Shopping Cart

No products in the cart.

IEEE C37.20.3 1987

$61.75

IEEE Standard for Metal-Enclosed Interrupter Switchgear

Published By Publication Date Number of Pages
IEEE 1987 48
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Inactive – Superseded. Metal-enclosed interrupter switchgear assemblies rated above 1000V containing but not limited to such devices as interrupter switches, selector switches, power fuses, control, instrumentation and metering, and protective equipment are covered. The concern is with equipment for the control and protection of apparatus used for distribution of electrical power, but the standard is not specifically limited to such equipment. Equipment that is part of primary and secondary unit substations is included. Gas-insulated substation equipment and switching devices mounted integrally within a transformer enclosure are not covered.

PDF Catalog

PDF Pages PDF Title
1 Title Page
3 Introduction
Participants
7 CONTENTS
9 1. Scope and References
1.1 Scope
1.2 References
11 2. Definitions
13 3. Service conditions
4. Ratings
4.1 General
14 4.2 Voltage and Insulation Levels
15 4.3 Rated Frequency
4.4 Rated Current
16 4.5 Temperature Limitations
18 4.6 Current Transformer Ratings
4.7 Current Transformer Accuracies
5. Tests
5.1 General
5.2 Design Tests
26 5.3 Production Tests
28 5.4 Conformance Tests
5.5 Field Dielectric Tests
6. Construction
6.1 General Requirements
32 6.2 Materials and Finish
33 6.3 Barriers
6.4 Buses and Connections
6.5 Interlocks
6.6 Indoor MEI Switchgear, Access, and Ventilation
6.7 Outdoor MEI Switchgear, Access, and Ventilation
34 6.8 Shutters
6.9 Precautionary Labels
6.10 Enclosure Categories
7. Application Guide for MEI Switchgear
7.1 Unusual Service Conditions
37 7.2 System Characteristicsā€”Voltage and Frequency
7.3 Overvoltage Considerationsā€”Insulation Levels
7.4 Continuous Current Rating and Overload Capability
38 7.5 Short-Circuit Considerations
7.6 Nuclear Power Plant Application
7.7 Exposed Circuits
7.8 Surge Arresters in Switchgear Assemblies
7.9 Protection and Isolation of Switchgear Connected to Other Switching Equipment
7.10 Current Transformer Accuracies
39 8. Guide for Handling, Storage, and Installation
8.1 General
8.2 Handling
40 8.3 Preoperation Check
41 8.4 Interrupter Switches
8.5 Interlocks
8.6 Energization
42 Annex Aā€”Guide for Enclosure Categories and Related Requirements
IEEE C37.20.3 1987
$61.75