New IEEE Standard – Active. Guidelines for establishing criteria for application, performance, interchangeability, tests, life cycle costs, and safety requirements of traction power rectifier transformers are established in this standard. Set forth are the electrical, mechanical and theremal design, manufacturing, and testing requirements for traction power rectifier transformers for dc electrification systems. Covered in this standard are liquid-immersed and dry-type transformers, including those with cast coil and epoxy resin encapsulated windings.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 1653.1™-2016 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Participants
9 Introduction
10 Contents
11 1. Overview
1.1 Scope
1.2 Purpose
1.3 Mandatory requirements
2. Normative references
12 3. Definitions, acronyms, and abbreviations
3.1 Definitions
14 3.2 Acronyms and abbreviations
4. Service conditions
4.1 Usual service conditions
15 4.2 Unusual service conditions
5. Rating data
5.1 Continuous rating
16 5.2 Duty cycles
5.3 Winding temperature limits
17 5.4 Nameplates
6. Design
6.1 Taps
6.2 Impedance
6.3 Winding connections
18 6.4 Secondary winding voltage, current, and impedance differences
19 6.5 Design optimization
6.6 Life expectancy and reliability
20 7. Protection
7.1 Overtemperature protection
7.2 Voltage surge protection
7.3 Accessories
21 7.4 Grounding
8. Testing
8.1 General
8.2 Routine tests
8.3 Design tests
22 8.4 Other tests
23 8.5 Factory testing and calculation
29 8.6 Factory test sequence
8.7 Factory test report
8.8 Field inspection and field tests
33 Annex A (informative) Design considerations for transformer specification development
A.1 Application guidelines
34 A.2 System overvoltages and transformer failures
35 A.3 Other application criteria
37 Annex B (informative) Ping test
B.1 Purpose
38 B.2 Mitigation of breaker transients
41 Annex C (informative) Correlation between per-unit commutating reactance of rectifier transformer and inherent voltage regulation of transformer-rectifier assembly
C.1 Introduction
C.2 Symbols
C.3 Reactive voltage drop calculation
C.4 Resistive voltage drop calculation
42 C.5 Open circuit voltage and rated voltage of rectifier unit
C.6 Inherent voltage regulation calculation
C.7 Correlation between rectifier transformer and transformer and rectifier assembly
C.8 Example
43 C.9 Conclusion
44 Annex D (informative) Bibliography
45 Back cover