IEEE 386-1985

$31.96

IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Above 600 V

Published By Publication Date Number of Pages
IEEE 1985 30
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Superseded. Service conditions, ratings, interchangeable construction features, and tests for load-break and dead-break separable insulated connector systems rated 601 V and above, 600 A or less, for use on power distribution systems, are established. Included are: corona voltage-level tests, dielectric tests, short-time current test, switching test, fault-closure test, current-cycling tests, accelerated sealing-life test, cable pull-out test, operating-force test, operating-eye test, test-point cap test, test-point tests, and shielding test.

PDF Catalog

PDF Pages PDF Title
4 200A Load-Break Interface 15.2 kV and 15.2 kV/26.3 kV 200A Load-Break Interface No
9 1 Scope
2 References
3 Definitions
10 Typical Components of 200A Separable Insulated Connector System
11 Typical Components of 600A Separable Insulated Connector System
12 4 Service Conditions
4.1 Usual Service Conditions
4.2 Unusual Service Conditions
5 Ratings and Characteristics
5.1 Voltage Ratings
5.2 Current Ratings
Table 1 Voltage Ratings and Characteristics
13 6 Construction
6.1 Identification
6.2 Operating Means
6.3 Shielding
6.4 Interchangeability
6.5 Test Point
6.6 HOld-DoW Bails
Table 2 Current Ratings and Characteristics
14 200A Bushing-Well Interface 8.3 kV 15.2 kV and 21.1 kV
15 200A Dead-Break Interface 8.3 kV and 152 kV
16 200A Load-Break Interface 8.3 kV and 8.3 kV114.4 kV
17 200A Load-Break Probe and Elbow 8.3 kV and 8.3 kV114.4 kV
18 21.1kV and 21.1kV/36.6kV
19 200A Load-Break Interface No 1 21.1 kV and 21.1 kV/36.6kV
20 200 A Dead-Break Interface 21.1 kV
21 Fig 10 600A Dead-Break Interface 8.3 kV and 15.2 kV
22 Fig 11 600A Dead-Break Interface 21.1 kV
23 7 Testing
7.1 Production Tests
7.2 Design Tests
7.3 Test Conditions
Corona Voltage Level
7.5 Dielectric Tests
Table 3 Design Tests
24 7.6 Short-Time Current Test
7.7 Switching Test
Table 4 Voltage Conditions for Switching Test
Table 5 Elbow Spacing for Switching and Fault-Closure Tests
25 Fig 12 Circuit Diagrams for Switching Current Tests
26 7.8 Fault-Closure Test
Fig 13 Circuit Diagrams for Fault-Closure Tests
Table 6 Voltage Conditions for Fault-Closure Test
27 Current-Cycling Test for Uninsulated Components of 200 A and 600 A Connectors
7.10 Current-Cycling Test for 200 A Insulated Connectors
28 7.1 1 Current-Cycling Test for 600 A Insulated Connectors
Fig 14 Operating Force Test for Option B
29 7.12 Accelerated Sealing Life Test
7.13 Cable Pull-out Test
7.14 Operating-Force Test
7.15 Operating-Eye Test
30 7.16 Test-Point Cap Test
7.17 Test-Point Tests
7.18 Shielding Test
IEEE 386-1985
$31.96