American National Standard Performance Specifications for Instrumentation Systems Designed for Measuring Radon Progeny in Air
Published By | Publication Date | Number of Pages |
IEEE | 2022 |
New IEEE Standard – Active – Draft. Minimum performance requirements and performance testing requirements are specified in this standard for instruments designed to measure radon progeny in air. Inasmuch as the health effects of exposure to radon progeny, and hence regulatory control, are quantified relative to the ultimate dose delivered by the complete decay of all the radon progeny in the monitored air, the principle measurand of interest is therefore the potential alpha energy concentration, expressed in units of either working level (WL) or joules m-3 given that primary measurements characterize activity. The needs of users, manufacturers, and regulators concerned with radon progeny measurements are addressed in this standard.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI N42.50-2022 Front cover |
2 | Title page |
5 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
9 | Participants |
11 | Introduction |
12 | Contents |
13 | 1. Overview 1.1 Scope |
14 | 1.2 Word usage 2. Normative references |
16 | 3. Definitions |
18 | 4. Units and conversions 5. Classification of instrument systems 6. Performance and testing 6.1 Attached and unattached fraction |
19 | 6.2 Radiation response to radon progeny |
20 | 6.3 Sampling system design |
24 | 6.4 Electronic criteria |
27 | 6.5 Interfering responses |
28 | 6.6 Mechanical criteria |
29 | 6.7 Environmental criteria |
30 | 6.8 Calibration and maintenance |
33 | 7. Class-specific performance and testing criteria 7.1 Grab sampling instruments 7.2 Continuously sampling instruments |
35 | 7.3 Integrating sampling instruments 8. Documentation 8.1 Type test report 8.2 Certificate |
36 | 8.3 Manuals and procedures |
37 | 8.4 Records |
38 | Annex A (informative) Bibliography |
39 | Annex B (normative) Radon and radon progeny equilibrium B.1 General B.2 WL and EEC |
40 | Annex C (informative) Aerosol sampling considerations C.1 Aerosol sampling considerations |
41 | Annex D (informative) Filter Selection D.1 Filter selection |
42 | Annex E (informative) Radon decay chain |
44 | Annex F (informative) Life-cycle approach to instrument tests and test requirements |
47 | Annex G (informative) Other considerations of radiation response G.1 Radiation response—radon progeny as interfering radionuclides |
50 | Back cover |