IEEE 1653.2-2020
$48.21
IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications up to 1500 V DC Nominal Output
Published By | Publication Date | Number of Pages |
IEEE | 2020 | 60 |
Revision Standard – Active. The design, manufacturing, and testing unique to the application of uncontrolled semiconductor power rectifiers for direct current (dc) supplied transportation substation applications up to 1500 V dc nominal output is covered in this standard. The standard is intended to address traction power substation rectifiers that are to be provided as part of a rectifier transformer unit or that are to be provided separately. Application information and extensive definitions of related technical terms are included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1653.2ā¢-2020 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
8 | Introduction |
9 | Contents |
11 | 1.āOverview 1.1āScope 1.2āPurpose 2.āNormative references |
12 | 3.āDefinitions 3.1āBasic rectifier components and equipment |
13 | 3.2āAppurtenances and auxiliaries |
14 | 3.3āSemiconductor rectifier diode characteristics |
15 | 3.4āRectifier circuit properties and terminology |
17 | 3.5āRectifier characteristics |
19 | 3.6āRectifier unit ratings |
20 | 4.āSymbols and abbreviations 4.1āRectifier symbols |
22 | 4.2āRectifier protective device numbers 5.āRectifier circuits 5.1āGeneral |
24 | 6.āService conditions 6.1āUsual service conditions 6.2āUnusual service conditions |
25 | 7.āRatings 7.1āRating of rectifier units 7.2āBasis of rating 7.3āStandard service ratings |
28 | 7.4āOperation above rated voltage 8.āPerformance characteristics 8.1āEfficiency and losses |
29 | 8.2āVoltage regulation |
33 | 8.3āPower factor |
35 | 8.4āTolerances and unbalance criteria |
36 | 8.5āAuxiliaries 9.āNameplates 10.āInterphase transformers 10.1āGeneral |
37 | 10.2āSpecification information 10.3āSubmittal information |
38 | 11.āTest procedures 11.1āRectifier transformer tests 11.2āInterphase transformer tests 11.3āRectifier tests |
41 | 11.4āRectifier unit tests |
51 | AnnexĀ A (informative) Recommended practice and design guide A.1āHarmonics from uncontrolled rectifiers A.2āRectifier service ratings |
52 | A.3āRectifier current unbalance A.4āRectifier transformer unit circuit configurations |
53 | A.5āRectifier protection |
54 | A.6āRectifier short circuit current |
55 | AnnexĀ B (informative) Commutating reactance transformation constant and power factor specification B.1āCommutating reactance transformation constant B.2āSpecification of power factor |
56 | AnnexĀ C (informative) Example of current unbalance calculation C.1āData pertaining to the transformer rectifier unit C.2āUnbalance at 100% load under normal operating conditions |
57 | C.3āUnbalance under short circuit conditions |
59 | AnnexĀ D (informative) Bibliography |
60 | Back cover |