Shopping Cart

No products in the cart.

IL ChicagoEnergyConservationCode 2019

$29.25

Chicago Energy Conservation Code, Title 14N – with May 2020 Supplement

Published By Publication Date Number of Pages
IL 2019 180
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The Chicago Energy Conservation Code, Title 14N regulates matters related to the design, construction, and rehabilitation of new and existing buildings for energy efficiency. This code has been drafted to be consistent with the 2019 Illinois amendments to the International Energy Conservation Code. This is a fully integrated codes based on the 2018 IECC. Effective June 1, 2019

PDF Catalog

PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO ENERGY CONSERVATION CODE TITLE 14N
2 COPYRIGHT
3 CITY OF CHICAGO OFFICE OF THE MAYOR MAYOR’S MESSAGE
4 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
5 ABOUT THE CHICAGO CONSTRUCTION CODES
9 ACKNOWLEDGMENTS
17 PREFACE TO THE MODEL CODE
21 EFFECTIVE USE OF THE CHICAGO ENERGY CONSERVATION CODE
25 TABLE OF CONTENTS
27 TABLE OF SUPPLEMENTED PROVISIONS
29 CECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
31 CHAPTER C1 SCOPE AND PURPOSE
SECTION C101 GENERAL
33 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
39 MAY 2020 SUPPLEMENT TO CHAPTER 2 [CE] DEFINITIONS
40 SECTION C202 GENERAL DEFINITIONS
42 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
44 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
45 EQUATION 4-1
EQUATION 4-2
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
46 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
48 TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
49 EQUATION 4-5
51 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
52 SECTION C403 BUILDING MECHANICAL SYSTEMS
53 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
54 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
55 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
56 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
57 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
58 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
59 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
60 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
61 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
62 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
63 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
66 TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
67 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
71 TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
72 TABLE C403.8.1(1) FAN POWER LIMITATION
73 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
74 TABLE C403.8.5.1 COOLING SYSTEMS
75 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
76 TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
77 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
79 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
80 EQUATION 4-8
81 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)
SECTION C404 SERVICE WATER HEATING (MANDATORY)
82 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
83 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
84 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
85 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
87 EQUATION 4-9
89 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
90 FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
EQUATION 4-10
91 EQUATION 4-11
92 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
93 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
94 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
95 TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
96 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
97 TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
98 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
99 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
100 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
101 SECTION C407 TOTAL BUILDING PERFORMANCE
103 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
104 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
105 TABLE C407.5.1(2) HVAC SYSTEMS MAP
106 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
107 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
108 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
111 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
112 MAY 2020 SUPPLEMENT TO CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
113 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
114 TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
115 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
117 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
118 SECTION C503 ALTERATIONS
119 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
121 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
122 AMCA
ANSI
APSP
ASHRAE
123 ASTM
CSA
124 CTI
DASMA
DOE
IEEE
IES
125 ISO
NEMA
NFRC
SMACNA
UL
US-FTC
126 WDMA
127 INDEX
137 CECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
139 CHAPTER 1 [RE] SCOPE AND PURPOSE
SECTION R101 GENERAL
141 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
145 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
146 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
147 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
148 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE R402.1.4 EQUIVALENT U-FACTORSa
149 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
152 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
153 SECTION R403 SYSTEMS
155 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
TABLE R403.6.4.3(1) CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS
TABLE R403.6.4 INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa
156 EQUATION 4-1
TABLE R403.6.4.4 MINIMUM REQUIRED LOCAL EXHAUST RATE FOR DWELLING UNITS IN GROUP R-5 OCCUPANCIES
157 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
158 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
159 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
160 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
161 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
162 EQUATION 4-2
TABLE R406.4 MAXIMUM ENERGY RATING INDEX
163 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
164 SECTION R503 ALTERATIONS
165 SECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE
167 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
AMCA
APSP
ASHRAE
168 ASTM
CSA
DASMA
HVI
ICC
169 IEEE
NFRC
RESNET
UL
US-FTC
170 WDMA
171 INDEX
177 ICC EVALUATION SERVICE
178 ICC MEMBERSHIP
179 ICC ASSESSMENT CENTER
180 ICC DIGITAL CODES LIBRARY
IL ChicagoEnergyConservationCode 2019
$29.25