IEEE C37.101 1984

$21.67

IEEE Guide for Generator Ground Protection

Published By Publication Date Number of Pages
IEEE 1984 43
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Inactive – Superseded. Guidance in the application of relays and relaying schemes for protection against stator ground faults on high-impedance grounded generators is provided.

PDF Catalog

PDF Pages PDF Title
7 I. Introduction
Summary of Protection Schemes
8 SchemeNumbers
11 5 GroundingMethods
12 Method I Distribution-Transformer Grounded (High Resistance
Method 11 Neutral-Resistor Grounded (High Resistance)
Method 111 Neutral-Resistor Grounded (Low Resistance
Method IV Neutral-Reactor Grounded (Low Inductive Reactance)
5.5 Method V Ground-Fault Neutralizer Grounded (Tuned Inductive Reactor
Method VI Grounding Transformer Grounded (High Resistance)
13 Method VII Grounding Transformer Grounded (Medium Resistance)
Method VIII Ungrounded
6 Protective Schemes
14 Scheme 1 Ground Overvoltage-Complete Shutdown
Scheme 1 Ground Overvoltage-Complete Shutdown
15 Scheme 2 Ground Overvoltage-Permissive Shutdown
16 Scheme 3 Ground Overvoltage-Alarm and Time-Delay Shutdown
Scheme 4 Ground Overvoltage-Alarm
Scheme 5S Startup Ground Overvoltage-Complete Shutdown
Scheme 2 Ground Overvoltage-Permissive Shutdown
Scheme 3 Ground Overvoltage-Alarm and Time-Delay Shutdown
Scheme 4 Ground Overvoltage-Alarm
17 Orderly ShuMown
Scheme 5s Startup Ground Overvoltage-Complete Shutdown
Orderly Shutdown
18 Overvoltage-Complete Shutdown
Scheme 7 Wye-Broken-Delta VT Ground Overvoltage-Complete Shutdown
19 Overvoltage-Complete Shutdown
Ground Overcurrent-Complete Shutdown
Shutdown
Complete Shutdown
20 Ground Overcurrent-Complete Shutdown
Shutdown,orBoth
CompleteShutdown
21 Scheme 12 Generator Leads Ground Overcurrent-Complete Shutdown
Complete Shutdown or Both
Scheme 12 Generator Leads Ground Overcurrent-Complete Shutdown
22 Instantaneous Ground Overcurrent-Complete Shutdown
Overcurrent-Complete Shutdown
23 Instantaneous Ground Overcurrent-Complete Shutdown
Scheme 15 Generator Percentage Differential-Complete Shutdown
Overcurrent-Complete Shutdown
Overcurrent-Complete Shutdown
24 Differential- Complete Shutdown
Scheme 15 Generator Percentage Differential-Complete Shutdown
Overcurrent-Complete Shutdown
25 Protective Device Function Numbers
Complete Shutdown
27 Generator-Ground Protection; Other Practices
28 Scheme A 3rd Harmonic Neutral Voltage
29 Scheme B 3rd Harmonic Terminal to Ground Residual Voltage
30 Scheme C 3rd Harmonic Ratio Differential Quantities
Scheme D Neutral or Residual Voltage Injection
31 GroundFaults
32 Scheme F Residual High-Impedance Generator Differential
Percentage Differential
33 Generator Ground Protection Examples
Typical Generator Ground Protection One Line Diagram
34 Phase to Ground-Fault Symmetrical Component Equivalent Circuits
36 PhasorDiagrams
40 Relay and Fuse Coordination Curves
42 Appendix C Bibliography