IEEE C37.081 1981

$83.96

IEEE Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis

Published By Publication Date Number of Pages
IEEE 1981 35
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Active. This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Guidelines are established for synthetic testing of circuit breakers, as well as test criteria for demonstrating the short-circuit current rating of circuit breakers on a single-phase basis. Criteria for evaluating results are also provided. The standard covers short-circuit current interruption process; basic principles of synthetic testing; synthetic test circuits; requirements for synthetic test methods; parameters, test procedures, and tolerances; short-line fault; multiple loops; circuit breakers equipped with parallel impedance; duty cycle; and test records. You will receive an email from Customer Service with the URL needed to access this publication online.

PDF Catalog

PDF Pages PDF Title
1 Title Page
3 Introduction
Participants
6 CONTENTS
9 1. Introduction
1.1 General
1.2 Scope and Purpose
10 2. Definitions
3. References
11 4. Short-Circuit Current Interruption Process
4.1 Circuit Breaker Performance During Interruption; Basic Intervals
12 4.2 State of Interrupting Process
5. Basic Principles of Synthetic Test
5.1 Principles
5.2 Basic Components
13 6. Synthetic Test Circuits
6.1 Current Injection Method
16 6.2 Voltage Injection Method
6.3 Duplicate Circuit Method
17 6.4 Synthetic Test Circuits; Choice of Methods
7. Requirements for Synthetic Test Methods
18 7.1 High-Current Interval
7.2 Interaction Interval
7.3 High-Voltage Interval
7.4 Discussion
8. Parameters, Test Procedures, and Tolerances
8.1 High-Current Interval; Voltage of Current Circuit
20 8.2 Interaction Interval—Current Injection Circuit
21 8.3 HIgh-Voltage Circuit
23 9. Short-Line Fault
10. Multiple Loops
10.1 Method with Single Application of the Voltage Circuit
24 10.2 Method with Multiple Application of Voltage Circuits
11. Circuit Breakers Equipped with Parallel Impedance
11.1 General
25 11.2 Four Part Test Method
26 12. Duty Cycle
12.1 Test Duties for Synthetic Testing
27 12.2 Test Methods
29 13. Test Records
13.1 General
13.2 Current Measurements
13.3 Voltage Measurements
31 Annex A—Distorted Current; Derivation