MI MechanicalCode 09 2009
$41.98
Michigan Mechanical Code
Published By | Publication Date | Number of Pages |
MI | 2009 | 147 |
This is a fully integrated custom code based on the 2009 International Mechanical Code®(IMC®). Establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2009 MICHIGAN MECHANICAL CODE |
3 | INTRODUCTION |
4 | COPYRIGHT |
5 | PREFACE |
7 | SAMPLE ORDINANCE |
9 | TABLE OF CONTENTS |
13 | CHAPTER 1 – SCOPE AND ADMINISTRATION PART I—SCOPE AND APPLICATION SECTION 101 – GENERAL SECTION 102 – APPLICABILITY |
14 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 – DEPARTMENT OF MECHANICAL INSPECTION SECTION 104 – DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 – APPROVAL |
15 | SECTION 106 – PERMITS |
17 | SECTION 107 – INSPECTIONS AND TESTING |
18 | SECTION 108 – VIOLATIONS |
19 | SECTION 109 – MEANS OF APPEAL SECTION 110 – TEMPORARY EQUIPMENT, SYSTEMS AND USES |
21 | CHAPTER 2 – DEFINITIONS SECTION 201 – GENERAL SECTION 202 – GENERAL DEFINITIONS |
33 | CHAPTER 3 – GENERAL REGULATIONS SECTION 301 – GENERAL |
34 | SECTION 302 – PROTECTION OF STRUCTURE |
35 | SECTION 303 – EQUIPMENT AND APPLIANCE LOCATION SECTION 304 – INSTALLATION |
37 | SECTION 305 – PIPING SUPPORT TABLE 305.4 – PIPING SUPPORT SPACING SECTION 306 – ACCESS AND SERVICE SPACE |
39 | SECTION 307 – CONDENSATE DISPOSAL TABLE 307.2.2 – CONDENSATE DRAIN SIZING |
40 | SECTION 308 – CLEARANCE REDUCTION SECTION 309 – TEMPERATURE CONTROL SECTION 310 – EXPLOSION CONTROL SECTION 311 – SMOKE AND HEAT VENTS |
41 | TABLE 308.6 – CLEARANCE REDUCTION METHODS SECTION 312 – HEATING AND COOLING LOAD CALCULATIONS |
43 | CHAPTER 4 – VENTILATION SECTION 401 – GENERAL TABLE 401.5 – OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS SECTION 402 – NATURAL VENTILATION |
44 | SECTION 403 – MECHANICAL VENTILATION EQUATION 4-1 |
45 | TABLE 403.3 – MINIMUM VENTILATION RATES |
46 | TABLE 403.3—continued MINIMUM VENTILATION RATES |
47 | TABLE 403.3—continued MINIMUM VENTILATION RATES |
48 | TABLE 403.3.1.2 – ZONE AIR DISTRIBUTION EFFECTIVENESS EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 EQUATION 4-5 TABLE 403.3.2.3.2 – SYSTEM VENTILATION EFFICIENCY EQUATION 4-6 EQUATION 4-7 |
49 | EQUATION 4-8 SECTION 404 – ENCLOSED PARKING GARAGES SECTION 405 – SYSTEMS CONTROL SECTION 406 – VENTILATION OF UNINHABITED SPACES |
51 | CHAPTER 5 – EXHAUST SYSTEMS SECTION 501 – GENERAL SECTION 502 – REQUIRED SYSTEMS |
52 | EQUATION 5-1 |
58 | SECTION 503 – MOTORS AND FANS SECTION 504 – CLOTHES DRYER EXHAUST |
59 | TABLE 504.6.4.1 – DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH SECTION 505 – DOMESTIC KITCHEN EXHAUST EQUIPMENT |
60 | SECTION 506 – COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
63 | SECTION 507 – COMMERCIAL KITCHEN HOODS |
65 | TABLE 507.11 – MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE |
66 | SECTION 508 – COMMERCIAL KITCHEN MAKEUP AIR SECTION 509 – FIRE SUPPRESSION SYSTEMS SECTION 510 – HAZARDOUS EXHAUST SYSTEMS |
68 | TABLE 510.8 – MINIMUM DUCT THICKNESS TABLE 510.8.2 – CLEARANCE TO COMBUSTIBLES SECTION 511 – DUST, STOCK AND REFUSE CONVEYING SYSTEMS |
69 | TABLE 511.2 – CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 512 – SUBSLAB SOIL EXHAUST SYSTEMS SECTION 513 – SMOKE CONTROL SYSTEMS |
71 | EQUATION 5-2 EQUATION 5-3 EQUATION 5-4 |
73 | SECTION 514 – ENERGY RECOVERY VENTILATION SYSTEMS |
75 | CHAPTER 6 – DUCT SYSTEMS SECTION 601 – GENERAL SECTION 602 – PLENUMS |
77 | SECTION 603 – DUCT CONSTRUCTION AND INSTALLATION TABLE 603.4 – DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS |
79 | SECTION 604 – INSULATION SECTION 605 – AIR FILTERS SECTION 606 – SMOKE DETECTION SYSTEMS CONTROL |
80 | SECTION 607 – DUCT AND TRANSFER OPENINGS |
81 | TABLE 607.3.2.1 – FIRE DAMPER RATING |
85 | CHAPTER 7 – COMBUSTION AIR SECTION 701 – GENERAL |
87 | CHAPTER 8 – CHIMNEYS AND VENTS SECTION 801 – GENERAL |
88 | SECTION 802 – VENTS TABLE 802.2 – VENT APPLICATION |
89 | SECTION 803 – CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FO RMEDIUM- AND HIGH-HEAT APPLIANCES |
90 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 – DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
91 | SECTION 805 – FACTORY-BUILT CHIMNEYS |
92 | SECTION 806 – METAL CHIMNEYS |
93 | CHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 – GENERAL SECTION 902 – MASONRY FIREPLACES SECTION 903 – FACTORY-BUILT FIREPL SECTION 904 – PELLET FUEL-BURNING APPLIANCES SECTION 905 – FIREPLACE STOVES AND ROOM HEATERS SECTION 906 – FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 – INCINERATORS AND CREMATORIES SECTION 908 – COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS |
94 | SECTION 909 – VENTED WALL FURNACES SECTION 910 – FLOOR FURNACES SECTION 911 – DUCT FURNACES SECTION 912 – INFRARED RADIANT HEATERS SECTION 913 – CLOTHES DRYERS |
95 | SECTION 914 – SAUNA HEATERS SECTION 915 – ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 – POOL AND SPA HEATERS SECTION 917 – COOKING APPLIANCES SECTION 918 – FORCED-AIR WARM-AIR FURNACES |
96 | SECTION 919 – CONVERSION BURNERS SECTION 920 – UNIT HEATERS |
97 | SECTION 921 – VENTED ROOM HEATERS SECTION 922 – KEROSENE AND OIL-FIRED STOVES SECTION 923 – SMALL CERAMIC KILNS SECTION 924 – STATIONARY FUEL CELL POWER SYSTEMS SECTION 925 – MASONRY HEATERS SECTION 926 – GASEOUS HYDROGEN SYSTEMS SECTION 927 – HEAT RECOVERY VENTILATORS SECTION 928 – SOLID FUEL HYDRONIC HEATERS |
99 | CHAPTER 10 – BOILERS,WATER HEATERS AND PRESSURE VESSELS SECTION 1001 – GENERAL SECTION 1002 – WATER HEATERS SECTION 1003 – PRESSURE VESSELS SECTION 1004 – BOILERS |
100 | SECTION 1005 – BOILER CONNECTIONS SECTION 1006 – SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS |
101 | SECTION 1007 – BOILER LOW-WATER CUTOFF SECTION 1008 – STEAM BLOWOFF VALVE SECTION 1009 – HOT WATER BOILER EXPANSION TANK EQUATION 10-1 SECTION 1010 – GAUGES |
103 | CHAPTER 11 – REFRIGERATION SECTION 1101 – GENERAL SECTION 1102 – SYSTEM REQUIREMENTS |
104 | SECTION 1103 – REFRIGERATION SYSTEM CLASSIFICATION SECTION 1104 – SYSTEM APPLICATION REQUIREMENTS |
105 | TABLE 1103.1 – REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
106 | TABLE 1103.1 – REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
107 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
108 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
109 | TABLE 1104.3.2 – MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS |
110 | SECTION 1105 – MACHINERY ROOM, GENERAL REQUIREMENTS EQUATION 11-1 |
111 | EQUATION 11-2 SECTION 1106 – MACHINERY ROOM, SPECIAL REQUIREMENTS SECTION 1107 – REFRIGERANT PIPING |
113 | SECTION 1108 – FIELD TEST SECTION 1109 – PERIODIC TESTING |
115 | CHAPTER 12 – HYDRONIC PIPING SECTION 1201 – GENERAL SECTION 1202 – MATERIAL TABLE 1202.4 – HYDRONIC PIPE TABLE 1202.4—continued HYDRONIC PIPE TABLE 1202.5 – HYDRONIC PIPE FITTINGS |
116 | SECTION 1203 – JOINTS AND CONNECTIONS |
117 | SECTION 1204 – PIPE INSULATION |
118 | SECTION 1205 – VALVES SECTION 1206 – PIPING INSTALLATION SECTION 1207 – TRANSFER FLUID SECTION 1208 – TESTS |
119 | SECTION 1209 – EMBEDDED PIPING |
121 | CHAPTER 13 – FUEL OIL PIPING AND STORAGE SECTION 1301 – GENERAL SECTION 1302 – MATERIAL TABLE 1302.3 – FUEL OIL PIPING SECTION 1303 – JOINTS AND CONNECTIONS |
122 | SECTION 1304 – PIPING SUPPORT SECTION 1305 – FUEL OIL SYSTEM INSTALLATION |
123 | SECTION 1306 – OIL GAUGING SECTION 1307 – FUEL OIL VALVES SECTION 1308 – TESTING |
125 | CHAPTER 14 – SOLAR SYSTEMS SECTION 1401 – GENERAL SECTION 1402 – INSTALLATION |
126 | SECTION 1403 – HEAT TRANSFER FLUIDS SECTION 1404 – MATERIALS |
127 | CHAPTER 15 – REFERENCED STANDARDS ACCA AHRI ANSI ASHRAE |
128 | ASME ASSE ASTM |
130 | AWS AWWA CSA DOL FS |
131 | ICC IIAR MSS NAIMA NFPA |
132 | SMACNA UL |
135 | CHAPTER 16 – AUTOMATIC SPRINKLER SYSTEMS; FIRE SUPPRESSION SYSTEMS SECTION 1600 – AUTOMATIC SPRINKLER SYSTEMS; FIRE SUPPRESSION SYSTEMS |
137 | APPENDIX A – COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 – ALL AIR FROM INSIDE THE BUILDING FIGURE A-2 – ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC |
138 | FIGURE A-3 – ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE A-4 – ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS |
139 | FIGURE A-5 – CHIMNEY CONNECTOR SYSTEMS |
140 | FIGURE A-5—continued CHIMNEY CONNECTOR SYSTEMS |
141 | INDEX |
146 | MEMBERSHIP BENEFITS |
147 | ICC ES PMG HELPFUL LINKS: |