IEEE C57.13.5-2003
$50.92
IEEE Standard of Performance and Test Requirements of Instrument Transformers of a Nominal Voltage of 115 kV and Above
Published By | Publication Date | Number of Pages |
IEEE | 2003 | 53 |
New IEEE Standard – Superseded. This standard covers the test requirements, including test sequences, criteria, methods, and documentation for instrument transformers of 115 kV nominal system and above. It is to be used a supplement to IEEE STD C57.13-1993. Besides the provision of up-to-date test requirements, the trial-use standard also provides test procedures that were not adequately covered in the previous standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Title Page |
4 | Introduction Participants |
6 | CONTENTS |
8 | 1. Overview 1.2 Purpose 2. References |
10 | 3. Definitions 4. General 4.1 Insulation requirements |
14 | 4.2 Mineral oil requirements 4.3 Requirements for accuracy and accuracy calibration systems |
15 | 4.4 Mechanical performance requirements |
16 | 4.5 Thermal performance requirements 4.6 Ground shield requirements 4.7 Dissolved gas and water content requirements for new oil-immersed 4.8 Endurance capability for fast high-voltage transient |
17 | 4.9 Performance of internal arc protection 4.10 Identification of test sample in the type test report 4.11 Secondary short-circuit capability for voltage transformers 5. Test conditions |
18 | 6. Classification of tests 6.1 Routine tests and test sequences |
20 | 6.2 Type tests and test sequences |
21 | 6.3 Special tests |
24 | 7. Routine test procedures (applicable to instrument transformers) 7.1 Verification of terminal markings and polarity 7.2 Capacitance and dissipation factor test 7.3 Applied voltage test on secondary windings |
25 | 7.4 Insulation resistance test on windings 7.5 Lightning impulse voltage test on the primary winding 7.6 Power frequency voltage withstand test |
26 | 7.7 Partial discharge test 7.8 Dissolved gas and water content analysis for oil-immersed transformers (of a nominal system voltage 345 kV and above 7.9 Sealing test |
27 | 7.10 Ground shield check |
28 | 7.11 Tests on the mineral oil 8. Routine test procedures (applicable to current transformers) 8.1 Inter-turn overvoltage test |
29 | 8.2 Accuracy test for the metering rated current transformers 8.3 Resistance measurement of relaying rated secondary windings 8.4 Performance characteristics of relaying rated current transformers |
30 | 9. Routine test procedures (applicable to voltage transformers) 9.1 Applied voltage test on the neutral terminal 9.2 Accuracy test |
31 | 9.3 Excitation characteristics with respect to rated voltage factor 9.4 Resistance measurement of windings 10. Type test procedures (applicable to instrument transformers) 10.1 Dissolved gas and water content analysis |
32 | 10.2 Mechanical test 10.3 Lightning impulse voltage test on the primary winding |
33 | 10.4 Switching impulse voltage test on the primary windingāwet 10.5 External RIV test |
34 | 10.6 Power frequency voltage withstand testāwet 10.7 Power frequency voltage withstand/partial discharge testādry 10.8 Temperature rise test |
36 | 10.9 Short-time mechanical and thermal rating test |
39 | 11. Type test procedure (applicable to current transformers) 11.1 Secondary open-circuit voltage withstand test 12. Special test procedures 12.1 Endurance chopped-wave test |
40 | 12.2 Internal arc test |
41 | 12.3 Seismic qualification 13. Identification of test sample in the type test report 13.1 Document package related to transformer type |
43 | Annex A (normative) Test code |
47 | Annex B (informative) Dielectric test performed at an altitude of 1000 m or less for instrument transformers designed for installation at altitudes greater than 1000 m |
48 | Annex C (informative) Dielectric tests, oil sampling, and other related measurments in the field |
49 | Annex D (informative) Internal arc protection for instrument transformers |
50 | Annex E (normative) Validity of test reports and guidance for reviewing the design comparison report for the modified design |
52 | Annex F (normative) Rated voltage factor |
53 | Annex G (informative) Bibliography |