IEEE C37.23 2016
$37.08
IEEE Standard for Metal-Enclosed Bus
Published By | Publication Date | Number of Pages |
IEEE | 2016 | 80 |
Revision Standard – Active. Metal-enclosed (ME) bus assemblies for indoor and outdoor use are discussed in this standard. The types of assemblies covered are nonsegregated-phase bus, cable bus, segregated-phase bus, and isolated-phase bus. Rated maximum voltages of ac ME bus assemblies range from 1058 V through 38 kV with continuous-current ratings of 600 A through 26 000 A for self-cooled ratings and up to 50 000 A for forced-cooled ratings. Rated maximum voltage levels of dc ME bus assemblies range from 300 V through 3200 V with continuous-current ratings of 600 A through 15 000 A. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed. A guide for calculating losses in isolated-phase bus is included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.23-2015 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
11 | Contents |
12 | IMPORTANT NOTICE 1. Overview 1.1 Scope 1.2 Purpose |
13 | 2. Normative references |
14 | 3. Definitions |
17 | 4. Normal (usual) service conditions |
18 | 5. Ratings 5.1 General 5.2 Voltage and insulation levels |
20 | 5.3 Rated power frequency 5.4 Rated current |
25 | 6. Tests 6.1 General |
26 | 6.2 Design tests |
35 | 6.3 Production tests |
36 | 6.4 Field tests |
37 | 7. Construction 7.1 Materials and finish |
38 | 7.2 Grounding 7.3 Adjacent and supporting structure 7.4 Ventilation |
39 | 7.5 Forced cooled |
40 | 7.6 Vapor barriers 7.7 Fire barriers |
41 | 7.8 Insulating materials for covering buses and connections 7.9 Terminations and flexible connections 7.10 Switches or links for station-service transformers 7.11 Secondary wiring |
42 | 8. Miscellaneous accessories |
44 | Annex A (normative) Cable bus A.1 General A.2 References A.3 Definitions A.4 Service conditions A.5 Ratings A.6 Tests |
46 | A.7 Construction |
49 | Annex B (informative) Guide for calculating losses in isolated-phase bus B.1 General B.2 Conductor losses |
51 | B.3 Skin effects |
55 | B.4 Enclosure losses |
62 | B.5 Power consumption of cooling equipment B.6 Sample solutions |
70 | B.7 Structural steel losses |
71 | Annex C (informative) Application guide for ME bus in unusual service conditions C.1 General C.2 Ambient air temperature above 40 Ā°C C.3 Ambient air temperature below ā30 Ā°C C.4 Application at unusual altitudes |
72 | C.5 Other conditions that may affect design and application |
73 | C.6 Modification of equipment for unusual environment |
75 | Annex D (informative) Guide for handling, storage, and installation D.1 General D.2 Handling |
77 | D.3 Pre-operation check |
78 | Annex E (informative) Bibliography |