Revision Standard – Active. This guide covers the application of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and utility installations. It deals with usage under varied service conditions, temperature conditions affecting continuous current compensation, reduced dielectrics, reclosng derating as applicable, calculation of system short-circuit current, compensation at different X/R ratios, detailed calculations with application curves, out-of-phase switching, and general application.

PDF Catalog

PDF Pages PDF Title
1 Title Page
3 Introduction
4 Participants
7 CONTENTS
9 1. Scope
2. References
11 3. Definitions
4. General service conditions
4.1 Usual service conditions
4.2 Unusual service conditions
15 4.3 Mechanical considerations for outdoor circuit breakers
5. Application considerations
16 5.1 Maximum voltage for application
5.2 Voltage range factor
5.3 Frequency
5.4 Continuous current
30 5.5 Rated dielectric withstand
5.6 Standard operating duty
31 5.7 Interrupting time
32 5.8 Permissible tripping delay T (determined by short-time current test duration)
33 5.9 Reclosing time
37 5.10 Short-circuit current rating
38 5.11 Transient recovery voltage
39 5.12 Load current switching capability and life (repetitive operation)
5.13 Capacitance current switching
5.14 Line closing (line-closing switching surge factor)
40 5.15 Conditions of use with respect to the out of phase switching current rating
41 5.16 Shunt reactor current switching
5.17 Transformer current switching
5.18 Mechanical endurance
42 5.19 Rated control voltage
5.20 Fluid operating pressure
5.21 Insulating oil for circuit breaker
5.22 Closed pressure system (gas-filled)
6. Short circuit considerations
6.1 System short circuit currents
44 6.2 Selection of applicable circuit breaker ratings
6.3 Methods for calculating system short circuit currents
55 6.4 Electrical quantities used
62 Annex A—Basis for E/X method corrected for ac and dc decrements in the calculation of short-circuit currents
75 Annex B—Special application circuit breakers for ac motor starting
79 Annex C—Bibliography