IEEE C57.100 2012
$37.38
IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers
Published By | Publication Date | Number of Pages |
IEEE | 2012 | 37 |
Revision Standard – Active. A test procedure to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid-immersed transformers is provided. The test procedures are intended to provide data for the selection of a limiting hottest-spot temperature for rating purposes, provide data which may serve as the basis for a guide for loading, and permit the comparative evaluation of a proposed insulation system with reference to a system that has proven to be acceptable in service.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C57.100-2011 Front Cover |
6 | Introduction |
7 | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Interpretations Patents |
8 | Participants |
10 | Contents |
12 | Important Notice 1. Overview 1.1 Scope 1.2 Purpose |
13 | 2. Normative references 3. Definitions 3.1 Industry-proven insulation system |
14 | 4. Aging influences 5. Minimum life expectancy |
15 | 6. Criteria for end of life—Distribution transformer and power transformer model 7. Test temperatures |
16 | 8. Test methods and specimens 8.1 Distribution transformer 8.2 Power transformer model |
17 | 8.3 Relative testing specimens 9. Test period 9.1 Hottest spot test temperature 9.2 Temperature of liquid |
18 | 9.3 Duration of test period 9.4 Cycling 9.5 Calculation of aging caused by heating and cooling |
19 | 10. End-point tests 10.1 Distribution transformers 10.2 Power transformers 10.3 Abnormalities 11. Test results |
20 | 11.1 Data presentation 11.2 Test report |
21 | 11.3 Example calculation of life equation |
22 | 12. Applicability of test results |
24 | Annex A (normative) Materials testing for aging of liquid-immersed transformer insulation A.1 Purpose A.2 Test temperatures and test periods A.2.1 Single-point sealed tube aging |
25 | A.2.2 Three-point aging |
26 | A.3 Limiting factor—insulation system A.4 Comparative evaluation A.4.1 Single point aging |
27 | A.4.2 Three-point aging A.4.2.1 Determination of end-of-life criteria for candidate system In this particular example, the end-of-life criteria is 21.9% retained tensile strength, which is the average of the results shown in Table A.2. A.4.2.1.1 Test program for the candidate system A.4.2.1.2 Determination of time-temperature points |
29 | A.4.2.1.3 Determination of the life equation |
30 | Annex B (normative) Materials testing—standard test procedure for sealed tube aging of liquid-immersed transformer insulation B.1 Test samples |
31 | Annex C (normative) Materials testing—standard test procedure for dual-temperature sealed tube aging of liquid-immersed transformer insulation C.1 Purpose C.2 Test samples |
33 | Annex D (informative) Historical background information D.1 Distribution transformer and power transformer model test result discussion from IEEE Std C57.100-1999 [B12] D.2 Background discussion from references |
36 | Annex E (informative) Bibliography |