IEEE C37.60 2003

$82.92

(Replaced) IEEE Standard Requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV

Published By Publication Date Number of Pages
IEEE 2003 71
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Inactive – Superseded. IEEE Std C37.60-2003, IEEE Standard for Overhead, Pad-Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for Alternating Current Systems Up to 38 kV

PDF Catalog

PDF Pages PDF Title
1 Cover
2 IEEE Standard for Overhead, Pad-Mounted, Dry Vault…
4 Introduction
5 Participants
Contents
7 1. Scope
11 2. References
12 3. Definitions
13 4. Service conditions
4.1 Usual service conditions
4.2 Unusual service conditions
14 5. Rating
5.1 Rating information
5.2 Rated maximum voltage
15 5.3 Rated power-frequency
16 5.4 Rated continuous current
5.5 Rated minimum tripping current…
17 5.6 Rated symmetrical interrupting current
18 5.7 Rated symmetrical making current
5.8 Rated lightning impulse withstand voltage
5.9 Rated control voltage and ranges
19 5.10 Rated line and cable charging interrupting currents (where applicable)
24 6. Design tests (type tests)
6.1 General
25 6.2 Insulation (dielectric) tests
27 6.3 Switching tests
6.4 Making current capability
30 6.5 Rated symmetrical interrupting current tests
41 6.6 Minimum tripping current tests
42 6.7 Partial discharge (corona) tests
43 6.8 Radio influence voltage tests (RIV)
6.9 Surge current test; series-trip reclosers/FIs
45 6.10 Temperature rise test
47 6.11 Time-current tests
48 6.12 Mechanical duty test
6.13 Control electronic elements surge withstand capability (SWC) tests
50 6.14 Condition of recloser/FI after each test of…
51 7. Production tests (routine tests)
52 7.1 Reclosing and overcurrent trip calibration
7.2 Control, secondary wiring, and accessory devices check tests
7.3 Dielectric withstand test; 1-min. dry power-frequency
7.4 Partial discharge test
7.5 Mechanical operations tests
53 7.6 Water leak test
8. Field tests on units in service, including dc…
54 9. Construction requirements
9.1 Tank construction: submersible or dry vault reclosers/FIs
9.2 Grounding provisions
55 9.3 Insulating medium quantity indicators
9.4 Oil sampling provision (submersible reclosers/FIs)
9.5 Manual operating provision
9.6 Position indicator
9.7 Nameplate markings
56 9.8 Stored energy mechanism charge indicator
9.9 Enclosure integrity
9.10 Counters
9.11 Conductor terminal sizes
9.12 Tank construction-pressurized reclosers/FIs only
57 Annex A (informative)
X/R Ratios
A.1 Time constant (tau cc) and X/R ratio
A.2 Asymmetrical fault current
Annex B (informative)
59 Simulated surge arrester operation tests
62 Annex C (normative)
Method of drawing the envelope of the prospective transient recovery
C.1 Introduction
C.2 Drawing the envelope
63 C.3 Determination of parameters
64 Annex D (informative)
Background basis of recloser TRV values
66 D.1 Uc=The TRV peak
D.2 RRRV=The rate of rise of recovery voltage
D.3 t3=The time to reach Uc at the specified RRRV
67 D.4 Multipliers for TRV values at currents less than
68 Annex E (informative)
Altitude correction factors
E.1 Introduction
E.2 Altitude correction factors
70 E.3 Examples for switchgear with…
E.4 Examples for switchgear ratings based on…
71 Annex F (informative)
Bibliography