IEEE C37.13 2015

$23.33

IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures

Published By Publication Date Number of Pages
IEEE 2015 46
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. The following enclosed low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.13-2015 Front Cover
3 Title page
5 Important Notices and Disclaimers Concerning IEEE Standards Documents
8 Participants
10 Introduction
12 Contents
14 Important Notice
1. Overview
1.1 Scope
15 1.2 Purpose
2. Normative references
16 3. Definitions
17 4. Service conditions
5. Ratings
5.1 General
18 5.2 Rated maximum voltage
5.3 Rated power frequency
5.4 Rated frame size
5.5 Rated continuous current
19 5.5.1 Preferred electronic trip system current ratings and settings
5.5.2 Preferred electromechanical trip system current ratings and settings
5.6 Rated short-circuit current
5.6.1 General
20 5.6.2 Circuit breaker (50 Hz or 60 Hz)
5.6.3 Circuit breaker (50/60 Hz)
5.6.4 Unfused circuit breakers
21 5.6.5 Fused circuit breakers
5.6.5.1 Integrally and nonintegrally fused circuit breakers
22 5.6.5.2 Nonintegrally fused circuit breakers—Fuse drawout assembly
5.6.5.3 Fused circuit breaker frames
23 5.7 Rated short-time current and short-time current duration
5.7.1 Unfused circuit breakers
5.7.2 Fused circuit breakers
5.8 Rated control voltage
25 6. Functional components
6.1 General
6.2 Nameplate(s)
26 6.3 Manual releases
27 6.4 Contact position indicator
6.5 Stored energy indicator
6.6 Open-fuse trip device
6.7 Locking
6.8 Primary disconnect devices
28 6.9 Circuit breaker ground connection
6.10 Fused drawout assembly
7. Temperature limitations and classification of insulating materials
7.1 Temperature limits
7.2 Limits of temperature rise
7.3 Classification of insulating materials
7.3.1 Flame-resistant capabilities
7.3.1.1 Insulating materials in contact with primary voltage parts
29 7.3.1.1.1 Sheet insulating materials
7.3.1.1.2 Molded or cast insulating materials
7.3.1.2 Insulating materials not in contact with primary voltage parts
7.3.1.2.1 Polymeric materials
7.3.1.2.2 Non-polymeric materials
30 7.3.2 Thermal capabilities
7.3.3 Tracking capabilities
8. Test procedures
8.1 Retest schedule
8.2 Test values
8.2.1 General
8.2.2 Dielectric withstand test voltage values
31 8.3 Overload and endurance
32 Annex A (informative) Application guide
45 Annex B (informative) Bibliography
46 Back Cover