IEEE C37.013-1989
$46.04
IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis
Published By | Publication Date | Number of Pages |
IEEE | 1989 | 46 |
New IEEE Standard – Superseded. This standard applies to all AC high-voltage generator circuit breakers rated on a symmetrical current basis, with rated maximum voltage 15.8 kV and above with a continuous current rating of 6.3 kA and above that are applied to generator terminals. Pumped storage installations are considered a special application, and their requirements are not completely covered by this standard
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | 1 Scope and References 1.1 Scope 1.2 References 2 Definitions |
10 | 2.1 Design Tests 2.2 Production Tests 2.3 Tests After Delivery 3 Service Conditions 3.1 Usual Service Conditions 3.2 Unusual Service Conditions |
11 | 3.3 Impact on Environment 4 Ratings and Required Capabilities 4.1 Rated Maximum Voltage Table 1 Altitude Correction Factors |
12 | Table 2 Preferred Ratings for Generator Circuit Breakers |
13 | 4.2 Rated Voltage Range Factor K 4.3 Rated Frequency 4.4 Rated Continuous Current Table 3 Temperature Limitations on Insulating Materials for Continuous Ratings |
14 | Table 4 Temperature Limitations on Main Contacts for Continuous Ratings Table 5 Temperature Limitations on Conducting Joints for Continuous Ratings |
15 | 4.5 Rated Dielectric Strength Cooling Required for Rated Continuous Current |
16 | Insulation |
17 | 4.6 Rated Short-circuit Duty Cycle 4.7 Rated Interrupting Time 4.8 Rated Permissible Tripping Delay Y 4.9 Rated Closing Time 4.10 Short-circuit Current Rating |
18 | Three-phase System-Source Short-circuit Current |
20 | Parting Times Shown |
21 | 4.11 Transient Recovery Voltage (TRV) Rating 4.12 Rated Load Current Switching Capability |
22 | Table 7 TRV Parameters for System-Source Faults Table 8 TRV Parameters for Generator-Source Faults Table 9 Operation Endurance Capabilities for Generator Circuit Breakers |
23 | Table 10 TRV Parameters for Load Current Switching Table 11 TRV Parameters for Out-of-Phase Switching |
24 | Table 12 Rated Control Voltages and Their Ranges for Generator Circuit Breakers |
25 | 4.13 Capacitance Switching Current 4.14 Out-of-Phase Switching Current 4.15 Excitation Current Switching Capability 4.16 Rated Control Voltage (Nominal Control Voltage) 4.17 Rated Mechanism Fluid Operating Pressure 4.18 Nameplate Markings |
26 | 5 Tests 5.1 General |
27 | 5.2 Design Tests |
33 | Conditions for Single-Pole Tests |
39 | Three-Pole Tests or Conditions for Single-Pole Tests |
40 | Fig 6 Single Voltage Testing with One Side Grounded |
42 | 5.3 Production Tests |
45 | 5.4 Tests After Delivery |