IPFC 12:2012 Edition
$31.82
International Performance Code for Buildings and Facilities
Published By | Publication Date | Number of Pages |
ICC | 2012 | 211 |
Presents regulations based on outcome rather than prescription. It encourages new design methods by allowing a broader parameter for meeting the intent of the International Codes®. An updated User’s Guide is included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2012 INTERNATIONAL CODE COUNCIL PERFORMANCE CODE® FOR BUILDINGS AND FACILITIES |
2 | 2012 INTERNATIONAL CODE COUNCIL PERFORMANCE CODE® FOR BUILDINGS AND FACILITIES ICCPC® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE |
8 | EFFECTIVE USE OF THE ICC PERFORMANCE CODE FOR BUILDINGS AND FACILITIES |
10 | GUIDE TO THE USE OF THE ICC PERFORMANCE CODE FOR BUILDINGS AND FACILITIES |
14 | LEGISLATION |
16 | TABLE OF CONTENTS |
18 | PART I—ADMINISTRATIVE CHAPTER 1 GENERAL ADMINISTRATIVE PROVISIONS SECTION 101 INTENT AND PURPOSE SECTION 102 SCOPE SECTION 103 ADMINISTRATIVE PROVISIONS |
23 | SECTION 104 ACCEPTABLE METHODS |
26 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINED TERMS |
28 | CHAPTER 3 DESIGN PERFORMANCE LEVELS SECTION 301 MINIMUM PERFORMANCE SECTION 302 USE AND OCCUPANCY CLASSIFICATION SECTION 303 PERFORMANCE GROUPS |
29 | TABLE 303.1 PERFORMANCE GROUP CLASSIFICATIONS FOR BUILDINGS AND FACILITIES |
30 | TABLE 303.3 MAXIMUM LEVEL OF DAMAGE TO BE TOLERATED BASED ON PERFORMANCE GROUPS AND DESIGN EVENT MAGNITUDES SECTION 304 MAXIMUM LEVEL OF DAMAGE TO BE TOLERATED |
31 | SECTION 305 MAGNITUDES OF EVENT |
34 | CHAPTER 4 RELIABILITY AND DURABILITY SECTION 401 RELIABILITY SECTION 402 DURABILITY |
36 | PART II—BUILDING CHAPTER 5 STABILITY SECTION 501 STRUCTURAL FORCES |
37 | TABLE 501.3.4 RAIN LOADS |
38 | CHAPTER 6 FIRE SAFETY SECTION 601 SOURCES OF FIRE IGNITION SECTION 602 LIMITING FIRE IMPACT |
40 | CHAPTER 7 PEDESTRIAN CIRCULATION SECTION 701 MEANS OF EGRESS SECTION 702 ACCESSIBILITY SECTION 703 TRANSPORTATION EQUIPMENT |
42 | CHAPTER 8 SAFETY OF USERS SECTION 801 HAZARDOUS MATERIALS SECTION 802 HAZARDS FROM BUILDING MATERIALS SECTION 803 PREVENTION OF FALLS SECTION 804 CONSTRUCTION AND DEMOLITION HAZARDS |
43 | SECTION 805 SIGNS SECTION 806 EMERGENCY NOTIFICATION |
44 | CHAPTER 9 MOISTURE SECTION 901 SURFACE WATER SECTION 902 EXTERNAL MOISTURE SECTION 903 INTERNAL MOISTURE |
46 | CHAPTER 10 INTERIOR ENVIRONMENT SECTION 1001 CLIMATE AND BUILDING FUNCTIONALITY SECTION 1002 INDOOR AIR QUALITY SECTION 1003 AIR-BORNE AND IMPACT SOUND SECTION 1004 ARTIFICIAL AND NATURAL LIGHT |
48 | CHAPTER 11 MECHANICAL SECTION 1101 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT (HVAC) SECTION 1102 REFRIGERATION SECTION 1103 PIPED SERVICES |
50 | CHAPTER 12 PLUMBING SECTION 1201 PERSONAL HYGIENE SECTION 1202 LAUNDERING SECTION 1203 DOMESTIC WATER SUPPLIES SECTION 1204 WASTEWATER |
52 | CHAPTER 13 FUEL GAS SECTION 1301 FUEL GAS PIPING AND VENTS |
54 | CHAPTER 14 ELECTRICITY SECTION 1401 ELECTRICITY |
56 | CHAPTER 15 ENERGY EFFICIENCY SECTION 1501 ENERGY EFFICIENCY |
58 | PART III—FIRE CHAPTER 16 FIRE PREVENTION SECTION 1601 FIRE PREVENTION |
60 | CHAPTER 17 FIRE IMPACT MANAGEMENT SECTION 1701 FIRE IMPACT MANAGEMENT |
62 | CHAPTER 18 MANAGEMENT OF PEOPLE SECTION 1801 MANAGEMENT OF PEOPLE |
64 | CHAPTER 19 MEANS OF EGRESS SECTION 1901 MEANS OF EGRESS |
66 | CHAPTER 20 EMERGENCY NOTIFICATION, ACCESS AND FACILITIES SECTION 2001 EMERGENCY NOTIFICATION, ACCESS AND FACILITIES |
68 | CHAPTER 21 EMERGENCY RESPONDER SAFETY SECTION 2101 EMERGENCY RESPONDER SAFETY |
70 | CHAPTER 22 HAZARDOUS MATERIALS SECTION 2201 HAZARDOUS MATERIALS |
72 | PART IV—APPENDICES APPENDIX A RISK FACTORS OF USE AND OCCUPANCY CLASSIFICATIONS SECTION A101 OBJECTIVE SECTION A102 FUNCTIONAL STATEMENTS SECTION A103 USE AND OCCUPANCY CLASSIFICATION |
80 | APPENDIX B WORKSHEET FOR ASSIGNING SPECIFIC STRUCTURES TO PERFORMANCE GROUPS SECTION B101 RISK FACTOR TABLE B101.1 WORKSHEET FOR ASSIGNING SPECIFIC STRUCTURES TO PERFORMANCE GROUPS |
82 | APPENDIX C INDIVIDUALLY SUBSTANTIATED DESIGN METHOD SECTION C101 GENERAL |
84 | APPENDIX D QUALIFICATION CHARACTERISTICS FOR DESIGN AND REVIEW OF PERFORMANCE-BASED DESIGNS SECTION D101 GENERAL |
86 | APPENDIX E USE OF COMPUTER MODELS SECTION E101 GENERAL SECTION E102 REQUIREMENTS SECTION E103 RESPONSIBILITY |
88 | INDEX |
92 | 2012 ICC PERFORMANCE CODE® FOR BUILDINGS AND FACILITIES USER’S GUIDE |
94 | USER’S GUIDE TABLE OF CONTENTS |
98 | FOREWORD |
104 | PART I—ADMINISTRATIVE CHAPTER 1 GENERAL ADMINISTRATIVE PROVISIONS SECTION 101 INTENT AND PURPOSE SECTION 102 SCOPE SECTION 103 ADMINISTRATIVE PROVISIONS |
118 | SECTION 104 ACCEPTABLE METHODS |
122 | CHAPTER 2 DEFINITIONS SECTION 202 DEFINED TERMS |
124 | CHAPTER 3 DESIGN PERFORMANCE LEVELS SECTION 301 MINIMUM PERFORMANCE SECTION 302 USE AND OCCUPANCY CLASSIFICATION |
125 | SECTION 303 PERFORMANCE GROUPS |
128 | SECTION 304 MAXIMUM LEVEL OF DAMAGE TO BE TOLERATED SECTION 305 MAGNITUDES OF EVENT |
132 | CHAPTER 4 RELIABILITY AND DURABILITY SECTION 401 RELIABILITY |
133 | SECTION 402 DURABILITY |
136 | PART II—BUILDING CHAPTER 5 STABILITY SECTION 501 STRUCTURAL FORCES |
142 | CHAPTER 6 FIRE SAFETY SECTION 601 SOURCES OF FIRE IGNITION |
143 | SECTION 602 LIMITING FIRE IMPACT |
146 | CHAPTER 7 PEDESTRIAN CIRCULATION SECTION 701 MEANS OF EGRESS |
147 | SECTION 702 ACCESSIBILITY |
148 | SECTION 703 TRANSPORTATION EQUIPMENT |
150 | CHAPTER 8 SAFETY OF USERS SECTION 801 HAZARDOUS MATERIALS |
151 | SECTION 802 HAZARDS FROM BUILDING MATERIALS SECTION 803 PREVENTION OF FALLS |
152 | SECTION 804 CONSTRUCTION AND DEMOLITION HAZARDS SECTION 805 SIGNS |
153 | SECTION 806 EMERGENCY NOTIFICATION |
154 | CHAPTER 9 MOISTURE SECTION 901 SURFACE WATER SECTION 902 EXTERNAL MOISTURE |
155 | SECTION 903 INTERNAL MOISTURE |
158 | CHAPTER 10 INTERIOR ENVIRONMENT |
160 | CHAPTER 11 MECHANICAL |
162 | CHAPTER 12 PLUMBING |
164 | CHAPTER 13 FUEL GAS SECTION 1301 FUEL GAS PIPING AND VENTS |
166 | CHAPTER 14 ELECTRICITY SECTION 1401 ELECTRICITY |
168 | CHAPTER 15 ENERGY EFFICIENCY SECTION 1501 ENERGY EFFICIENCY |
170 | PART III—FIRE CHAPTER 16 FIRE PREVENTION |
172 | CHAPTER 17 FIRE IMPACT MANAGEMENT |
174 | CHAPTER 18 MANAGEMENT OF PEOPLE |
176 | CHAPTER 19 MEANS OF EGRESS |
178 | CHAPTER 20 EMERGENCY NOTIFICATION, ACCESS AND FACILITIES |
182 | CHAPTER 21 EMERGENCY RESPONDER SAFETY |
184 | CHAPTER 22 HAZARDOUS MATERIALS SECTION 2201 HAZARDOUS MATERIALS |
192 | PART IV—APPENDICES APPENDIX A RISK FACTORS OF USE AND OCCUPANCY CLASSIFICATIONS A101 OBJECTIVE A102 FUNCTIONAL STATEMENTS A103 USE AND OCCUPANCY CLASSIFICATIONS |
198 | APPENDIX B WORKSHEET FOR ASSIGNING SPECIFIC STRUCTURES TO PERFORMANCE GROUPS |
199 | WORKSHEET FOR ASSIGNING SPECIFIC STRUCTURES TO PERFORMANCE GROUPS |
200 | APPENDIX C INDIVIDUALLY SUBSTANTIATED DESIGN METHOD |
202 | APPENDIX D QUALIFICATION CHARACTERISTICS FOR DESIGN AND REVIEW OF PERFORMANCE-BASED DESIGNS |
204 | APPENDIX E USE OF COMPUTER MODELS |
206 | REFERENCES |
208 | ICC MEMBERSHIP INFORMATION |
209 | ICC-ES ICC EVALUATION SERVICE |
210 | MAINTAIN YOUR SUSTAINABLE BUILDING EXPERTISE WITH GREEN/ENERGY TRAINING |
211 | COMMITTED TO BUILDING A GREEN AND SUSTAINABLE WORLD |