KY KBC 2013
$35.75
Kentucky Building Code, Second Edition, February 2014
Published By | Publication Date | Number of Pages |
KY | 2013 | 98 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
2 | Kentucky Information on Code Enforcement |
3 | SAMPLE ORDINANCE |
5 | ACKNOWLEDGEMENTS |
9 | CHAPTER 1 – SCOPE AND ADMINISTRATION SECTION 101 GENERAL |
10 | SECTION 102 APPLICABILITY SECTION 103 DEPARTMENT OF HOUSING, BUILDINGS AND CONSTRUCTION SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
12 | SECTION 105 PERMITS |
13 | SECTION 107 SUBMITTAL DOCUMENTS |
14 | SECTION 108 TEMPORARY STRUCTURES AND USES SECTION 109 FEES SECTION 110 INSPECTIONS |
15 | SECTION 111 CERTIFICATE OF OCCUPANCY SECTION 112 SERVICE UTILITIES SECTION 113 BOARD OF APPEALS |
16 | SECTION 114 VIOLATIONS |
17 | SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT SECTION 117CABINET FOR HEALTH AND FAMILY SERVICES (CHFS) REGULATED BUILDINGS SECTION 118 PROOF OF INSURANCE SECTION 119 POSTING STRUCTURES SECTION 120 EFFECTIVE DATES SECTION 121 PLAN REVIEW AND INSPECTION FEES FOR THE DEPARPMENT OF HOUSING, BUILDINGS AND CONSTRUCTION |
19 | SECTION 122 LICENSED DESIGN PROFESSIONALS |
21 | CHAPTER 2 – DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
25 | CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION SECTION 303 ASSEMBLY GROUP A SECTION 304 BUSINESS GROUP B |
26 | SECTION 305 EDUCATIONAL GROUP E SECTION 307 HIGH-HAZARD GROUP H SECTION 308 INSTITUTIONAL GROUP I SECTION 310 RESIDENTIAL GROUP R |
28 | CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USEAND OCCUPANCY SECTION 405 UNDERGROUND BUILDINGS SECTION 407 Groups I-1 and I-2 SECTION 408 GROUP I-3 |
29 | SECTION 425 DAY CARE CENTERS |
32 | SECTION 426 BED AND BREAKFAST ESTABLISHMENTS SECTION 428 BARRELED SPIRIT STORAGE BUILDINGS |
34 | SECTION 429 CONSUMER FIREWORKS RETAIL SALES FACILITIES SECTION 430 TEMPORARY STRUCTURES |
41 | CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS SECTION 506 BUILDING AREA MODIFICATIONS SECTION 507 UNLIMITED AREA BUILDINGS SECTION 510 SPECIAL PROVISIONS |
42 | CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES SECTION 703 FIRE-RESISTANCE RATINGSAND FIRE TESTS SECTION 706 FIRE WALLS SECTION 718 CONCEALED SPACES |
43 | CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
45 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE EXTINGUISING SYSTEMS SECTION 905 STANDPIPE SYSTEMS SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
47 | SECTION 909 SMOKE CONTROL SYSTEMS |
48 | SECTION 910 SMOKE AND HEAT REMOVAL SECTION 912 FIRE DEPARTMENT CONNECTIONS SECTION 913 FIRE PUMPS SECTION 916 YARD HYDRANTS |
49 | CHAPTER 10 – MEANS OF EGRESS SECTION 1004 OCCUPANT LOAD |
50 | SECTION 1006 MEANS OF EGRESS ILLUMINATION SECTION 1008 DOORS, GATES AND TURNSTILES |
51 | SECTION 1010 RAMPS SECTION 1012 HANDRAILS |
52 | SECTION 1013GUARDS |
53 | SECTION 1016 EXIT ACCESS AND TRAVEL DISTANCE |
54 | SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS SECTION 1027EXIT DISCHARGE SECTION 1028 ASSEMBLY |
55 | SECTION 1029 EMERGENCY ESCAPE AND RESCUE |
56 | CHAPTER 11 ACCESSIBILITY SECTION 1104 ACCESSIBLE ROUTE SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES |
57 | SECTION 1109 OTHER FEATURES AND FACIILTIES |
58 | CHAPTER 12 INTERNAL ENVIRONMENT SECTION 1203 VENTILATION SECTION 1206 YARDS OR COURTS SECTION 1209 ACCESS TO UNOCCUPIED SPACES SECTION 1210 TOILET AND BATHROOM REQUIREMENTS |
59 | CHAPTER 14 EXTERIOR WALLS SECTION 1410 WINDOW CLEANING SAFEGUARDS |
60 | CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1503 WEATHER PROTECTION SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS |
61 | CHAPTER 16 – STRUCTURAL DESIGN SECTION 1601 GENERAL SECTION 1602 DEFINITIONS AND NOTATIONS SECTION 1603 CONSTRUCTION DOCUMENTS SECTION 1604 GENERAL DESIGN REQUIREMENTS SECTION 1605 LOAD COMBINATIONS SECTION 1607 LIVE LOADS |
62 | SECTION 1608 SNOW LOADS |
63 | SECTION 1609 WIND LOADS |
64 | SECTION 1611 RAIN LOADS |
66 | SECTION 1612 FLOOD LOADS SECTION 1613 EARTHQUAKE LOADS |
69 | SECTION 1614 ATMOSPHERIC ICE LOADS |
72 | CHAPTER 17 – SPECIAL INSPECTIONS AND TESTS SECTION 1704 SPECIAL INSPECTIONS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATIONS |
73 | SECTION 1705 REQUIRED VERIFICATION AND INSPECTION |
75 | SECTION 1709 IN-SITU LOAD TESTS SECTION 1710 PRECONSTRUCTION LOAD TESTS |
76 | CHAPTER 18 – SOILS AND FOUNDATIONS SECTION 1801GENERAL SECTION 1803 GEOTECHNICAL INVESTIGATIONS SECTION 1804 EXCAVATION, GRADING AND FILL SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES SECTION 1809 SHALLOW FOUNDATIONS |
77 | SECTION 1810 DEEP FOUNDATIONS |
79 | CHAPTER 19 – CONCRETE SECTION 1910 SHOTCRETE |
80 | CHAPTER 21 – MASONRY SECTION 2113 MASONRY CHIMNEYS |
81 | CHAPTER 22 – STEEL SECTION 2207 STEEL JOISTS SECTION 2209 STEEL STORAGE RACKS SECTION 2211 COLD-FRAMED STEEL LIGHT-FRAME CONSTRUCTION |
82 | CHAPTER 23 – WOOD SECTION 2303 MINIMUM STANDARDS AND QUALITY SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION |
84 | CHAPTER 24 – GLASS AND GLAZING SECTION 2403 GENERAL REQUIREMENTS FOR GLASS SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS |
85 | CHAPTER 27 – ELECTRICAL SECTION 2701 GENERAL SECTION 270 2EMERGENCY AND STANDBY POWER SYSTEMS SECTION 2703 PERMIT AND CERTIFICATE OF INSPECTION SECTION 2704 INSPECTIONS AND TESTS |
86 | CHAPTER 28 – MECHANICAL SYSTEMS SECTION 2801 GENERAL |
87 | CHAPTER 29 PLUMBING SYSTEMS SECTION 2901 GENERAL SECTION 2902 MINIMUM PLUMBING FACILITIES |
88 | CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS SECTION 3001 GENERAL SECTION 3009 POWER ELEVATOR OPERATION SECTION 3010 STAIRWAY CHAIR-LIFTS AND WHEELCHAIR LIFTS SECTION 3011 MAINTENANCE AND ACCIDENTS |
89 | SECTION 3012 CONSTRUCTION DOCUMENTS AND PERMITS SECTION 3013 CERTIFICATE OF COMPLIANCE |
90 | CHAPTER 31 SPECIAL CONSTRUCTION SECTION 3103 TEMPORARY STRUCTURES SECTION 3107 SIGNS SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS SECTION 3109 SWIMMING POOLS |
95 | CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION SECTION 3305 SANITARY |
96 | CHAPTER 34 EXISTING STRUCTURES SECTION 3401 GENERAL SECTION 3403 ADDITIONS SECTION 3409 HISTORIC BUILDINGS SECTION 3412 COMPLIANCE ALTERNATIVES |
97 | CHAPTER 35 REFERENCED STANDARDS |