IEEE 1310-2012(Redline)

$60.67

IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines (Redline)

Published By Publication Date Number of Pages
IEEE 2012 30
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Inactive-Reserved. This procedure is intended for form-wound bars/coils for rotating machines rated 10 kV or more at 50 Hz or 60 Hz that are subjected to many transitions from no-load to full-load current during normal operations, and where rapid load variations are typical. Only the thermal cyclic degradation within the groundwall insulation and/or the conductor package and delamination of the groundwall insulation from the conductor are addressed by this test. The procedure is applicable to indirectly-cooled machine types such as: — combustion turbine generators — pumped storage or peaking duty hydrogenerators — synchronous condensers — cyclic duty water pump motors Various pass/fail criteria are presented, and the ones that apply in a specific circumstance must be agreed between user and manufacturer prior to commencement of testing

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 1310-2012 Front Cover
3 Title page
6 Notice to users

Laws and regulations

Copyrights

Updating of IEEE documents

Errata

Patents
8 Participants
10 Introduction
11 Contents
12 Important notice

1. Overview
13 1.1 Scope
14 1.2 Purpose
2. Normative references
16 3. Definitions
4. Thermal cycling test description
4.1 Test objects
4.2 Method of heating
17 4.3 Method of cooling
4.4 Temperature cycle and schedule
18 5. Thermal cycling test setup
5.1 Quantity of bars/coils required for testing
19 5.2 Positioning and setting up bars/coils for test
21 5.3 Temperature criteria, measurement, and control
22 6. Bar/coil preparation
7. Diagnostic tests preceding and during thermal cycling
23 7.1 Electrical proof test for the groundwall insulation
7.2 Dissipation factor and tip-up measurements
7.3 Partial discharge measurements
7.4 Physical measurements
7.5 Tap test—mechanical delamination detection
24 7.6 Surface resistivity
8. Post-thermal cycle tests
8.1 Proof tests
25 8.2 Breakdown or voltage endurance test
8.3 Dissection
26 9. Preparation of test report
27 Annex A (normative) Sample calculation for estimating current rating of test supply
A.1 Approximate method for calculation
28 A.2 Loss of thermal energy, practical tests
A.3 Test equipment
29 Annex B (informative) Decisions required by manufacturer/purchaser/testing facility
30 Annex C (informative) Bibliography