JIS C 8159-1:2013
$34.45
Non-integrated linear LED lamps with GX16t-5 cap for general lighting services-Part 1: Safety specifications
Published By | Publication Date | Number of Pages |
JIS | 2013-04-22 | 41 |
This Standard specifies the safety requirements of non-integrated linear LED lamps with GX16t-5 cap for general lighting services (hereafter referred to as "linear LED lamp").
This Standard is applicable to the following linear LED lamps:
— Rated wattage: 60 W or less
— Lamp voltage: 120 V ripple free d.c. or less
Cap: GX16t-5
This Standard is not applicable to linear LED lamps that use the conventional caps for a fluorescent lamp and integrate a control gear.
The linear LED lamps covered by this Standard are applicable to Class I luminaire and Class II luminaire which are the insulating classes of luminaire defined in JIS C 8105-1.
NOTE 1 The information for the design of control gear of linear LED lamp targeted in this Standard is given in Annex E, the information for the design of a lamp socket in Annex F, and the information for the design of a lamp luminaire in Annex G.
Furthermore, the relation between the positioning of a linear LED lamp and that of other LED modules, LED lamps, etc. is described in Annex H.
NOTE 2 "120 V ripple free d.c." means a DC system of 120 V DC of maximum peak voltage 140 V or less based on the definition of the sine wave ripple component of not more than 10 % (effective value).