Shopping Cart

No products in the cart.

IEEE 325-1986

$35.75

IEEE Standard Test Procedures for Germanium Gamma-Ray Detectors

Published By Publication Date Number of Pages
IEEE 1986 34
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Revision Standard – Inactive-Withdrawn. Terminology and standard test procedures for germanium radiation detectors that are used for the detection and high-resolution spectrometry of gamma rays, X rays, and charged particles that produce hole-electron pairs in the crystal lattice are established so they have the same meaning to both manufacturers and users.

PDF Catalog

PDF Pages PDF Title
8 6 Introduction
6.1 The Interaction of Gamma Rays with Matter
9 1 Scope
2 Object
3 Definitions
13 4 References
5 Symbols
15 6.2 The Germanium Gamma-Ray Detector
Linear Absorption Coefficients versus Gamma-Ray Energy for Si and Ge
16 6.3 Germanium Detector Types
Planar Detectors
Coaxial Germanium Detector Types
17 7 General Requirements
8 Energy Spectroscopy Measurements
8.1 Useful Radionuclide Sources
8.2 Method
Radionuclide Sources for Energy Resolution Measurements
18 8.3 Peak Area and Spectral Background
8.4 Peak Center
8.5 FWHM FW.lM FW.02M of a Peak
Block Diagram of Typical Germanium Gamma-Ray Spectrometer System
19 8.6 Peak-to-Compton Ratio
8.7 Spectral Energy Resolution
Approximations
20 8.8 Total Noise Linewidth and Detector Contribution
Gamma-Ray Spectrum
21 8.9 Peak Asymmetry
8.10 Well-Type Detector Resolution
8.11 Preferred Resolution Energies
Gamma-Ray Spectrum Showing Determination of Peak-to-Compton Ratio
22 9 Counting Efficiency
Efficiency for a Point Source at 25.0 cm
Absolute Full-Energy Peak Counting Efficiency
Relative Full-Energy Peak Counting Efficiency
Peak Asymmetry Ratio H/L
23 Well-Type Coaxial Detector Gamma-Ray Efficiency
Representative Radionuclides for MBSS
24 Beaker Geometry
9.3.1 General
Standard Marinelli Beakers
25 Marinelli Beaker Standard Source (MBSS)
9.3.2.1 Certified MBSS
9.3.2.2 Calibrated MBSS
9.3.2.3 Certified-Solution MBSS
9.3.2.4 Calibrated-Solution MBSS
9.3.2.5 Certified Solution
9.3.3 The Beaker
9.3.4 Radioactive Filling Material
Marinelli Beaker with Solid-state Detector
26 9.3.5 The Measurement
9.3.6 MBSS Documentation
27 Detectors
Ge(Li) Detectors
28 Linear Plot of Spectrum Observed with Ge(Li) Detector Using an MBSS
Log Plot of Spectrum Observed with Ge(Li) Detector using an MBSS
29 10 Window Thickness Index
11 Timing
1325 keV Single Escape Peak of “Y
30 11.1 Measuring System
11.2 Timing Resolution
Timing Measurements
31 12 Temperature Cyclability
12.1 Cyclable Detectors
12.2 Annealable Detectors
Timing Measurement Signals (Unshaped)
32 13 Low-Background Germanium Detectors
Time of a Detector
33 14 Bibliography
Materials Commonly Used in Detector System Construction
Typical Radionuclide Contaminants and Representative Gamma-Ray Energies
IEEE 325-1986