IEEE C37.06 2009
$43.88
IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis–Preferred Ratings and Related Required Capabilities for Voltages Above 1000 V
Published By | Publication Date | Number of Pages |
IEEE | 2009 | 60 |
New IEEE Standard – Active. The preferred ratings of indoor and outdoor high-voltage circuit breakers rated above 1000 V for use in commercial, industrial, and utility installations are described in this standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.06-2009 Front cover |
3 | Title page |
6 | Introduction |
9 | Notice to users Laws and regulations |
10 | Copyrights Updating of IEEE documents Errata Interpretations Patents |
11 | Participants |
13 | Contents |
15 | Important notice 1. Overview 1.1 Scope 1.2 Purpose |
16 | 1.3 Preferred ratings 2. Normative references |
17 | 3. General applications to circuit breakers 4. Basic definitions applied in this standard |
18 | 5. Preferred ratings for Class S1 circuit breakers for cable systems |
21 | 5.1 Information for Table 1, Table 2, and Table 3 |
24 | 5.2 Information for Table 4 on preferred capacitance current switching ratings for Class S1 cable systems circuit breakers rated below 100 kV |
25 | 6. Preferred rating for Class S2 circuit breakers for line systems rated below 100 kV |
26 | 6.1 Information for Table 5 |
29 | 6.2 Information for Table 6 and Table 7 |
32 | 6.3 Information for Table 8 on preferred capacitance current switching ratings for Class S2 line systems circuit breakers rated below 100 kV |
33 | 7. Preferred ratings for circuit breakers rated 100 kV and above |
34 | 7.1 Information for Table 9 |
39 | 7.2 Information for Table 10, Table 11, and Table 12 |
42 | 7.3 Information for Table 13 |
45 | 7.4 Information for Table 14 on preferred capacitance current switching ratings for circuit breakers rated 100 kV and above, including circuit breakers applied in gas-insulated substations |
46 | 8. Preferred dielectrics withstand ratings for circuit breakers |
49 | 8.1 Information for Table 15 and Table 16 9. Circuit-breaker operation and operating endurance capabilities |
51 | 9.1 Information for Table 17 |
52 | 10. Control voltage ranges for circuit breakers 10.1 Information for Table 18 |
54 | 11. Rated reclosing times for circuit breakers 11.1 Information for Table 19 |
55 | Annex A (normative) TRV symbols used in the tables with the two-parameter method A.1 General explanation of symbols |
56 | A.2 Figures explaining the symbols |
57 | Annex B (normative) Symbols used in the tables with the four-parameter method B.1 General explanation of symbols |
58 | B.2 Figures explaining the symbols |
60 | Annex C (informative) Bibliography |