Revision Standard – Active. Revision of IEEE Std C37.110-1996. The characteristics and classification of current transformers (CTs) used for protective relaying are described. This guide also describes the conditions that cause the CT output to be distorted and the effects on relaying systems of this distortion. The selection and application of CTs for the more common protection schemes are also addressed.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.110ā„¢-2007 Front cover
3 Title page
6 Introduction
Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata
7 Interpretations
Patents
Participants
10 Contents
13 Important notice
1. Overview
1.1 Scope
1.2 Purpose
2. Normative references
14 3. Definitions
16 4. Current transformer characteristics and classification
4.1 Current transformer equivalent circuit and phasor diagrams
18 4.2 Current transformer secondary excitation characteristics
19 4.3 Knee-point voltage
20 4.4 Current transformer accuracy
23 4.5 Dynamic characteristics
31 4.6 The effects of remanence
34 4.7 Fundamental transformer equation
35 5. General application of current transformers
5.1 Current transformer burdens
37 5.2 Ratio selection
5.3 Long-term and short-term thermal ratings
38 5.4 Current transformer secondary output accuracy class voltage
39 5.5 Connecting current transformers in series
5.6 Three-phase connections
40 5.7 Auxiliary current transformers
5.8 Bus configuration
41 5.9 Current transformer location
42 5.10 Minimizing the effects of current transformer saturation
5.11 Determining current transformer steady-state performance using secondary excitation curves
43 6. Effects of current transformer saturation on relays
6.1 Saturation effects on electromechanical relays
6.2 Saturation effects on static relays
44 6.3 Saturation effects on differential relays
6.4 Unbalanced current measurement
45 6.5 Current transformer performance under geomagnetic-induced current conditions
7. Specific applications of current transformers
7.1 Overcurrent relays
49 7.2 Differential protection
66 7.3 Distance protection
68 7.4 Other types of high-speed protection
69 Annex A (informative) IEC standards on current transformers
72 Annex B
(informative) List of ANSI C accuracy class values and burdens
73 Annex C
(informative) Remanent flux in current transformers
74 Annex D (informative) Optical current sensor systems
77 Annex E
(informative) Bibliography
IEEE C37.110-2007