IEEE C37.30.3 2018
$28.71
IEEE Standard Requirements for High-Voltage Interrupter Switches, Interrupters, or Interrupting Aids Used on or Attached to Switches Rated for Alternating Currents Above 1000 V
Published By | Publication Date | Number of Pages |
IEEE | 2018 | 30 |
New IEEE Standard – Active. Requirements for interrupter switches, interrupters or interrupting aids used on or attached to switches rated for high-voltage ac above 1000 V and used indoors, outdoors, or in enclosures for non-fault current interrupting for which an interrupting duty is assigned are covered in this standard. It includes preferred ratings, construction, application, loading, installation, and operation and maintenance guidelines. This standard does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, metal enclosed switchgear, pad-mounted switchgear, reclosers, sectionalizers or otherre switching devices that are covered by otherre IEEE standards.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.30.3™-2018 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
9 | Introduction |
10 | Contents |
12 | 1. Overview 1.1 Scope 1.2 Purpose 2. Normative references |
13 | 3. Definitions |
14 | 4. Normal (usual) and special (unusual) service conditions 4.1 General 4.2 Normal (usual) service conditions |
15 | 4.3 Special (unusual) service conditions 5. Ratings 5.1 Ratings |
16 | 5.2 Rated maximum voltage (V) or (Ur) |
17 | 5.3 Rated insulation level (Ud), (Up) 5.4 Rated power-frequency (fr) 5.5 Rated continuous (normal) current (Ir) |
19 | 5.6 Rated short-time withstand current (Ik) 5.7 Rated peak withstand current (Ip) |
20 | 5.8 Rated short-time (symmetrical) withstand current duration (tk) 5.9 Rated supply voltage of closing and opening devices and of auxiliary and control circuits (Ua) 5.10 Rated supply frequency of closing and opening devices and of auxiliary circuits 5.11 Rated pressure of compressed gas supply for insulation and/or operation 5.12 Rated filling levels for insulation and/or operation 5.13 Rated switching duties |
22 | 5.14 Visible corona-free voltage 5.15 Radio influence voltage limit 5.16 Rated ice breaking ability 5.17 Rated mechanical endurance 5.18 Rated mechanical terminal load 5.19 Rated closing time (for power operated switches) 5.20 Rated operating duty cycles |
23 | 5.21 Rated fault-making current |
24 | 5.22 Capacitance switching transient overvoltage ratio 5.23 Rated differential capacitance voltage range 6. Design and construction 6.1 General 6.2 Requirements for liquids in switches 6.3 Requirements for gases in switches 6.4 Grounding provisions 6.5 Auxiliary and control equipment |
25 | 6.6 Dependent power operation 6.7 Stored energy operation 6.8 Independent manual operation 6.9 Operation of releases 6.10 Low- and high-pressure interlocking and monitoring devices 6.11 Nameplate markings 6.12 Interlocking devices 6.13 Position indicator 6.14 Degrees of protection by enclosures 6.15 Creepage distances for outdoor insulators 6.16 Gas and vacuum tightness |
26 | 7. Design (type) tests 7.1 Design (type) tests 7.2 Electromagnetic compatibility tests 7.3 Additional tests on auxiliary and control circuits 7.4 X-Radiation procedure for vacuum interrupters 8. Production tests (routine tests) 8.1 General 8.2 Dielectric withstand test; one minute dry power-frequency |
27 | 8.3 Dielectric test on auxiliary and control circuits 8.4 Measurement of the resistance of the main circuit 8.5 Tightness Tests 8.6 Design and visual checks |
28 | Annex A (informative) Bibliography |
30 | Back cover |