IEEE C37.60 2003
$82.92
(Replaced) IEEE Standard Requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV
Published By | Publication Date | Number of Pages |
IEEE | 2003 | 71 |
Revision Standard – Inactive – Superseded. IEEE Std C37.60-2003, IEEE Standard for Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for Alternating Current Systems Up to 38 kV
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | IEEE Standard for Overhead, Pad-Mounted, Dry Vault… |
4 | Introduction |
5 | Participants Contents |
7 | 1. Scope |
11 | 2. References |
12 | 3. Definitions |
13 | 4. Service conditions 4.1 Usual service conditions 4.2 Unusual service conditions |
14 | 5. Rating 5.1 Rating information 5.2 Rated maximum voltage |
15 | 5.3 Rated power-frequency |
16 | 5.4 Rated continuous current 5.5 Rated minimum tripping current… |
17 | 5.6 Rated symmetrical interrupting current |
18 | 5.7 Rated symmetrical making current 5.8 Rated lightning impulse withstand voltage 5.9 Rated control voltage and ranges |
19 | 5.10 Rated line and cable charging interrupting currents (where applicable) |
24 | 6. Design tests (type tests) 6.1 General |
25 | 6.2 Insulation (dielectric) tests |
27 | 6.3 Switching tests 6.4 Making current capability |
30 | 6.5 Rated symmetrical interrupting current tests |
41 | 6.6 Minimum tripping current tests |
42 | 6.7 Partial discharge (corona) tests |
43 | 6.8 Radio influence voltage tests (RIV) 6.9 Surge current test; series-trip reclosers/FIs |
45 | 6.10 Temperature rise test |
47 | 6.11 Time-current tests |
48 | 6.12 Mechanical duty test 6.13 Control electronic elements surge withstand capability (SWC) tests |
50 | 6.14 Condition of recloser/FI after each test of… |
51 | 7. Production tests (routine tests) |
52 | 7.1 Reclosing and overcurrent trip calibration 7.2 Control, secondary wiring, and accessory devices check tests 7.3 Dielectric withstand test; 1-min. dry power-frequency 7.4 Partial discharge test 7.5 Mechanical operations tests |
53 | 7.6 Water leak test 8. Field tests on units in service, including dc… |
54 | 9. Construction requirements 9.1 Tank construction: submersible or dry vault reclosers/FIs 9.2 Grounding provisions |
55 | 9.3 Insulating medium quantity indicators 9.4 Oil sampling provision (submersible reclosers/FIs) 9.5 Manual operating provision 9.6 Position indicator 9.7 Nameplate markings |
56 | 9.8 Stored energy mechanism charge indicator 9.9 Enclosure integrity 9.10 Counters 9.11 Conductor terminal sizes 9.12 Tank construction-pressurized reclosers/FIs only |
57 | Annex A (informative) X/R Ratios A.1 Time constant (tau cc) and X/R ratio A.2 Asymmetrical fault current Annex B (informative) |
59 | Simulated surge arrester operation tests |
62 | Annex C (normative) Method of drawing the envelope of the prospective transient recovery C.1 Introduction C.2 Drawing the envelope |
63 | C.3 Determination of parameters |
64 | Annex D (informative) Background basis of recloser TRV values |
66 | D.1 Uc=The TRV peak D.2 RRRV=The rate of rise of recovery voltage D.3 t3=The time to reach Uc at the specified RRRV |
67 | D.4 Multipliers for TRV values at currents less than |
68 | Annex E (informative) Altitude correction factors E.1 Introduction E.2 Altitude correction factors |
70 | E.3 Examples for switchgear with… E.4 Examples for switchgear ratings based on… |
71 | Annex F (informative) Bibliography |