IEEE 823 1990
$44.42
IEEE Standard Methodologies for Specifying Voicegrade Channel Transmission Parameters and Evaluating Connection Transmission Performance for Speech Telephony
Published By | Publication Date | Number of Pages |
IEEE | 1990 | 72 |
New IEEE Standard – Inactive – Withdrawn. Withdrawn Standard. Withdrawn Date: Dec 13, 1994. No longer endorsed by the IEEE. This standard provides network planners with the methodology and models for calculating the transmission performance of connections made up of one channel or of two or more tandem channels. The performance parameters covered include connection loss, idle-circuit and quantisation noise, and talker echo path loss and delay. The methodology is given for determining the speech transmission performance and grade of service of a complete voice connection including the terminals (telephone sets), and evaluating the relative performance of alternative speech connections.
PDF Catalog
PDF Pages | PDF Title |
---|---|
11 | 1 Introduction |
12 | 2 Purpose Scope and Application 2.1 Purpose 2.2 Scope 2.3 Application |
13 | for Speech Telephony |
14 | Definitions Illustration of Some Definitions |
15 | 4 Summary of Standards 4.1 Introduction Specification of Channel Parameters |
16 | Summary of Procedure |
18 | Calculation of Complete Connection Parameters 4.5 Performance Evaluation 5.1 General |
19 | 5.2 Loss 5.2.1 Effect of Connection Loss on Performance 5.2.2 Definition Method and Units of Measurement 5.2.4 Method of Specification of Channel Loss 5.2.5 Method for Calculating Connection Loss |
20 | 5.3 Idle-Circuit Noise 5.3.1 Effect of Idle-Circuit Noise on Performance 5.3.2 Definition Method and Units of Measurement |
21 | 5.3.4 Method of Specification of Channel Idle-Circuit Noise 5.3.5 Method for Calculating Connection Idle-Circuit Noise Connection Loss Example |
22 | 5.4 Quantization Noise Effect of Quantization Noise on Performance Method and Units of Measurement 5.4.4 Method of Specification of Channel Quantization Noise |
23 | 5.4.5 Methodology for Calculating Connection Quantization Noise Connection Idle-Circuit Noise Example |
24 | Talker Echo Path Loss 5.5.1 Effect of Talker Echo Path Loss on Performance 5.5.2 Definitions Method and Units of Measurements Connection Quantization Noise Example |
25 | 5.5.4 Method of Specification of Channel Talker Echo Path Loss |
26 | for a Channel |
27 | Method of Determining Dominant Channel Talker Echo Paths |
28 | 5.5.5 Method for Calculating Connection Talker Echo Path Loss |
29 | Determination of Dominant Connection Talker Echo Paths |
30 | Talker Echo Path Delay Performance 5.6.2 Definitions Method and Units of Measurement 5.6.4 Method of Specification of Channel Talker Echo Path Delay |
31 | 5.6.5 Method for Calculating Connection Talker Echo Path Delay 6 Connection Performance for Speech Transmission 6.1 Introduction |
32 | Connection 6.2.1 General 6.2.2 Loudness Loss |
33 | 6.2.3 Equivalent Noise 6.2.4 Talker Echo |
34 | Illustration of Talker Echo in a Complete Connection |
35 | Methodology for the Evaluation of the Performance of a Complete Connection 6.3.1 General 6.3.2 Performance Comparison Method |
36 | Loudness Loss-Equivalent Noise Performance Classes |
38 | 6.3.3 Performance Class Descriptions Talker Echo Performance Classes for Delays > 100 ms < 1200 ms |
39 | 7 References |
41 | Application Examples |
42 | Off-Premises Station (OPS) Channel Specification |
44 | Example of a Complete Connection |
46 | Loss-Noise Performance of Example Complete Connection |
48 | Example of Alternative Connection Arrangements Table A1 Alternative Arrangements |
49 | Connection Parameters |
56 | Application of Echo Control Devices |
57 | Illustrative Example of TEPL and Equal Level TEPL |
60 | Receiving Systems |
61 | General Case for TOLR’ and ROLR’ |
62 | TOLR and ROLR According to EIA 470-A (1987) [Cl] and IEEE Std 661-1979 [C21 |
63 | Table C1 Estimated Values TOLR’ and ROLR’ Table C2 Loudness Ratings for 500-Type Set with 26-Gauge Subscriber Lines |
64 | Table C3 1004 Hz 900 R Insertion Loss of 26-Gauge Cable Table C4 Loudness Rating Distribution for 500-Type Set Model on 1973 Customer Loops Table C5 Loudness Ratings for 500-Type Set Model on Short Loops |
65 | Bridge Bridge |
67 | Criteria and Methodology Used in Defining the Performance Classes |
68 | CCITT Opinion Data D31, [D41 |
70 | Classification Table D2 Speech Performance Classes of Voicegrade Connections |