IEEE 1601 2010
$37.38
IEEE Trial-Use Standard for Optical AC Current and Voltage Sensing Systems
Published By | Publication Date | Number of Pages |
IEEE | 2010 | 41 |
New IEEE Standard – Active. The performance of optical current and voltage measurement systems used in the generation, transmission, and distribution of alternating current electricity, and to assist in the proper selection of such equipment is described in this trial-use standard. This standard covers certain physical characteristics of the sensing systems that use optical techniques to measure current and voltage. This standard provides the requirements for the performance characteristics and the test of optical current and voltage sensors of a nominal system voltage of 1 kV and above, the information related to the nature of these sensors, and the information related to the application and use of these sensors.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1601ā¢-2010, Front cover |
3 | Title page |
6 | Introduction Notice to users Laws and regulations Copyrights Updating of IEEE documents |
7 | Errata Interpretations Patents |
8 | Participants |
10 | Contents |
13 | IMPORTANT NOTICE 1. Overview 1.1 Scope 1.2 Purpose 2. Normative references |
14 | 3. Definitions |
16 | 4. General requirements 4.1 Insulation requirements 4.1.1 Voltage ratings, dielectric test levels, and prescribed extinction voltages 4.1.2 Capacitance and dissipation factor requirements 4.1.3 Creepage distance requirements 4.1.4 External radio influence voltage (RIV) requirements 4.1.5 Routine partial discharge test |
17 | 4.1.6 Insulation resistance requirements 4.1.7 Power frequency voltage withstand test 4.2 Mineral oil requirements 4.3 Requirements for accuracy and accuracy verification systems 4.3.1 Dynamic range and designation of accuracy |
19 | 4.3.2 Output Interface |
20 | 4.3.3 Burdens 4.3.4 Bandwidth and Accuracy on Harmonics 4.4 Mechanical performance requirements 4.4.1 Sealing tests |
21 | 4.4.2 Mechanical strength of the transformer 4.5 Thermal performance requirements 4.6 Electromagnetic compliance for sensor electronics 4.7 Dissolved gas and water content requirements for new oil-immersed transformers 4.8 Performance of internal arc protection 4.9 Seismic performance requirements |
22 | 5. Test conditions 6. Classification of tests 6.1 Routine tests and test sequences 6.1.1 Routine tests applicable to optical instrument transformers 6.1.2 Routine tests applicable to optical current transformers 6.1.3 Routine tests applicable to optical voltage transformers |
23 | 6.1.4 Sequence of the routine tests |
24 | 6.2 Type tests and test sequence 6.2.1 Type tests applicable to optical instrument transformers 6.2.2 Sequence of the type tests |
26 | 6.2.3 Maximum number of samples used for the type tests |
27 | 6.3 Special tests 7. Routine test procedures (applicable to optical instrument transformers) 7.1 Verification of terminal markings and polarity 7.2 Capacitance and dissipation factor test 7.3 Power frequency voltage withstand test 7.4 Partial discharge test |
28 | 7.5 Sealing test 7.5.1 Sealing test for gas-filled transformers 8. Routine test procedures applicable to optical current transformers 8.1 Accuracy test for metering rated current transformers |
29 | 8.2 Performance characteristics of relaying rated optical current transformers 9. Routine test procedures applicable to optical voltage transformers 9.1 Accuracy test 9.2 Resistance measurement of optical transformers |
30 | 10. Type test procedures 10.1 Mechanical test 10.1.1 Transformers for pedestal mounting 10.1.2 Transformers for suspension mounting 10.2 Lightning impulse voltage test on the optical transformer 10.3 Switching impulse voltage test on the optical transformer ā wet |
31 | 10.4 External Radio influence voltage (RIV) test 10.5 Power frequency voltage withstand test ā wet 10.6 Power frequency voltage withstand / partial discharge test ā dry |
32 | 10.7 Temperature rise test 10.7.1 Temperature rise test for optical current transformers at the continuous thermal current rating 10.7.2 Temperature rise test for optical voltage transformers 10.8 Short-time mechanical rating test |
33 | 10.8.1 Short-time mechanical test for optical current transformers 10.8.2 Criteria for the short-time mechanical rating test 10.9 Accuracy performance test 10.10 Creepage distance measurement 10.11 Sealing system test for gas-filled instrument transformers |
34 | 10.12 EMC Tests 11. Special test procedures 11.1 Internal arc test 11.2 Seismic qualification |
35 | Annex A (normative) Test code |
36 | Annex B (informative) Insulation requirements |
40 | Annex C (informative) Rated voltage factor |
41 | Annex D (informative) Bibliography |