 | COMMENTARY FIGURE 706.3(7) IMPROPER USE OF DWV-PVC/ABS 90-DEGREE FITTINGS COMMENTARY FIGURE 706.3(8) PROPER USE OF DWV-PVC/ABS 90-DEGREE FITTINGS COMMENTARY FIGURE 706.3(9) BACK-TO-BACK WATER CLOSETS CONNECTED TO DOUBLE SANITARY TEE COMMENTARY FIGURE 706.3(10) WATER CLOSET FIXTURE DRAINS CONNECTED TO TEE-WYE OR COMBINATION FITTING |
365 | COMMENTARY FIGURE 706.4(1) HEEL- AND SIDE-INLET QUARTER BEND APPLICATION RESTRICTIONS COMMENTARY FIGURE 706.4(2) SIDE-INLET QUARTER BEND FOR WATER CLOSET COMMENTARY FIGURE 706.4(3) HEEL INLET FITTINGS SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
367 | COMMENTARY FIGURE 708.1.2 MANHOLES INSIDE THE BUILDING |
368 | FIGURE 708.1.3 CLEANOUTS AT BUILDING DRAIN TO BUILDING SEWER JUNCTION |
369 | COMMENTARY FIGURE 708.1.4 CLEANOUTS COMMENTARY FIGURE 708.1.5(1) ACCEPTABLE CLEANOUTS |
370 | COMMENTARY FIGURE 708.1.5(2) CLEANOUT SIZES FOR CAST-IRON PIPING |
371 | COMMENTARY FIGURE 708.1.8 TWO-WAY CLEANOUT FITTING COMMENTARY FIGURE 708.1.9 CLEARANCE FOR CLEANOUTS |
373 | COMMENTARY FIGURE 708.1.10 CLEANOUT INSTALLATIONS COMMENTARY FIGURE 708.1.10.1 CLEANOUTS ON CONCEALED PIPING |
374 | SECTION 709 FIXTURE UNITS |
375 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
376 | TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING |
377 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS COMMENTARY FIGURE 710.1(1) BUILDING DRAIN SIZING |
378 | TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa COMMENTARY FIGURE 710.1(2) HORIZONTAL BRANCH SIZING |
379 | COMMENTARY FIGURE 710.1(3) ALLOWABLE STACK DRAINAGE FIXTURE UNITS |
380 | COMMENTARY FIGURE 710.1(4) STACK SIZING COMMENTARY FIGURE 710.1(5) STACK SIZING GREATER THAN THREE BRANCH INTERVALS COMMENTARY FIGURE 710.1(6) SIZING OF STACK THREE BRANCH INTERVALS OR LESS |
381 | COMMENTARY FIGURE 710.1(7) FLOW IN A STACK COMMENTARY FIGURE 710.1(8) REDUCING SIZE OF DRAINAGE STACK SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE |
382 | COMMENTARY FIGURE 711.1(1) VERTICAL STACK OFFSET WITHOUT BRANCH CONNECTIONS WITHIN 2 FEET ABOVE OR BELOW OFFSET |
383 | COMMENTARY FIGURE 711.1(2) VERTICAL STACK OFFSET WITH BRANCH CONNECTIONS WITHIN 2 FEET ABOVE OR BELOW OFFSET |
384 | COMMENTARY FIGURE 711.2(1) HORIZONTAL STACK OFFSET WITH VENTING SECTION 712 SUMPS AND EJECTORS |
385 | COMMENTARY FIGURE 711.2(2) HORIZONTAL STACK OFFSET WITH VENTING EXAMPLE |
386 | COMMENTARY FIGURE 711.2.1 HORIZONTAL STACK OFFSET—VENTING NOT REQUIRED COMMENTARY FIGURE 711.3(1) VERTICAL OFFSET SIZING WHERE THERE ARE NO STACK CONNECTIONS BELOW OFFSET COMMENTARY FIGURE 711.3(2) HORIZONTAL OFFSET SIZING WHERE THERE ARE NO STACK CONNECTIONS BELOW OFFSET |
387 | COMMENTARY FIGURE 712.1(1) PNEUMATIC SEWAGE EJECTOR FIGURE 712.1(2) VERTICAL SUSPENDED WET PIT SEWAGE PUMP |
388 | COMMENTARY FIGURE 712.2 SEWAGE PUMP INSTALLATION |
390 | TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 COMPUTERIZED DRAINAGE DESIGN |
391 | COMMENTARY FIGURE 712.4.1(1) MACERATING TOILET SYSTEMS COMMENTARY FIGURE 712.4.1(2) MACERATING TOILET SYSTEM GRINDER/PUMP |
392 | SECTION 714 BACKWATER VALVES |
393 | COMMENTARY FIGURE 714.1 BACKWATER VALVE INSTALLATION COMMENTARY FIGURE 714.2 COMMON TYPES OF BACKWATER VALVES |
394 | SECTION 715 VACUUM DRAINAGE SYSTEMS |
395 | SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS |
398 | CHAPTER 8: INDIRECT/SPECIAL WASTE GENERAL COMMENTS PURPOSE SECTION 801 GENERAL |
399 | SECTION 802 INDIRECT WASTES |
400 | COMMENTARY FIGURE 802.1.1(1) INDIRECTLY CONNECTED THREE-COMPARTMENT FOOD PREPARATION SINK COMMENTARY FIGURE 802.1.1(2) REFRIGERATED FOOD CASE DRAINS INDIRECTLY CONNECTING TO HUB DRAIN |
401 | COMMENTARY FIGURE 802.1.1(3) COMMERCIAL KITCHEN INDIRECT WASTE |
402 | COMMENTARY FIGURE 802.1.2(1) FLOOR DRAIN IN FOOD STORAGE REFRIGERATOR (NONFREEZING) COMMENTARY FIGURE 802.1.2(2) FLOOR DRAIN IN FOOD STORAGE FREEZER, AIR BREAK TERMINATION |
403 | COMMENTARY FIGURE 802.1.2(3) FLOOR DRAIN IN FOOD STORAGE FREEZER, AIR GAP TERMINATION COMMENTARY FIGURE 802.1.3 INDIRECT CONNECTION FOR POTABLE CLEAR-WATER WASTE |
404 | COMMENTARY FIGURE 802.1.4 SWIMMING POOL WASTE DISCHARGE THROUGH AIR GAP |
405 | COMMENTARY FIGURE 802.1.5 INDIRECT CONNECTION—NONPOTABLE CLEAR-WATER WASTE |
406 | COMMENTARY FIGURE 802.1.6 COMMERCIAL DISHWASHER INDIRECT WASTE CONNECTIONS |
408 | COMMENTARY FIGURE 802.3 TRAPS REQUIREMENTS FOR INDIRECT WASTE PIPING COMMENTARY FIGURE 802.3.1 AIR GAP |
409 | COMMENTARY FIGURE 802.3.2 AIR BREAK |
410 | COMMENTARY FIGURE 802.4(1) WASTE RECEPTORS COMMENTARY FIGURE 802.4(2) WASTE RECEPTORS |
411 | COMMENTARY FIGURE 802.4(3) PROHIBITED LOCATIONS FOR WASTE RECEPTORS |
412 | COMMENTARY FIGURE 802.4.1(1) SHALLOW, FLAT BOTTOM WASTE RECEPTOR COMMENTARY FIGURE 802.4.1(2) DEEP, ROUNDED-BOTTOM WASTE RECEPTOR COMMENTARY FIGURE 802.4.2 CLEAR-WATER WASTE RECEPTOR |
413 | COMMENTARY FIGURE 802.4.3 STANDPIPES SECTION 803 SPECIAL WASTES |
414 | CHAPTER 9: VENTS GENERAL COMMENTS PURPOSE SECTION 901 GENERAL |
415 | COMMENTARY FIGURE 901.2(1) LOSS OF TRAP SEAL COMMENTARY FIGURE 901.2(2) MAXIMUM TRAP SEAL RESISTANCE |
416 | SECTION 902 MATERIALS |
417 | SECTION 903 VENT TERMINALS COMMENTARY FIGUSRE 903.1 VENT TERMINAL |
418 | COMMENTARY FIGURE 903.5 SEPARATION OF VENT TERMINAL |
419 | COMMENTARY FIGURE 903.6 SIDEWALL VENT SECTION 904 OUTDOOR VENT EXTENSIONS |
420 | COMMENTARY FIGURE 904.1(1) REDUCTION OF STACK VENT CONNECTION COMMENTARY FIGURE 904.1(2) STACK VENT |
421 | COMMENTARY FIGURE 904.1(3) REQUIRED VENT TO OUTDOORS |
422 | COMMENTARY FIGURE 904.4 VENT CONNECTION AT BASE OF STACK SECTION 905 VENT CONNECTIONS AND GRADES |
423 | COMMENTARY FIGURE 904.5 VENT HEADERS |
424 | COMMENTARY FIGURE 905.2 GRADE OF VENTS COMMENTARY FIGURE 905.3 VENT CONNECTIONS |
425 | COMMENTARY FIGURE 905.4 VERTICAL RISE OF VENT |
426 | COMMENTARY FIGURE 905.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN COMMENTARY FIGURE 905.5(2) PROPERLY CONNECTED VENT SERVING A DRAIN COMMENTARY FIGURE 905.5(3) HORIZONTAL BRANCH VENT ELEVATION |
427 | SECTION 906 VENT PIPE SIZING COMMENTARY FIGURE 906.1(1) VENT STACK SIZING COMMENTARY FIGURE 906.1(2) VENT STACK SIZING |
428 | COMMENTARY FIGURE 906.1(3) STACK VENT SIZING |
429 | TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
430 | COMMENTARY FIGURE 906.2(1) VENT SIZING COMMENTARY FIGURE 906.2(2) VENT SIZING |
431 | COMMENTARY FIGURE 906.2(3) VENT SIZING COMMENTARY FIGURE 906.2(4) VENT SIZING |
432 | COMMENTARY FIGURE 906.3(1) DEVELOPED LENGTH OF VENTS COMMENTARY FIGURE 906.3(2) DEVELOPED LENGTH OF VENTS |
433 | COMMENTARY FIGURE 906.4 COMMON BRANCH VENT COMMENTARY FIGURE 906.5.1 SUMP VENT |
434 | TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS SECTION 907 VENTS FOR STACK OFFSETS |
435 | COMMENTARY FIGURE 907.2 VENT CONNECTIONS FOR HORIZONTAL OFFSET SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS |
436 | COMMENTARY FIGURE 908.1 RELIEF VENT CONNECTION SECTION 909 FIXTURE VENTS TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT |
437 | COMMENTARY FIGURE 909.1(1) DISTANCE FROM TRAP TO VENT COMMENTARY FIGURE 909.1(2) MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT AND VENT |
438 | COMMENTARY FIGURE 909.2(1) TRAP TO VENT DISTANCE FOR WATER CLOSETS COMMENTARY FIGURE 909.2(2) VENT CONNECTION |
439 | COMMENTARY FIGURE 909.2(3) SELF-SIPHONING PHENOMENON SECTION 910 INDIVIDUAL VENT SECTION 911 COMMON VENT |
440 | COMMENTARY FIGURE 909.3(1) CROWN VENTING COMMENTARY FIGURE 909.3(2) MINIMUM TRAP-TO-VENT DISTANCE COMMENTARY FIGURE 910.1(1) INDIVIDUAL VENTS COMMENTARY FIGURE 910.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS |
441 | COMMENTARY FIGURE 911.1 COMMON VENTS COMMENTARY FIGURE 911.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL |
442 | TABLE 911.3 COMMON VENT SIZES COMMENTARY FIGURE 911.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS |
443 | SECTION 912 WET VENTING COMMENTARY FIGURE 912.1(1) HORIZONTAL WET VENTING OF BATHROOM FIXTURES |
444 | COMMENTARY FIGURE 912.1(2) HORIZONTAL WET VENT WITH INDIVIDUAL VENT COMMENTARY FIGURE 912.1(3) HORIZONTAL WET VENT WITH COMMON VENTED FIXTURES UPSTREAM COMMENTARY FIGURE 912.1(4) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENT CONNECTION COMMENTARY FIGURE 912.1(5) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY-VENTED FIXTURE CONNECTION COMMENTARY FIGURE 912.1(6) HORIZONTAL WET VENT WITH COMMON VENT WITH AN ADDITIONAL DRY-VENTED FIXTURE |
445 | COMMENTARY FIGURE 912.1(7) HORIZONTAL WET VENT WITH THREE ADDITIONAL INDEPENDENTLY VENTED FIXTURES |
446 | COMMENTARY FIGURE 912.1(8) HORIZONTAL WET VENT SIZING (PRIVATE BATH GROUP) COMMENTARY FIGURE 912.1(9) HORIZONTAL WET VENT (PUBLIC BATH GROUP) COMMENTARY FIGURE 912.1(10) HORIZONTAL WET VENT |
447 | COMMENTARY FIGURE 912.1(11) HORIZONTAL WET VENT COMMENTARY FIGURE 912.1(12) HORIZONTAL WET VENT |
448 | COMMENTARY FIGURE 912.1(13) NONCOMPLIANT HORIZONTAL WET VENT COMMENTARY FIGURE 912.1(14) NONCOMPLIANT HORIZONTAL WET VENT |
449 | COMMENTARY FIGURE 912.1(15) NONCOMPLIANT HORIZONTAL WET VENT COMMENTARY FIGURE 912.1(16) NONCOMPLIANT HORIZONTAL WET VENT COMMENTARY FIGURE 912.1(17) NONCOMPLIANT HORIZONTAL WET VENT COMMENTARY FIGURE 912.1(18) NONCOMPLIANT HORIZONTAL WET VENT |
450 | COMMENTARY FIGURE 912.1(19) MULTIFLOOR WET VENTING COMMENTARY FIGURE 912.1(20) SINGLE BATHROOM GROUP (PRIVATE) WET VENT COMMENTARY FIGURE 912.1(21) DOUBLE BATHROOM GROUP (PRIVATE) WET VENT COMMENTARY FIGURE 912.1(22) WET VENT VARIATIONS FOR A SINGLE BATHROOM GROUP |
451 | COMMENTARY FIGURE 912.1(23) HORIZONTAL WET VENTING COMMENTARY FIGURE 912.1(24) MULTIPLE INDIVIDUAL VENTS |
452 | COMMENTARY FIGURE 912.1.1(1) VERTICAL WET VENT OF SINGLE BATHROOM GROUP COMMENTARY FIGURE 912.1.1(2) VERTICAL WET VENT OF TWO BATHROOM GROUPS COMMENTARY FIGURE 912.1.1(3) VERTICAL WET VENT OF TWO BATHROOM GROUPS |
453 | COMMENTARY FIGURE 912.1.1(4) VERTICAL WET VENTING TABLE 912.3 WET VENT SIZE |
454 | SECTION 913 WASTE STACK VENT COMMENTARY FIGURE 913.2(1) WASTE STACK VENT |
455 | COMMENTARY FIGURE 913.2(2) WASTE STACK VENT TABLE 913.4 WASTE STACK VENT SIZE |
456 | COMMENTARY FIGURE 913.3 WASTE STACK VENT OFFSETS AND STACK VENT CONNECTIONS SECTION 914 CIRCUIT VENTING |
457 | COMMENTARY FIGURE 914.1(1) CIRCUIT VENTING |
458 | COMMENTARY FIGURE 914.1(2) ROUGH-IN FOR EIGHT CIRCUIT-VENTED FIXTURES COMMENTARY FIGURE 914.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES |
459 | COMMENTARY FIGURE 914.2 BACK-TO-BACK WATER CLOSETS CIRCUIT VENTED COMMENTARY FIGURE 914.3 SIZING A CIRCUIT-VENT SYSTEM COMMENTARY FIGURE 914.3.1 SIZING MULTIPLE CIRCUIT-VENTED BRANCHES |
460 | COMMENTARY FIGURE 914.4.1 CIRCUIT VENT WITH RELIEF VENT CONNECTION SECTION 915 COMBINATION WASTE AND VENT SYSTEM |
461 | COMMENTARY FIGURE 914.5(1) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS COMMENTARY FIGURE 914.5(2) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS |
462 | COMMENTARY FIGURE 915.2(1) COMBINATION WASTE AND VENT TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE |
463 | COMMENTARY FIGURE 915.2(2) COMBINATION WASTE AND VENT COMMENTARY FIGURE 915.2(3) COMBINATION WASTE AND VENT |
464 | COMMENTARY FIGURE 915.2(4) COMBINATION WASTE AND VENT |
465 | COMMENTARY FIGURE 915.2(5) VERTICAL FIXTURE DRAIN COMPONENT IN COMBINATION WASTE AND VENT SYSTEM COMMENTARY FIGURE 915.2.3(1) COMBINATION WASTE AND VENT |
466 | COMMENTARY FIGURE 915.2.3(2) COMBINATION WASTE AND VENT COMMENTARY FIGURE 915.2.3(3) COMBINATION WASTE AND VENT |
467 | COMMENTARY FIGURE 915.2.3(4) COMBINATION WASTE AND VENT COMMENTARY FIGURE 915.2.3(5) COMBINATION WASTE AND VENT |
468 | SECTION 916 ISLAND FIXTURE VENTING COMMENTARY FIGURE 916.2 ISLAND FIXTURE VENT |
469 | SECTION 917 SINGLE-STACK VENT SYSTEM TABLE 917.2 SINGLE STACK SIZE |
470 | COMMENTARY FIGURE 917.3(1) WATER CLOSET WITHIN 18 INCHES OF STACK AND 3-INCH HORIZONTAL BRANCH CONNECTING TO WYE ON STACK COMMENTARY FIGURE 917.3(2) WATER CLOSET WITHIN 18 INCHES OF STACK AND 3-INCH HORIZONTAL BRANCH CONNECTING TO SANITARY TEE ON STACK |
471 | COMMENTARY FIGURE 917.4.1(1) WATER CLOSETS NOT MORE THAN 4 FEET FROM STACK WHEN BRANCH CONNECTS THROUGH WYE TO STACK |
472 | COMMENTARY FIGURE 917.4.1(2) WATER CLOSETS NOT MORE THAN 8 FEET FROM STACK WHEN BRANCH CONNECTS THROUGH SANITARY TEE TO STACK |
473 | COMMENTARY FIGURE 917.4.2 MAXIMUM HORIZONTAL DEVELOPED LENGTH FROM STACK FOR FIXTURES OTHER THAN WATER CLOSETS SECTION 918 AIR ADMITTANCE VALVES |
474 | COMMENTARY FIGURE 917.7 OFFSET VENTING REQUIREMENT FOR SINGLE-STACK VENT SYSTEM |
475 | COMMENTARY FIGURE 917.8 LOWER TWO FLOORS ON SEPARATE STACK COMMENTARY FIGURE 918.3.1(1) AIR ADMITTANCE—INDIVIDUAL VENT COMMENTARY FIGURE 918.3.1(2) COMMON VENT COMMENTARY FIGURE 918.3.1(3) WET VENT |
476 | COMMENTARY FIGURE 918.3.1(4) CIRCUIT VENT COMMENTARY FIGURE 918.3.1(5) BRANCH VENT COMMENTARY FIGURE 918.3.1(6) VENT CONNECTION NOT PERMITTED COMMENTARY FIGURE 918.3.2 PRESSURE IN DRAINAGE STACK |
477 | COMMENTARY FIGURE 918.4 DISTANCE ABOVE DRAIN COMMENTARY FIGURE 918.7 VENT TO THE OPEN AIR REQUIRED |
478 | COMMENTARY FIGURE 918.8(1) PROHIBITED USE OF AIR ADMITTANCE VALVE |
479 | COMMENTARY FIGURE 918.8(2) ONE MANUFACTURER’S ENGINEERED DESIGN FOR USE OF AN AIR ADMITTANCE VALVE ON A SUMP SECTION 919 ENGINEERED VENT SYSTEMS EQUATION 9-1 |
480 | COMMENTARY FIGURE 919.2(1) INDIVIDUAL VENT DEVELOPED LENGTH COMMENTARY FIGURE 919.2(2) EXAMPLE OF ENGINEERED REDUCED-SIZE VENT |
481 | COMMENTARY FIGURE 919.2(3) MAXIMUM LOADS ON MULTIPLE-STORY DRAINAGE STACKS TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES SECTION 920 COMPUTERIZED VENT DESIGN |
482 | BIBLIOGRAPHY |
484 | CHAPTER 10: TRAPS, INTERCEPTORS AND SEPARATORS GENERAL COMMENTS PURPOSE SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS |
485 | COMMENTARY FIGURE 1002.1(1) TRAP REQUIREMENTS |
486 | COMMENTARY FIGURE 1002.1(2) TRAP REQUIREMENTS |
487 | COMMENTARY FIGURE 1002.2 SLIP JOINTS IN TRAPS |
488 | COMMENTARY FIGURE 1002.3 PROHIBITED TRAPS |
489 | COMMENTARY FIGURE 1002.4.1.1 TRAP PRIMER FOR FLOOR DRAINS |
490 | COMMENTARY FIGURE 1002.7 INSTALLATION OF TRAP SECTION 1003 INTERCEPTORS AND SEPARATORS |
491 | COMMENTARY FIGURE 1003.2 INTERCEPTORS AND SEPARATORS |
492 | COMMENTARY FIGURE 1003.3(1) TYPICAL GRAVITY-TYPE GREASE INTERCEPTOR |
493 | COMMENTARY FIGURE 1003.3(2) TYPICAL HYDROMECHANICAL GREASE INTERCEPTOR |
494 | COMMENTARY FIGURE 1003.3.1(1) TYPICAL SINGLE-FIXTURE INSTALLATIONS COMMENTARY FIGURE 1003.3.1(2) GREASE INTERCEPTOR FOR FIXTURES |
495 | COMMENTARY FIGURE 1003.3.1(3) AUTOMATIC GREASE INTERCEPTOR COMMENTARY FIGURE 1003.3.1(4) SENSOR-CONTROLLED GREASE RECOVERY DEVICE |
496 | COMMENTARY FIGURE 1003.3.1(5) BIOREMEDIATION GREASE INTERCEPTOR COMMENTARY FIGURE 1003.3.2 FOOD WASTE DISPOSER CONNECTING TO GREASE INTERCEPTOR |
498 | COMMENTARY FIGURE 1003.3.5 TYPICAL HYDROMECHANICAL GREASE INTERCEPTOR |
501 | TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORSa |
502 | COMMENTARY FIGURE 1003.3.5.2 FLOW CONTROL DEVICE |
503 | COMMENTARY FIGURE 1003.3.7 TYPICAL GRAVITY-TYPE GREASE INTERCEPTOR |
507 | COMMENTARY FIGURE 1003.9 VENTING OF INTERCEPTORS AND SEPARATORS |
508 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS BIBLIOGRAPHY |
510 | CHAPTER 11: STORM DRAINAGE GENERAL COMMENTS PURPOSE SECTION 1101 GENERAL |
512 | COMMENTARY FIGURE 1101.7 ROOF DRAIN WITH SCUPPER OVERFLOW |
513 | SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE |
514 | TABLE 1102.5 SUBSOIL DRAIN PIPE |
515 | TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS COMMENTARY FIGURE 1103.1 TRAPS ON STORM DRAINS THAT CONNECT TO COMBINED SANITARY AND STORM SEWER SYSTEMS |
516 | SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS |
517 | FIGURE 1106.1100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
518 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES |
519 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES |
520 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA |
521 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII |
522 | TABLE 1106.2 STORM DRAIN PIPE SIZING TABLE 1106.3 VERTICAL LEADER SIZING |
523 | COMMENTARY FIGURE 1106.4 VERTICAL WALLS |
524 | TABLE 1106.6 HORIZONTAL GUTTER SIZING SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS |
525 | COMMENTARY FIGURE 1108.1 SECONDARY ROOF DRAINAGE NOT REQUIRED SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS |
526 | COMMENTARY FIGURE 1108.2(1) SEPARATE PRIMARY AND SECONDARY ROOF DRAINS COMMENTARY FIGURE 1108.2(2) PROHIBITED SECONDARY ROOF DRAIN CONNECTION |
527 | COMMENTARY FIGURE 1110.4 MINIMUM NUMBER OF ROOF DRAINS FOR CONTROLLED FLOW SECTION 1111 SUBSOIL DRAINS |
528 | COMMENTARY FIGURE 1111.1(1) SUBSOIL DRAIN SUBJECT TO BACKWATER COMMENTARY FIGURE 1111.1(2) SUBSOIL DRAIN |
529 | SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
530 | BIBLIOGRAPHY |
532 | CHAPTER 12: SPECIAL PIPING AND STORAGE SYSTEMS GENERAL COMMENTS PURPOSE SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES |
533 | SECTION 1203 OXYGEN SYSTEMS |
534 | BIBLIOGRAPHY |
536 | CHAPTER 13: NONPOTABLE WATER SYSTEMS GENERAL COMMENTS PURPOSE SECTION 1301 GENERAL |
537 | FIGURE 1301.3 PICTOGRAPH—DO NOT DRINK |
542 | SECTION 1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS |
544 | TABLE 1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS |
548 | SECTION 1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS |
550 | TABLE 1303.10.1 LOCATION OF RAINWATER STORAGE TANKS |
552 | TABLE 1303.15.8 RAINWATER QUALITY SECTION 1304 RECLAIMED WATER SYSTEMS |
554 | CHAPTER 14: SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS GENERAL COMMENTS PURPOSE SECTION 1401 GENERAL SECTION 1402 SYSTEM DESIGN AND SIZING EQUATION 14-1 |
556 | TABLE 1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM |
557 | SECTION 1403 INSTALLATION TABLE 1403.1.1 DESIGN LOADING RATE |
558 | TABLE 1403.2 DISTRIBUTION PIPE BIBLIOGRAPHY |
560 | CHAPTER 15: REFERENCED STANDARDS GENERAL COMMENTS PURPOSE |
561 | COMMENTARY FIGURE 15 REFERENCED STANDARD ANSI |
562 | ASHRAE ASME |
564 | ASPE ASSE |
566 | ASTM |
571 | AWS AWWA |
572 | CISPI CSA |
574 | IAPMO |
575 | ICC ISEA MSS |
576 | NFPA NGWA NSF |
577 | PDI PSAI UL |
578 | APPENDIX A: PLUMBING PERMIT FEE SCHEDULE GENERAL COMMENTS PURPOSE |
580 | APPENDIX B: RATES OF RAINFALL FOR VARIOUS CITIES GENERAL COMMENTS PURPOSE |
582 | APPENDIX C: STRUCTURAL SAFETY GENERAL COMMENTS PURPOSE SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS COMMENTARY FIGURE C101.1 CUTTING, NOTCHING AND BORING JOISTS |
583 | COMMENTARY FIGURE C101.2 CUTTING, NOTCHING AND BORED HOLES |
584 | APPENDIX D: DEGREE DAY AND DESIGN TEMPERATURES GENERAL COMMENTS PURPOSE LOAD CALCULATIONS PIPING INSULATION PROTECTION OF VENT TERMINALS |
585 | TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
586 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
587 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
588 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
589 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
590 | BIBLIOGRAPHY |
592 | APPENDIX E: SIZING OF WATER PIPING SYSTEM GENERAL COMMENTS PURPOSE SECTION E101 GENERAL SECTION E102 INFORMATION REQUIRED |
593 | SECTION E103 SELECTION OF PIPE SIZE |
598 | TABLE E.1 TABLE E.2 |
599 | FIGURE E103.3(1) EXAMPLE-SIZING |
600 | TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS |
601 | TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa |
602 | TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND |
603 | TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi) |
604 | TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet) TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet) |
605 | FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING) |
606 | FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING) |
607 | FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING) |
608 | FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa |
609 | FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa |
610 | FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa |
611 | SECTION E201 SELECTION OF PIPE SIZE SECTION E202 DETERMINATION OF PIPE VOLUMES |
612 | TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
613 | TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.) |
614 | TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
616 | INDEX |
628 | ICC MEMBERSHIP |
629 | ICC EVALUATION SERVICE |
630 | ICC ASSESSMENT CENTER |
631 | VALUABLE GUIDES TO CHANGES IN THE 2018 I-CODES® |