ICC SignificantChangestotheMPFC 2021
$30.20
Significant Changes to the IPC®, IMC®, and IFGC®, 2021 Edition
Published By | Publication Date | Number of Pages |
ICC | 2021 |
Gain full access to the most critical updates to the International Plumbing Code®, International Mechanical Code® and International Fuel Gas Code®, the real world application of those changes, and why they originated—all in a single easy-to-use resource. Significant Changes to the International Plumbing Code®, International Mechanical Code®, and International Fuel Gas Code® 2021 Edition provides a comprehensive analysis of the significant changes in the new editions of these codes, offering key insights into the implications of those changes. Each change analysis features the affected code sections and identifies the change as newly added text, a modification or clarification of the existing language or deleted text. Accompanying each change is a photograph, detailed illustration or comprehensive example to assist and enhance reader understanding. The book’s attention to detail, its logical organization, and its thorough yet concise coverage all make it an ideal tool for transitioning from the 2018 to the 2021 editions of the International Plumbing Code®, International Mechanical Code®, and International Fuel Gas Code®.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2021 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE®, INTERNATIONAL MECHANICAL CODE®, INTERNATIONAL FUEL GAS CODE® |
2 | 2021 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE®, INTERNATIONAL MECHANICAL CODE®, INTERNATIONAL FUEL GAS CODE® TITLE PAGE |
3 | COPYRIGHT |
4 | CONTENTS |
8 | PREFACE |
12 | SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE® |
13 | PART 1: INTERNATIONAL PLUMBING CODE CHAPTERS 1 THROUGH 15 |
16 | 202 DEFINITION OF COPPER ALLOY |
17 | 202 DEFINITION OF PUBLIC AND PRIVATE FIGURE: PUBLIC VERSUS PRIVATE USES |
18 | 202 DEFINITION OF WATER DISPENSER IMAGE: BOTTLED WATER UNIT IS NOT A WATER DISPENSER |
19 | 308.9 BUNDLED HOT WATER PIPING INSULATION FIGURE: HOT WATER PIPING BUNDLED WITH COLD WATER PIPING |
20 | 403.1.1 FIXTURE QUANTITY CALCULATIONS FOR MULTIPLE USER FACILITIES |
22 | 403.1.2 FIXTURES IN SINGLE-USER TOILET ROOMS COUNT TOWARDS TOTAL REQUIRED QUANTITIES IMAGE: FIXTURES IN ALL SINGLE-USER TOILET ROOMS COUNT TOWARD TOTAL REQUIRED |
24 | 403.2 MULTIPLE-USER NONSEPARATED TOILET FACILITIES FIGURE: MULTIPLE-USER NONSEPARATED TOILET FACILITIES |
26 | 403.3.1, 403.5 FACILITIES AND DRINKING FOUNTAINS ON ACCESSIBLE ROUTES FIGURE: ACCESSIBLE ROUTES |
27 | 403.3.3 GROUP S TOILET FACILITY LOCATION FIGURE: STORAGE FACILITY WITH TOILET FACILITY AT OFFICE |
29 | 403.6 SERVICE SINK LOCATION FIGURE: LOCATION OF SERVICE SINK |
30 | 405.4.3 WALL HUNG FIXTURE CARRIER STANDARD FOR WATER CLOSETS FIGURE: WALL-HUNG WATER CLOSET CARRIER |
31 | 407.2 BATHTUBS ARE NOT REQUIRED TO HAVE OVERFLOW OUTLETS FIGURE: OVERFLOW NOT REQUIRED |
32 | 410.3.2 QUANTITIES OF STANDING VERSUS WHEELCHAIR DRINKING FOUNTAINS FIGURE: DRINKING FOUNTAINS FOR ACCESSIBLE DESIGN |
34 | 410.4 DRINKING FOUNTAIN SUBSTITUTION USING WATER DISPENSERS IMAGE: DRINKING FOUNTAIN SUBSTITUTION USING WATER DISPENSERS |
35 | 411.3 WATER HEATERS FOR EMERGENCY SHOWERS AND EYE WASH STATIONS IMAGE: EMERGENCY SHOWER WATER HEATER |
36 | 412.3 SHOWER CONTROL VALVES TO BE RATED FOR THE INSTALLED SHOWER HEAD IMAGE: SHOWER VALVE RATED FOR LOWER FLOW SHOWER HEAD |
37 | 412.5 METHODS FOR LIMITING WATER TEMPERATURE DISCHARGED TO BATHTUBS FIGURE: TEMPERATURE LIMITING FOR BATHTUBS |
38 | 412.10 METHODS FOR TEMPERATURE LIMITATION AT HEAD SHAMPOO SINKS AND FOOTBATHS IMAGE: TEMPERATURE LIMITING FOR HEAD SHAMPOO SINKS |
39 | 419.5 TEMPERED WATER FOR PUBLIC HAND-WASHING LAVATORIES IMAGE: A CSA B125.3 DEVICE IS NO LONGER ACCEPTABLE FOR TEMPERATURE COMPENSATING |
40 | 421.3.1 STANDARD FOR SHOWER WASTE FITTINGS IMAGE: SHOWER DRAIN TO COMPLY WITH STANDARD |
41 | 501.2 ASSE 1017 TEMPERATURE ACTUATED MIXING VALVES IMAGE: “MASTER THERMOSTATIC” MIXING VALVE DOES NOT EXIST |
42 | 602.3.5 POTABLE WATER PUMPS TO COMPLY WITH NSF 61 IMAGE: NSF 61-COMPLIANT POTABLE WATER PUMP |
43 | 605.1.12.3, 605.13.6 SOLDER AND FLUX TO CONFORM TO NSF 61 IMAGE: NSF 61-COMPLIANT SOLDER AND FLUX |
44 | 606.1 INDIVIDUAL TENANT WATER SHUT-OFF VALVE FIGURE: INDIVIDUAL TENANT SHUT-OFF VALVES |
45 | 607.1.1, 607.1.2 WATER HEATERS PROVIDING TEMPERED WATER TO FIXTURES IMAGE: WATER HEATER FOR TEMPERED WATER |
46 | 608.15.2.1 DISCHARGE FROM BACKFLOW PREVENTER RELIEF OPENING IMAGE; WASTE RECEPTOR FOR BACKFLOW PREVENTER |
47 | 608.17.2 BACKFLOW DEVICE FOR LOW HAZARD BOILER APPLICATIONS IMAGE: PRESSURE REDUCING VALVE/BACKFLOW PREVENTER FOR BOILER |
48 | 609.2 TWO WATER SERVICE PIPES FOR GROUP I-2, CONDITION 2 HEALTHCARE FACILITIES IMAGE: HEALTHCARE FACILITY WATER SERVICE PIPES |
49 | 609.2.1 TRACER WIRE FOR BURIED NONMETALLIC WATER SERVICE PIPING IMAGE: TRACER REQUIRED FOR UNDERGROUND NONMETALLIC WATER SERVICE PIPE |
50 | TABLE 702.3 ABS BUILDING SEWER PIPE STANDARD IMAGE: NEW STANDARD FOR ABS SEWER PIPE |
51 | 705.2.4, 705.10.4 PVC AND ABS PUSH-FIT DWV FITTINGS IMAGE: PUSH-FIT DRAINAGE FITTINGS |
52 | 708.1.6 REMOVABLE FIXTURE TRAPS SERVING AS CLEANOUTS IMAGE: REMOVABLE TRAP AS CLEANOUT |
53 | 717, 718 METHODS FOR RESTORING BUILDING SEWER PIPING |
54 | IMAGE: BUILDING SEWER RESTORATION |
56 | 903.1.3 PROTECTED OUTDOOR VENT TERMINATION METHOD IMAGE: ARCHITECTURAL SHROUD |
57 | 915.1 FOOD WASTE DISPOSERS ON COMBINATION WASTE AND VENT SYSTEMS IMAGE: FOOD WASTE DISPOSER ON CWV SYSTEM |
58 | 1002.1 DIRECT CONNECTION TO HYDROMECHANICAL GREASE INTERCEPTOR IMAGE: DIRECT CONNECTION TO HYDROMECHANICAL INTERCEPTOR PERMITTED |
60 | 1002.4.1.5 FIXTURE DRAINS SERVING AS A TRAP PRIMING METHOD IMAGE: FIXTURE DRAIN PERMITTED TO SERVE AS TRAP PRIMING METHOD |
61 | 1102.6 ROOF DRAINS TO BE TESTED AND RATED FOR FLOW IMAGE: PRODUCT TESTING AND RATING FOR FLOW REQUIRED |
62 | 1106.2.1 RAINFALL RATE CONVERSION METHOD EQUATION 11-1 IMAGE: A NEW EQUATION CONVERTS INCHES PER HOUR OF RAINFALL TO GALLONS PER MINUTE FLOW RATE |
63 | 1202.1 NONFLAMMABLE MEDICAL GAS SYSTEMS IMAGE: NONFLAMMABLE MEDICAL GAS SYSTEM INSTALLATION |
64 | 1301.1 NONPOTABLE RAINWATER STANDARD ALTERNATIVE IMAGE: RAINWATER STORAGE SYSTEM |
66 | SIGNIFICANT CHANGES TO THE INTERNATIONAL MECHANICAL CODE® |
67 | PART 2: INTERNATIONAL MECHANICAL CODE CHAPTERS 1 THROUGH 15 |
69 | 307.2.1.1 CONDENSATE DISCHARGE FIGURE: ALLOWABLE RECEPTORS FOR CONDENSATE |
71 | 401.2, 403.1 MECHANICAL VENTILATION FOR DWELLING UNITS IMAGE: GROUP R-2 APARTMENT BUILDING |
73 | 401.4, 501.3.1 INTAKE OPENING AND EXHAUST OUTLET LOCATIONS |
74 | IMAGE: COMBINATION EXHAUST AND INTAKE AIR FITTING |
75 | TABLE 403.3.1.1 RECIRCULATION OF MECHANICAL EXHAUST PROHIBITED FIGURE: WHEEL-TYPE ENERGY RECOVERY VENTILATION |
77 | 403.3.1.3 DEMAND CONTROLLED VENTILATION |
78 | 403.3.2.1 OUTDOOR AIR FOR DWELLING UNITS EQUATION 4-9 |
80 | 502.20 MANICURE AND PEDICURE STATION EXHAUST SYSTEM IMAGE: MANICURE AND PEDICURE STATION EXHAUST SYSTEM IMAGE: MANICURE AND PEDICURE STATIONS |
82 | 504.4.1 TERMINATION LOCATION FOR DRYER EXHAUST FIGURE: DRYER EXHAUST TERMINAL MINIMUM CLEARANCE TO OPERABLE OPENINGS AND SOFFIT VENTS |
83 | 506.3.7 FACTORY-BUILT GREASE DUCT SLOPE IMAGE: GREASE DUCT |
84 | IMAGE: GREASE DUCT |
85 | 507.1 SMOKER OVENS WITH INTEGRAL EXHAUST IMAGE: SMOKER OVEN WITH INTEGRAL EXHAUST |
86 | IMAGE: SMOKER OVEN WITH INTEGRAL EXHAUST |
88 | 514.2 ENERGY RECOVERY VENTILATION SYSTEMS IMAGE: COMMERCIAL KITCHEN OVENS |
89 | IMAGE: COMMERCIAL KITCHEN OVENS |
90 | 602.2.1.8 PIPE AND DUCT INSULATION WITHIN PLENUMS IMAGE: PIPE INSULATION |
91 | IMAGE: DUCT INSULATION |
92 | 607.5.2 DUCT PENETRATIONS OF FIRE BARRIERS |
93 | FIGURE: DUCT PENETRATION OF FIRE BARRIER |
95 | 607.5.5 SUBDUCTS PENETRATING SHAFT ENCLOSURES FIGURE: SUBDUCTS PENETRATING SHAFT ENCLOSURES |
97 | 608.1, 403.3.1.5 VENTILATION AIR DISTRIBUTION IMAGE: MEANS TO ADJUST AIRFLOW TO BALANCE VENTILATION AIR DISTRIBUTION |
98 | 801.21 BLOCKED VENT SWITCH FOR OIL-FIRED APPLIANCES FIGURE: BLOCKED VENT SWITCH FOR OIL-FIRED APPLIANCES |
99 | 905.1 WOOD-BURNING RESIDENTIAL HYDRONIC HEATERS FIGURE: WOOD-BURNING RESIDENTIAL HYDRONIC HEATER |
100 | 929 UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCES IMAGE: UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCE |
101 | 1101 THROUGH 1108 AMMONIA REFRIGERATION SYSTEMS IMAGE: AMMONIA REFRIGERATION SYSTEMS |
102 | TABLE 103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
104 | 1105.9 MACHINERY ROOM MEANS OF EGRESS FIGURE: MACHINERY ROOM MEANS OF EGRESS |
105 | IMAGE: MACHINERY ROOM EGRESS DOOR |
106 | 1107 THROUGH 1110 REFRIGERANT PIPING IMAGE: REFRIGERATION PIPING |
107 | TABLE 1107.4 REFRIGERANT PIPE TABLE 1107.5 REFRIGERANT PIPE FITTINGS TABLE 1107.5.1 COPPER BRAZED SWAGED CUP DEPTHS |
108 | TABLE 1109.3.2 SHAFT VENTILATION VELOCITY |
109 | IMAGE: COPPER REFRIGERATION PIPING |
112 | SIGNIFICANT CHANGES TO THE INTERNATIONAL FUEL GAS CODE® |
113 | PART 3: INTERNATIONAL FUEL GAS CODE CHAPTERS 1 THROUGH 8 |
115 | 202 DEFINITION OF POINT OF DELIVERY FIGURE: SERVICE METER ASSEMBLY AND POINT OF DELIVERY |
117 | 307.2 CONCEALED CONDENSATE PIPING FIGURE: LABELING OF CONCEALED CONDENSATE PIPING TERMINATION |
119 | 402.7, 202 PRESS-CONNECT JOINT IMAGE: PRESS-CONNECT FITTING WITH BITE RING USED WITH SCH 40 AND SCH 10 STEEL PIPE |
120 | 403.8.3 THREADED JOINT SEALING IMAGE: THREADED JOINT PIPE TAPE |
121 | 404.5 FITTINGS IN CONCEALED LOCATIONS IMAGE: THREADED FITTING PERMITTED IN CONCEALED SPACES |
122 | 503.5.6.1 CHIMNEY LINING FIGURE: CODE-COMPLIANT CHIMNEY LINING REQUIRED FOR REPLACEMENT APPLIANCE |
124 | 503.8 VENTING SYSTEM TERMINAL CLEARANCES |
125 | FIGURE 503.8 THROUGH THE WALL VENT TERMINAL CLEARANCES |
126 | TABLE 503.8 THROUGH-THE-WALL VENT TERMINAL CLEARANCES |
128 | 503.10.7 VENT CONNECTOR JUNCTIONS |
129 | FIGURE: VENT CONNECTORS JOINED BY TEE OR WYE FITTINGS |
130 | 614.7 CLOTHES DRYER MAKEUP AIR FIGURE: MAKEUP AIR FOR A CLOSET INSTALLATION OF A DRYER |
131 | 618.6 RETURN AIR FROM MECHANICAL ROOM FIGURE: PROHIBITED INSTALLATION |
133 | 623.2 COMMERCIAL COOKING APPLIANCES IMAGE: COMMERCIAL-TYPE DOMESTIC RANGE |
136 | TELEWORK WITH ICC DIGITAL CODES PREMIUM |
137 | PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™) |