IEEE 751 1991
$84.50
IEEE Trial-Use Design Guide for Wood Transmission Structures
Published By | Publication Date | Number of Pages |
IEEE | 1991 | 119 |
New IEEE Standard – Inactive – Withdrawn. The guide includes definitions, application of loads, structure application, characteristics of natural wood and laminated wood members, design stresses, fabrication of laminated wood members, connections, nonwood members, erection and framing, and quality assurance.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Title Page |
4 | fIntroduction Participants |
6 | CONTENTS |
8 | 1. Introduction 1.1 Scope |
9 | 1.2 References |
13 | 1.3 Definitions |
16 | 2. Structure Application 2.1 General 2.2 Wood Benefits |
17 | 2.3 Wood Limitations 3. Characteristics of Wood 3.1 Physical Characteristics |
22 | 3.2 Mechanical Characteristics |
30 | 4. Structure Loading 5. Structural Analysis and Design 5.1 Introduction |
31 | 5.2 Deterministic Design 5.3 Probabilistic Design |
34 | 5.4 Analysis and Design of Single-Pole Structures |
37 | 5.5 Analysis and Design of Braced (H-frame) Structures |
46 | 5.6 Analysis and Design of Guyed Structures |
49 | 6. Glued Laminated Timber Members 6.1 Laminated Veneer Lumber |
50 | 6.2 Structural Glued Laminated Timber (Glulam) |
51 | 7. Connections and Hardware 7.1 General 7.2 Wood Joint Hardware |
54 | 7.3 Fasteners |
58 | 7.4 Insulator Attachments |
59 | 7.5 Guys and Guy Hardware 7.6 Bearing/Uplift Plates (Pole Anchors) 7.7 Splices 7.8 End Fittings for X-braces, Knee-braces, and Vee-braces |
60 | 8. Nonwood Members 8.1 General 8.2 Strength Characteristics of Nonwood Members 8.3 Designing for Structure Testing |
61 | 9. Erection and Framing 9.1 General 9.2 Handling and Storing Poles and Wood Products |
63 | 9.3 Staking for Wood-Pole Construction 9.4 Hole Digging and Pole Setting |
65 | 9.5 Structure Framing Procedures |
66 | 9.6 Anchor and Guy Installation |
67 | 9.7 Construction Personnel 10. Quality Assurance and Control 10.1 Quality Assurance |
68 | 10.2 Quality Control |
70 | 11. Testing 11.1 General 11.2 Component Tests |
71 | 11.3 Pole Tests 11.4 Structure Tests |
72 | 11.5 Pole-Top Assembly Tests |
73 | 12. Electrical Considerations 12.1 General 12.2 Electrical Properties of Wood |
74 | 12.3 Wood Insulation Design |
75 | 12.4 Structure Electrical Fires 12.5 Structure Grounding |
76 | 12.6 Corona and Electric Effects 12.7 Raptor Considerations 12.8 Maintenance and Safety |
77 | Annex—Sample Problems for Section 5—Structural Analysis and Design |