Shopping Cart

No products in the cart.

ID EnergyCode 2020 1stprint

$25.05

Idaho Energy Conservation Code

Published By Publication Date Number of Pages
ID 2020
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
1 2020 IDAHO ENERGY CONSERVATION CODE
2 2020 IDAHO ENERGY CONSERVATION CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
12 TABLE OF CONTENTS
14 IECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
16 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
SECTION C102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
18 SECTION C104 FEES
SECTION C105 INSPECTIONS
19 SECTION C106 VALIDITY
SECTION C107 REFERENCED STANDARDS
SECTION C108 STOP WORK ORDER
SECTION C109 BOARD OF APPEALS
20 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
26 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
27 FIGURE C301.1 CLIMATE ZONES
28 TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
29 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
30 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
31 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
32 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
33 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
34 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
35 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
36 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
37 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
38 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
39 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
40 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
41 TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
42 TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
44 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
45 EQUATION 4-1
EQUATION 4-2
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
46 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
47 TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
49 EQUATION 4-3
50 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONS
TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
51 EQUATION 4-5
53 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
54 SECTION C403 BUILDING MECHANICAL SYSTEMS
55 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
56 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
57 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
58 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
59 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
60 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
61 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
62 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
63 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
64 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
65 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
67 TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS
68 TABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
69 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
72 TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
73 TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
74 TABLE C403.8.1(1) FAN POWER LIMITATION
75 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
76 TABLE C403.8.5.1 COOLING SYSTEMS
78 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
79 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
80 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
82 EQUATION 4-8
83 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)
SECTION C404 SERVICE WATER HEATING (MANDATORY)
84 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
85 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
86 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
87 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
89 EQUATION 4-9
90 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
91 FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
92 EQUATION 4-10
93 EQUATION 4-11
94 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
95 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
96 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
97 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
98 TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
99 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZ
100 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZ
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
101 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
102 SECTION C407 TOTAL BUILDING PERFORMANCE
104 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
105 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
106 TABLE C407.5.1(2) HVAC SYSTEMS MAP
107 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
108 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
109 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
112 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
114 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
115 SECTION C503 ALTERATIONS
116 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
118 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
119 AMCA
ANSI
APSP
ASHRAE
120 ASME
ASTM
121 CRRC
CSA
CTI
DASMA
DOE
122 ICC
IEEE
IES
ISO
123 NEMA
NFPA
NFRC
SMACNA
UL
US-FTC
124 WDMA
126 APPENDIX CA SOLAR-READY ZONE—COMMERCIAL
SECTION CA101 SCOPE
SECTION CA102 GENERAL DEFINITION
SECTION CA103 SOLAR-READY ZONE
128 INDEX
138 IECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
140 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
SECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS
141 SECTION R104 FEES
SECTION R105 INSPECTIONS
142 SECTION R106 VALIDITY
SECTION R107 REFERENCED STANDARDS
SECTION R108 STOP WORK ORDER
143 SECTION R109 BOARD OF APPEALS
144 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
148 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
149 FIGURE R301.1 CLIMATE ZONES
150 TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
151 TABLE R01.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
152 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
153 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
154 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
155 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
156 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
157 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
158 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
159 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
160 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
161 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
162 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
163 TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
164 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
166 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
167 SECTION R402 BUILDING THERMAL ENVELOPE
168 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT
TABLE R402.1.4 EQUIVALENT U-FACTORSa
169 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
171 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
172 SECTION R403 SYSTEMS
173 TABLE R402.6 LOG HOME PRESCRIPTIVE THERMAL ENVELOPE REQUIREMENTS BY COMPONENT
175 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYa
176 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
177 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
178 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
179 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
180 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
181 TABLE R406.4 MAXIMUM ENERGY RATING INDEX
182 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
183 SECTION R503 ALTERATIONS
SECTION R504 REPAIRS
184 SECTION R505 CHANGE OF OCCUPANCY OR USE
186 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
APSP
ASHRAE
ASTM
187 CSA
DASMA
HVI
ICC
188 IEEE
NFPA
NFRC
RESNET
189 UL
US-FTC
WDMA
190 APPENDIX RA SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION RA101 SCOPE
SECTION RA102 GENERAL DEFINITION
SECTION RA103 SOLAR-READY ZONE
192 INDEX
ID EnergyCode 2020 1stprint
$25.05