IEEE 386 1985
$24.38
IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Above 600 V
Published By | Publication Date | Number of Pages |
IEEE | 1985 | 30 |
New IEEE Standard – Inactive – Superseded. Service conditions, ratings, interchangeable construction features, and tests for load-break and dead-break separable insulated connector systems rated 601 V and above, 600 A or less, for use on power distribution systems, are established. Included are: corona voltage-level tests, dielectric tests, short-time current test, switching test, fault-closure test, current-cycling tests, accelerated sealing-life test, cable pull-out test, operating-force test, operating-eye test, test-point cap test, test-point tests, and shielding test.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | 200A Load-Break Interface 15.2 kV and 15.2 kV/26.3 kV 200A Load-Break Interface No |
9 | 1 Scope 2 References 3 Definitions |
10 | Typical Components of 200A Separable Insulated Connector System |
11 | Typical Components of 600A Separable Insulated Connector System |
12 | 4 Service Conditions 4.1 Usual Service Conditions 4.2 Unusual Service Conditions 5 Ratings and Characteristics 5.1 Voltage Ratings 5.2 Current Ratings Table 1 Voltage Ratings and Characteristics |
13 | 6 Construction 6.1 Identification 6.2 Operating Means 6.3 Shielding 6.4 Interchangeability 6.5 Test Point 6.6 HOld-DoW Bails Table 2 Current Ratings and Characteristics |
14 | 200A Bushing-Well Interface 8.3 kV 15.2 kV and 21.1 kV |
15 | 200A Dead-Break Interface 8.3 kV and 152 kV |
16 | 200A Load-Break Interface 8.3 kV and 8.3 kV114.4 kV |
17 | 200A Load-Break Probe and Elbow 8.3 kV and 8.3 kV114.4 kV |
18 | 21.1kV and 21.1kV/36.6kV |
19 | 200A Load-Break Interface No 1 21.1 kV and 21.1 kV/36.6kV |
20 | 200 A Dead-Break Interface 21.1 kV |
21 | Fig 10 600A Dead-Break Interface 8.3 kV and 15.2 kV |
22 | Fig 11 600A Dead-Break Interface 21.1 kV |
23 | 7 Testing 7.1 Production Tests 7.2 Design Tests 7.3 Test Conditions Corona Voltage Level 7.5 Dielectric Tests Table 3 Design Tests |
24 | 7.6 Short-Time Current Test 7.7 Switching Test Table 4 Voltage Conditions for Switching Test Table 5 Elbow Spacing for Switching and Fault-Closure Tests |
25 | Fig 12 Circuit Diagrams for Switching Current Tests |
26 | 7.8 Fault-Closure Test Fig 13 Circuit Diagrams for Fault-Closure Tests Table 6 Voltage Conditions for Fault-Closure Test |
27 | Current-Cycling Test for Uninsulated Components of 200 A and 600 A Connectors 7.10 Current-Cycling Test for 200 A Insulated Connectors |
28 | 7.1 1 Current-Cycling Test for 600 A Insulated Connectors Fig 14 Operating Force Test for Option B |
29 | 7.12 Accelerated Sealing Life Test 7.13 Cable Pull-out Test 7.14 Operating-Force Test 7.15 Operating-Eye Test |
30 | 7.16 Test-Point Cap Test 7.17 Test-Point Tests 7.18 Shielding Test |