New IEEE Standard – Inactive – Withdrawn. Withdrawn Standard. Withdrawn Date: May 20, 1996. No longer endorsed by the IEEE. The following topics were dealt with: IEEE C37.103-1990, IEEE Guide for Differential and Polarizing Relay Circuit Testing, covers the testing and verification required to ensure correct connections for ground relay polarizing and differential relay connections. Relay calibration, setting, insulation, and instrument transformer tests are referred to in this guide and are assumed to be developed by the individual user. This guide is not intended to discuss these aspects in detail.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Fig |
7 | Fig |
9 | 1 Introduction 1.1 References Safety Considerations for Personnel and Equipment 2.1 Primary Testing 2.2 Secondary Testing Fig |
10 | 2.3 Current Transformer Circuits 2.4 Current Transformer Short Circuiting Devices Preparatory Tests 3.1 Current Transformers 3.1.1 Ratio Test 3.1.2 Polarity Test 3.1.3 Excitation Test 3.1.4 Resistance Measurement 3.1.5 Insulation Test Fig |
11 | 3.2 Wiring Checks Ratio Check of Current Transformer Within Delta Winding Excitation Test-More Than One Current Transformer Within Delta Winding Fig |
12 | 3.3 Test Switches 3.3.1 Test Jacks 3.3.2 Current Shorting Switch 3.4 Test Equipment 3.4.1 Transformer Loading 3.4.2 Resistance Loading Typical Test Switch Fig |
13 | 3.4.3 Solid-State or Electronic Techniques 3.4.4 Size 3.4.5 Accuracy 3.4.6 Waveform 4 Power Supplies for Testing 4.1 AC Current Secondary Injection Testing 4.2 AC Current -Primary Injection Testing 4.3 DC Current Primary and Secondary Injection Testing l Fig |
14 | Generator Motor and Reactor Differential Relaying 5.1 Primary Current Injection Testing Fig |
15 | Generator Differential-Primary Current Injection Through Winding Fig |
16 | Transformer Window Fig |
17 | Generator Differential Secondary Current Injection Fig |
18 | 5.3 In-service Testing 6 Bus Differential Relaying 6.1 Primary Current Injection Testing Fig |
19 | Bus Differential-Current Transformers-Primary Current Injection Bus Differential-Linear Couplers Primary Current Injection Fig |
20 | Fig |
21 | 7.1 Primary Current Injection Testing 7.1.1 Current Transformers Located in Breakers 7.1.2 Current Transformers Located in the Transformer 7.2 Secondary Current Injection Testing Fig |
22 | Breaker Fig |
23 | Transformer Fig |
24 | Fig |
25 | Transformer Differential-Secondary Current Injection-Method Fig |
26 | 8 Potential Polarized Phase Relays 8.1 Primary Current Injection Testing 8.2 Secondary Injection Testing 8.2.1 Current Circuit Current Injection Testing Fig |
27 | Directional Phase Relay Current Circuit-Primary Current Injection |
28 | 8.2.2 Current Circuit Voltage Injection Testing 8.2.3 Voltage Circuit Voltage Injection Testing Directional Phase Relay Current Circuit-Secondary Current Injection |
29 | 8.3 In-service Test 9 Potential Polarized Ground Relays 9.1 Voltage Circuit Secondary Voltage Injection Testing |
30 | 9.2 In-Service Test (Refer to Fig Directional Phase Relay Current Circuit-Secondary Voltage Injection |
32 | Method |
33 | 10 Neutral Current Polarized Ground Relays 10.1 Primary Current Injection Testing Primary of All Current Transformers Accessible Directional Ground Relay Voltage Circuit Secondary voltage Injection-Method |
34 | Accessible 11 Tertiary Current Polarized Ground Relays Breaker Current Transformers Accessible 11.1.1 Closing Torque Test (Method 11.1.2 Opening Torque Test (Method |
35 | Directional Ground Relay Voltage Circuit Secondary Voltage Injection-Method |
36 | Directional Ground Relay Directional Check In-service Quantities |
37 | Transformer Current Polarize Circuit Primary Current Injection-Method |
39 | Transformer Current Polarize Circuit Primary Current Injection-Method |
40 | Transformer Current Polarize Circuit Primary Current Injection-Method |
42 | Method |
43 | Results of IEEE Survey |