IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker Switchgear (Redline)

Published By Publication Date Number of Pages
IEEE 2016 29
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. Definite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear are covered in this standard. The switching devices are fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are addressed in this standard. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.13.1™-2016 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Participants
8 Introduction
9 Contents
10 1. Overview
1.1 Scope
1.2 Purpose
2. Normative references
11 3. Definitions
4. Normal service condition
12 5. Ratings
5.1 General
13 5.2 Rated maximum voltage
5.3 Rated power frequency
5.4 Rated continuous current
5.5 Rated short-circuit current
5.6 Rated control voltage
14 6. Functional components
6.1 General
6.2 Nameplate(s)
15 6.3 Contact position indicator
6.4 Stored-energy indicator (for stored-energy type-closing mechanisms only)
6.5 LV-DPS device retention and locking
6.6 Fuse accessibility
6.7 Interlocks
16 6.8 Secondary disconnect devices
6.9 Removable element interchangeability
7. Temperature limitations and classification of insulting materials
7.1 Temperature limits
7.2 Limits of temperature rise
17 8. Tests
8.1 General
8.2 Design (type) test
20 8.3 Production (routine) tests
21 8.4 Field dielectric test
22 Annex A (informative) Bibliography
23 Annex B (informative) Application guide
B.1 General
27 B.2 Application of LV-DPS devices to full-voltage starting and running duty of three-phase 60 Hz motors
B.3 Application of LV-DPS devices for capacitance switching
B.4 Service condition affecting LV-DPS device application
28 B.5 Repetitive duty operations and normal maintenance