IEEE 802.3bu 2016:2017 Edition
$52.54
IEEE Standard for Ethernet–Amendment 8: Physical Layer and Management Parameters for Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet
Published By | Publication Date | Number of Pages |
IEEE | 2017 | 77 |
Amendment Standard – Superseded. Specifications and management parameters for the provision of power via a single twisted pair to connected Data Terminal Equipment (DTE) with IEEE 802.3 single balanced twisted-pair interfaces are added by this amendment to IEEE Std 802.3-2015.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 802.3bu-2016 Front Cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
10 | Introduction |
13 | Contents |
17 | 1. Introduction 1.4 Definitions |
18 | 1.5 Abbreviations |
19 | 30. Management 30.2 Managed objects 30.2.2 Overview of managed objects 30.2.2.1 Text description of managed objects 30.2.3 Containment |
21 | 30.2.5 Capabilities |
22 | 30.15 Layer management for Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 30.15.1 PoDL PSE managed object class |
23 | 30.15.1.1 PoDL PSE attributes 30.15.1.1.1 aPoDLPSEID 30.15.1.1.2 aPoDLPSEAdminState 30.15.1.1.3 aPoDLPSEPowerDetectionStatus |
24 | 30.15.1.1.4 aPoDLPSEType 30.15.1.1.5 aPoDLPSEDetectedPDType 30.15.1.1.6 aPoDLPSEDetectedPDPowerClass |
25 | 30.15.1.1.7 aPoDLPSEInvalidSignatureCounter 30.15.1.1.8 aPoDLPSEInvalidClassCounter 30.15.1.1.9 aPoDLPSEPowerDeniedCounter |
26 | 30.15.1.1.10 aPoDLPSEOverLoadCounter 30.15.1.1.11 aPoDLPSEMaintainFullVoltageSignatureAbsentCounter 30.15.1.1.12 aPoDLPSEActualPower 30.15.1.1.13 aPoDLPSEPowerAccuracy |
27 | 30.15.1.1.14 aPoDLPSECumulativeEnergy 30.15.1.2 PoDL PSE actions 30.15.1.2.1 acPoDLPSEAdminControl |
28 | 45. Management Data Input/Output (MDIO) Interface 45.2 MDIO Interface Registers |
29 | 45.2.7b Power Unit Registers 45.2.7b.1 PoDL PSE Control register (Register 13.0) 45.2.7b.1.1 Enable power classification (13.0.1) 45.2.7b.1.2 PSE Enable (13.0.0) 45.2.7b.2 PoDL PSE Status 1 register (Register 13.1) |
30 | 45.2.7b.2.1 Power Denied (13.1.15) |
31 | 45.2.7b.2.2 Valid Signature (13.1.14) 45.2.7b.2.3 Invalid Signature (13.1.13) 45.2.7b.2.4 Class Timeout (13.1.12) 45.2.7b.2.5 Overload (13.1.11) 45.2.7b.2.6 MFVS Absent (13.1.10) 45.2.7b.2.7 PSE Type (13.1.9:7) 45.2.7b.2.8 PD Class (13.1.6:3) 45.2.7b.2.9 PSE Status (13.1.2:0) |
32 | 45.2.7b.3 PoDL PSE Status 2 register (Register 13.2) 45.2.7b.3.1 Invalid Class (13.2.15) 45.2.7b.3.2 PD Type (13.2.2:0) 45.5 Protocol implementation conformance statement (PICS) proforma for Clause 45, MDIO interface 45.5.3 Major capabilities/options |
33 | 45.5.3.13b Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet management functions |
34 | 96. Physical Coding Sublayer (PCS), Physical Medium Attachment (PMA) sublayer and baseband medium, type 100BASE-T1 96.5.4.1 Transmitter output droop 96.8.2.1 MDI return loss |
35 | 104. Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.1 Overview 104.1.1 Compatibility considerations 104.1.2 Relationship of PoDL to the IEEE 802.3 architecture |
36 | 104.1.3 PoDL system types |
37 | 104.2 Link segment |
38 | 104.3 Class power requirements 104.4 Power Sourcing Equipment (PSE) 104.4.1 PSE types |
39 | 104.4.2 PSE classes 104.4.3 PSE state diagram 104.4.3.1 Overview 104.4.3.2 Conventions 104.4.3.3 Variables |
41 | 104.4.3.4 Timers |
42 | 104.4.3.5 Functions |
43 | 104.4.3.6 State diagram |
45 | 104.4.4 PSE detection of a PD 104.4.4.1 Detection probe requirements 104.4.4.2 Detection criteria 104.4.4.3 Rejection criteria |
46 | 104.4.5 PSE classification of a PD 104.4.6 PSE output requirements |
48 | 104.4.6.1 Output voltage 104.4.6.2 Output current 104.4.6.2.1 Output current—at overload condition |
49 | 104.4.6.2.2 Wakeup current signature detection 104.4.6.2.3 Output current requirement during idle 104.4.6.3 Power feeding ripple and transients |
50 | 104.4.6.4 Inrush time 104.4.6.5 Turn off time |
51 | 104.4.6.6 Disable time 104.4.6.7 Continuous output power in POWER_ON state 104.4.7 PSE power removal 104.4.7.1 PSE MFVS requirements 104.5 Powered Device (PD) 104.5.1 PD types 104.5.2 PD classes |
52 | 104.5.3 PD state diagram 104.5.3.1 Overview 104.5.3.2 Conventions 104.5.3.3 Variables |
53 | 104.5.3.4 Timers 104.5.3.5 Functions |
54 | 104.5.3.6 State diagram 104.5.4 PD signature |
55 | 104.5.5 PD classification and mutual identification between the PSE and PD 104.5.6 PD power |
57 | 104.5.6.1 PD discharge 104.5.6.2 PD input voltage 104.5.6.3 Input current |
58 | 104.5.6.4 PD ripple and transients 104.5.6.5 Input average power |
59 | 104.5.6.6 PD stability 104.5.7 PD Maintain full voltage 104.6 Additional electrical specifications 104.6.1 Isolation 104.6.2 Fault tolerance |
60 | 104.7 Serial communication classification protocol (SCCP) 104.7.1 SCCP signaling 104.7.1.1 Initialization procedure—reset and presence pulses 104.7.1.2 Write time slots |
61 | 104.7.1.3 Read time slots |
63 | 104.7.2 Serial communication classification protocols 104.7.2.1 SCCP transaction sequence 104.7.2.2 Initialization 104.7.2.3 Address commands 104.7.2.3.1 Broadcast address [0xCC] 104.7.2.4 Read_Scratchpad function command [0xAA] 104.7.2.5 CRC8 field |
65 | 104.8 Environmental 104.8.1 General safety 104.8.2 Network safety 104.8.3 Installation and maintenance guidelines |
66 | 104.8.4 Patch panel considerations 104.8.5 Telephony voltages 104.8.6 Electromagnetic emissions 104.8.7 Temperature and humidity |
67 | 104.9 Protocol implementation conformance statement (PICS) proforma for Clause 104, Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.9.1 Introduction 104.9.2 Identification 104.9.2.1 Implementation identification 104.9.2.2 Protocol summary |
68 | 104.9.3 Major capabilities/options 104.9.4 PICS proforma tables for Clause 104, Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet 104.9.4.1 Link Segment |
69 | 104.9.4.2 Power Sourcing Equipment (PSE) |
72 | 104.9.4.3 Powered Device (PD) |
74 | 104.9.4.4 Common Electrical 104.9.4.5 PSE Electrical 104.9.4.6 PD Electrical 104.9.4.7 SCCP |
76 | 104.9.4.8 Environmental |
77 | Back cover |