Shopping Cart

No products in the cart.

MI PlumbingCode 2018 2ndptg

$56.60

Michigan Plumbing Code

Published By Publication Date Number of Pages
MI 2018
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

A fully integrated custom code based on the 2018 International Plumbing Code.

PDF Catalog

PDF Pages PDF Title
1 2018 MICHIGAN PLUMBING CODE
2 2018 MICHIGAN PLUMBING CODE INCORPORATING THE 2018 EDITION OF THE INTERNATIONAL PLUMBING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL PLUMBING CODE
14 TABLE OF CONTENTS
18 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
19 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF PLUMBING INSPECTION
SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL
20 SECTION 105 APPROVAL
SECTION 106 PERMITS
22 SECTION 107 INSPECTIONS AND TESTING
23 SECTION 108 VIOLATIONS
SECTION 109 MEANS OF APPEAL
SECTION 110 TEMPORARY EQUIPMENT, SYSTEMS AND USES
26 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
34 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
35 SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
36 SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
SECTION 307 STRUCTURAL SAFETY
37 SECTION 308 PIPING SUPPORT
TABLE 308.5 HANGER SPACING
38 SECTION 309 FLOOD HAZARD RESISTANCE
SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
39 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
40 [M] TABLE 314.2.2 CONDENSATE DRAIN SIZING
SECTION 315 PENETRATIONS
41 SECTION 316 ALTERNATIVE ENGINEERED DESIGN
42 CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
43 TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
44 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
45 TABLE 403.1 —continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
46 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
48 SECTION 406 AUTOMATIC CLOTHES WASHERS
SECTION 407 BATHTUBS
SECTION 408 BIDETS
SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
49 SECTION 412 FAUCETS AND FIXTURE FITTINGS
SECTION 413 FLOOR AND TRENCH DRAINS
50 SECTION 414 FLOOR SINKS
SECTION 415 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
SECTION 416 FOOD WASTE DISPOSER UNITS
SECTION 417 GARBAGE CAN WASHERS
SECTION 418 LAUNDRY TRAYS
SECTION 419 LAVATORIES
51 SECTION 420 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 421 SHOWERS
52 SECTION 422 SINKS
SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 URINALS
SECTION 425 WATER CLOSETS
SECTION 426 WHIRLPOOL BATHTUBS
53 SECTION 427 HEALTH CARE FIXTURES AND EQUIPMENT
54 CHAPTER 5 WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
55 SECTION 503 CONNECTIONS
SECTION 504 SAFETY DEVICES
56 SECTION 505 INSULATION
58 CHAPTER 6 WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
59 TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
60 TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
61 TABLE 605.3 WATER SERVICE PIPE
TABLE 605.8 MANUFACTURED PIPE NIPPLES
62 TABLE 605.4 WATER DISTRIBUTION PIPE
63 TABLE 605.5 PIPE FITTINGS
TABLE 605.7 VALVES
66 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
67 TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
68 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
69 TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS
70 FIGURE 608.9.1 PICTOGRAPH—DO NOT DRINK
TABLE 608.9.2.2 SIZE OF PIPE IDENTIFICATION
72 TABLE 608.16.1 MINIMUM REQUIRED AIR GAPS
73 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
74 SECTION 611 DRINKING WATER TREATMENT UNITS
SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
76 CHAPTER 7 SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
77 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
78 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
79 SECTION 705 JOINTS
81 TABLE 705.18 CAULKING FERRULE SPECIFICATIONS
TABLE 705.19 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
82 SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
83 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
84 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
85 SECTION 710 DRAINAGE SYSTEM SIZING
TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa
SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
86 SECTION 712 SUMPS AND EJECTORS
TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR
87 SECTION 713 COMPUTERIZED DRAINAGE DESIGN
SECTION 714 BACKWATER VALVES
SECTION 715 VACUUM DRAINAGE SYSTEMS
SECTION 716 REPLACEMENT OF UNDERGROUND BUILDING SEWERS AND BUILDING DRAINS BY PIPE-BURSTING METHODS
88 CHAPTER 8 INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
89 SECTION 803 SPECIAL WASTES
90 CHAPTER 9 VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 VENT TERMINALS
SECTION 904 OUTDOOR VENT EXTENSIONS
91 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 VENT PIPE SIZING
92 TABLE 906.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
93 TABLE 906.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 907 VENTS FOR STACK OFFSETS
SECTION 908 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION 909 FIXTURE VENTS
TABLE 909.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
94 SECTION 910 INDIVIDUAL VENT
SECTION 911 COMMON VENT
TABLE 911.3 COMMON VENT SIZES
SECTION 912 WET VENTING
TABLE 912.3 WET VENT SIZE
SECTION 913 WASTE STACK VENT
95 TABLE 913.4 WASTE STACK VENT SIZE
SECTION 914 CIRCUIT VENTING
SECTION 915 COMBINATION WASTE AND VENT SYSTEM
TABLE 915.2.2 SIZE OF COMBINATION WASTE AND VENT PIPE
96 SECTION 916 ISLAND FIXTURE VENTING
SECTION 917 SINGLE-STACK VENT SYSTEM
TABLE 917.2 SINGLE STACK SIZE
97 SECTION 918 AIR ADMITTANCE VALVES
SECTION 919 ENGINEERED VENT SYSTEMS
EQUATION 9-1
98 TABLE 919.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS ANDINDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
SECTION 920 COMPUTERIZED VENT DESIGN
100 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
101 SECTION 1003 INTERCEPTORS AND SEPARATORS
102 TABLE 1003.3.5.1 CAPACITY OF GREASE INTERCEPTORSa
103 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
104 CHAPTER 11 STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
105 TABLE 1102.5 SUBSOIL DRAIN PIPE
TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
106 FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
107 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
108 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
109 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
110 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
111 TABLE 1106.2 STORM DRAIN PIPE SIZING
SECTION 1107 SIPHONIC ROOF DRAINAGE SYSTEMS
SECTION 1108 SECONDARY (EMERGENCY) ROOF DRAINS
SECTION 1109 COMBINED SANITARY AND STORM PUBLIC SEWER
SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
112 SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
114 CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 MEDICAL GASES
SECTION 1203 OXYGEN SYSTEMS
116 CHAPTER 13 NONPOTABLE WATER SYSTEMS
118 CHAPTER 14 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
120 CHAPTER 15 REFERENCED STANDARDS
ANSI
ASHRAE
ASME
122 ASPE
ASSE
124 ASTM
129 AWS
AWWA
130 CISPI
CSA
133 IAPMO
ICC
ISEA
MSS
134 NFPA
NSF
135 PDI
PSAI
UL
136 APPENDIX A NONPOTABLE WATER SYSTEMS
SECTION A1301 GENERAL
FIGURE A1301.3 PICTOGRAPH—DO NOT DRINK
138 SECTION A1302 ON-SITE NONPOTABLE WATER REUSE SYSTEMS
139 TABLE A1302.7.1 LOCATION OF NONPOTABLE WATER REUSE STORAGE TANKS
140 SECTION A1303 NONPOTABLE RAINWATER COLLECTION AND DISTRIBUTION SYSTEMS
141 TABLE A1303.10.1 LOCATION OF RAINWATER STORAGE TANKS
142 SECTION A1304 RECLAIMED WATER SYSTEMS
144 APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES
146 APPENDIX C STRUCTURAL SAFETY
SECTION C101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
148 APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES
TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
149 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
150 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
151 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
152 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
154 APPENDIX E SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
158 TABLE E.1
TABLE E.2
159 FIGURE E103.3(1) EXAMPLE-SIZING
160 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
161 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
162 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
163 TABLE E103.3(3)-continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
164 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
165 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING)
166 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING)
167 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING)
168 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
169 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
170 FIGURE E103.3(7) FRICTION LOSS IN ROUGH PIPEa
171 SECTION E201 SELECTION OF PIPE SIZE
SECTION E202 DETERMINATION OF PIPE VOLUMES
172 TABLE E201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
173 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
174 TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
176 APPENDIX F SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
SECTION F1401 GENERAL
SECTION F1402 SYSTEM DESIGN AND SIZING
EQUATION F14-1
177 TABLE F1402.3 LOCATION OF SUBSURFACE IRRIGATION SYSTEM
TABLE F1403.1.1 DESIGN LOADING RATE
178 SECTION F1403 INSTALLATION
TABLE F1403.2 DISTRIBUTION PIPE
180 APPENDIX G VACUUM DRAINAGE SYSTEMS
SECTION G715 VACUUM DRAINAGE SYSTEMS
182 INDEX
194 HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR PLUM BING CODE
195 PROCTORED REMOTE ONLINE TESTING OPTION (PRONTO™)
196 ICC LEARNING CENTER
197 ICC DIGITAL CODES PREMIUM
MI PlumbingCode 2018 2ndptg
$56.60