MI MechanicalCode 2015
$51.46
Michigan Mechanical Code
Published By | Publication Date | Number of Pages |
MI | 2015 | 163 |
A fully integrated custom code based on the 2015 International Plumbing Code. Effective date: April 20, 2017
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2015 MICHIGAN MECHANICAL CODE |
2 | INSIDE OF FRONT COVER – INTRODUCTION |
3 | 2015 MICHIGAN MECHANICAL CODE INCORPORATING THE 2015 EDITION OF THE INTERNATIONAL MECHANICAL CODE® TITLE PAGE |
4 | COPYRIGHT |
5 | PREFACE |
9 | EFFECTIVE USE OF THE INTERNATIONAL MECHANICAL CODE |
13 | TABLE OF CONTENTS |
17 | CHAPTER 1 SCOPE AND ADMINISTRATION PART 1–SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
18 | PART 2–ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF MECHANICAL INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL |
19 | SECTION 105 APPROVAL SECTION 106 PERMITS |
21 | SECTION 107 INSPECTIONS AND TESTING |
22 | SECTION 108 VIOLATIONS |
23 | SECTION 109 MEANS OF APPEAL SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES |
25 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
37 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL |
38 | SECTION 302 PROTECTION OF STRUCTURE |
39 | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION SECTION 304 INSTALLATION |
41 | SECTION 305 PIPING SUPPORT TABLE 305.4 PIPING SUPPORT SPACINGa SECTION 306 ACCESS AND SERVICE SPACE |
43 | SECTION 307 CONDENSATE DISPOSAL TABLE 307.2.2 CONDENSATE DRAIN SIZING |
44 | SECTION 308 CLEARANCE REDUCTION |
45 | TABLE 308.4.2 CLEARANCE REDUCTION METHODSb SECTION 309 TEMPERATURE CONTROL SECTION 310 EXPLOSION CONTROL |
46 | SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS |
47 | CHAPTER 4 VENTILATION SECTION 401 GENERAL TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS SECTION 402 NATURAL VENTILATION |
48 | SECTION 403 MECHANICAL VENTILATION |
49 | EQUATION 4-1 TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 EQUATION 4-5 |
50 | TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY EQUATION 4-6 EQUATION 4-7 EQUATION 4-8 EQUATION 4-9 |
51 | TABLE 403.3.2.3 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR GROUP R-2, R-3, AND R-4 OCCUPANCIES SECTION 404 ENCLOSED PARKING GARAGES SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES |
52 | TABLE 403.3.1.1 MINIMUM VENTILATION RATES |
53 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES |
54 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES |
55 | TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES |
57 | CHAPTER 5 EXHAUST SYSTEMS SECTION 501 GENERAL |
58 | SECTION 502 REQUIRED SYSTEMS |
59 | EQUATION 5-1 |
65 | SECTION 503 MOTORS AND FANS SECTION 504 CLOTHES DRYER EXHAUST |
66 | TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT |
67 | SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT |
71 | SECTION 507 COMMERCIAL KITCHEN HOODS |
72 | TABLE 507.2.8 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE |
74 | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR SECTION 509 FIRE SUPPRESSION SYSTEMS |
75 | SECTION 510 HAZARDOUS EXHAUST SYSTEMS |
76 | TABLE 510.9 MINIMUM DUCT THICKNESS |
77 | TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS |
78 | TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 513 SMOKE CONTROL SYSTEMS |
80 | EQUATION 5-1 EQUATION 5-2 |
82 | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS |
83 | CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL |
84 | SECTION 602 PLENUMS |
85 | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION |
86 | TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa |
88 | SECTION 604 INSULATION SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL |
89 | SECTION 607 DUCT AND TRANSFER OPENINGS |
90 | [BF] TABLE 607.3.2.1 FIRE DAMPER RATING |
95 | CHAPTER 7 COMBUSTION AIR SECTION 701 GENERAL |
97 | CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL |
98 | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION |
99 | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES |
100 | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS |
101 | SECTION 805 FACTORY-BUILT CHIMNEYS |
102 | SECTION 806 METAL CHIMNEYS |
103 | CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 INCINERATORS AND CREMATORIES |
104 | SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES |
105 | SECTION 911 DUCT FURNACES SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS SECTION 914 SAUNA HEATERS SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES |
106 | SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES SECTION 918 FORCED-AIR WARM-AIR FURNACES SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS |
107 | SECTION 925 MASONRY HEATERS SECTION 926 GASEOUS HYDROGEN SYSTEMS SECTION 927 RADIANT HEATING SYSTEMS SECTION 928 EVAPORATIVE COOLING EQUIPMENT SECTION 929 SOLID FUEL HYDRONIC HEATERS |
109 | CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS SECTION 1004 BOILERS |
110 | TABLE 1004.3.1 BOILER TOP CLEARANCES SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS |
111 | SECTION 1007 BOILER LOW-WATER CUTOFF SECTION 1008 BOTTOM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK EQUATION 10-1 |
112 | TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING SECTION 1010 GAUGES SECTION 1011 TESTS |
113 | CHAPTER 11 REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS |
114 | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION SECTION 1104 SYSTEM APPLICATION REQUIREMENTS |
115 | TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
116 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
117 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
118 | TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL |
119 | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS |
120 | SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS EQUATION 11-1 |
121 | EQUATION 11-2 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS SECTION 1107 REFRIGERANT PIPING |
123 | SECTION 1108 FIELD TEST SECTION 1109 PERIODIC TESTING |
125 | CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE TABLE 1202.4—continued HYDRONIC PIPE TABLE 1202.5 HYDRONIC PIPE FITTINGS |
126 | SECTION 1203 JOINTS AND CONNECTIONS |
127 | SECTION 1204 PIPE INSULATION |
128 | SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS |
129 | SECTION 1209 EMBEDDED PIPING SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS TABLE 1210.4 GROUND-SOURCE LOOP PIPE |
130 | TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS |
133 | CHAPTER 13 FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS |
134 | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION |
135 | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING |
137 | CHAPTER 14 SOLAR SYSTEMS SECTION 1401 GENERAL SECTION 1402 INSTALLATION |
138 | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 MATERIALS |
139 | CHAPTER 15 REFERENCED STANDARDS ACCA AHRI AMCA ANSI |
140 | ASHRAE ASME ASSE ASSE |
141 | ASTM |
143 | AWS AWWA CSA |
144 | DOL FS ICC |
145 | IIAR MSS NAIMA NBBI NFPA |
146 | NSF SMACNA UL |
149 | CHAPTER 16 AUTOMATIC SPRINKLER SYSTEMS; FIRE SUPPRESSION SYSTEMS SECTION 1600 |
151 | CHAPTER 17 PROCESS PIPING SECTION 1700 PROCESS PIPING |
153 | APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS |
154 | FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS |
155 | INDEX |
161 | INSIDE OF BACK COVER – DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS BUREAU OF CONSTRUCTION CODES |
162 | ICC EVALUATION SERVICE |
163 | TURN TO ICC FOR YOUR GO-TO CODE RESOURCES |