Shopping Cart

No products in the cart.

IPC Commentary 09 2009

$61.21

International Plumbing Code and Commentary

Published By Publication Date Number of Pages
ICC 2009 560
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

 A practical tool that helps you to master the code you deal with every day!

This comprehensive publication provides a convenient reference for regulations in the 2009  International Plumbing Code® (IPC®).
 
Presented in an easy-to-reference format the commentary includes the full text of the code, including tables and figures, followed by corresponding commentary at the end of each section in one document. Every chapter begins with “General Comments” and “Purpose” sections followed by code and commentary to subsequent sections, tables and figures. This in-depth publication focuses on providing the full meaning and implications of the 2009 IPC®.
 
The commentaries are designed to suggest the most effective method of application, and the consequences of not adhering to the code. This is an excellent reference for code officials, engineers, architects, inspectors, plans examiners, contractors and anyone who needs a better understanding of the 2009 IPC®.

PDF Catalog

PDF Pages PDF Title
1 2009 INTERNATIONAL PLUMBING CODE AND COMMENTARY
2 COPYRIGHT
3 PREFACE
5 TABLE OF CONTENTS
7 CHAPTER 1: SCOPE AND ADMINISTRATION
GENERAL COMMENTS
PURPOSE
PART 1 – SCOPE AND APPLICATION
SECTION 101 – GENERAL
8 SECTION 102 – APPLICABILITY
11 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 – DEPARTMENT OF PLUMBING INSPECTION
SECTION 104 – DUTIES AND POWERS OF THE CODE OFFICIAL
13 SECTION 105 – APPROVAL
15 SECTION 106 – PERMITS
19 SECTION 107 – INSPECTIONS AND TESTING
22 SECTION 108 – VIOLATIONS
24 SECTION 109 – MEANS OF APPEAL
26 SECTION 110 – TEMPORARY EQUIPMENT, SYSTEMS AND USES
BIBLIOGRAPHY
27 CHAPTER 2: DEFINITIONS
GENERAL COMMENTS
PURPOSE
SECTION 201 – GENERAL
SECTION 202 – GENERAL DEFINITIONS
29 FIGURE 202(1) AIR ADMITTANCE VALVE OPENS
FIGURE 202(2) AIR ADMITTANCE VALVE CLOSES
30 FIGURE 202(3) MECHANICAL VENT
FIGURE 202(4) AIR GAP, AIR BREAK
34 FIGURE 202(5) DEFINITION OF A BRANCH INTERVAL
35 FIGURE 202(6) BRANCH INTERVALS
36 FIGURE 202(7) BRANCH VENT
FIGURE 202(8) DRAINAGE SYSTEM COMPONENTS
39 FIGURE 202(9) DEPTH OF TRAP SEAL
41 FIGURE 202(10) FIXTURE DRAINS AND FIXTURE BRANCHES
FIGURE 202(11) FIXTURE DRAIN
43 FIGURE 202(12) SENSOR-CONTROLLED GREASE RECOVERY DEVICE
44 FIGURE 202(13) TIMER-CONTROLLED GREASE RECOVERY DEVICE
FIGURE 202(14) GREASE REMOVAL DEVICE, AUTOMATIC
45 FIGURE 202(15) TYPES OF WATER DISTRIBUTION SYSTEMS
49 FIGURE 202(16) PARTS OF A PLUMBING SYSTEM
55 BIBLIOGRAPHY
57 CHAPTER 3: GENERAL REGULATIONS
GENERAL COMMENTS
PURPOSE
SECTION 301 – GENERAL
58 SECTION 302 – EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 – MATERIALS
59 TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
SECTION 304 – RODENTPROOFING
60 FIGURE 303.4(1) SAMPLE MARKING OF PVC PRESSURE
FIGURE 303.4(2) MARKING OF PVC GRAVITY SEWER PIPE
61 SECTION 305 – PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
TABLE 305.3 THERMAL EXPANSION RATES FOR PIPING MATERIALS
EQUATION – DETERMINING LENGTH OF L
62 FIGURE 305.3(1) “L” BEND
FIGURE 305.3(2) “Z” BEND
63 FIGURE 305.3(3) “U” BEND
64 FIGURE 305.5(1) PIPE PROTECTION
FIGURE 305.5(2) BUILDING DRAIN PENETRATION THROUGH FOUNDATION WALL
65 FIGURE 305.6(1) PROTECTION AGAINST FREEZING
FIGURE 305.6(2) WATER DISTRIBUTION PIPING IN EXTERIOR WALL
66 FIGURE 305.6(3) PIPING IN EXTERIOR WALL
67 FIGURE 305.6(4) TYPICAL FREEZEPROOF HOSE FAUCET INSTALLATION
FIGURE 305.6(5) SEVERE FROST PENETRATION LEVELS
68 FIGURE 305.6(6) REQUIRED BURIAL DEPTH
FIGURE 305.7 ROOF PENETRATIONS
69 FIGURE 305.8(1) REQUIRED SHIELD PLATES
70 FIGURE 305.8(2) PIPE PROTECTION VIOLATION
FIGURE 305.9 PROTECTION OF PLUMBING SYSTEM COMPONENTS
SECTION 306 – TRENCHING, EXCAVATION AND BACKFILL
71 FIGURE 306.2 PIPE ON BOTTOM OF TRENCH
FIGURE 306.2.1 OVEREXCAVATED TRENCH
72 FIGURE 306.3 TAMPING LOOSE FILL IN 6 INCH LAYERS
SECTION 307 – STRUCTURAL SAFETY
74 FIGURE 307.2(1) CUTTING, NOTCHING AND BORING OF WALL STUDS
FIGURE 307.2(2) CUTTING, NOTCHING AND BORING OF FLOOR JOISTS, CEILING JOISTS AND RAFTERS
FIGURE 307.2(3) NOTCHING AND BORING IN A WOOD BEARING WALL
75 FIGURE 307.2(4) VIOLATION: NOTCH IN FLOOR JOIST TOO DEEP
FIGURE 307.2(5) VIOLATION: HOLES TOO CLOSE TO BOTTOM OF JOIST
FIGURE 307.2(6) VIOLATION: NOTCHES TOO DEEP IN WALL STUDS
76 FIGURE 307.2(7) VIOLATION: EXTERIOR WALL STUD NOTCHED TOO DEEP
FIGURE 307.2(8) VIOLATION: FLOOR JOIST COMPLETELY SEVERED
FIGURE 307.2(9) VIOLATION: EXTERIOR WALL STUD COMPLETELY SEVERED
77 FIGURE 307.2(10) REQUIRED TOP PLATES REINFORCEMENT
78 FIGURE 307.2(11) VIOLATION: WALL TOP PLATES NOT REINFORCED
FIGURE 307.2(12) LAMINATED VENEER LUMBER BEAM
79 FIGURE 307.2(13) VIOLATION: TOP CHORD OF TRUSS NOTCHED
FIGURE 307.2(14) VIOLATION: HOLE IN BOTTOM CHORD OF ROOF TRUSS
FIGURE 307.2(15) VIOLATION: TOP CHORD OF I-JOISTCOMPLETELY SEVERED
FIGURE 307.2(16) VIOLATION: I-JOIST WEB HOLES IRREGULAR SHAPE, TOO LARGE, TOO CLOSE TOGETHER
80 FIGURE 307.2(17) STRUCTURAL STEEL BEAM
FIGURE 307.2(18) FLANGE, LIP AND WEB OF COLD-FORMED STEEL LIGHT FRAME MEMBER
FIGURE 307.2(19) ALLOWABLE WEB HOLES IN STUDS (PRESCRIPTIVE DESIGN ONLY)
81 FIGURE 307.2(20) ALLOWABLE WEB HOLES IN MEMBERS OTHER THAN STUDS
FIGURE 307.2(21) ALLOWABLE NOTCHING AND BORING OF STRUCTURAL LOG MEMBERS
82 FIGURE 307.3(1) COMBUSTIBLE PIPE PENETRATION OF FIRE-RATED WALL
FIGURE 307.3(2) ANNULAR SPACE PROTECTION
FIGURE 307.3(3) PIPE PENETRATION OF FIRE-RESISTANCE-RATED ROOF/CEILING ASSEMBLY
FIGURE 307.3(4) PIPE PENETRATION OF FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY
83 FIGURE 307.4 VIOLATION: TOP CHORD OF FLOOR TRUSS REMOVED
FIGURE 307.5 EXCAVATION IN RELATION TO FOOTING
84 SECTION 308 – PIPING SUPPORT
FIGURE 308.3(1) PLASTIC HANGER STRAP
85 FIGURE 308.3(2) PLASTIC INSERT FOR COPPER TUBING THROUGH METAL STUD (Photo Courtesy of Holdrite-Hubbard Enterprises)
FIGURE 308.4 POOR HANGER ATTACHMENT
TABLE 308.5 HANGER SPACING
86 FIGURE 308.5(1) POINT OF SAG BETWEEN HANGERS
FIGURE 308.5(2) LOCATION OF HANGERS
87 FIGURE 308.6 SWAY BRACING
FIGURE 308.7 RESTRAINED COUPLING
88 FIGURE 308.7.1 ANCHORAGE LOCATION
89 FIGURE 308.9(1) PIPE SUPPORT
FIGURE 308.9(2) PIPE BEND SUPPORT MAINTAINING BEND RADIUS (Photo courtesy of Holdrite-Hubbard Enterprises)
FIGURE 308.9(3) PIPE BEND SUPPORT MAINTAINING BEND RADIUS (Photo courtesy of Holdrite-Hubbard Enterprises)
90 FIGURE 308.9(4) PIPE BEND SUPPORT MAINTAINING BEND RADIUS (Photo courtesy of Holdrite-Hubbard Enterprises)
SECTION 309 – FLOOD HAZARD RESISTANCE
91 SECTION 310 – WASHROOM AND TOILET ROOM REQUIREMENTS
FIGURE 310.2 FIXTURE AND PIPING OBSTRUCTIONS
92 FIGURE 310.5(1) URINAL PARTITIONS (Photo courtesy of Falcon Waterfree Technologies)
93 FIGURE 310.5(2) URINAL PARTITIONS
SECTION 311 – TOILET FACILITIES FOR WORKERS
TABLE 311.1 MINIMUM NUMBER OF TOILET FACILITIES
SECTION 312 – TESTS AND INSPECTIONS
95 FIGURE 312.4(1) SMOKE GENERATING EQUIPMENT (Photo courtesy of Hurco Technologies, Inc.)
96 FIGURE 312.4(2) SMOKE INDICATING PRESENCE OF LEAK (Photo courtesy of Hurco Technologies, Inc.)
98 FIGURE 312.9 TESTING OF FIELD FABRICATED SHOWER LINER
SECTION 313 – EQUIPMENT EFFICIENCIES
SECTION 314 – CONDENSATE DISPOSAL
99 TABLE [M] 314.2.2 CONDENSATE DRAIN SIZING
100 FIGURE 314.2.3(1) CONDENSATE OVERFLOW SWITCH (Photo courtesy of SMD Research, Inc.)
101 FIGURE 314.2.3(2) CONDENSATE OVERFLOW SWITCH (Photo courtesy of SMD Research, Inc.)
FIGURE 314.2.3(3) PRIMARY OR AUXILIARY DRAIN PAN FLOAT SWITCH (Photo courtesy of SMD Research, Inc.)
FIGURE 314.2.3.2 FURNACE ELEVATED ABOVE TOP OF CONDENSATE PAN
102 BIBLIOGRAPHY
103 CHAPTER 4: FIXTURE, FAUCETS AND FIXTURE FITTINGS
GENERAL COMMENTS
PURPOSE
SECTION 401 – GENERAL
104 SECTION 402 – FIXTURE MATERIALS
105 SECTION 403 – MINIMUM PLUMBING FACILITIES
108 TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.2 and 403.3)
109 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.2 and 403.3
110 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 403.2 and 403.3)
113 TABLE 403.1(1) SOLUTION SUMMARY FOR SAMPLE PROBLEM 1
114 TABLE 403.1(2) SOLUTION SUMMARY OF SAMPLE PROBLEM 2
115 TABLE 403.1(3) SOLUTION SUMMARY FOR SAMPLE PROBLEM 3
116 TABLE 403.1(4) SOLUTION SUMMARY FOR SAMPLE PROBLEM 4
TABLE 403.1(5) BUILDING PLUMBING FIXTURE TOTALS FOR SAMPLE PROBLEM 4
118 FIGURE 403.3 RESTAURANT ENTRY SIGN
FIGURE 403.3.1(1) WALK-UP ICE CREAM SHOP WITH OUTDOOR SEATING
119 FIGURE 403.3.1(2) CUSTOMER TOILET ACCESS
121 SECTION 404 – ACCESSIBLE PLUMBING FACILITIES
123 FIGURE 404(1) WATER CLOSET LOCATIONS
FIGURE 404(2) WATER CLOSET HEIGHT
FIGURE 404(3) SIZE OF CLEARANCE FOR WATER CLOSET
FIGURE 404(4) REAR WALL GRAB BAR FOR WATER CLOSET
124 FIGURE 404(5) SIDE WALL GRAB BAR FOR WATER CLOSET
FIGURE 404(6) INTERNATIONAL SYMBOL FOR ACCESSIBILITY
FIGURE 404(7) CHILDREN’S WATER CLOSET LOCATION
125 FIGURE 404(8) CHILDREN’S WATER CLOSET HEIGHT AND SIDE WALL GRAB BARS
FIGURE 404(9) WALL HUNG TYPE URINAL
FIGURE 404(10) ACCESSIBLE HEIGHT URINAL ON LEFT
126 FIGURE 404(11) BATHTUB WITHOUT PERMANENT SEAT
FIGURE 404(12) BATHTUB WITH PERMANENT SEAT
FIGURE 404(13) GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 404(14) GRAB BARS FOR BATHTUBS WITHOUT PERMANENT SEATS
127 FIGURE 404(15) LOCATION OF BATHTUB CONTROLS
FIGURE 404(16) TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
128 FIGURE 404(17) GRAB BARS IN TRANSFER-TYPE SHOWERS
FIGURE 404(18) TRANSFER-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION
FIGURE 404(19) STANDARD ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
129 FIGURE 404(20) GRAB BARS IN ALTERNATE ROLL-IN-TYPE SHOWERS
FIGURE 404(21) STANDARD ROLL-IN-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION
FIGURE 404(22) ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
130 FIGURE 404(23) GRAB BARS IN ALTERNATE ROLL-IN SHOWERS
FIGURE 404(24) ALTERNATE ROLL-IN-TYPE SHOWER CONTROL AND HAND SHOWER LOCATION
131 FIGURE 404(25) CONTROLS AND HAND SHOWER IN ACCESSIBLE SHOWER (Photo courtesy of B&I Contractors, Inc.)
133 FIGURE 404(26) HEIGHT OF LAVATORIES AND SINKS
FIGURE 404(27) KNEE CLEARANCE
FIGURE 404(28) WALL MOUNTED ACCESSIBLE LAVATORY
134 FIGURE 404(29) TOE CLEARANCE
FIGURE 404(30) ACCESSIBLE KITCHEN SINK
135 FIGURE 404(31) ACCESSIBLE DRINKING FOUNTAIN
137 FIGURE 404(32) SWING UP GRAB BAR FOR WATER CLOSET
138 FIGURE 404(33) PARALLEL APPROACH BATHTUB IN TYPE B UNITS
FIGURE 404(34) FORWARD APPROACH BATHTUB IN TYPE B UNITS
141 SECTION 405 – INSTALLATION OF FIXTURES
FIGURE 405.3.1 – FIXTURE CLEARANCE
143 FIGURE 405.3.1(1) MINIMUM CLEARANCE BETWEEN FIXTURES
144 FIGURE 405.3.1(2) CORNER SINK USER CLEARANCE
145 FIGURE 405.4 WATER CLOSET FLOOR FLANGE
146 FIGURE 405.4.3 WALL-HUNG WATER CLOSET
FIGURE 405.5(1) JOINTS BETWEEN FIXTURES AND WALLS OR FLOORS
FIGURE 405.5(2) VIOLATION: LAVATORY NOT ATTACHED OR SEALED TO WALL
FIGURE 405.5(3) LAVATORY PROPERLY SEALED TO WALL
147 FIGURE 405.7 FIXTURE OVERFLOW
SECTION 406 – AUTOMATIC CLOTHES WASHERS
148 FIGURE 406.3 CLOTHES WASHER TRENCH DRAIN
149 SECTION 407 – BATHTUBS
150 SECTION 408 – BIDETS
SECTION 409 – DISHWASHING MACHINES
151 SECTION 410 – DRINKING FOUNTAINS
152 SECTION 411 – EMERGENCY SHOWERS AND EYEWASH STATIONS
FIGURE 411.1 EMERGENCY SHOWER AND EYEWASH STATION (Photo Courtesy of B&I Contractors, Inc.)
153 SECTION 412 – FLOOR AND TRENCH DRAINS
FIGURE 412.1 TRENCH DRAIN (Photo Courtesy of B&I Contractors, Inc.)
154 FIGURE 412.2(1) TYPICAL FLOOR DRAIN WITHOUT INTEGRAL TRAP
FIGURE 412.2(2) TYPICAL FLOOR DRAIN WITH INTEGRAL TRAP
155 SECTION 413 – FOOD WASTE GRINDER UNITS
FIGURE 413.3 – COMMERCIAL FOOD WASTE GRINDER
156 SECTION 414 – GARBAGE CAN WASHERS
FIGURE 414.2 GARBAGE CAN WASHER
SECTION 415 – LAUNDRY TRAYS
157 SECTION 416 – LAVATORIES
FIGURE 416.1 GROUP WASH-UP FIXTURE
158 FIGURE 416.4 ADJUSTABLE HEIGHT SHAMPOO BOWL (Photo Courtesy of Accessible Systems LLC)
SECTION 417 – SHOWERS
159 FIGURE 417.2(1) SECURING SHOWER RISER
FIGURE 417.2(2) SPECIAL BRACKET FOR SHOWER RISER (Photo Courtesy of Holdrite-Hubbard Enterprises
160 FIGURE 417.3 SHOWER FLOOR DESIGN
FIGURE 417.4 SHOWER COMPARTMENT
161 FIGURE 417.5.2 SHOWER LINING CONNECTION
162 SECTION 418 – SINKS
163 SECTION 419 – URINALS
FIGURE 419.1(1) WATERLESS URINAL (Photo Courtesy of Falcon Waterfree Technologies
164 FIGURE 419.1(2) WATERLESS URINAL CARTRIDGE (Photo Courtesy of Falcon Waterfree Technologies
FIGURE 419.3 URINAL SURROUNDING MATERIAL
SECTION 420 – WATER CLOSETS
165 FIGURE 420.1(1) BOWL DESIGN
166 FIGURE 420.1(2) FLUSHING ACTION FOR CERTAIN WATER CLOSETS
FIGURE 420.1(3) DETERMINING WATER CLOSET RIM HEIGHT
FIGURE 420.4 ACCEPTABLE 4 X 3 CLOSET BENDS
167 SECTION 421 – WHIRLPOOL BATHTUBS
SECTION 422 – HEALTH CARE FIXTURES AND EQUIPMENT
168 FIGURE 421.5(1) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS
FIGURE 421.5(2) NONCOMPLIANT WHIRLPOOL BATHTUB PUMP ACCESS
170 SECTION 423 – SPECIALTY PLUMBING FIXTURES
SECTION 424 – FAUCETS AND OTHER FIXTURE FITTINGS
172 FIGURE 424.1.1(1) AERATED STREAM AERATOR (Photo courtesy of Neoperl, Inc.)
FIGURE 424.1.1(2) SPRAY AERATOR (Photo courtesy of Neoperl, Inc.)
173 TABLE 424.3 TEMPERATURE BURN CHART
175 TABLE 424.4 MAXIMUM TEMPERATURES ALLOWED AT USE LOCATIONS
FIGURE 424.4 TEMPERATURE CONTROL STANDARDS RELATED TO FIXTURE APPLICATIONS
177 SECTION 425 – FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
178 SECTION 426 – MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 427 – FLOOR SINKS
BIBLIOGRAPHY
181 CHAPTER 5: WATER HEATERS
GENERAL COMMENTS
PURPOSE
SECTION 501 – GENERAL
182 FIGURE 501.2 WATER-TO-AIR HEAT EXCHANGER
185 FIGURE 501.6(1) TYPICAL CAPACITY GRAPH FOR TANKLESS WATER
FIGURE 501.6(2) TYPICAL DETERMINATION OF FLOW AT GIVEN TEMPERATURE RISE
TABLE 501.6(1) TYPICAL CAPACITY TABLE FOR TANKLESS WATER HEATERS
187 SECTION 502 – INSTALLATION
189 SECTION 503 – CONNECTIONS
190 FIGURE 503.1(1) WATER HEATER VALVE
FIGURE 503.1(2) PLASTIC PIPE TOO CLOSE TO DRAFT HOOD OF GAS-FIRED WATER HEATER
FIGURE 503.2 CIRCULATING TYPE WATER HEATERS CONNECTED TO STORAGE TANKS (Photo courtesy of B&I Contractors, Inc.)
191 SECTION 504 – SAFETY DEVICES
FIGURE 504.2 WATER HEATER WITH BOTTOM FEED
192 FIGURE 504.3 ELECTRIC DISCONNECT ADJACENT TO WATER HEATER (Photo courtesy of B&I Contractors, Inc.)
193 FIGURE 504.4 COMBINATION TEMPERATURE AND PRESSURE-RELIEF VALVE (Photo courtesy of CASH-ACME, Inc.)
FIGURE 504.4.1 TEMPERATURE- AND PRESSURE-RELIEF VALVE INSTALLATION
194 FIGURE 504.5 COMBINATION TEMPERATURE- AND PRESSURE-RELIEF VALVE LABEL (Photo courtesy of CASH-ACME, Inc.)
195 FIGURE 504.6(1) RELIEF VALVE DISCHARGE
196 FIGURE 504.6(2) RELIEF VALVE INDIRECT WASTE
197 FIGURE 504.6(3) T&P RELIEF VALVE PERMITTED TO DISCHARGE TO THE PAN
198 FIGURE 504.6(4) CAPPED TANK TAPPING FOR RELIEF VALVE AND PLUGGED RELIEF VALVE OPENING
FIGURE 504.7(1) WATER HEATER IN PAN
199 SECTION 505 – INSULATION
200 BIBLIOGRAPHY
201 CHAPTER 6: WATER SUPPLY AND DISTRIBUTION
GENERAL COMMENTS
PURPOSE
SECTION 601 – GENERAL
202 SECTION 602 – WATER REQUIRED
203 SECTION 603 – WATER SERVICE
204 FIGURE 603.1(1) RESIDENTIAL WATER SERVICE SCHEMATIC
205 TABLE 603.1 TABLE FOR ESTIMATING DEMAND
206 FIGURE 603.1(2) FRICTION LOSS IN SMOOTH PIPEa (Type L, ASTM B 88 Copper Tubing
207 TABLE 603.2.1 MINIMUM HORIZONTAL SEPARATION DISTANCES BETWEEN WATER SOURCE ELEMENTS AND SOIL ABSORPTION SYSTEM COMPONENTS
208 FIGURE 603.2(1) SEPARATION OF WATER SERVICE AND BUILDING SEWER
FIGURE 603.2(2) WATER SERVICE CROSSING OVER BUILDING SEWER
209 SECTION 604 – DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
210 FIGURE 604.1(1) DIFFERENCE IN ELEVATION
FIGURE 604.1(2) DIFFERENCE IN ELEVATION
211 FIGURE 604.1(3) CAVITATION
TABLE 604.1 MAXIMUM FLOW VELOCITY
213 TABLE 604.3 PEAK DEMAND PERIODS
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
215 TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
216 FIGURE 604.5 WATER SUPPLY CONNECTION WITH REDUCED-SIZE FLEXIBLE SUPPLY
217 FIGURE 604.9(1) EXAMPLE OF MECHANICAL WATER-HAMMER ARRESTORS
218 FIGURE 604.9(2) AIR CHAMBER WATER HAMMER ARRESTOR
TABLE 604.10.1 MANIFOLD SIZING
219 FIGURE 604.10(1) FIELD-BUILT MANIFOLD FOR PARALLEL WATER DISTRIBUTION
FIGURE 604.10(2) FACTORY-BUILT MANIFOLD FOR PARALLEL WATER DISTRIBUTION
220 SECTION 605 – MATERIALS, JOINTS AND CONNECTIONS
221 FIGURE 605.3(1) PLASTIC WATER SERVICE EXTENDING INTO BUILDING
222 TABLE 605.3 WATER SERVICE PIPE
224 TABLE 605.3 DUCTILE IRON PIPE LINING THICKNESS
225 FIGURE 605.3(3) SAMPLE MARKING OF PEX TUBING
227 TABLE 605.4 WATER DISTRIBUTION PIPE
228 TABLE 605.5 PIPE FITTINGS
229 TABLE 605.8 MANUFACTURED PIPE NIPPLES
231 FIGURE 605.11 ASBESTOS-CEMENT PIPE JOINT
FIGURE 605.12.1 HEAT APPLICATION OF BRAZED JOINT
233 FIGURE 605.14.3 PREPARATION OF PIPE END
234 FIGURE 605.15.2(1) TYPICAL FLARED TUBE JOINT
FIGURE 605.15.2(2) TYPICAL FLARED TUBE JOINT
236 FIGURE 605.17.2 PEX TUBING CONNECTION
237 FIGURE 605.19.4 BENDING
239 TABLE 605.24.1 CORROSIVE HIERARCHY OF METALS (Galvanic Series)
FIGURE 605.24.1(1) DIELECTRIC UNION
FIGURE 605.24.1(2) DIELECTRIC FLANGE FITTING
240 FIGURE 605.24.1(3) CORROSION DUE TO ABSENCE OF DIELECTRIC FITTINGS
SECTION 606 – INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
241 FIGURE 606.1(1) CURB VALVE ON WATER SUPPLY
FIGURE 606.1(2) VALVE AT ENTRANCE TO THE BUILDING AND ON THE DISCHARGE SIDE OF METER
242 FIGURE 606.1(3) VALVES FOR EACH RISER AND DOWNFEED
FIGURE 606.1(4) DWELLING UNIT VALVE
FIGURE 606.1(5) VALVES ON SUPPLY TO EACH TANK
243 FIGURE 606.1(6) WATER HEATER VALVE
FIGURE 606.2(1) SHUTOFF VALVES FOR EACH FIXTURE
244 FIGURE 606.2(2) SILL FAUCET VALVE
245 TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
246 SECTION 607 – HOT WATER SUPPLY SYSTEM
247 FIGURE 607.2 – HOT WATER SUPPLY TEMPERATURE MAINTENANCE
248 FIGURE 607.2.3(1) PROPER RECIRCULATION RETURN
249 FIGURE 607.2.3(2) PROHIBITED RECIRCULATION RETURN
FIGURE 607.2.3(3) PROHIBITED RECIRCULATION RETURN
250 FIGURE 607.3 EXAMPLE METHOD OF THERMAL EXPANSION CONTROL
251 FIGURE 607.3.1 PRESSURE-REDUCING VALVE WITH THERMAL EXPANSION BYPASS
253 SECTION 608 – PROTECTION OF POTABLE WATER SUPPLY
FIGURE 608.1(1) ATMOSPHERIC PRESSURE
254 FIGURE 608.1(2) PRESSURE EXERTED BY 1 CUBIC FOOT OF WATER
255 FIGURE 608.1(3) PRESSURE EXERTED BY A COLUMN OF WATER
FIGURE 608.1(4) BASE PRESSURE
FIGURE 608.1(5) COLUMN OF WATER EXPOSED TO ATMOSPHERE
256 FIGURE 608.1(6) OPEN TUBE INSERTED IN CONTAINER OF WATER
FIGURE 608.1(7) VACUUM APPLIED TO A SEALED TUBE INSERTED IN A CONTAINER OF WATER
FIGURE 608.1(8) EXAMPLE OF SIMPLE SIPHON
257 FIGURE 608.1(9) EXAMPLE OF ASPIRATION OR VENTURE PRINCIPLE
FIGURE 608.1(10) EXAMPLE OF PUMP CAUSING NEGATIVE PRESSURE
258 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
260 FIGURE 608.7(1) YARD HYDRANT WITH STOP AND WASTE VALVE
FIGURE 608.6.1 CONNECTION BETWEEN TWO SYSTEMS
261 FIGURE 608.7(2) PROHIBITED INSTALLATION OF YARD HYDRANTS CONNECTED TO WATER SERVICE LINES
262 TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION
FIGURE 608.8 IDENTIFICATION OF PIPING SYSTEMS
265 FIGURE 608.13.4 BAROMETRIC LOOP
FIGURE 608.13.5 PRESSURE VACUUM BREAKER
266 FIGURE 608.13.7 DOUBLE CHECK-VALVE ASSEM
269 TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS
FIGURE 608.15.1(1) AIR GAP FOR A LAVATORY FAUCET
FIGURE 608.15.1(2) AIR GAP PIPING SYSTEM
270 FIGURE 608.15.1(3) AIR GAPS—LOCATED NEAR SINGLE WALL
FIGURE 608.15.1(4) AIR GAPS—LOCATED NEAR INTERSECTING WALLS
271 FIGURE 608.15.4 SUBMERGED INLET PROTECTED BY VACUUM BREAKER
272 FIGURE 608.15.4.2(1) HOSE (SILL) FAUCET WITHOUT VACUUM BREAKER
FIGURE 608.15.4.2(2) HOSE (SILL) FREEZEPROOF FAUCET WITH INTEGRAL ANTISIPHON DEVICES
273 FIGURE 608.15.4.2(3) HOSE CONNECTION VACUUM BREAKER
274 FIGURE 608.16.1 BEVERAGE DISPENSER
FIGURE 608.16.2 FOR BOILER WITHOUT CONDITIONING CHEMICALS
TABLE 608.16.3(1) GOSSELIN RATINGS
275 TABLE 608.16.3(2) HEAT TRANSFER FLUIDS (ESSENTIALLY NONTOXIC) GOSSE LIN RATING OF 1
FIGURE 608.16.3(3) DOUBLE WALL HEAT EXCHANGER
276 FIGURE 608.16.4(1) COMBINATION WATER DISTRIBUTION/AUTOMATIC SPRINKLER SYSTEM
277 FIGURE 608.16.4(2) COMMON FIRE SPRINKLER AND DOMESTIC WATER SUPPLY
278 FIGURE 608.16.6 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (Photo courtesy of Watts Regulator Company)
279 TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
280 FIGURE 608.17.3 DEPTH OF WELL
FIGURE 608.17.4 WELL CASING
281 FIGURE 608.17.5 CASING FOR DRILLED OR DRIVEN WELL
FIGURE 608.17.7 DUG WELL COVER
SECTION 609 – HEALTH CARE PLUMBING
282 FIGURE 609.2 DUAL WATER SERVICE FOR HOSPITALS
283 SECTION 610 – DISINFECTION OF POTABLE WATER SYSTEM
SECTION 611 – DRINKING WATER TREATMENT UNITS
284 SECTION 612 – SOLAR SYSTEMS
SECTION 613 – TEMPERATURE CONTROL DEVICES AND VALVES
285 BIBLIOGRAPHY
289 CHAPTER 7: SANITARY DRAINAGE
GENERAL COMMENTS
PURPOSE
SECTION 701 – GENERAL
290 FIGURE 701.3(1) COMMON BUILDING SEWER LOCATED WITHIN AN APPROVED PUBLIC SEWER EASEMENT
291 FIGURE 701.3(2) BUILDING ON SAME LOT
SECTION 702 – MATERIALS
292 TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
294 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
295 TABLE 702.4 PIPE FITTINGS
296 SECTION 703 – BUILDING SEWER
297 SECTION 704 – DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
298 FIGURE 704.3 HYDRAULIC JUMP
SECTION 705 – JOINTS
299 FIGURE 705.3 ASBESTOS-CEMENT PIPE JOINT
300 FIGURE 705.4.1 HEAT APPLICATION OF BRAZED JOINT
301 FIGURE 705.5.1 CAULKED JOINT FOR HUB AND SPIGOT (CAST-IRON)
302 FIGURE 705.5.2 CAST-IRON COMPRESSION GASKET
FIGURE 705.5.3 HUBLESS CAST-IRON DRAINAGE PIPE JOINT
303 FIGURE 705.6 CONCRETE MECHANICAL JOINT
304 FIGURE 705.9.3 PREPARATION OF PIPE END
306 FIGURE 705.13.2 LEAD-WIPED JOINT
308 FIGURE 705.18.3 CAST-IRON ADAPTER FITTING
309 FIGURE 705.20(1) SLIP JOINT
FIGURE 705.20(2) SLIP JOINTS
310 TABLE 705.21 CAULKING FERRULE SPECIFICATIONS
TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 – CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
311 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
FIGURE 706.3(1) COMPARISON OF DIFFERENT 11/2-INCH LONG SWEEPS FOR VARIOUS PIPING MATERIA
FIGURE 706.3(2) COMPARISON OF 3-INCH COMBINATION WYE AND EIGHTH BEND FOR VARIOUS PIPING MATERIALS
312 FIGURE 706.3(3) DRAINAGE PATTERN FITTINGS
313 FIGURE 706.3(3)—continued DRAINAGE PATTERN FITTINGS
314 FIGURE 706.3(4) DIFFERENCE BETWEEN PVC PLASTIC 1/4-BEND SHORT SWEEP AND 1/4-BEND VENT
FIGURE 706.3(5) BACK-TO-BACK FIXTURES
FIGURE 706.3(6) HEEL INLET FITTINGS
315 FIGURE 706.3(7) COMBINATION TEES
FIGURE 706.3(8) FITTING USES
316 FIGURE 706.3(9) IMPROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS
FIGURE 706.3(10) PROPER USE OF DWV-PVC/ABS 90 DEGREE FITTINGS
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
317 FIGURE 706.4(1) HEEL- AND SIDE-INLET QUARTER BEND APPLICATION RESTRICTIONS
FIGURE 706.4(2) SIDE-INLET QUARTER BEND FOR WATER CLOSET
318 SECTION 708 – CLEANOUTS
FIGURE 708.1 ACCEPTABLE CLEANOUTS
319 FIGURE 708.2 CLEANOUT INSTALLATIONS
FIGURE 708.3.1 CLEANOUT LOCATIONS
320 FIGURE 708.3.2(1) CLEANOUTS IN BUILDING SEWER—LIMITATIONS
FIGURE 708.3.2(2) MANHOLE LOCATIONS
321 FIGURE 708.3.3 CLEANOUTS
322 FIGURE 708.3.4 CLEANOUTS BASE OF STACK
FIGURE 708.3.6 MANHOLES INSIDE THE BUILDING
323 FIGURE 708.3.5(1) CLEANOUTS AT SEWER JUNCTION
FIGURE 708.3.5(2) TWO-WAY CLEANOUT FITTING
324 FIGURE 708.4 CLEANOUTS ON CONCEALED PIPING
325 TABLE 708.7 CLEANOUT SIZES
FIGURE 708.8 CLEARANCE FOR CLEANOUTS
326 SECTION 709 – FIXTURE UNITS
327 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
328 TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 – DRAINAGE SYSTEM SIZING
329 TABLE 710.1(1) BUILDING DRAINS AND SEWERS
330 FIGURE 710.1(1) BUILDING DRAIN SIZING
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
331 TABLE 710.1(1) HORIZONTAL BRANCH CAPACITY
TABLE 710.1(2) STACK CAPACITIE
FIGURE 710.1(2) HORIZONTAL BRANCH (Complete venting not shown)
332 TABLE 710.1(3) ALLOWABLE STACK DRAINAGE FIXTURE UNITS
FIGURE 710.1(3) STACK SIZING
333 FIGURE 710.1(4) EXAMPLE OF SIZING STACK GREATER THAN THREE BRANCH INTERVALS
FIGURE 710.1(5) SIZING OF STACK THREE BRANCH INTERVALS OR L
334 FIGURE 710.1(6) FLOW IN A STACK
FIGURE 710.1(7) REDUCING SIZE OF DRAINAGE STACK
SECTION 711 – OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
335 FIGURE 711.1 VERTICAL STACK OFFSET
FIGURE 711.2 HORIZONTAL STACK OFFSET
336 FIGURE 711.3 OFFSET SIZING
FIGURE 711.4(1) OFFSET SIZING
FIGURE 711.4(2) OFFSET SIZING
337 SECTION 712 – SUMPS AND EJECTORS
FIGURE 712.1(1) PNEUMATIC SEWAGE EJECTOR
338 FIGURE 712.1(2) VERTICAL SUSPENDED WET PIT SEWAGE PUMP
FIGURE 712.2 SEWAGE EJECTOR INSTALLATION
340 FIGURE 712.4.1(1) MACERATING TOILET SYSTEMS (Photo Courtesy of SFA Saniflo)
341 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
FIGURE 712.4.1(2) MACERATING TOILET SYSTEMS
342 SECTION 713 – HEALTH CARE PLUMBING
343 FIGURE 713.3 COMMON INDIRECT WASTE PIPE FOR STERILIZERS
FIGURE 713.6 CENTRAL VACUUM SYSTEM (Shown for illustrative purposes only)
344 TABLE 713.9.1 MULTIPLE CONNECTION FOR BEDPAN WASHERS TO LOCAL VENT STACK
345 FIGURE 713.9.1 LOCAL VENT STACK
FIGURE 713.9.2 BOTTOM CONNECTION TO LOCAL VENT STACK
FIGURE 713.10 STERILIZER PIPING
346 TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS (Number of Connections of Various Sizes Permitted to Various-sized Sterilizer Vent Stacks)
TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS (Number of Connections of Various Sizes Permitted To Various-sized Vent Stacks)
347 TABLE 713.11.4 PRESSURE INSTRUMENT WASHER STERILIZER SIZES
SECTION 714 – COMPUTERIZED DRAINAGE DESIGN
SECTION 715 – BACKWATER VALVES
348 FIGURE 715.1(1) BACKWATER VALVE
FIGURE 715.1(2) BACKWATER VALVES
349 BIBLIOGRAPHY
351 CHAPTER 8: INDIRECT/SPECIAL WASTE
GENERAL COMMENTS
PURPOSE
SECTION 801 – GENERAL
352 SECTION 802 – INDIRECT WASTES
FIGURE 802.1.1(1) INDIRECTLY CONNECTED THREE-COMPARTMENT FOOD PREPARATION SINK
353 FIGURE 802.1.1(2) REFRIGERATED FOOD CASE DISCHARGING TO HUB DRAIN
FIGURE 802.1.1(3) RESTAURANT KITCHEN INDIRECT WASTE
354 FIGURE 802.1.2 FLOOR DRAIN IN FOOD STORAGE FREEZER
FIGURE 802.1.3 INDIRECT WASTE
355 FIGURE 802.1.5 INDIRECT WASTE—CLEAR-WATER WASTE
356 FIGURE 802.1.6 RESIDENTIAL DISHWASHER WASTE CONNECTIONS
FIGURE 802.1.7 COMMERCIAL DISHWASHER WASTE CONNECTION
357 FIGURE 802.2.1 AIR GAP
FIGURE 802.2 TRAPS FOR INDIRECT WASTE PIPES
358 FIGURE 802.2.2(1) AIR BREAK
FIGURE 802.2.2(2) AIR BREAK
359 FIGURE 802.3(1) WASTE RECEPTORS
FIGURE 802.3(2) WASTE RECEPTORS
360 FIGURE 802.3.1(1) SHALLOW, FLAT BOTTOM WASTE RECEPTOR
FIGURE 802.3.1(2) SIZE AND SHAPE OF WASTE RECEPTOR
FIGURE 802.3.2 CLEAR-WATER WASTE RECEPTOR
SECTION 803 – SPECIAL WASTES
361 FIGURE 802.4 STANDPIPES
SECTION 804 – MATERIALS, JOINTS AND CONNECTIONS
362 BIBLIOGRAPHY
363 CHAPTER 9: VENTS
GENERAL COMMENTS
PURPOSE
SECTION 901 – GENERAL
364 FIGURE 901.2(1) LOSS OF TRAP SEAL
FIGURE 901.2(2) MAXIMUM TRAP SEAL RESISTANCE
365 SECTION 902 – MATERIALS
366 SECTION 903 – OUTDOOR VENT EXTENSION
FIGURE 903.1(1) REDUCTION OF STACK VENT CONNECTION
FIGURE 903.1(2) STACK VENT
367 FIGURE 903.1(3) REQUIRED VENT TO OUTDOORS
369 FIGURE 903.4 VENT CONNECTION AT BASE
FIGURE 903.5 VENT HEADERS
370 SECTION 904 – VENT TERMINALS
FIGURE 904.1 VENT TERMINAL
371 FIGURE 904.5 SEPARATION OF VENT TERMINAL
372 FIGURE 904.6 SIDEWALL VENT
SECTION 905 – VENT CONNECTIONS AND GRADES
373 FIGURE 905.2 GRADE OF VENTS
FIGURE 905.3 VENT CONNECTIONS
374 FIGURE 905.4 VERTICAL RISE OF VENT
375 FIGURE 905.5(1) IMPROPERLY CONNECTED VENT SERVING A DRAIN
FIGURE 905.5(2) PROPERLY CONNECTED VENT SERVING A DRAIN
FIGURE 905.5(3) HORIZONTAL BRANCH VENT ELEVATION
376 SECTION 906 – FIXTURE VENTS
TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
377 FIGURE 906.1(1) DISTANCE FROM TRAP TO VENT
378 FIGURE 906.1(2) MAXIMUM FALL OF FIXTURE DRAIN BETWEEN TRAP AND VENT
FIGURE 906.1(3) TRAP TO VENT DISTANCE FOR WATER CLOSETS
379 FIGURE 906.2(1) VENT CONNECTION
FIGURE 906.2(2) SELF-SIPHONING PHENOMENON
380 FIGURE 906.3(1) CROWN VENTING
FIGURE 906.3(2) CROWN VENTING
SECTION 907 – INDIVIDUAL VENT
381 FIGURE 907.1(1) INDIVIDUAL VENTS
FIGURE 907.1(2) IMPROPERLY INSTALLED INDIVIDUAL VENTS
SECTION 908 – COMMON VENT
382 TABLE 908.3 COMMON VENT SIZES
FIGURE 908.1 COMMON VENTS
FIGURE 908.2 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT SAME LEVEL
383 FIGURE 908.3 COMMON VENTS WITH FIXTURE DRAINS CONNECTING AT DIFFERENT LEVELS
384 SECTION 909 – WET VENTING
FIGURE 909.1(1) HORIZONTAL WET VENTING OF BATHROOM FIXTURES
385 FIGURE 909.1(2) HORIZONTAL WET VENT WITH INDIVIDUAL VENT
FIGURE 909.1(3) HORIZONTAL WET VENT WITH COMMON VENTED FIXTURES UPSTREAM
FIGURE 909.1(4) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY VENTED FIXTURE CONNECTION
FIGURE 909.1(5) PROHIBITED CONNECTION OF TWO FIXTURES UPSTREAM OF DRY VENTED FIXTURE CONNECTION
386 FIGURE 909.1(6) HORIZONTAL WET VENT WITH COMMON VENT WITH AN ADDITIONAL INDIVIDUALLY DRY VENTED FIXTURE
FIGURE 909.1(7) HORIZONTAL WET VENT WITH THREE ADDITIONAL INDEPENDENTLY VENTED FIXTURES
387 FIGURE 909.1(8) HORIZONTAL WET VENT SIZING (PRIVATE BATH GROUP)
FIGURE 909.1(9) HORIZONTAL WET VENT (PUBLIC BATH GROUP)
FIGURE 909.1(10) HORIZONTAL WET VENT
388 FIGURE 909.1(11) HORIZONTAL WET VENT
FIGURE 909.1(12) HORIZONTAL WET VENT
FIGURE 909.1(13) NONCOMPLIANT HORIZONTAL WET VENT
389 FIGURE 909.1(14) NONCOMPLIANT HORIZONTAL WET
FIGURE 909.1(15) NONCOMPLIANT HORIZONTAL WET VENT
390 FIGURE 909.1(16) NONCOMPLIANT HORIZONTAL WET VENT
FIGURE 909.1(17) NONCOMPLIANT HORIZONTAL WET VENT
FIGURE 909.1(18) NONCOMPLIANT HORIZONTAL WET VENT
391 FIGURE 909.1(19) MULTIFLOOR WET VENTING
FIGURE 909.1(20) SINGLE BATHROOM GROUP (PRIVATE) WET VENT
FIGURE 909.1(21) DOUBLE BATHROOM GROUP (PRIVATE) WET VENT
FIGURE 909.1(22) WET VENT VARIATIONS FOR A SINGLE BATHROOM GROUP
392 FIGURE 909.1(23) HORIZONTAL WET VENTING
FIGURE 909.1(24) MULTIPLE INDIVIDUAL VENTS
393 FIGURE 909.1.1(1) VERTICAL WET VENT OF SINGLE BATHROOM GROUP
FIGURE 909.1.1(2) VERTICAL WET VENT OF TWO BATHROOM GROUPS
FIGURE 909.1.1(3) VERTICAL WET VENT OF TWO BATHROOM GROUPS
394 FIGURE 909.1.1(4) VERTICAL WET VENTING
395 TABLE 909.3 WET VENT SIZE
SECTION 910 – WASTE STACK VENT
396 FIGURE 910.2(1) WASTE STACK VENT
FIGURE 910.2(2) WASTE STACK VENT
TABLE 910.4 WASTE STACK VENT SIZE
397 FIGURE 910.3 WASTE STACK VENT OFFSETS AND STACK VENT CONNECTIONS
SECTION 911 – CIRCUIT VENTING
398 FIGURE 911.1(1) CIRCUIT VENTING
399 FIGURE 911.1(2) ROUGH-IN FOR EIGHT CIRCUIT VENTED FIXTURES (Photo courtesy of B&I Contractors)
400 FIGURE 911.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES
FIGURE 911.2 BACK-TO-BACK WATER CLOSETS CIRCUIT VENTED
401 FIGURE 911.3 SIZING A CIRCUIT VENT SYSTEM
FIGURE 911.3.1 SIZING MULTIPLE CIRCUIT-VENTED BRANCHES
402 FIGURE 911.4.1 CIRCUIT VENT WITH RELIEF VENT CONNECTION
SECTION 912 – COMBINATION DRAIN AND VENT SYSTEM
403 FIGURE 911.5(1) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS
FIGURE 911.5(2) CIRCUIT-VENTED BRANCH WITH ADDITIONAL FIXTURE CONNECTIONS
404 FIGURE 912.2(1) COMBINATION DRAIN AND VENT
405 FIGURE 912.2(2) COMBINATION DRAIN AND VENT
FIGURE 912.2(3) COMBINATION DRAIN AND VENT
406 FIGURE 912.2(4) COMBINATION DRAIN AND VENT
407 FIGURE 912.2(5) VERTICAL FIXTURE DRAIN COMPONENT IN COMBINATION DRAIN AND VENT SYSTEM
FIGURE 912.2.2(1) COMBINATION DRAIN AND VENT
408 FIGURE 912.2.2(2) COMBINATION DRAIN AND VENT
FIGURE 912.2.2(3) COMBINATION DRAIN AND VENT
409 FIGURE 912.2.2(4) COMBINATION DRAIN AND VENT
FIGURE 912.2.2(5) COMBINATION DRAIN AND VENT
410 TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE
SECTION 913 ISLAND FIXTURE VENTING
411 FIGURE 913.2 ISLAND FIXTURE VENT
SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
FIGURE 914.1RELIEF VENT CONNECTION
412 SECTION 915 – VENTS FOR STACK OFFSETS
FIGURE 915.2 VENT CONNECTIONS FOR HORIZONTAL OFFSET
413 SECTION 916 – VENT PIPE SIZING
FIGURE 916.1(1) VENT STACK SIZING
414 TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
415 FIGURE 916.1(2) VENT STACK SIZING
FIGURE 916.1(3) STACK VENT SIZIN
416 FIGURE 916.2(1) VENT SIZING
FIGURE 916.2(2) VENT SIZING
417 FIGURE 916.2(3) VENT SIZING
FIGURE 916.2(4) VENT SIZING
418 FIGURE 916.3(1) DEVELOPED LENGTH OF VENTS
419 FIGURE 916.3(2) DEVELOPED LENGTH OF VENTS
FIGURE 916.4 COMMON BRANCH VENT
420 FIGURE 916.5.1 SUMP VENT
SECTION 917 – AIR ADMITTANCE VALVE
421 TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS
422 FIGURE 917.3(1) AIR ADMITTANCE—INDIVIDUAL VENT
FIGURE 917.3(2) COMMON VENT
FIGURE 917.3(3) WET VENT
FIGURE 917.3(4) CIRCUIT VENT
423 FIGURE 917.3(5) BRANCH VENT
FIGURE 917.3(6) VENT CONNECTION NOT PERMITTED
424 FIGURE 917.3.1(1) PRESSURE IN DRAINAGE STACK
FIGURE 917.3.1(2) LOCATION OF HORIZONTAL BRANCH DRAIN
FIGURE 917.4 DISTANCE ABOVE DRAIN
425 FIGURE 917.7 VENT TO THE OPEN AIR REQUIRED
SECTION 918 – ENGINEERED VENT SYSTEMS
426 FIGURE 917.8(1) PROHIBITED USE OF AIR ADMITTANCE VALVE
FIGURE 917.8(2) ONE MANUFACTURER’S ENGINEERED DESIGN FOR USE OF AN AIR ADMITTANCE VALVE ON A SUMP
427 EQUATION 9-1
FIGURE 918.2(1) INDIVIDUAL VENT DEVELOPED LENGTH
TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
428 FIGURE 918.2(1) EXAMPLE OF ENGINEERED REDUCED-SIZE VENT
TABLE 918.2(2) MAXIMUM LOADS ON MULTIPLE-STORY DRAINAGE STACKS
429 SECTION 919 – COMPUTERIZED VENT DESIGN
BIBLIOGRAPHY
431 CHAPTER 10: TRAPS, INTERCEPTORS AND SEPARATORS
GENERAL COMMENTS
PURPOSE
SECTION 1001 – GENERAL
SECTION 1002 – TRAP REQUIREMENTS
432 FIGURE 1002.1(1) TRAP REQUIREMENTS
FIGURE 1002.1(2) TRAP REQUIREMENTS
433 FIGURE 1002.2 SLIP JOINTS IN TRAPS
434 FIGURE 1002.3 PROHIBITED TRAPS
435 FIGURE 1002.4(1) TRAP PRIMER FOR TWO FLOOR DRAINS
FIGURE 1002.4(2) TRAP SEAL PROTECTION METHODS FOR TRAPS SUBJECT TO EVAPORATION
436 FIGURE 1002.6 BUILDING TRAP
FIGURE 1002.7 INSTALLATION OF TRAP
437 SECTION 1003 – INTERCEPTORS AND SEPARATORS
438 FIGURE 1003.2 INTERCEPTORS AND SEPARATORS
440 FIGURE 1003.3(1) TYPICAL GRAVITY-TYPE GREASE INTERCEPTOR
FIGURE 1003.3(2) TYPICAL HYDROMECHANICAL GREASE INTERCEPTOR
441 FIGURE 1003.3.2 FOOD WASTE GRINDER CONNECTING TO GREASE INTERCEPTOR
445 TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa
446 FIGURE 1003.3.4.2 FLOW CONTROL DEVICE
449 FIGURE 1003.9(1) TYPICAL SINGLE-FIXTURE INSTALLATIONS
FIGURE 1003.9(2) VENTING OF GREASE INTERCEPTOR
450 FIGURE 1003.9(3) VENTING OF INTERCEPTORS AND SEPARATORS
SECTION 1004 – MATERIALS, JOINTS AND CONNECTIONS
451 FIGURE 1003.10(1) AUTOMATIC GREASE INTERCEPTOR
FIGURE 1003.10(2) SENSOR-CONTROLLED GREASE RECOVERY DEVICE
BIBLIOGRAPHY
453 CHAPTER 11: STORM DRAINAGE
GENERAL COMMENTS
PURPOSE
SECTION 1101 – GENERAL
455 TABLE 1101.7 FLOW RATE, IN GALLONS PER MINUTE, OF VARIOUS ROOF DRAINS AT VARIOUS WATER DEPTHS AT DRAIN INLETS (INCHES
FIGURE 1101.7 ROOF DRAIN WITH OVERFLOW
456 SECTION 1102 – MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
458 TABLE 1102.5 SUBSOIL DRAIN PIPE
TABLE 1102.7 PIPE FITTINGS
459 SECTION 1103 – TRAPS
FIGURE 1103 TRAPS ON STORM DRAINS THAT CONNECT TO COMBINATION SANITARY AND STORM SEWER SYSTEMS
SECTION 1104 – CONDUCTORS AND CONNECTIONS
460 SECTION 1105 – ROOF DRAINS
SECTION 1106 – SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
461 FIGURE 1106.1100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
462 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
463 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
464 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
465 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
466 TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS
467 TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS
468 TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINGE PIPING
469 FIGURE 1106.3 HORIZONTAL DRAIN AND SEWERS
FIGURE 1106.4 VERTICAL WALLS
470 TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS
SECTION 1107 – SECONDARY (EMERGENCY) ROOF DRAINS
471 FIGURE 1107.1 SECONDARY ROOF DRAINAGE NOT REQUIRED
472 FIGURE 1107.2(1) SEPARATE PRIMARY AND SECONDARY ROOF DRAINS
FIGURE 1107.2(2) PROHIBITED SECONDARY ROOF DRAIN CONNECTION
473 FIGURE 1107.3 SIZE OF SCUPPERS
SECTION 1108 – COMBINED SANITARY AND STORM SYSTEM
474 FIGURE 1108.1 COMBINED SANITARY AND STORM SEWER
TABLE 1108.1 EQUIVALENT ROOF AREA CONVERSIONS
SECTION 1109 – VALUES FOR CONTINUOUS FLOW
SECTION 1110 – CONTROLLED FLOW ROOF DRAIN SYSTEMS
475 SECTION 1111 – SUBSOIL DRAINS
476 FIGURE 1110.4 MINIMUM NUMBER OF ROOF DRAINS FOR CONTROLLED FLOW
SECTION 1112 – BUILDING SUBDRAINS
477 FIGURE 1111.1(1) SUBSOIL DRAIN SUBJECT TO BACKFLOW
FIGURE 1111.1(2) SUBSOIL DRAINAGE
478 SECTION 1113 – SUMPS AND PUMPING SYSTEMS
BIBLIOGRAPHY
481 CHAPTER 12: SPECIAL PIPING AND STORAGE SYSTEMS
GENERAL COMMENTS
PURPOSE
SECTION 1201 – GENERAL
SECTION 1202 – MEDICAL GASES
482 SECTION 1203 – OXYGEN SYSTEMS
483 BIBLIOGRAPHY
485 CHAPTER 13: REFERENCED STANDARDS
GENERAL COMMENTS
PURPOSE
486 ASME REFERENCE DOCUMENT
487 ANSI
AHRI
ASME
488 ASSE
489 ASTM
492 AWS
AWWA
493 CISPI
CSA
494 ICC
ISEA
NFPA
NSF
495 PDI
UL
497 APPENDIX A: PLUMBING PERMIT FEE SCHEDULE
GENERAL COMMENTS
PURPOSE
PERMIT ISSUANCE
UNIT FEE SCHEDULE
498 OTHER INSPECTIONS AND FEES
499 APPENDIX B: RATES OF RAINFALL FOR VARIOUS CITIES
GENERAL COMMENTS
PURPOSE
501 APPENDIX C: GRAY WATER RECYCLING SYSTEMS
GENERAL COMMENTS
PURPOSE
SECTION C101 – GENERAL
502 FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION
503 FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS
505 SECTION C102 – SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS
506 SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
507 TABLE C103.6 GRAY WATER DISCHARGE VOLUMES
509 TABLE C103.8 LOCATION OF GRAY WATER SYSTEM
TABLE C 103.9.1 DESIGN LOADING RATE
510 TABLE C103.10 DISTRIBUTION PIPE
511 APPENDIX D: DEGREE DAY AND DESIGN TEMPERATURES
GENERAL COMMENTS
PURPOSE
512 TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
513 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
514 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
515 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
516 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
517 BIBLIOGRAPHY
519 APPENDIX E: SIZING OF WATER PIPING SYSTEM
GENERAL COMMENTS
PURPOSE
SECTION E101 – GENERAL
SECTION E102 – INFORMATION REQUIRED
520 SECTION E103 – SELECTION OF PIPE SIZE
525 TABLE E.1
TABLE E.2
526 FIGURE E103.3(1) EXAMPLE-SIZING
527 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
528 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTU
529 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
530 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
531 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
532 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
533 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
534 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING)
535 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
536 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
537 FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa
538 SECTION E201 – SELECTION OF PIPE SIZE
SECTION E202 – DETERMINATION OF PIPE VOLUMES
539 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
540 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
541 TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
543 APPENDIX F: STRUCTURAL SAFETY
GENERAL COMMENTS
PURPOSE
SECTION F101 – CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
544 FIGURE 101.1 CUTTING, NOTCHING AND BORING JOISTS
FIGURE 101.2 CUTTING, NOTCHING AND BORED HOLES
545 APPENDIX G: VACUUM DRAINAGE SYSTEM
GENERAL COMMENTS
PURPOSE
SECTION G101 – VACUUM DRAINAGE SYSTEM
546 FIGURE G101.2.1(1) VACUUM SYSTEMS
FIGURE G101.2.1(2) VACUUM SYSTEMS
FIGURE G101.2.2 TYPICAL WATER CLOS
549 INDEX
557 ICC MEMBERSHIP BENEFITS
558 ICC ELECTRONIC CODES
559 BUILDING SAFETY
560 HELPFUL LINKS
IPC Commentary 09 2009
$61.21