IFC® Code and Commentary 2021
$15.60
IFC® Code and Commentary
Published By | Publication Date | Number of Pages |
ICC | 2021 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2021 IFC® CODE AND COMMENTARY VOLUME 1 |
2 | 2021 IFC® CODE AND COMMENTARY VOLUME 1 TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
6 | ARRANGEMENT AND FORMAT OF THE 2021 IFC |
8 | TABLE OF CONTENTS |
10 | PART I—ADMINISTRATIVE CHAPTER 1: SCOPE AND ADMINISTRATION GENERAL COMMENTS COMMENTARY FIGURE 1(1) ASPECTS OF CODE ENFORCEMENT CODE ADMINISTRATIVE ENVIRONMENT |
11 | SCOPE AND APPLICABILITY OF THE CODE RETROACTIVITY OTHER CODES AND STANDARDS FIRE CODE OFFICIAL’S JUDGMENT APPROVAL COMMENTARY FIGURE 1(2) SYSTEMS APPROACHES TO CODE COMPLIANCE |
12 | FIRE CODE OFFICIALS AND LIABILITY COMMENTARY FIGURE 1(3) TYPES OF TORTS |
13 | COMMENTARY FIGURE 1(4) MARKMAN’S SIX RULES ENFORCEMENT INSPECTION |
14 | DETECTION COMMENTARY FIGURE 1(5) HOW BUILDINGS, PEOPLE AND FIRE INTERACT NOTIFICATION REPORTING |
15 | COMMENTARY FIGURE 1(6) NORMAL PLANNING APPROACH PURPOSE |
16 | PART 1—GENERAL PROVISIONS SECTION 101 SCOPE AND GENERAL REQUIREMENTS |
17 | SECTION 102 APPLICABILITY |
20 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 CODE COMPLIANCE AGENCY SECTION 104 DUTIES AND POWERS OF THE FIRE CODE OFFICIAL |
21 | COMMENTARY FIGURE 104.4 PERSONNEL IDENTIFICATION BADGE |
25 | SECTION 105 PERMITS |
29 | TABLE 105.5.9 PERMIT AMOUNTS FOR COMPRESSED GASES TABLE 105.5.11 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS |
31 | TABLE 105.5.22 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS |
32 | TABLE 105.5.22—continued PERMIT AMOUNTS FOR HAZARDOUS MATERIALS |
37 | SECTION 106 CONSTRUCTION DOCUMENTS |
38 | SECTION 107 FEES |
39 | SECTION 108 INSPECTIONS |
41 | SECTION 109 MAINTENANCE |
42 | SECTION 110 SERVICE UTILITIES SECTION 111 MEANS OF APPEALS |
43 | SECTION 112 VIOLATIONS |
44 | SECTION 113 STOP WORK ORDER |
45 | SECTION 114 UNSAFE STRUCTURES OR EQUIPMENT |
46 | BIBLIOGRAPHY |
48 | CHAPTER 2: DEFINITIONS GENERAL COMMENTS PURPOSE SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
52 | COMMENTARY FIGURE 202-A1 EXAMPLE OF AIR-INFLATED MEMBRANE STRUCTURE COMMENTARY FIGURE 202-A2 AIR-SUPPORTED MEMBRANE STRUCTURE—SWIMMING POOL COVER |
53 | COMMENTARY FIGURE 202-A3 AISLES AND AISLE ACCESSWAYS |
54 | COMMENTARY FIGURE 202-A4 PROPERTIES OF FUEL ETHANOL |
58 | COMMENTARY FIGURE 202-B1 BALANCED DOOR COMMENTARY FIGURE 202-B2 ARRANGEMENT OF BARRICADE |
62 | COMMENTARY FIGURE 202-C1 EXAMPLE OF A FREE-STANDING MEMBRANE-COVERED CANOPY |
63 | COMMENTARY FIGURE 202-C2 EXAMPLE OF A CANOPY SUPPORTED BY A BUILDING AND STANCHION COMMENTARY FIGURE 202-C3 EXAMPLE OF A FREE-STANDING MOTOR FUEL-DISPENSING FACILITY CANOPY |
73 | COMMENTARY FIGURE 202-D1 TYPICAL DIP TANK INSTALLATION |
75 | COMMENTARY FIGURE 202-D2 EXAMPLE OF DRAFTSTOPPING COMMENTARY FIGURE 202-D3 EXAMPLE OF DRAFTSTOPPING |
80 | COMMENTARY FIGURE 202-E1 EXIT |
81 | COMMENTARY FIGURE 202-E2 EXIT ACCESS COMMENTARY FIGURE 202-E3 EXIT DISCHARGE |
82 | COMMENTARY FIGURE 202-E4 EXIT DISCHARGE, LEVEL OF |
83 | COMMENTARY FIGURE 202-E5 COMPARISON OF CLASSIFICATION SYSTEMS FOR EXPLOSIVE MATERIALS |
89 | COMMENTARY FIGURE 202-F1 EXAMPLES OF FIRE-RESISTANT JOINT SYSTEMS |
91 | COMMENTARY FIGURE 202-F2 FLAMMABLE SOLID TEST METHOD |
92 | COMMENTARY FIGURE 202-F3 MELTING AND IGNITION TEMPERATURES OF SELECTED PURE METALS IN SOLID FORM |
93 | COMMENTARY FIGURE 202-F4 COMMON FLAMMABLE SOLIDS AND THEIR PROPERTIES |
94 | COMMENTARY FIGURE 202-F5 FLUE SPACES |
99 | COMMENTARY FIGURE 202-H1 HAZARDOUS PRODUCTION MATERIALS (HPM) USED IN THE MANUFACTURE OF SEMICONDUCTORS |
101 | COMMENTARY FIGURE 202-H2 COMMON HIGHLY TOXIC MATERIALS AND THEIR HAZARDS |
102 | COMMENTARY FIGURE 202-H3 HIGH-RISE BUILDING |
104 | COMMENTARY FIGURE 202-H4 HORIZONTAL EXIT COMMENTARY FIGURE 202-H5 TYPICAL WELDING CART |
109 | COMMENTARY FIGURE 202-L1 LIQUID OXYGEN AMBULATORY CONTAINER COMMENTARY FIGURE 202-L2 LIQUID OXYGEN HOME CARE CONTAINER |
114 | COMMENTARY FIGURE 202-M1 METAL HYDRIDE STORAGE CONTAINER AND ITS METAL HYDRIDE CONTENT |
115 | COMMENTARY FIGURE 202-N1 NESTING OF CYLINDERS |
117 | COMMENTARY FIGURE 202-O1 GROUP A-1 |
118 | COMMENTARY FIGURE 202-O2 GROUP A-1 COMMENTARY FIGURE 202-O3 GROUP A-2 |
121 | COMMENTARY FIGURE 202-O4 ACCESSORY ASSEMBLY USE LIMITED BY OCCUPANT LOAD COMMENTARY FIGURE 202-O5 ACCESSORY ASSEMBLY USE GREATER THAN 10 PERCENT OF FLOOR AREA BUT LESS THAN 750 FT2 |
146 | COMMENTARY FIGURE 202-O6 COMPARISON OF HYDROGEN PEROXIDE STRUCTURE WITH BENZOYL PEROXIDE COMMENTARY FIGURE 202-O7 COMPARISON OF ORGANIC PEROXIDE CLASSIFICATION SYSTEMS |
151 | COMMENTARY FIGURE 202-P1 INSULATED HORIZONTAL PRESSURE VESSEL COMMENTARY FIGURE 202-P2 VERTICAL PRESSURE VESSEL |
156 | COMMENTARY FIGURE 202-S1 TYPE I SAFETY CAN COMMENTARY FIGURE 202-S2 TYPE II SAFETY CAN |
157 | COMMENTARY FIGURE 202-S3 TYPICAL COMPONENTS OF AN HPM FACILITY |
162 | COMMENTARY FIGURE 202-S4 TYPICAL PAINT SPRAY BOOTH |
167 | COMMENTARY FIGURE 202-T1 EXAMPLE OF TENT STRUCTURE |
169 | COMMENTARY FIGURE 202-T2 SPEED PILLOW TRAFFIC CALMING DEVICE COMMENTARY FIGURE 202-T3 ROUNDABOUT TRAFFIC CALMING DEVICE |
170 | COMMENTARY FIGURE 202-T4 TUBE TRAILER |
171 | COMMENTARY FIGURE 202-U1 UMBRELLA STRUCTURE |
173 | BIBLIOGRAPHY |
174 | PART II—GENERAL SAFETY PROVISIONS CHAPTER 3: GENERAL REQUIREMENTS GENERAL COMMENTS COMMENTARY FIGURE 3 THE FIRE SAFETY CONCEPTS TREE PURPOSE |
175 | SECTION 301 GENERAL SECTION 302 DEFINITIONS SECTION 303 ASPHALT KETTLES |
176 | SECTION 304 COMBUSTIBLE WASTE MATERIAL |
179 | SECTION 305 IGNITION SOURCES SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM |
180 | SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES |
182 | SECTION 308 OPEN FLAMES |
186 | SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT COMMENTARY FIGURE 309.2 BATTERY CHARGERS FOR POWERED INDUSTRIAL TRUCKS |
187 | SECTION 310 SMOKING COMMENTARY FIGURE 310.3 NO SMOKING SIGN |
188 | SECTION 311 VACANT PREMISES |
191 | SECTION 312 VEHICLE IMPACT PROTECTION COMMENTARY FIGURE 312.2(1) PUMP ISLAND PROTECTION |
192 | COMMENTARY FIGURE 312.2(2) GUARD POST INSTALLATION IN PUBLIC REPAIR GARAGE COMMENTARY FIGURE 312.3 ONE METHOD OF EQUIPMENT PROTECTION SECTION 313 FUELED EQUIPMENT |
193 | SECTION 314 INDOOR DISPLAYS |
194 | COMMENTARY FIGURE 314.4 INDOOR CAR DISPLAY SECTION 315 GENERAL STORAGE |
197 | COMMENTARY FIGURE 315.6 ABANDONED DATA CABLE IN A PLENUM |
198 | TABLE 315.7.6(1) SEPARATION DISTANCE BETWEEN WOOD PALLET STACKS AND BUILDINGS TABLE 315.7.6(2) SEPARATION DISTANCE BETWEEN PLASTIC PALLET STACKS AND BUILDINGS TABLE 315.7.6(3) SEPARATION FROM OTHER PALLET PILES AND ON-SITE STORAGE (WOOD PALLETS) TABLE 315.7.6(4) SEPARATION FROM OTHER PALLET PILES AND ON-SITE STORAGE (PLASTIC PALLETS) |
199 | SECTION 316 HAZARDS TO FIRE FIGHTERS COMMENTARY FIGURE 316.2.1 SHAFTWAY SIGNAGE |
201 | SECTION 317 LANDSCAPED ROOFS |
202 | SECTION 318 LAUNDRY CARTS |
203 | SECTION 319 MOBILE FOOD PREPARATION VEHICLES |
206 | SECTION 320 ADDITIVE MANUFACTURING (3D PRINTING) |
208 | SECTION 321 ARTIFICIAL COMBUSTIBLE VEGETATION BIBLIOGRAPHY |
210 | CHAPTER 4: EMERGENCY PLANNING AND PREPAREDNESS GENERAL COMMENTS PURPOSE MANAGING FIRE MANAGING OCCUPANTS |
211 | LIFE SAFETY |
212 | SECTION 401 GENERAL |
213 | SECTION 402 DEFINITIONS SECTION 403 EMERGENCY PREPAREDNESS REQUIREMENTS |
220 | COMMENTARY FIGURE 403.7.3.6 TACTILE CODING OF INSTITUTIONAL KEYS |
227 | SECTION 404 FIRE SAFETY, EVACUATION AND LOCKDOWN PLANS |
230 | SECTION 405 EMERGENCY EVACUATION DRILLS |
231 | TABLE 405.3 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION |
233 | SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES |
234 | SECTION 407 HAZARD COMMUNICATION |
235 | BIBLIOGRAPHY |
236 | PART III—BUILDING AND EQUIPMENT DESIGN FEATURES CHAPTER 5: FIRE SERVICE FEATURES GENERAL COMMENTS PURPOSE SECTION 501 GENERAL |
237 | SECTION 502 DEFINITIONS SECTION 503 FIRE APPARATUS ACCESS ROADS COMMENTARY FIGURE 503.1.1(1) FIRE DEPARTMENT ACCESS—LARGE BUILDING |
238 | COMMENTARY FIGURE 503.1.1(2) FIRE DEPARTMENT ACCESS ON TWO SIDES COMMENTARY FIGURE 503.1.1(3) SMALL BUILDING ACCESS |
241 | COMMENTARY FIGURE 503.2.8 EXAMPLE OF ANGLES OF APPROACH AND DEPARTURE |
242 | SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS |
243 | SECTION 505 PREMISES IDENTIFICATION SECTION 506 KEY BOXES |
244 | COMMENTARY FIGURE 506.1(1) SURFACE-MOUNTED KEY BOX COMMENTARY FIGURE 506.1(2) RECESSED-MOUNTED KEY BOX |
245 | SECTION 507 FIRE PROTECTION WATER SUPPLIES |
246 | COMMENTARY FIGURE 507.5.1(1) HYDRANT LAYOUT TO MINIMIZE HOSE RUN COMMENTARY FIGURE 507.5.1(2) HYDRANT LOCATION—GROUPS R-3 AND U OCCUPANCIES |
247 | COMMENTARY FIGURE 507.5.1(3) ACCEPTABLE HYDRANT LOCATION WITH SPRINKLERS |
248 | COMMENTARY FIGURE 507.5.5 HYDRANT CLEARANCE COMMENTARY FIGURE 507.5.6 HYDRANT IMPACT PROTECTION SECTION 508 FIRE COMMAND CENTER |
251 | SECTION 509 FIRE PROTECTION AND UTILITY EQUIPMENT IDENTIFICATION AND ACCESS |
252 | SECTION 510 EMERGENCY RESPONDER COMMUNICATION COVERAGE |
258 | BIBLIOGRAPHY |
260 | CHAPTER 6: BUILDING SERVICES AND SYSTEMS GENERAL COMMENTS PURPOSE SECTION 601 GENERAL SECTION 602 DEFINITIONS |
261 | SECTION 603 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS |
262 | COMMENTARY FIGURE 603.4 REQUIRED CLEARANCES COMMENTARY FIGURE 603.5 TYPICAL CURRENT TAP AND RELOCATABLE POWER TAP |
264 | COMMENTARY FIGURE 603.6 EXAMPLES OF UNACCEPTABLE PRACTICES |
266 | COMMENTARY FIGURE 603.10 ABANDONED WIRING IN PLENUM SECTION 604 ELEVATOR OPERATION, MAINTENANCE AND FIRE SERVICE KEYS |
268 | COMMENTARY FIGURE 604.6.1 TYPICAL ELEVATOR KEY BOX |
269 | SECTION 605 FUEL-FIRED APPLIANCES |
275 | COMMENTARY FIGURE 605.5.2 PORTABLE OUTDOOR GAS-FIRED HEATING APPLIANCE/PATIO HEATER |
277 | SECTION 606 COMMERCIAL COOKING EQUIPMENT AND SYSTEMS |
280 | TABLE 606.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY |
281 | SECTION 607 COMMERCIAL COOKING OIL STORAGE |
282 | COMMENTARY FIGURE 607.1 COOKING OIL FLASH POINT AND IGNITION TEMPERATURES COMMENTARY FIGURE 607.2 COOKING OIL STORAGE TANK AND RECOVERY CART |
283 | SECTION 608 MECHANICAL REFRIGERATION |
290 | [M] TABLE 608.18.2 MINIMUM EXHAUST RATE |
291 | EQUATION 1 EQUATION 2 SECTION 609 HYPERBARIC FACILITIES SECTION 610 CLOTHES DRYER EXHAUST SYSTEMS |
292 | BIBLIOGRAPHY |
294 | CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES GENERAL COMMENTS PURPOSE SECTION 701 GENERAL |
296 | SECTION 702 DEFINITIONS |
297 | SECTION 703 PENETRATIONS SECTION 704 JOINTS AND VOIDS |
298 | SECTION 705 DOOR AND WINDOW OPENINGS |
299 | SECTION 706 DUCT AND AIR TRANSFER OPENINGS |
300 | SECTION 707 CONCEALED SPACES SECTION 708 SPRAY FIRE-RESISTANT MATERIALS AND INTUMESCENT FIRE-RESISTANT MATERIALS BIBLIOGRAPHY |
302 | CHAPTER 8: INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS GENERAL COMMENTS PURPOSE SECTION 801 GENERAL SECTION 802 DEFINITIONS |
303 | SECTION 803 INTERIOR WALL AND CEILING FINISH IN EXISTING BUILDINGS COMMENTARY FIGURE 803.1.1(1) ROOM CORNER TEST |
304 | COMMENTARY FIGURE 803.1.1(2) FLAME IN ROOM CORNER TEST COMMENTARY FIGURE 803.1.2(1) ASTM E84 TUNNEL TEST |
305 | COMMENTARY FIGURE 803.1.2(2) FLAME IN TUNNEL TEST COMMENTARY FIGURE 803.1.2(3) TYPICAL FLAME SPREAD OF COMMON MATERIALS |
307 | TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk |
308 | COMMENTARY FIGURE 803.4 APPLIED FLAME-RETARDANT COATINGS |
312 | SECTION 804 INTERIOR WALL AND CEILING TRIM AND INTERIOR FLOOR FINISH IN NEW AND EXISTING BUILDINGS |
313 | COMMENTARY FIGURE 804.2.2 MAXIMUM DIMENSIONS—FOAM PLASTIC TRIM COMMENTARY FIGURE 804.2.3 FOAM PLASTIC DECORATIVE TRIM COVERAGE AREA |
314 | COMMENTARY FIGURE 804.3.1 RADIANT FLOOR PANEL TEST |
315 | SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS COMMENTARY FIGURE 805.1 EFFECT OF LOCATION OF FIRE |
317 | COMMENTARY FIGURE 805.1.1.2(1) TYPICAL FIRE TEST SETUP COMMENTARY FIGURE 805.1.1.2(2) STEADY VERSUS UNSTEADY FIRES |
320 | COMMENTARY FIGURE 805.3.2.2.2 ANNEX A3 ASTM F1085 TEST RESULTS |
322 | SECTION 806 NATURAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS |
323 | COMMENTARY FIGURE 806.1(1) SUMMARY OF TREE PARAMETERS COMMENTARY FIGURE 806.1(2) GRAPH OF HEAT RELEASE RATE VERSUS TIME FOR TEST NUMBER 3 |
324 | SECTION 807 DECORATIVE MATERIALS AND ARTIFICIAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS |
328 | COMMENTARY FIGURE 807.5.2.2 ARTWORK COVERAGE AREA EXAMPLE |
330 | SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS |
331 | BIBLIOGRAPHY |
332 | CHAPTER 9: FIRE PROTECTION AND LIFE SAFETY SYSTEMS GENERAL COMMENTS PURPOSE SECTION 901 GENERAL |
336 | TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS |
340 | SECTION 902 DEFINITIONS SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
342 | COMMENTARY FIGURE 903.2 SUMMARY OF OCCUPANCY-RELATED AUTOMATIC SPRINKLER THRESHOLDSa |
348 | TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
353 | COMMENTARY FIGURE 903.2.11.1 SPACING OF OPENINGS IN STORIES OR BASEMENTS |
354 | COMMENTARY FIGURE 903.2.11.1.2(1) OPENINGS IN STORIES OR BASEMENTS Less than 75 feet from any point to an opening COMMENTARY FIGURE 903.2.11.1.2(2) OPENINGS IN STORIES OR BASEMENTS Greater than 75 feet from any point to an opening |
355 | COMMENTARY FIGURE 903.2.11.1.2(3) OPENINGS IN STORIES OR BASEMENTS Less than 75 feet from any point to an opening COMMENTARY FIGURE 903.2.11.1.2(4) OPENINGS IN STORIES OR BASEMENTS |
356 | COMMENTARY FIGURE 903.2.11.3 SPRINKLER REQUIREMENTS: OCCUPANTS 55 FEET OR GREATER FROM FIRE DEPARTMENT VEHICLE ACCESS |
357 | TABLE 903.2.11.6 ADDITIONAL REQUIRED FIRE PROTECTION SYSTEMS TABLE 903.2.11.6—continued ADDITIONAL REQUIRED FIRE PROTECTION SYSTEMS |
360 | COMMENTARY FIGURE 903.3 SAMPLE SPRINKLER SYSTEM DRAWING AND DATA SUBMITTALS |
361 | COMMENTARY FIGURE 903.3.1 NFPA 13, NFPA 13R, NFPA 13D SYSTEMS COMMETNARY FIGURE 903.3.1.1 TYPICAL WET-PIPE SYSTEM |
363 | COMMENTARY FIGURE 903.3.1.2.2 OPEN-ENDED CORRIDOR |
368 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
369 | COMMENTARY FIGURE 904.1.1 PERSONNEL QUALIFICATION REQUIREMENTS BY TYPE OF FIRE-EXTINGUISHING AGENT |
370 | COMMENTARY FIGURE 904.2.1 SELECTED EXAMPLES OF REQUIREMENTS MODIFIED THROUGH USE OF AUTOMATIC SPRINKLER SYSTEMS |
377 | COMMENTARY FIGURE 904.11 WATER MIST NOZZLE DISCHARGE |
381 | SECTION 905 STANDPIPE SYSTEMS |
383 | COMMENTARY FIGURE 905.3.1(1) HEIGHT THRESHOLD FOR STANDPIPES COMMENTARY FIGURE 905.3.1(2) HEIGHT REQUIREMENTS FOR STANDPIPES WITH MULTIPLE LEVELS OF FIRE DEPARTMENT VEHICLE ACCESS |
389 | SECTION 906 PORTABLE FIRE EXTINGUISHERS |
391 | TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS |
392 | TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS |
393 | TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25 INCH |
395 | SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
398 | COMMENTARY FIGURE 907.2 SUMMARY OF MANUAL FIRE ALARM AND AUTOMATIC SMOKE DETECTION SYSTEM THRESHOLDS |
409 | COMMENTARY FIGURE 907.2.11.2 LOCATION OF SMOKE ALARMS IN A DWELLING UNIT |
423 | TABLE 907.5.2.3.2 VISIBLE ALARMS |
428 | SECTION 908 EMERGENCY ALARM SYSTEMS SECTION 909 SMOKE CONTROL SYSTEMS |
431 | COMMENTARY FIGURE 909.4.1 STACK EFFECT |
436 | EQUATION 9-1 |
437 | COMMENTARY FIGURE 909.8(1) SMOKE LAYER INTERFACE IN AN ATRIUM |
438 | COMMENTARY FIGURE 909.8(2) AXISYMMETRIC PLUME |
439 | COMMENTARY FIGURE 909.8(3) BALCONY SPILL PLUME COMMENTARY FiIGURE 909.8(4) WINDOW PLUME COMMENTARY FIGURE 909.8(5) PLUGHOLING |
440 | COMMENTARY FIGURE 909.8.1(1) EXAMPLE OF CRITICAL LEVEL OF SMOKE |
441 | COMMENTARY FIGURE 909.8.1(2) SMOKE LAYER INTERFACE |
442 | EQUATION 9-2 |
452 | COMMENTARY FIGURE 909.20.1 DIMENSIONAL REQUIREMENTS FOR SMOKEPROOF ENCLOSURE VESTIBULE |
453 | COMMENTARY FIGURE 909.20.3.2 SMOKEPROOF ENCLOSURE WITH OPEN VESTIBULE ARRANGEMENT |
454 | COMMENTARY FIGURE 909.20.4.1 SMOKEPROOF ENCLOSURE WITH CORRIDOR ARRANGEMENT COMMENTARY FIGURE 909.20.4.2 MECHANICALLY VENTILATED VESTIBULE |
460 | SECTION 910 SMOKE AND HEAT REMOVAL |
462 | EQUATION 9-3 EQUATION 9-4 COMMENTARY FIGURE 910.3.2 SMOKE AND HEAT VENT SPACING |
466 | SECTION 911 EXPLOSION CONTROL |
467 | TABLE 911.1 EXPLOSION CONTROL REQUIREMENTSf |
468 | SECTION 912 FIRE DEPARTMENT CONNECTIONS |
469 | COMMENTARY FIGURE 912.4.1 LOCKING FDC CAPS |
470 | COMMENTARY FIGURE 912.5 FIRE DEPARTMENT CONNECTION WITH SIGN |
471 | SECTION 913 FIRE PUMPS |
473 | SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY |
479 | TABLE 914.8.3 HANGAR FIRE SUPPRESSION REQUIREMENTS |
480 | SECTION 915 CARBON MONOXIDE DETECTION |
483 | COMMENTARY FIGURE 915.2.1 CARBON MONOXIDE ALARM PLACEMENT VERSUS SMOKE DETECTION PLACEMENT |
484 | COMMENTARY FIGURE 915.4.4 COMBINATION CARBON MONOXIDE AND SMOKE ALARM SECTION 916 GAS DETECTION SYSTEMS |
486 | SECTION 917 MASS NOTIFICATION SYSTEMS BIBLIOGRAPHY |
488 | CHAPTER 10: MEANS OF EGRESS GENERAL COMMENTS PURPOSE |
489 | SECTION 1001 ADMINISTRATION SECTION 1002 DEFINITIONS |
490 | SECTION 1003 GENERAL MEANS OF EGRESS |
492 | COMMENTARY FIGURE 1003.3.1(1) DOOR CLOSER HEADROOM PROTRUSIONS FOR CIRCULATION ROUTES COMMENTARY FIGURE 1003.3.1(2) REDUCED VERTICAL CLEARANCE COMMENTARY FIGURE 1003.3.2(1) POST-MOUNTED OBJECTS |
493 | COMMENTARY FIGURE 1003.3.2(2) POST-MOUNTED PROTRUDING OBJECTS COMMENTARY FIGURE 1003.3.3 EXAMPLE OF HORIZONTAL PROJECTIONS |
495 | SECTION 1004 OCCUPANT LOAD |
496 | COMMENTARY FIGURE 1004.2 COMBINED OCCUPANT LOAD FOR EGRESS DESIGN |
498 | [BE] TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT |
499 | COMMENTARY FIGURE 1004.5 TYPICAL NET FLOOR AREA OCCUPANT LOAD CALCULATION |
500 | COMMENTARY FIGURE 1004.6 TYPICAL FIXED SEATING |
501 | COMMENTARY FIGURE 1004.9 EXAMPLE OF OCCUPANT LOAD LIMIT SIGN SECTION 1005 MEANS OF EGRESS SIZING |
505 | COMMENTARY FIGURE 1005.6(1) EGRESS CONVERGENCE AT FIRST STORY COMMENTARY FIGURE 1005.6(2) EGRESS CONVERGENCE AT INTERMEDIATE LEVEL |
506 | COMMENTARY FIGURE 1005.6(3) NO EGRESS CONVERGENCE |
507 | COMMENTARY FIGURE 1005.7.1 TYPICAL DOOR RESTRICTIONS INTO PASSAGEWAY, AISLE AND CORRIDOR WIDTH SECTION 1006 NUMBERS OF EXITS AND EXIT ACCESS DOORWAYS |
508 | COMMENTARY FIGURE 1006.2.1 COMMON PATH OF EGRESS TRAVEL |
509 | [BE] TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY |
512 | [BE] TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY |
513 | COMMENTARY FIGURE 1006.3.3 NUMBER OF EXITS |
514 | COMMENTARY FIGURE 1006.3.4(1) MULTISTORY DWELLING UNITS |
515 | [BE] TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES COMMENTARY FIGURE 1006.3.4(2) EXAMPLE OF SINGLE-EXIT APARTMENT BUILDING COMMENTARY FIGURE 1006.3.4(3) EXAMPLE OF SINGLE-EXIT APARTMENT WITHIN A TWO-EXIT BUILDING |
516 | [BE] TABLE 1006.3.4(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES |
517 | COMMENTARY FIGURE 1006.3.4.1 STORIES WITH ONE EXIT SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION |
519 | COMMENTARY FIGURE 1007.1.1(1) EXAMPLES OF REMOTENESS BETWEEN EXITS OR EXIT ACCESS DOORS FROM A ROOM OR STORY |
520 | COMMENTARY FIGURE 1007.1.1(2) REMOTENESS OF INTERCONNECTING BY A 1-HOUR FIRE-RESISTANCE-RATED CORRIDOR COMMENTARY FIGURE 1007.1.1(3) REMOTENESS OF EXITS IN A BUILDING WITH AN AUTOMATIC SPRINKLER SYSTEM |
521 | COMMENTARY FIGURE 1007.1.1(4) REMOTE LOCATION OF EXIT ACCESS DOORS (ADJOINING ROOMS) COMMENTARY FIGURE 1007.1.3 REMOTENESS OF EXIT ACCESS STAIRWAYS OR RAMPS SECTION 1008 MEANS OF EGRESS ILLUMINATION |
524 | SECTION 1009 ACCESSIBLE MEANS OF EGRESS |
528 | COMMENTARY FIGURE 1009.2.1 ELEVATOR REQUIRED FOR ACCESSIBLE MEANS OF EGRESS |
530 | COMMENTARY FIGURE 1009.3.3(1) ACCESSIBLE MEANS OF EGRESS STAIRWAY WITH ENLARGED STORY-LEVEL LANDING |
531 | COMMENTARY FIGURE 1009.3.3(2) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM AN AREA OF REFUGE COMMENTARY FIGURE 1009.3.3(3) ACCESSIBLE MEANS OF EGRESS STAIRWAY ACCESSED FROM A HORIZONTAL EXIT |
534 | COMMENTARY FIGURE 1009.6 SEPARATE TRAVEL DISTANCES TO AN AREA OF REFUGE |
536 | COMMENTARY FIGURE 1009.7.1 EXTERIOR AREA OF RESCUE ASSISTANCE—PLAN VIEW |
537 | COMMENTARY FIGURE 1009.7.2 EXTERIOR AREA FOR RESCUE ASSISTANCE—ELEVATION |
540 | SECTION 1010 DOORS, GATES AND TURNSTILES |
541 | COMMENTARY FIGURE 1010.1.1(1) TYPICAL DOOR OPENING CLEARANCE COMMENTARY FIGURE 1010.1.1(2) TYPICAL DOOR OPENING CLEARANCE WITH PANIC HARDWARE |
545 | COMMENTARY FIGURE 1010.1.3(1) EXAMPLE OF PUSH FORCE COMMENTARY FIGURE 1010.1.3(2) EXAMPLE OF ROTATIONAL FORCE |
546 | COMMENTARY FIGURE 1010.1.4(1) ELEVATION CHANGE COMMENTARY FIGURE 1010.1.4(2) DOOR LANDINGS |
548 | COMMENTARY FIGURE 1010.1.7(1) VERTICAL CHANGES IN LEVEL COMMENTARY FIGURE 1010.1.7(2) BEVELED CHANGES IN LEVEL COMMENTARY FIGURE 1010.1.7(3) BEVELED CHANGES IN LEVEL COMMENTARY FIGURE 1010.1.7(4) DOOR THRESHOLD HEIGHT LIMITATIONS COMMENTARY FIGURE 1010.1.7(5) EXAMPLE OF EXCEPTON 2 |
549 | COMMENTARY FIGURE 1010.1.7(1) SPACING OF DOORS IN A SERIES COMMENTARY FIGURE 1010.1.7(2) SPACING OF DOORS IN A SERIES |
550 | COMMENTARY FIGURE 1010.2.2 DOOR HARDWARE |
552 | COMMENTARY FIGURE 1010.2.4 SURFACE AND FLUSH BOLT LOCATIONS |
553 | COMMENTARY FIGURE 1010.2.5 TYPICAL MANUAL BOLT HARDWARE |
556 | COMMENTARY FIGURE 1010.2.9.3(1) EXAMPLES OF TYPICAL PANIC HARDWARE |
557 | COMMENTARY FIGURE 1010.2.9.3(2) EXAMPLES OF TYPICAL PANIC HARDWARE |
565 | COMMENTARY FIGURE 1010.3.1(1) REVOLVING DOORS IN BREAKOUT POSITION COMMENTARY FIGURE 1010.1.4.1(2) TYPICAL REVOLVING DOOR/SIDE-HINGED SWINGING DOOR ARRANGEMENT |
566 | [BE] TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS COMMENTARY FIGURE 1010.1.4.1(3) EXAMPLE OF MANUAL REVOLVING DOOR (7-FOOT DIAMETER) COMMENTARY FIGURE 1010.1.4.1(4) EXAMPLE OF AUTOMATIC REVOLVING DOOR (8-FOOT DIAMETER) COMMENTARY FIGURE 1010.1.4.1(5) EXAMPLE OF AUTOMATIC REVOLVING DOOR (20-FOOT DIAMETER) |
567 | [BE] TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS |
570 | COMMENTARY FIGURE 1010.5.1 EXAMPLES OF THREE 3-ARM, ROTATING TURNSTILES AND ONE SIDE-SWINGING TURNSTILE |
571 | COMMENTARY FIGURE 1010.5.2 EXAMPLE OF SECURITY ACCESS TURNSTILES COMMENTARY FIGURE 1010.5.3(1) EXAMPLE OF HIGH TURNSTILE THAT OPERATES SIMILAR TO A REVOLVING DOOR COMMENTARY FIGURE 1010.5.3(2) EXAMPLE OF HIGH TURNSTILE THAT OPERATES AS A SECURITY ACCESS TURNSTILE |
572 | SECTION 1011 STAIRWAYS |
574 | COMMENTARY FIGURE 1011.3(1) STAIRWAY HEADROOM REQUIREMENTS COMMENTARY FIGURE 1011.3(2) EXAMPLE OF SECTION 1011.3, EXCEPTION 2 |
575 | COMMENTARY FIGURE 1011.5.1 TREAD DEPTH MEASUREMENT |
577 | COMMENTARY FIGURE 1011.5.2 TREAD/RISER DIMENSIONS COMMENTARY FIGURE 1011.5.3 STAIR WINDERS WITHIN A DWELLING |
578 | COMMENTARY FIGURE 1011.5.4 CONSISTENTLY SHAPED WINDERS |
579 | COMMENTARY FIGURE 1011.5.4.1 SLOPED LANDING COMMENTARY FIGURE 1011.5.5.1 TREAD/RISER PROFILE (SOLID RISER) |
580 | COMMENTARY FIGURE 1011.5.5.3 TREAD/RISER PROFILE (OPEN RISER) |
581 | COMMENTARY FIGURE 1011.6(1) TYPICAL LANDING DIMENSIONS—STRAIGHT-RUN STAIRWAY COMMENTARY FIGURE 1011.6(2) TYPICAL LANDING DIMENSIONS—STRAIGHT-RUN STAIRWAY WIDER THAN 48 INCHES |
582 | COMMENTARY FIGURE 1011.6(3) DOOR CLEARANCE REQUIREMENTS IN STAIRWAYS COMMENTARY FIGURE 1011.6(4) MEASUREMENT OF CURVED LANDINGS |
583 | COMMENTARY FIGURE 1011.6(5) LANDING AT SWITCHBACK STAIRWAY COMMENTARY FIGURE 1011.6(6) LANDING AT 90-DEGREE TURN |
584 | COMMENTARY FIGURE 1011.7.1 OPEN TREAD IN ACCORDANCE WITH EXCEPTION 1 COMMENTARY FIGURE 1011.8 STAIRWAY RISE LIMITATION |
585 | COMMENTARY FIGURE 1011.9 CURVED STAIRWAYS—MINIMUM DIMENSIONAL REQUIREMENTS |
586 | COMMENTARY FIGURE 1011.10 SPIRAL STAIRWAYS |
587 | COMMENTARY FIGURE 1011.11(1) EXAMPLE OF SECTION 1011.11, EXCEPTION 2 COMMENTARY FIGURE 1011.11(2) EXAMPLE OF SECTION 1011.11, EXCEPTION 5 |
588 | COMMENTARY FIGURE 1011.14 TYPICAL ALTERNATING TREAD DEVICE |
590 | COMMENTARY FIGURE 1011.15 TYPICAL SHIP’S LADDER SECTION 1012 RAMPS |
591 | COMMENTARY FIGURE 1012.2 TYPICAL MEANS OF EGRESS RAMP |
593 | COMMENTARY FIGURE 1012.5.3 DOORWAY OPENING ONTO LANDING COMMENTARY FIGURE 1012.6 RAMP LANDINGS |
595 | COMMENTARY FIGURE 1012.8(1) RAMP WITH HANDRAIL AT WALL COMMENTARY FIGURE 1012.8(2) RAMP WITH HANDRAIL AND BARRIER COMMENTARY FIGURE 1012.8(3) RAMP WITH HANDRAIL AND CURB |
596 | COMMENTARY FIGURE 1012.8(4) RAMP WITH HANDRAIL AND GUARD |
597 | COMMENTARY FIGURE 1012.10.1 EDGE PROTECTION SECTION 1013 EXIT SIGNS |
598 | COMMENTARY FIGURE 1013.1 EXIT SIGNS WITHIN AN EXIT ENCLOSURE |
599 | COMMENTARY FIGURE 1013.4 EXAMPLE OF EXIT SIGNAGE WITH VISUAL AND RAISED CHARACTERS WITH BRAILLE |
600 | COMMENTARY FIGURE 1013.6.1 MINIMUM SIZE OF EXIT SIGNS SECTION 1014 HANDRAILS |
601 | COMMENTARY FIGURE 1014.2 HANDRAIL REQUIREMENTS |
603 | COMMENTARY FIGURE 1014.3.1 EXAMPLE OF TYPE I ALTERNATIVE HANDRAIL CONFIGURATION COMMENTARY FIGURE 1014.3.2 EXAMPLES OF TYPE II HANDRAIL CONFIGURATIONS |
604 | COMMENTARY FIGURE 1014.4(1) EXAMPLES OF PROHIBITED HANDRAIL DESIGNS |
605 | COMMENTARY FIGURE 1014.4(2) REDUCED BRACKET EXTENSIONS EXAMPLE PER SECTION 1014.4, EXCEPTION 3 |
606 | COMMENTARY FIGURE 1014.8(1) TYPICAL HANDRAIL ARRANGEMENT |
607 | COMMENTARY FIGURE 1014.8(2) PROJECTION OF HANDRAIL COMMENTARY FIGURE 1014.9 HANDRAILS FOR MONUMENTAL STAIRS SECTION 1015 GUARDS |
608 | COMMENTARY FIGURE 1015.2 DROP-OFF MEASUREMENTS AND GUARD HEIGHTS |
609 | COMMENTARY FIGURE 1015.2.1 GUARD SYSTEM WITH GLAZING COMMENTARY FIGURE 1015.3 DROP-OFF MEASUREMENTS AND GUARD HEIGHTS FOR TWO- AND THREE-STORY GROUP R-2 AND R-3 |
611 | COMMENTARY FIGURE 1015.4(1) GUARD HEIGHT AND OPENING LIMITATIONS COMMENTARY FIGURE 1015.4(2) GUARD OPENING LIMITATIONS, SECTION 1015.4, EXCEPTIONS 3 AND 4 COMMENTARY FIGURE 1015.4(3) EXAMPLE OF GUARD WITH HORIZONTAL MEMBERS |
612 | COMMENTARY FIGURE 1015.7 PROTECTION AT ROOF-HATCH OPENING |
613 | SECTION 1016 EXIT ACCESS |
615 | COMMENTARY FIGURE 1016.2(1) EGRESS PROHIBITED THROUGH GROUP H AREAS COMMENTARY FIGURE 1016.2(2) EGRESS THROUGH ADJOINING ROOMS AND SPACES |
616 | SECTION 1017 EXIT ACCESS TRAVEL DISTANCE [BE] TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa |
618 | COMMENTARY FIGURE 1017.3(1) LENGTH OF EXIT ACCESS TRAVEL COMMENTARY FIGURE 1017.3(2) MEASURING TRAVEL DISTANCE USING RECTILINEAR APPROACH |
619 | SECTION 1018 AISLES |
620 | COMMENTARY FIGURE 1018.4 AISLES AND AISLE ACCESSWAYS IN MERCANTILE |
621 | SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS |
623 | COMMENTARY FIGURE 1019.3 DRAFT CURTAIN, EXCEPTION 4 SECTION 1020 CORRIDORS |
624 | COMMENTARY FIGURE 1020.2 APPLICATION OF TABLE 1020.2 |
625 | [BE] TABLE 1020.2 CORRIDOR FIRE-RESISTANCE RATING |
627 | [BE] TABLE 1020.3 MINIMUM CORRIDOR WIDTH |
628 | COMMENTARY FIGURE 1020.5(1) ALLOWABLE DEAD-END CONDITIONS |
629 | COMMENTARY FIGURE 1020.5(2) CORRIDOR LENGTH/WIDTH RATIO FOR DEAD-END CONSIDERATIONS |
631 | COMMENTARY FIGURE 1020.7(1) CORRIDOR CONTINUITY—EXAMPLE 1 |
632 | COMMENTARY FIGURE 1020.7(2) CORRIDOR CONTINUITY—EXAMPLE 2 COMMENTARY FIGURE 1020.7(3) CORRIDOR CONTINUITY—EXAMPLE 3 COMMENTARY FIGURE 1020.7(4) ELEVATOR LOBBY/CORRIDOR OPTION 1 |
633 | COMMENTARY FIGURE 1020.7(5) ELEVATOR LOBBY/CORRIDOR OPTION 2 COMMENTARY FIGURE 1020.7(6) ELEVATOR LOBBY/CORRIDOR OPTION 3 SECTION 1021 EGRESS BALCONIES |
634 | COMMENTARY FIGURE 1021.2 EGRESS BALCONIES SECTION 1022 EXITS |
635 | SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMP |
641 | COMMENTARY FIGURE 1023.7 EXAMPLES OF EXTERIOR WALL PROTECTION AT INTERIOR EXIT STAIRWAYS |
642 | COMMENTARY FIGURE 1023.8 EXAMPLE OF A STAIRWAY BARRIER AT THE LEVEL OF EXIT DISCHARGE COMMENTARY FIGURE 1023.9.1 STAIRWAY IDENTIFICATION SIGN |
644 | COMMENTARY FIGURE 1023.12.2(1) TYPICAL SMOKEPROOF ENCLOSURE ENTRY COMMENTARY FIGURE 1023.12.2(2) TYPICAL SMOKEPROOF ENCLOSURE WITH OPEN BALCONY ARRANGEMENT |
645 | SECTION 1024 EXIT PASSAGEWAYS COMMENTARY FIGURE 1024.1 ARRANGEMENT FOR LOBBY AND PASSAGEWAY |
648 | SECTION 1025 LUMINOUS EGRESS PATH MARKINGS |
649 | COMMENTARY FIGURE 1025.2.1 LEADING EDGE OF STEP AND LANDING COMMENTARY FIGURE 1025.2.3 HANDRAIL MARKINGS |
650 | COMMENTARY FIGURE 1025.2.4.1 PERIMETER DEMARCATION LINES—FLOOR-MOUNTED OPTION COMMENTARY FIGURE 1025.2.4.2 PERIMETER DEMARCATION LINES—WALL-MOUNTED OPTION |
651 | COMMENTARY FIGURE1025.2.5 OBSTACLE MARKINGS COMMENTARY FIGURE 1025.2.4.3 PERIMETER DEMARCATION LINES—OPTIONS AT DOORS INTO EXIT ENCLOSURES |
652 | COMMENTARY FIGURE 1025.2.6 EXIT DOOR TO EXTERIOR EXAMPLES |
653 | COMMENTARY FIGURE 1025.2.6.1 EMERGENCY EXIT SYMBOL |
654 | SECTION 1026 HORIZONTAL EXITS COMMENTARY FIGURE 1026.1 TYPICAL HORIZONTAL EXITS |
656 | COMMENTARY FIGURE 1026.4.2 REFUGE AREA EXCEPTION |
657 | SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS |
658 | COMMENTARY FIGURE 1027.3 EXTERIOR STAIRWAY |
659 | COMMENTARY FIGURE 1027.5 EXTERIOR BALCONY AND STAIRWAY ADJACENT TO LOT LINE |
660 | COMMENTARY FIGURE 1027.6(1) PROTECTION OF EXTERIOR STAIRWAYS |
661 | COMMENTARY FIGURE 1027.6(2) EXTERIOR BALCONY WITH REMOTE STAIRWAYS COMMENTARY FIGURE 1027.6(3) EXAMPLE OF EXCEPTION 3 |
662 | SECTION 1028 EXIT DISCHARGE |
664 | COMMENTARY FIGURE 1028.2(1) PROTECTION OF LOBBY WITH AN EXIT DISCHARGE COMMENTARY FIGURE 1028.2(2) VESTIBULE WITH EXIT DISCHARGE COMMENTARY FIGURE 1028.2(3) SEPARATION DETAILS FOR VESTIBULE WITH EXIT DISCHARGE |
665 | SECTION 1029 EGRESS COURTS SECTION 1030 ASSEMBLY |
667 | COMMENTARY FIGURE 1030.1.1 EXAMPLE OF BLEACHERS (COURTESY OF HUSSEY SEATING) |
668 | COMMENTARY FIGURE 1030.2 GROUP A-1 WITH WAITING SPACE |
670 | COMMENTARY FIGURE 1030.6.1(1) COMPUTATION OF WIDTH FOR STEPPED AISLES COMMENTARY FIGURE 1030.6.1(2) COMPUTATION OF WIDTH FOR LEVEL, SLOPED OR RAMPED AISLES |
671 | [BE] TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY |
672 | COMMENTARY FIGURE 1030.6.2.2(1) ROOF HEIGHT (CONVEX DOME ROOF) COMMENTARY FIGURE 1030.6.2.2(2) ROOF HEIGHT (CONCAVE SUSPENDED ROOF) |
673 | COMMENTARY FIGURE 1029.6.2.3(1) INDOOR SEATING SPRINKLERED AREAS (CONVEX DOME ROOF) COMMENTARY FIGURE 1029.6.2.3(2) INDOOR SEATING SPRINKLERED AREAS (CONCAVE SUSPENDED ROOF) |
676 | COMMENTARY FIGURE 1030.8.1 PATH THROUGH ADJACENT ROWS |
677 | COMMENTARY FIGURE 1030.9.2 TYPICAL AISLE CATCHMENTS |
678 | COMMENTARY FIGURE 1030.9.3 COMPUTATION OF EXIT PASSAGE FOR CONVERGING AISLES COMMENTARY FIGURE 1030.9.4 AISLE WITH OPPOSITE EXITS |
679 | COMMENTARY FIGURE 1030.9.5 TYPICAL BALCONY ARRANGEMENT |
680 | COMMENTARY FIGURE 1030.9.7(1) EXAMPLE OF A CONTINUATION OF A STEPPED AISLE UP TO A CROSS AISLE COMMENTARY FIGURE 1030.9.7(2) EXAMPLE OF A CONTINUATION OF A STEPPED AISLE DOWN TO A FLOOR |
681 | COMMENTARY FIGURE 1030.10.2.1(1) TRANSITION BETWEEN STAIRWAY AND STEPPED AISLE AT THE HIGHER END OF THE FLIGHT COMMENTARY FIGURE 1030.10.2.1(2) TRANSITION BETWEEN STEPPED AISLE AND STAIRWAY AT THE LOWER END OF THE FLIGHT |
682 | COMMENTARY FIGURE 1030.10.2.2 EXAMPLE OF A STEPPED AISLE TURNING TO A STAIRWAY COMMENTARY FIGURE 1030.11 EXAMPLE OF TURNS IN A STEPPED AISLE AT A VOMITORY |
683 | COMMENTARY FIGURE 1030.13.1 AISLE AND AISLE ACCESSWAY MEASUREMENT WITH SEATING AND TABLES |
684 | COMMENTARY FIGURE 1030.13.1.1 ACCESS FOR TABLES AND SEATING |
685 | COMMENTARY FIGURE 1030.13.2(1) MINIMUM REQUIRED ROW WIDTH CLEARANCE FOR AISLE ACCESSWAYS COMMENTARY FIGURE 1030.13.2(2) EXAMPLE OF FOLDING TABLET ARMS |
686 | COMMENTARY FIGURE 1030.13.2.1 TYPICAL DUAL-ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH [BE] TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS |
687 | COMMENTARY FIGURE 1030.13.2.2 TYPICAL SINGLE-ACCESS ROW—MINIMUM AISLE ACCESSWAY WIDTH FOR SEATS WITH BACKRESTS |
688 | COMMENTARY FIGURE 1030.14.2.1 TYPICAL SEATING PLATFORMS ALSO USED AS STEPPING AISLES |
689 | COMMENTARY FIGURE 1030.14.2.2 TYPICAL RISER CONSTRUCTION IN STEPPED AISLES |
691 | COMMENTARY FIGURE 1030.16(1) TYPICAL RAILING FOR RAMPED AISLES WITH RAILING IN THE AISLE COMMENTARY FIGURE 1030.16(2) EXAMPLE OF STEPPED AISLES ADJACENT TO SEATING PLATFORMS |
692 | COMMENTARY FIGURE 1030.16.1 DISCONTINUOUS AISLE HANDRAILS |
694 | COMMENTARY FIGURE 1030.17.3 TYPICAL BALCONY GUARDS AT FASCIA SECTION 1031 EMERGENCY ESCAPE AND RESCUE |
696 | COMMENTARY FIGURE 1031.3.1 EMERGENCY ESCAPE WINDOW |
697 | COMMENTARY FIGURE 1031.5 AREA WELLS AT EMERGENCY ESCAPE WINDOWS |
698 | SECTION 1032 MAINTENANCE OF THE MEANS OF EGRESS |
701 | COMMENTARY FIGURE 1032.10 TYPICAL BATTERY EMERGENCY LIGHTING BIBLIOGRAPHY |
704 | CHAPTER 11: CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS GENERAL COMMENTS PURPOSE SECTION 1101 GENERAL |
705 | SECTION 1102 DEFINITIONS SECTION 1103 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS |
706 | TABLE 1103.1 OCCUPANCY AND USE REQUIREMENTSa |
709 | COMMENTARY FIGURE 1103.4 STACK EFFECT AND SMOKE MIGRATION VIA VERTICAL SHAFTS |
721 | SECTION 1104 MEANS OF EGRESS FOR EXISTING BUILDINGS |
724 | TABLE 1104.9 REVOLVING DOOR SPEEDS |
727 | TABLE 1104.18 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS |
729 | SECTION 1105 CONSTRUCTION REQUIREMENTS FOR EXISTING GROUP I-2 |
730 | TABLE 1105.3 FLOOR LEVEL LIMITATIONS FOR GROUP I-2, CONDITION 2 |
731 | TABLE 1105.4 INCIDENTAL USES IN EXISTING GROUP I-2 OCCUPANCIES |
737 | SECTION 1106 REQUIREMENTS FOR OUTDOOR OPERATIONS |
738 | BIBLIOGRAHY |
740 | CHAPTER 12: ENERGY SYSTEMS GENERAL COMMENTS PURPOSE SECTION 1201 GENERAL |
741 | SECTION 1202 DEFINITIONS SECTION 1203 EMERGENCY AND STANDBY POWER SYSTEMS |
747 | SECTION 1204 PORTABLE GENERATORS |
748 | SECTION 1205 SOLAR PHOTOVOLTAIC POWER SYSTEMS COMMENTARY FIGURE 1205.1 BASIC SCHEMATIC OF A PHOTOVOLTAIC SYSTEM |
750 | COMMENTARY FIGURE 1205.2.1 INSTALLATION OF A PV ARRAY ON AN R-3 OCCUPANCY |
752 | FIGURE 1205.4.1(1) LABEL FOR SOLAR PV SYSTEMS THAT REDUCE SHOCK HAZARD WITHIN ARRAY AND SHUT DOWN CONDUCTORS LEAVING ARRAY FIGURE 1205.4.1(2) LABEL FOR SOLAR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY |
753 | SECTION 1206 STATIONARY FUEL CELL POWER SYSTEMS |
756 | SECTION 1207 ELECTRICAL ENERGY STORAGE SYSTEMS (ESS) |
757 | TABLE 1207.1.1 ENERGY STORAGE SYSTEM (ESS) THRESHOLD QUANTITIES |
764 | TABLE 1207.5 MAXIMUM ALLOWABLE QUANTITIES OF ELECTROCHEMICAL ESS |
767 | TABLE 1207.6 ELECTROCHEMICAL ESS TECHNOLOGY-SPECIFIC REQUIREMENTS |
770 | TABLE 1207.7 INDOOR ESS INSTALLATIONS |
771 | TABLE 1207.8 OUTDOOR ESS INSTALLATIONSa |
773 | TABLE 1207.9 SPECIAL ESS INSTALLATIONS |
775 | TABLE 1207.10 MOBILE ENERGY STORAGE SYSTEMS (ESS) |
779 | BIBLIOGRAPHY |
780 | CHAPTER 13 THROUGH 19: RESERVED |
782 | INDEX |
812 | ADDITIONAL CODE RESOURCES FROM ICC |
813 | PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™) |
814 | ICC LEARNING CENTER |
815 | ICC DIGITAL CODES PREMIUM |
816 | 2021 IFC® CODE AND COMMENTARY VOLUME 2 |
817 | 2021 IFC® CODE AND COMMENTARY VOLUME 2 TITLE PAGE |
818 | COPYRIGHT |
819 | PREFACE |
821 | ARRANGEMENT AND FORMAT OF THE 2021 IFC |
823 | TABLE OF CONTENTS |
827 | PART IV—SPECIAL OCCUPANCIES AND OPERATIONS CHAPTER 20: AVIATION FACILITIES GENERAL COMMENTS PURPOSE SECTION 2001 GENERAL SECTION 2002 DEFINITIONS SECTION 2003 GENERAL PRECAUTIONS |
828 | SECTION 2004 AIRCRAFT MAINTENANCE |
829 | SECTION 2005 PORTABLE FIRE EXTINGUISHERS |
831 | SECTION 2006 AIRCRAFT FUELING |
832 | COMMENTARY FIGURE 2006.2 PHYSICAL AND FLAMMABILITY CHARACTERISTICS OF AVIATION FUELS COMMENTARY FIGURE 2006.3 AIRCRAFT-FUELING VEHICLE |
841 | SECTION 2007 HELISTOPS AND HELIPORTS COMMENTARY FIGURE 2007.1 HELICOPTER LANDING AREA AT GRADE |
842 | BIBLIOGRAPHY |
843 | CHAPTER 21: DRY CLEANING GENERAL COMMENTS PURPOSE SECTION 2101 GENERAL SECTION 2102 DEFINITIONS SECTION 2103 CLASSIFICATIONS |
845 | COMMENTARY FIGURE 2103.2.1 CHARACTERISTICS OF DRY CLEANING SOLVENTS SECTION 2104 GENERAL REQUIREMENTS |
846 | SECTION 2105 OPERATING REQUIREMENTS |
848 | EQUATION 21-1 |
849 | SECTION 2106 SPOTTING AND PRETREATING |
850 | SECTION 2107 DRY CLEANING SYSTEMS |
851 | SECTION 2108 FIRE PROTECTION |
852 | BIBLIOGRAPHY |
853 | CHAPTER 22: COMBUSTIBLE DUST-PRODUCING OPERATIONS GENERAL COMMENTS COMMENTARY FIGURE 22-1 DUST EXPLOSION PENTAGON |
854 | PURPOSE SECTION 2201 GENERAL |
855 | SECTION 2202 DEFINITIONS SECTION 2203 DUST EXPLOSION PREVENTION TABLE 2203.1 CRITICAL DEPTH LAYER |
856 | TABLE 2203.3.1.2 MINIMUM CONVEYING VELOCITIES |
859 | SECTION 2204 DUST EXPLOSION SCREENING TESTS |
860 | SECTION 2205 STANDARDS TABLE 2205.1 EXPLOSION PROTECTION STANDARDS BIBLIOGRAPHY |
861 | CHAPTER 23: MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES GENERAL COMMENTS PURPOSE SECTION 2301 GENERAL |
862 | SECTION 2302 DEFINITIONS SECTION 2303 LOCATION OF DISPENSING DEVICES COMMENTARY FIGURE 2303.1(1) LOCATION OF DISPENSING DEVICES |
863 | COMMENTARY FIGURE 2303.1(2) LOCATION OF DISPENSING DEVICES COMMENTARY FIGURE 2303.1(3) LOCATION OF DISPENSING DEVICES COMMENTARY FIGURE 2303.1(4) LOCATION OF DISPENSING DEVICES COMMENTARY FIGURE 2303.1(5) LOCATION OF DISPENSING DEVICES |
864 | COMMENTARY FIGURE 2303.2 EMERGENCY DISCONNECT SWITCH SECTION 2304 DISPENSING OPERATIONS |
866 | SECTION 2305 OPERATIONAL REQUIREMENTS |
869 | SECTION 2306 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES |
870 | COMMENTARY FIGURE 2306.2.3(1) ABOVE-GROUND TANKS LOCATED OUTSIDE ABOVE GRADE COMMENTARY FIGURE 2306.2.3(2) BIODIESEL FUELING KIOSK |
871 | TABLE 2306.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS |
872 | COMMENTARY FIGURE 2306.2.3(3) BIODIESEL FUELER COMMENTARY FIGURE 2306.2.3(4) 6,000-GALLON OR LESS PROTECTED ABOVE-GROUND STORAGE TANKS STORING CLASS I, II OR III LIQUIDS |
873 | COMMENTARY FIGURE 2306.2.3(5) GREATER THAN 6,000-GALLON PROTECTED ABOVE-GROUND STORAGE TANKS STORING CLASS I, II OR III LIQUIDS COMMENTARY FIGURE 2306.2.3(6) ALL OTHER ABOVE-GROUND STORAGE TANKS STORING CLASS II OR III LIQUIDS ONLY |
876 | COMMENTARY FIGURE 2306.7.3 MOUNTING OF DISPENSERS |
877 | COMMENTARY FIGURE 2306.7.4 DISPENSER EMERGENCY VALVES |
878 | COMMENTARY FIGURE 2306.7.5.1 BREAKAWAY DEVICES |
879 | COMMENTARY FIGURE 2306.7.7.2 LOCATION OF ABOVE-GRADE REMOTE PUMPS |
883 | COMMENTARY FIGURE 2306.8.5 ALCOHOL-BLENDED FUEL DISPENSER SIGN SECTION 2307 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES |
885 | COMMENTARY FIGURE 2307.7 PUBLIC LP-GAS FUEL DISPENSER |
886 | SECTION 2308 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES |
888 | TABLE 2308.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG |
889 | SECTION 2309 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES |
893 | SECTION 2310 MARINE MOTOR FUEL-DISPENSING FACILITIES |
896 | SECTION 2311 REPAIR GARAGES |
899 | TABLE 2311.6.2 TEMPERATURE COMPENSATED CYLINDER PRESSURE TABLEa |
903 | BIBLIOGRAPHY |
905 | CHAPTER 24: FLAMMABLE FINISHES GENERAL COMMENTS PURPOSE SECTION 2401 GENERAL |
906 | SECTION 2402 DEFINITIONS SECTION 2403 PROTECTION OF OPERATIONS |
907 | COMMENTARY FIGURE 2403.2.1.1(1) FLAMMABLE VAPOR AREA—ELECTRICAL CLASSIFICATION |
908 | COMMENTARY FIGURE 2403.2.1.1(2) EXTENT OF CLASS I, DIVISIONS I AND 2 LOCATIONS IN ENCLOSED COATING PROCESS |
911 | COMMENTARY FIGURE 2403.3.5.1 SPRAY GUN CLEANING MACHINE |
912 | SECTION 2404 SPRAY FINISHING |
914 | COMMENTARY FIGURE 2404.3.3.5 EXAMPLE OF SPRAY-BOOTH CLEAR SPACE |
916 | COMMENTARY FIGURE 2404.4.1 MAXIMUM TRAVEL TO EXTINGUISHERS |
920 | COMMENTARY FIGURE 2404.7.5(1) INDEPENDENT DUCTS FOR SPRAY BOOTHS |
921 | COMMENTARY FIGURE 2404.7.5(2) COMMON DUCTING FOR SPRAY BOOTHS |
922 | COMMENTARY FIGURE 2404.7.6(1) SEPARATION REQUIREMENTS FOR ROOF EXHAUST DUCT PENETRATIONS COMMENTARY FIGURE 2404.7.6(2) SEPARATION REQUIREMENTS |
925 | SECTION 2405 DIPPING OPERATIONS |
928 | COMMENTARY FIGURE 2405.9.1 SEPARATION REQUIREMENTS FOR QUENCHING TANKS |
929 | COMMENTARY FIGURE 2405.9.3 TYPICAL QUENCH TANK ALARM LOCATION COMMENTARY FIGURE 2405.10 TYPICAL FLOW-COAT SETUP |
930 | COMMENTARY FIGURE 2405.11 TYPICAL ROLL-COATING SETUP SECTION 2406 POWDER COATING |
932 | SECTION 2407 ELECTROSTATIC APPARATUS |
934 | SECTION 2408 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS |
935 | SECTION 2409 INDOOR MANUFACTURING OF REINFORCED PLASTICS |
936 | SECTION 2410 FLOOR SURFACING AND FINISHING OPERATIONS |
937 | BIBLIOGRAPHY |
939 | CHAPTER 25: FRUIT AND CROP RIPENING GENERAL COMMENTS PURPOSE SECTION 2501 GENERAL COMMENTARY FIGURE 2501.1 FLAMMABILITY CHARACTERISTICS AND ETHYLENE HAZARDS |
940 | SECTION 2502 DEFINITIONS SECTION 2503 ETHYLENE GAS SECTION 2504 SOURCES OF IGNITION |
941 | SECTION 2505 COMBUSTIBLE WASTE SECTION 2506 ETHYLENE GENERATORS |
942 | SECTION 2507 WARNING SIGNS BIBLIOGRAPHY |
943 | CHAPTER 26: FUMIGATION AND INSECTICIDAL FOGGING GENERAL COMMENTS SPECIAL FIRE PROTECTION PROBLEMS INFORMATION SOURCES STORAGE AND HANDLING PURPOSE |
944 | COMMENTARY FIGURE 26-1 HAZARDOUS PROPERTIES OF COMMON FUMIGANTS SECTION 2601 GENERAL SECTION 2602 DEFINITIONS |
945 | SECTION 2603 FIRE SAFETY REQUIREMENTS |
946 | COMMENTARY FIGURE 2603.3.1 FUMIGATION WARNING SIGN |
948 | BIBLIOGRAPHY |
949 | CHAPTER 27: SEMICONDUCTOR FABRICATION FACILITIES GENERAL COMMENTS PURPOSE SECTION 2701 GENERAL |
950 | COMMENTARY FIGURE 2701.1(1) TYPICAL COMPONENTS OF AN HPM FACILITY SECTION 2702 DEFINITIONS SECTION 2703 GENERAL SAFETY PROVISIONS |
951 | COMMENTARY FIGURE 2701.1(2) HAZARDOUS PRODUCTION MATERIALS (HPM) USED IN THE MANUFACTURE OF SEMICONDUCTORS |
953 | COMMENTARY FIGURE 2703.3.1 CLEAN ROOM CLASSIFICATIONS |
957 | COMMENTARY FIGURE 2703.10.4.1 CROSS-SECTIONAL DIAMETERS OF VARIOUS-SHAPED DUCTS |
962 | COMMENTARY FIGURE 2703.16 COMMON DOPANT GASES AND THEIR HAZARD CLASSIFICATION |
963 | SECTION 2704 STORAGE |
964 | TABLE 2704.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5 |
965 | TABLE 2704.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a SECTION 2705 USE AND HANDLING |
966 | TABLE 2705.2.2 MAXIMUM QUANTITIES OF HPM AT A WORK |
969 | BIBLIOGRAPHY |
971 | CHAPTER 28: LUMBER YARDS AND AGRO-INDUSTRIAL, SOLID BIOMASS AND WOOD WORKING FACILITIES GENERAL COMMENTS PURPOSE SECTION 2801 GENERAL SECTION 2802 DEFINITIONS |
972 | SECTION 2803 GENERAL REQUIREMENTS |
973 | SECTION 2804 FIRE PROTECTION |
974 | SECTION 2805 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS SECTION 2806 LOG STORAGE AREAS SECTION 2807 STORAGE OF WOOD CHIPS AND HOGGED MATERIALS ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES |
975 | SECTION 2808 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIALS, FINES, COMPOST, SOLID BIOMASS FEEDSTOCK AND RAW PRODUCT ASSOCIATED WITH YARD WASTE, AGRO-INDUSTRIAL AND RECYCLING FACILITIES |
976 | SECTION 2809 EXTERIOR STORAGE OF FINISHED LUMBER AND SOLID BIOFUEL PRODUCTS |
977 | COMMENTARY FIGURE 2809.3 LUMBER YARD FIRE APPARATUS ACCESS ROADS |
978 | SECTION 2810 OUTDOOR STORAGE OF PALLETS AT PALLET MANUFACTURING AND RECYCLING FACILITIES |
979 | COMMENTARY FIGURE 2810.6 MAXIMUM CLEARANCE TO PROPERTY LINES AND IMPORTANT BUILDINGS |
980 | BIBLIOGRAPHY |
981 | CHAPTER 29: MANUFACTURE OF ORGANIC COATINGS GENERAL COMMENTS |
982 | PUROSE |
983 | SECTION 2901 GENERAL SECTION 2902 DEFINITION SECTION 2903 GENERAL PRECAUTIONS |
984 | SECTION 2904 ELECTRICAL EQUIPMENT AND PROTECTION |
985 | COMMENTARY FIGURE 2904.3 FLAMMABLE LIQUID BONDING AND GROUNDING |
986 | SECTION 2905 PROCESS STRUCTURES SECTION 2906 PROCESS MILLS AND KETTLES |
987 | SECTION 2907 PROCESS PIPING |
988 | SECTION 2908 RAW MATERIALS IN PROCESS AREAS SECTION 2909 RAW MATERIALS AND FINISHED PRODUCTS |
990 | BIBLIOGRAPHY |
991 | CHAPTER 30: INDUSTRIAL OVENS GENERAL COMMENTS PURPOSE SECTION 3001 GENERAL SECTION 3002 DEFINITIONS |
992 | SECTION 3003 LOCATION SECTION 3004 FUEL PIPING SECTION 3005 INTERLOCKS SECTION 3006 FIRE PROTECTION |
993 | SECTION 3007 OPERATION AND MAINTENANCE |
994 | BIBLIOGRAPHY |
995 | CHAPTER 31: TENTS, TEMPORARY SPECIAL EVENT STRUCTURES AND OTHER MEMBRANE STRUCTURES GENERAL COMMENTS CONSTRUCTION METHODS AND MATERIALS OCCUPANCY PURPOSE SECTION 3101 GENERAL |
996 | SECTION 3102 DEFINITIONS SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES |
999 | COMMENTARY FIGURE 3103.9.1(1) TWO-STORY MEMBRANE STRUCTURE AT THE AMERICA’S CUP RACE COMMENTARY FIGURE 3103.9.1(2) INTERIOR OF TWO-STORY MEMBRANE STRUCTURE |
1001 | TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS |
1002 | SECTION 3104 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES |
1003 | SECTION 3105 TEMPORARY SPECIAL EVENT STRUCTURES |
1004 | COMMENTARY FIGURE 3105.1(1) TEMPORARY STAGE CANOPY IN AN OUTDOOR SETTING |
1005 | COMMENTARY FIGURE 3105.1(2) TEMPORARY STAGE CANOPY AFTER STRUCTURAL COLLAPSE AT THE INDIANA STATE FAIR—AUGUST 13, 2011 |
1006 | SECTION 3106 OUTDOOR ASSEMBLY EVENTS |
1009 | SECTION 3107 OPERATIONAL REQUIREMENTS |
1014 | BIBLIOGRAPHY |
1015 | CHAPTER 32: HIGH-PILED COMBUSTIBLE STORAGE GENERAL COMMENTS PURPOSE SECTION 3201 GENERAL |
1017 | SECTION 3202 DEFINITIONS SECTION 3203 COMMODITY CLASSIFICATION COMMENTARY FIGURE 3203.1 CLASSIFICATION LEVELS |
1020 | TABLE 3203.8 EXAMPLES OF COMMODITY CLASSIFICATION |
1021 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1022 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1023 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1024 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1025 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1026 | TABLE 3203.8—continued EXAMPLES OF COMMODITY CLASSIFICATION |
1027 | FIGURE 3203.9(1) EVALUATION OF CARTONED COMMODITIES CONTAINING GROUP A PLASTICS FIGURE 3203.9(2) EVALUATION OF EXPOSED COMMODITIES CONTAINING GROUP A PLASTICS |
1028 | EQUATION 32-1 EQUATION 32-2 EQUATION 32-3 |
1029 | SECTION 3204 DESIGNATION OF HIGH-PILED STORAGE AREAS SECTION 3205 HOUSEKEEPING AND MAINTENANCE |
1030 | COMMENTARY FIGURE 3204.2 HIGHER HAZARD STORAGE ALLOWANCE |
1031 | COMMENTARY FIGURE 3205.8 SPRINKLER PENETRATION SECTION 3206 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES |
1033 | TABLE 3206.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS |
1034 | COMMENTARY FIGURE 3206.2.1(1) EXTENT OF PROTECTION COMMENTARY FIGURE 3206.2.1(2) EXTENT OF PROTECTION INCLUDING AISLES |
1037 | COMMENTARY FIGURE 3206.7.5 REQUIRED ACCESS DOORS |
1038 | COMMENTARY FIGURE 3206.10(1) HIGH-PILED STORAGE AREA |
1039 | COMMENTARY FIGURE 3206.10(2) HIGH-PILED STORAGE AREA (ALONG WALLS) COMMENTARY FIGURE 3206.10.1 CROSS AISLES |
1041 | COMMENTARY FIGURE 3206.10.2 RACK STORAGE (DOUBLE ROW) SECTION 3207 SOLID-PILED AND SHELF STORAGE |
1042 | COMMENTARY FIGURE 3207.1(1) PALLETIZED STORAGE ARRAY (COMMODITY CONFIGURED WITH FLUE SPACES) COMMENTARY FIGURE 3207.1(2) ENCAPSULATED COMMODITY COMMENTARY FIGURE 3207.1(3) ENCAPSULATED COMMODITY |
1043 | SECTION 3208 RACK STORAGE COMMENTARY FIGURE 3208.1 TYPICAL RACK SYSTEM |
1045 | COMMENTARY FIGURE 3208.2.2 DOUBLE-ROW RACKS WITH SOLID SHELVES |
1046 | TABLE 3208.3 REQUIRED FLUE SPACES FOR RACK STORAGE |
1047 | COMMENTARY FIGURE 3208.3(1) FLUE SPACES (OPTION 1 OF TABLE 3208.3 25 FEET OR LESS IN STORAGE HEIGHT) |
1048 | COMMENTARY FIGURE 3208.3(2) FLUE SPACES (OPTION 2 OF TABLE 3208.3 25 FEET OR LESS IN STORAGE HEIGHT) COMMENTARY FIGURE 3208.3(3) FLUE SPACES GREATER THAN 25 FEET IN STORAGE HEIGHT |
1049 | COMMENTARY FIGURE 3208.3(4) VERTICAL ALIGNMENT OF FLUE SPACES COMMENTARY FIGURE 3208.3.1 FLUE SPACE PROTECTION EXAMPLE SECTION 3209 AUTOMATED STORAGE |
1050 | SECTION 3210 SPECIALTY STORAGE |
1051 | BIBLIOGRAPHY |
1053 | CHAPTER 33: FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION GENERAL COMMENTS PURPOSE SECTION 3301 GENERAL SECTION 3302 DEFINITIONS |
1054 | SECTION 3303 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION |
1056 | COMMENTARY FIGURE 3303.5(1) PROTECTION OF TYPES IV-A, IV-B AND IV-C DURING CONSTRUCTION, EXAMPLE 1 |
1057 | COMMENTARY FIGURE 3303.5(2) PROTECTION OF TYPES IV-A, IV-B AND IV-C DURING CONSTRUCTION, EXAMPLE 2 SECTION 3304 TEMPORARY HEATING EQUIPMENT |
1058 | SECTION 3305 PRECAUTIONS AGAINST FIRE COMMENTARY FIGURE 3305.1 NO SMOKING SIGN |
1061 | SECTION 3306 FLAMMABLE AND COMBUSTIBLE LIQUIDS |
1062 | SECTION 3307 FLAMMABLE GASES SECTION 3308 EXPLOSIVE MATERIALS |
1063 | SECTION 3309 PORTABLE GENERATORS SECTION 3310 FIRE REPORTING SECTION 3311 ACCESS FOR FIRE FIGHTING SECTION 3312 MEANS OF EGRESS |
1064 | SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION |
1065 | SECTION 3314 STANDPIPES |
1066 | SECTION 3315 AUTOMATIC SPRINKLER SYSTEM SECTION 3316 PORTABLE FIRE EXTINGUISHERS |
1067 | SECTION 3317 MOTORIZED CONSTRUCTION EQUIPMENT SECTION 3318 SAFEGUARDING ROOFING OPERATIONS BIBLIOGRAPHY |
1069 | CHAPTER 34: TIRE REBUILDING AND TIRE STORAGE GENERAL COMMENTS PURPOSE |
1070 | SECTION 3401 GENERAL SECTION 3402 DEFINITIONS SECTION 3403 TIRE REBUILDING SECTION 3404 PRECAUTIONS AGAINST FIRE |
1071 | SECTION 3405 OUTDOOR STORAGE |
1072 | SECTION 3406 FIRE DEPARTMENT ACCESS SECTION 3407 FENCING SECTION 3408 FIRE PROTECTION |
1073 | SECTION 3409 INDOOR STORAGE ARRANGEMENT BIBLIOGRAPHY |
1075 | CHAPTER 35: WELDING AND OTHER HOT WORK GENERAL COMMENTS PURPOSE SECTION 3501 GENERAL |
1076 | SECTION 3502 DEFINITIONS SECTION 3503 GENERAL REQUIREMENTS |
1077 | SECTION 3504 FIRE SAFETY REQUIREMENTS |
1080 | SECTION 3505 GAS WELDING AND CUTTING COMMENTARY FIGURE 3505.2.1 TYPICAL WELDING CART |
1082 | SECTION 3506 ELECTRIC ARC HOT WORK |
1083 | SECTION 3507 CALCIUM CARBIDE SYSTEMS SECTION 3508 ACETYLENE GENERATORS |
1084 | SECTION 3509 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN |
1085 | SECTION 3510 HOT WORK ON FLAMMABLE AND COMBUSTIBLE LIQUID STORAGE TANKS BIBLIOGRAPHY |
1087 | CHAPTER 36: MARINAS GENERAL COMMENTS PURPOSE SECTION 3601 SCOPE SECTION 3602 DEFINITIONS SECTION 3603 GENERAL PRECAUTIONS |
1088 | SECTION 3604 FIRE PROTECTION EQUIPMENT |
1089 | SECTION 3605 MARINE MOTOR FUEL-DISPENSING FACILITIES |
1090 | BIBLIOGRAPHY |
1091 | CHAPTER 37: COMBUSTIBLE FIBERS GENERAL COMMENTS PURPOSE SECTION 3701 GENERAL SECTION 3702 DEFINITIONS SECTION 3703 GENERAL PRECAUTIONS |
1092 | SECTION 3704 LOOSE FIBER STORAGE |
1093 | SECTION 3705 BALED STORAGE |
1094 | BIBLIOGRAPHY |
1095 | CHAPTER 38: HIGHER EDUCATION LABORATORIES GENERAL COMMENTS PURPOSE |
1096 | SECTION 3801 GENERAL SECTION 3802 DEFINITIONS SECTION 3803 GENERAL SAFETY PROVISIONS |
1097 | COMMENTARY FIGURE 3803.1 COMPARISON OF THE STORAGE MAQ ALLOWANCES AND NUMBER OF CONTROL AREAS FOR CLASS IB FLAMMABLE LIQUIDS |
1098 | SECTION 3804 LABORATORY SUITE CONSTRUCTION |
1099 | TABLE 3804.1.1 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR |
1100 | SECTION 3805 NONSPRINKLERED LABORATORIES |
1102 | TABLE 3805.4 DESIGN AND NUMBER OF CONTROL AREAS IN EXISTING NONSPRINKLERED LABORATORIES SECTION 3806 EXISTING SPRINKLERED LABORATORIES |
1103 | TABLE 3806.2.1 DESIGN AND NUMBER OF CONTROL AREAS IN EXISTING SPRINKLERED LABORATORIES |
1105 | CHAPTER 39: PROCESSING AND EXTRACTION FACILITIES GENERAL COMMENTS PURPOSE SECTION 3901 GENERAL SECTION 3902 DEFINITIONS |
1106 | SECTION 3903 PROCESSING AND EXTRACTION SECTION 3904 SYSTEMS AND EQUIPMENT |
1108 | SECTION 3905 SAFETY SYSTEMS |
1109 | CHAPTER 40: STORAGE OF DISTILLED SPIRITS AND WINES GENERAL COMMENTS PURPOSE SECTION 4001 GENERAL SECTION 4002 DEFINITIONS SECTION 4003 PRECAUTIONS AGAINST FIRE |
1111 | SECTION 4004 STORAGE SECTION 4005 FIRE PROTECTION SECTION 4006 SIGNAGE |
1112 | COMMENTARY FIGURE 4006.1 HAZARD IDENTIFICATION SYMBOLS |
1113 | CHAPTERS 41 THROUGH 49: RESERVED |
1115 | PART V—HAZARDOUS MATERIALS CHAPTER 50: HAZARDOUS MATERIALS-GENERAL PROVISIONS GENERAL COMMENTS PURPOSE SECTION 5001 GENERAL |
1124 | SECTION 5002 DEFINITIONS |
1125 | SECTION 5003 GENERAL REQUIREMENTS |
1130 | TABLE 5003.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
1131 | TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p |
1132 | TABLE 5003.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p |
1133 | TABLE 5003.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD |
1134 | TABLE 5003.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA |
1135 | TABLE 5003.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREAa |
1141 | COMMENTARY FIGURE 5003.5 HAZARD IDENTIFICATION SYMBOLS COMMENTARY FIGURE 5003.5.1 HAZARD SYMBOLS |
1143 | TABLE 5003.8.2 DETACHED BUILDING REQUIRED COMMENTARY FIGURE 5003.8.3 CONTROL AREAS |
1144 | TABLE 5003.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS |
1145 | COMMENTARY FIGURE 5003.8.3.2(1) CONTROL AREA EXAMPLE |
1146 | COMMENTARY FIGURE 5003.8.3.2(2) COMMITTEE INTERPRETATIONS |
1147 | COMMENTARY FIGURE 5003.8.3.3 CONTROL AREAS IN A STRIP MALL |
1153 | TABLE 5003.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES—NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS |
1155 | SECTION 5004 STORAGE |
1157 | TABLE 5004.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE |
1162 | SECTION 5005 USE, DISPENSING AND HANDLING |
1166 | TABLE 5005.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE |
1168 | BIBLIOGRAPHY |
1169 | CHAPTER 51: AEROSOLS GENERAL COMMENTS PURPOSE SECTION 5101 GENERAL |
1170 | SECTION 5102 DEFINITIONS SECTION 5103 CLASSIFICATION OF AEROSOL PRODUCTS TABLE 5103.1 CLASSIFICATION OF AEROSOL PRODUCTS |
1171 | SECTION 5104 INSIDE STORAGE OF AEROSOL PRODUCTS |
1175 | TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb |
1176 | TABLE 5104.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN GENERAL PURPOSE WAREHOUSES |
1177 | TABLE 5104.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES |
1179 | TABLE 5104.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS, AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL STORAGE AREAS |
1180 | SECTION 5105 OUTSIDE STORAGE TABLE 5105.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS SECTION 5106 RETAIL DISPLAY |
1181 | TABLE 5106.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS, AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL DISPLAY AREAS |
1182 | COMMENTARY FIGURE 5106.3.2 GUIDE TO CONTENTS OF NFPA 30B TABLES 6.4.2.7 |
1183 | TABLE 5106.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS |
1184 | SECTION 5107 MANUFACTURING FACILITIES |
1185 | BIBLIOGRAPHY |
1187 | CHAPTER 52: RESERVED |
1189 | CHAPTER 53: COMPRESSED GASES GENERAL COMMENTS PURPOSE FLAMMABLE COMPRESSED GASES NONFLAMMABLE COMPRESSED GASES CONTAINER SUPPORTS OVERPRESSURE PROTECTION HOUSEKEEPING SEPARATION |
1190 | IGNITION SOURCES SECTION 5301 GENERAL SECTION 5302 DEFINITIONS SECTION 5303 GENERAL REQUIREMENTS |
1192 | COMMENTARY FIGURE 5303.4.1 STORAGE AND LABELING OF CYLINDERS |
1195 | COMMENTARY FIGURE 5303.7.11 TUBE TRAILER |
1199 | SECTION 5304 STORAGE OF COMPRESSED GASES SECTION 5305 USE AND HANDLING OF COMPRESSED GASES |
1200 | SECTION 5306 MEDICAL GASES |
1202 | SECTION 5307 COMPRESSED GASES NOT OTHERWISE REGULATED |
1204 | COMMENTARY FIGURE 5307.3(1) EXTERIOR FITTING TO FILL THE BULK CO2 CYLINDER INSIDE THE BUILDING COMMENTARY FIGURE 5307.3(2) BULK CO2 CYLINDER IN A CARBONATED BEVERAGE DISPENSING SYSTEM |
1206 | BIBLIOGRAPHY |
1207 | CHAPTER 54: CORROSIVE MATERIALS GENERAL COMMENTS PURPOSE SECTION 5401 GENERAL |
1208 | SECTION 5402 DEFINITION SECTION 5403 GENERAL REQUIREMENTS SECTION 5404 STORAGE SECTION 5405 USE |
1211 | CHAPTER 55: CRYOGENIC FLUIDS GENERAL COMMENTS PURPOSE SECTION 5501 GENERAL |
1212 | SECTION 5502 DEFINITIONS SECTION 5503 GENERAL REQUIREMENTS |
1216 | SECTION 5504 STORAGE |
1218 | TABLE 5504.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS |
1219 | TABLE 5504.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS SECTION 5505 USE AND HANDLING |
1221 | BIBLIOGRAPHY |
1223 | CHAPTER 56: EXPLOSIVES AND FIREWORKS GENERAL COMMENTS |
1224 | PURPOSE SECTION 5601 GENERAL |
1228 | TABLE 5601.8.1(1) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.1, 1.2 AND 1.5 EXPLOSIVES |
1229 | TABLE 5601.8.1(2) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.3 EXPLOSIVES TABLE 5601.8.1(3) APPLICATION OF QUANTITY-DISTANCE (Q-D) TABLES—DIVISION 1.4 EXPLOSIVES |
1230 | SECTION 5602 DEFINITIONS SECTION 5603 RECORD KEEPING AND REPORTING |
1231 | SECTION 5604 EXPLOSIVE MATERIALS STORAGE AND HANDLING |
1232 | TABLE 5604.3 STORAGE AMOUNTS AND MAGAZINE REQUIREMENTS FOR EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS, 1.3G MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA |
1235 | TABLE 5604.5.2(1) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a |
1236 | TABLE 5604.5.2(1)—continued AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991a |
1237 | TABLE 5604.5.2(2) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARD TABLE 5604.5.2(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4 |
1238 | COMMENTARY FIGURE 5604.6.5.2 AN EXAMPLE OF AN EXPLOSIVES PLACARD |
1241 | SECTION 5605 MANUFACTURE, ASSEMBLY AND TESTING OF EXPLOSIVES, EXPLOSIVE MATERIALS AND FIREWORKS |
1242 | TABLE 5605.3 MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa |
1243 | TABLE 5605.3—continued MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARDa |
1246 | SECTION 5606 SMALL ARMS AMMUNITION AND SMALL ARMS AMMUNITION COMPONENTS |
1250 | SECTION 5607 BLASTING |
1252 | COMMENTARY FIGURE 5607.15 RECOMMENDED WAITING PERIODS FOR INVESTIGATING MISFIRES SECTION 5608 FIREWORKS DISPLAY |
1254 | SECTION 5609 TEMPORARY STORAGE OF CONSUMER FIREWORKS |
1255 | BIBLIOGRAPHY |
1257 | CHAPTER 57: FLAMMABLE AND COMBUSTIBLE LIQUIDS GENERAL COMMENTS HAZARDOUS CHARACTERISTICS PHYSICAL CHARACTERISTICS HAZARDS PROTECTION |
1258 | PURPOSE SECTION 5701 GENERAL |
1260 | SECTION 5702 DEFINITIONS SECTION 5703 GENERAL REQUIREMENTS |
1261 | TABLE 5703.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa |
1262 | TABLE 5703.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa |
1264 | TABLE 5703.6.2 PIPING STANDARDS |
1267 | SECTION 5704 STORAGE |
1289 | TABLE 5704.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa |
1294 | TABLE 5704.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA |
1295 | TABLE 5704.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES TABLE 5704.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES |
1296 | TABLE 5704.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS |
1297 | TABLE 5704.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa |
1298 | TABLE 5704.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa |
1299 | TABLE 5704.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa TABLE 5704.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa |
1301 | TABLE 5704.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS |
1303 | TABLE 5704.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS |
1305 | SECTION 5705 DISPENSING, USE, MIXING AND HANDLING |
1308 | TABLE 5705.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES |
1309 | TABLE 5705.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 5705.3.4(1) |
1311 | COMMENTARY FIGURE 5705.3.6.2(1) PARTS CLEANING MACHINE WITH SOLVENT RESERVOIR COMMENTARY FIGURE 5705.3.6.2(2) PARTS CLEANING MACHINE WITHOUT SOLVENT RESERVOIR |
1315 | TABLE 5705.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS |
1318 | COMMENTARY FIGURE 5705.5 TOUCH-FREE ALCOHOL-BASED HAND RUB DISPENSER |
1319 | SECTION 5706 SPECIAL OPERATIONS |
1334 | COMMENTARY FIGURE 5706.6.1.11 TANK VEHICLE POSITIONING DURING UNLOADING |
1337 | SECTION 5707 ON-DEMAND MOBILE FUELING OPERATIONS |
1341 | BIBLIOGRAPHY |
1343 | CHAPTER 58: FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS GENERAL COMMENTS PURPOSE SECTION 5801 GENERAL |
1344 | SECTION 5802 DEFINITIONS SECTION 5803 GENERAL REQUIREMENTS |
1346 | SECTION 5804 STORAGE |
1347 | SECTION 5805 USE SECTION 5806 FLAMMABLE CRYOGENIC FLUIDS |
1350 | SECTION 5807 METAL HYDRIDE STORAGE SYSTEMS |
1352 | SECTION 5808 HYDROGEN FUEL GAS ROOMS |
1354 | BIBLIOGRAHY |
1355 | CHAPTER 59: FLAMMABLE SOLIDS GENERAL COMMENTS PURPOSE SECTION 5901 GENERAL |
1356 | SECTION 5902 DEFINITIONS SECTION 5903 GENERAL REQUIREMENTS SECTION 5904 STORAGE |
1357 | SECTION 5905 USE SECTION 5906 MAGNESIUM |
1359 | COMMENTARY FIGURE 5906.5.3 SCHEMATIC DIAGRAM OF WATER PRECIPITATION-TYPE COLLECTOR |
1361 | BIBLIOGRAPHY |
1363 | CHAPTER 60: HIGHLY TOXIC AND TOXIC MATERIALS GENERAL COMMENTS PURPOSE SECTION 6001 GENERAL |
1364 | SECTION 6002 DEFINITIONS SECTION 6003 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS |
1366 | SECTION 6004 HIGHLY TOXIC AND TOXIC COMPRESSED GASES |
1371 | TABLE 6004.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS |
1374 | COMMENTARY FIGURE 6004.3.2.1.1(1) FIRE BARRIER |
1375 | COMMENTARY FIGURE 6004.3.2.1.1(2) FIRE BARRIER LIMITATIONS |
1376 | COMMENTARY FIGURE 6004.3.2.1.2 OPENINGS |
1377 | SECTION 6005 OZONE GAS GENERATORS COMMENTARY FIGURE 6005.1 FEDERAL AGENCY OZONE STANDARDS |
1379 | BIBLIOGRAPHY |
1381 | CHAPTER 61: LIQUEFIED PETROLEUM GASES GENERAL COMMENTS PURPOSE SECTION 6101 GENERAL |
1382 | COMMENTARY FIGURE 6101.1(1) PROPERTIES OF COMMON LP-GASES COMMENTARY FIGURE 6101.1(2) VAPOR PRESSURES OF PROPANE |
1383 | SECTION 6102 DEFINITIONS SECTION 6103 INSTALLATION OF EQUIPMENT |
1384 | COMMENTARY FIGURE 6103.2.1 TYPICAL DOTn CYLINDERS |
1385 | SECTION 6104 LOCATION OF LP-GAS CONTAINERS |
1386 | TABLE 6104.3 LOCATION OF LP-GAS CONTAINERS |
1387 | COMMENTARY FIGURE 6104.3(1) LOCATION OF LPG CYLINDER/CONTAINER PER TABLE 6104.3 |
1388 | COMMENTARY FIGURE 6104.3(2) LOCATION OF DOTn AND ASME CONTAINERS COMMENTARY FIGURE 6104.3.1 TORCH-APPLIED ROOFING APPARATUS |
1389 | SECTION 6105 PROHIBITED USE OF LP-GAS SECTION 6106 DISPENSING AND OVERFILLING |
1390 | COMMENTARY FIGURE 6106.2 CYLINDER VALVE WITH OVERFILL PREVENTION DEVICE SECTION 6107 SAFETY PRECAUTIONS AND DEVICES SECTION 6108 FIRE PROTECTION |
1391 | SECTION 6109 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE |
1393 | TABLE 6109.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS |
1394 | COMMENTARY FIGURE 6109.13 INSTALLATION OF LP-GAS CONTAINERS FOR RETAIL SALE OR EXCHANGE |
1395 | SECTION 6110 LP-GAS CONTAINERS NOT IN SERVICE |
1396 | SECTION 6111 PARKING AND GARAGING OF LP-GAS TANK VEHICLES BIBLIOGRAPHY |
1397 | CHAPTER 62: ORGANIC PEROXIDES GENERAL COMMENTS PURPOSE SECTION 6201 GENERAL SECTION 6202 DEFINITION |
1398 | SECTION 6203 GENERAL REQUIREMENTS |
1399 | SECTION 6204 STORAGE COMMENTARY FIGURE 6204.1.1 TYPICAL DETACHED STORAGE STRUCTURE |
1400 | TABLE 6204.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS |
1401 | TABLE 6204.1.7 STORAGE OF ORGANIC PEROXIDES |
1402 | SECTION 6205 USE |
1403 | BIBLIOGRAPHY |
1405 | CHAPTER 63: OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS GENERAL COMMENTS PURPOSE |
1406 | SECTION 6301 GENERAL SECTION 6302 DEFINITIONS SECTION 6303 GENERAL REQUIREMENTS |
1408 | TABLE 6303.1.4 STORAGE OF CLASS 1, 2 AND 3 OXIDIZER LIQUIDS AND SOLIDS |
1409 | SECTION 6304 STORAGE |
1410 | TABLE 6304.1.5(1) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS TABLE 6304.1.5(2) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS TABLE 6304.1.5(3) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS |
1411 | TABLE 6304.2.1 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa |
1412 | SECTION 6305 USE SECTION 6306 LIQUID OXYGEN IN HOME HEALTH CARE |
1414 | BIBLIOGRAPHY |
1417 | CHAPTER 64: PYROPHORIC MATERIALS GENERAL COMMENTS |
1418 | PURPOSE SECTION 6401 GENERAL SECTION 6402 DEFINITION SECTION 6403 GENERAL REQUIREMENTS |
1419 | SECTION 6404 STORAGE |
1420 | TABLE 6404.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa |
1421 | SECTION 6405 USE BIBLIOGRAPHY |
1423 | CHAPTER 65: PYROXYLIN (CELLULOSE NITRATE) PLASTICS GENERAL COMMENTS PURPOSE SECTION 6501 GENERAL |
1424 | SECTION 6502 DEFINITIONS SECTION 6503 GENERAL REQUIREMENTS SECTION 6504 STORAGE AND HANDLING |
1426 | BIBLIOGRAPHY |
1427 | CHAPTER 66: UNSTABLE (REACTIVE) MATERIALS GENERAL COMMENTS PURPOSE SECTION 6601 GENERAL |
1428 | SECTION 6602 DEFINITION SECTION 6603 GENERAL REQUIREMENTS |
1429 | SECTION 6604 STORAGE |
1431 | SECTION 6605 USE BIBLIOGRAPHY |
1433 | CHAPTER 67: WATER-REACTIVE SOLIDS AND LIQUIDS GENERAL COMMENTS PURPOSE SECTION 6701 GENERAL |
1434 | SECTION 6702 DEFINITION SECTION 6703 GENERAL REQUIREMENTS SECTION 6704 STORAGE |
1436 | SECTION 6705 USE |
1437 | BIBLIOGRAPHY |
1439 | CHAPTERS 68 THROUGH 79: RESERVED |
1441 | PART VI—REFERENCED STANDARDS CHAPTER 80: REFERENCED STANDARDS GENERAL COMMENTS REFERENCED STANDARDS |
1442 | PURPOSE |
1443 | COMMENTARY FIGURE 80 REFERENCED STANDARDS |
1444 | AASHTO AFSI ANSI API |
1445 | ASCE/SEI ASHRAE ASME ASSP ASTM |
1447 | BHMA CA CGA |
1448 | CGR CPSC CSA DOC DOL |
1449 | DOTn DOTy EN FCC FM |
1450 | ICC |
1451 | IIAR IKECA ISO NEMA NFPA |
1455 | UL |
1458 | USC |
1459 | PART VII—APPENDICES APPENDIX A: BOARD OF APPEALS GENERAL COMMENTS PURPOSE SECTION A101 GENERAL |
1463 | APPENDIX B: FIRE-FLOW REQUIREMENTS FOR BUILDINGS GENERAL COMMENTS PURPOSE |
1464 | SECTION B101 GENERAL SECTION B102 DEFINITIONS SECTION B103 MODIFICATIONS |
1465 | SECTION B104 FIRE-FLOW CALCULATION AREA COMMENTARY FIGURE B104.1 FIRE-FLOW CALCULATION AREA = A WAREHOUSE + A LOADING DOCK |
1466 | SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS TABLE B105.1(1) REQUIRED FIRE FLOW FOR ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES |
1467 | TABLE B105.1(2) REFERENCE TABLE FOR TABLES B105.1(1) AND B105.2 |
1469 | TABLE B105.2 REQUIRED FIRE FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES SECTION B106 REFERENCED STANDARDS TABLE B106.1 REFERENCED STANDARDS BIBLIOGRAPHY |
1471 | APPENDIX C: FIRE HYDRANT LOCATIONS AND DISTRIBUTION GENERAL COMMENTS PURPOSE SECTION C101 GENERAL SECTION C102 NUMBER OF FIRE HYDRANTS |
1472 | TABLE C102.1 REQUIRED NUMBER AND SPACING OF FIRE HYDRANTSh |
1473 | COMMENTARY FIGURE C102.1(1) TRAVEL DISTANCE TO HYDRANTS COMMENTARY FIGURE C102.1(2) HYDRANT SPACING ALONG BOULEVARDS AND HIGH-VOLUME ARTERIAL STREETS SECTION C103 FIRE HYDRANT SPACING |
1474 | COMMENTARY FIGURE C103.1 HYDRANT SPACING SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS |
1475 | COMMENTARY FIGURE C103.2 AVERAGE HYDRANT SPACING COMMENTARY FIGURE C103.3 TRAVEL DISTANCE TO HYDRANTS |
1476 | SECTION C105 REFERENCED STANDARD TABLE C105.1 REFERENCED STANDARD |
1477 | APPENDIX D: FIRE APPARATUS ACCESS ROADS GENERAL COMMENTS PURPOSE SECTION D101 GENERAL SECTION D102 REQUIRED ACCESS SECTION D103 MINIMUM SPECIFICATIONS |
1478 | FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND |
1479 | TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS FIGURE D103.6 FIRE LANE SIGNS SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS |
1480 | SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS |
1481 | SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS |
1482 | SECTION D108 REFERENCED STANDARDS TABLE D108.1 REFERENCED STANDARDS BIBLIOGRAPHY |
1483 | APPENDIX E: HAZARD CATEGORIES GENERAL COMMENTS PURPOSE SECTION E101 GENERAL SECTION E102 HAZARD CATEGORIES |
1490 | SECTION E103 EVALUATION OF HAZARDS |
1494 | SECTION E104 REFERENCED STANDARDS TABLE E104.1 REFERENCED STANDARDS |
1495 | APPENDIX F: HAZARD RANKING GENERAL COMMENTS PURPOSE SECTION F101 GENERAL |
1496 | SECTION F102 REFERENCED STANDARDS TABLE F102.1 REFERENCED STANDARDS |
1497 | TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES |
1499 | APPENDIX G: CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS GENERAL COMMENTS PURPOSE SECTION G101 GENERAL |
1500 | TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS |
1503 | APPENDIX H: HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) AND HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INSTRUCTIONS GENERAL COMMENTS PURPOSE SECTION H101 HMMP |
1504 | SECTION H102 HMIS |
1505 | SECTION H103 EMERGENCY PLAN SECTION H104 SECURITY SECTION H105 REFERENCED STANDARDS TABLE H105.1 REFERENCED STANDARDS |
1506 | FIGURE H101.1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION |
1507 | FIGURE H101.2 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION |
1508 | FIGURE H101.3 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION I: FACILITY DESCRIPTION PART C—FACILITY MAP |
1509 | FIGURE H102.1 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) INVENTORY REPORT |
1510 | TABLE H102.1 SECTION II—HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) SUMMARY REPORT |
1511 | FIGURE H103.1 HAZARDOUS MATERIALS MANAGEMENT PLAN SECTION III: EMERGENCY PLAN |
1513 | APPENDIX I: FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS GENERAL COMMENTS PURPOSE SECTION I101 NONCOMPLIANT CONDITIONS |
1514 | SECTION I102 REFERENCED STANDARDS TABLE I102.1 REFERENCED STANDARDS |
1515 | APPENDIX J: BUILDING INFORMATION SIGN GENERAL COMMENTS PURPOSE SECTION J101 GENERAL |
1516 | FIGURE J101.1.3 EXAMPLE OF COMPLETED BUILDING INFORMATION SIGN |
1517 | SECTION J102 REFERENCED STANDARDS |
1518 | TABLE J102.1 REFERENCED STANDARDS |
1519 | APPENDIX K: CONSTRUCTION REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES GENERAL COMMENTS PURPOSE SECTION K101 GENERAL |
1520 | SECTION K102 FIRE SAFETY REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES |
1522 | SECTION K103 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES TABLE K103.1 INCIDENTAL USES IN EXISTING AMBULATORY CARE FACILITIES |
1523 | SECTION K104 MEANS OF EGRESS REQUIREMENTS FOR EXISTING AMBULATORY CARE FACILITIES |
1524 | SECTION K105 REFERENCED STANDARDS TABLE K105.1 REFERENCED STANDARDS |
1525 | APPENDIX L: REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS GENERAL COMMENTS PURPOSE SECTION L101 GENERAL |
1526 | SECTION L102 DEFINITIONS SECTION L103 PERMITS SECTION L104 DESIGN AND INSTALLATION |
1528 | COMMENTARY FIGURE L104.13.1 FILL STATION LOCATIONS |
1529 | SECTION L105 ACCEPTANCE TESTS SECTION L106 INSPECTION, TESTING AND MAINTENANCE |
1530 | SECTION L107 REFERENCED STANDARDS TABLE L107.1 REFERENCED STANDARDS |
1531 | APPENDIX M: HIGH-RISE BUILDINGS—RETROACTIVE AUTOMATIC SPRINKLER REQUIREMENT GENERAL COMMENTS PURPOSE SECTION M101 SCOPE SECTION M102 WHERE REQUIRED |
1532 | SECTION M103 COMPLIANCE |
1533 | APPENDIX N: INDOOR TRADE SHOWS AND EXHIBITIONS GENERAL COMMENTS PURPOSE SECTION N101 GENERAL |
1534 | SECTION N102 DEFINITIONS SECTION N103 PUBLIC SAFETY FOR EVENTS SECTION N104 INTERIOR FINISH AND DECORATIVE MATERIALS |
1535 | SECTION N105 MULTIPLE-LEVEL BOOTHS SECTION N106 COVERED BOOTHS SECTION N107 DISPLAY AND STORAGE OF HAZARDOUS AND COMBUSTIBLE MATERIALS |
1537 | SECTION N108 MEANS OF EGRESS SECTION N109 REFERENCED STANDARDS TABLE N109.1 REFERENCED STANDARDS |
1539 | INDEX |
1569 | RESOURCE A RECOMMENDED PRACTICES FORREMOTE VIRTUAL INSPECTIONS (RVI) |
1571 | RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSTPECTIONS (RVI) |
1572 | COPYRIGHT |
1573 | TABLE OF CONTENTS |
1575 | PREFACE |
1576 | ABOUT THE INTERNATIONAL CODE COUNCIL® |
1577 | 1.0 INTRODUCTION PURPOSE AND SCOPE 2.0 DEFINITIONS AND ACRONYMS 3.0 REMOTE VIRTUAL INSPECTION PROCESS |
1578 | CUSTOMER: REQUESTING A REMOTE VIRTUAL INSPECTION |
1579 | AHJ: SCHEDULING REMOTE VIRTUAL INSPECTION |
1580 | CUSTOMER: PREPARE FOR REMOTE VIRTUAL INSPECTION CUSTOMER: PREPARE TO RECEIVE REMOTE VIRTUAL INSPECTION CALL |
1581 | WHAT TO EXPECT DURING THE INSPECTION INSPECTION RESULTS |
1582 | MAINTAINING RECORDS OF INSPECTIONS 4.0 TRAINING AND COMMUNICATION STAFF TRAINING |
1583 | CUSTOMER/APPLICANT ADDITIONAL CONSIDERATIONS |
1584 | 5.0 APPENDIX A (EXAMPLES OF POTENTIAL ACTIVITIES) |
1585 | KEYS TO SUCCESS FOR REMOTE VIRTUAL INSPECTIONS WHAT ARE REMOTE VIRTUAL INSPECTIONS (RVI)? RVI BENEFITS THE FOUNDATION OF SUCCESS: TRAINING AND COMMUNICATION |
1586 | THE KEY STEPS TO A REMOTE VIRTUAL INSPECTION |
1587 | ADDITIONAL CODE RESOURCES FROM ICC |
1588 | PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™) |
1589 | ICC LEARNING CENTER |
1590 | ICC DIGITAL CODES PREMIUM |