IEEE C37.17-2022
$33.58
IEEE Standard for Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers (Published)
Published By | Publication Date | Number of Pages |
IEEE | 2022 |
Revision Standard – Active. This standard pertains to the requirements for current and voltage protective functions of 1) direct-acting overcurrent electromechanical trip devices, 2) direct-acting overcurrent electronic trip systems, 3) reverse-current trip systems, and 4) undervoltage trip devices that are integral with low-voltage ac (1000 V and below) and general-purpose low-voltage dc (1500 V and below) power circuit breakers covered by IEEE Std C37.13 and IEEE Std C37.14. Additional information, communication, and/or additional internal or external protective functions or devices are not covered by this standard. This standard should not be interpreted to restrict the inclusion of such functionality in the device.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.17ā¢-2022 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | 1.āOverview 1.1āScope 1.2āWord usage |
14 | 2.āNormative references 3.āDefinitions |
16 | 4.āPreferred trip device current ratings or settings (amperes) 5.āTrip system self-monitoring 5.1āGeneral |
17 | 5.2āTrip system health indication 5.3āTrip actuator circuit integrity 5.4āCurrent sensing circuit integrity 6.āTypes and response of direct-acting overcurrent trip functions 6.1āGeneral 6.2āLong-time delay 6.3āShort-time delay 6.4āInstantaneous |
18 | 6.5āNeutral overload 6.6āGround fault 6.7āFunctions modifying the response of direct-acting overcurrent trip functions |
19 | 7.āRequirements for direct-acting overcurrent trip functions 7.1āGeneral 7.2āLong-time delay trip functions (electromechanical devices only) 7.3āLong-time delay trip functions (electronic devices only) 7.4āShort-time delay trip functions 7.5āInstantaneous trip functions (low range electromechanical devices only) |
20 | 7.6āInstantaneous trip functions (electronic devices only) 7.7āNeutral overload functions 7.8āGround fault trip functions 8.āDelay times of direct-acting overcurrent trip functions 8.1āLong-time-delay trip functions 8.2āShort-time-delay trip functions 8.3āShort-time-delay ground fault trip function 9.āReverse-current trip devices for general purpose dc circuit breakers 10.āUndervoltage trip devices 10.1āGeneral |
21 | 10.2āDrop-out voltage range 10.3āPickup or seal-in voltage 10.4āMaximum operating voltage 11.āTests 11.1āGeneral 12.āSoftware process verification |
24 | Annex A (informative) Time-overcurrent characteristics A.1āSample phase time-overcurrent characteristics and tolerance bands |
25 | A.2āSample ground time-overcurrent characteristics and tolerance bands |
26 | A.3āDiagram clarifying Table 3 |
27 | Annex B (informative) Arc flash mitigation or energy reduction integral to the trip system |
28 | Annex C (informative) Use of trip systems not originally supplied/offered/qualified with the breaker by the original circuit breaker manufacturer |
29 | Annex D (informative) Definitions preserved for historical continuity |
30 | Annex E (informative) Bibliography |
31 | Back cover |