Revision Standard – Active. Information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, and load losses of power and distribution transformers are provided. The guide is intended as a complement to the test code procedures given in Clause 8 and Clause 9 of IEEE Std C57.12.90.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C57.123-2010 front cover
3 Title page
6 Introduction
Notice to users
Laws and regulations
Copyrights
Updating of IEEE documents
7 Errata
Interpretations
Patents
Acknowledgments
8 Participants
10 Contents
11 Important Notice
1. Overview
1.1 Scope
12 1.2 Purpose
2. Normative references
3. Transformer no-load losses
3.1 General
13 3.2 Parameters affecting magnitude of no-load losses
3.2.1 Induction
3.2.2 Excitation voltage magnitude
3.2.3 Excitation voltage waveform
15 3.2.4 Core configuration
3.2.5 Core material
3.2.6 Joint type
16 3.2.7 Core size
3.2.8 Frequency
3.2.9 Workmanship
3.2.10 Core temperature
3.2.11 Impulse tests
17 3.2.12 Core stabilization
3.2.13 Short-circuit testing
3.3 Excitation current (no-load current)
18 3.4 Test requirements
19 3.5 Measurement of no-load losses
3.5.1 Measuring circuit
3.5.2 Waveform correction
21 3.5.3 Impact of a high source impedance
23 3.6 Measurement of excitation current
24 3.7 Measuring circuitry for three-phase transformers
3.7.1 Three-wattmeter connections
25 3.7.2 Two-wattmeter method (not recommended)
3.7.3 Voltmeter connections
28 4. Transformer load losses
4.1 General
29 4.2 Measuring circuitry
4.3 Load-loss measurement uncertainties
31 4.4 Corrections to measured load losses
4.4.1 Phase-angle correction of a conventional load-loss measuring system
34 4.4.2 Magnitude correction
4.4.3 Correction for losses due to the shorting connection
37 4.4.4 Special precautions
39 4.5 Measuring circuitry for three-phase transformers
4.5.1 Three-wattmeter method
40 4.5.2 Two-wattmeter method (not recommended)
4.5.3 Test of three-phase transformer with single-phase voltage
41 4.5.4 Bridge method
42 5. Advanced measuring systems
5.1 Enhanced conventional system
5.2 Advanced voltage and current transducers
43 6. Specified tolerances on losses
6.1 Specified tolerances on no-load losses
44 6.2 Specified tolerances on total losses
45 7. Traceability and calibration
46 8. Grounding, shielding, and safety
8.1 Grounding
8.2 Shielding
47 8.3 Safety
48 Annex A (informative) Bibliography
IEEE C57.123 2010