MN EnergyCode 1stptg 2020.pdf
$65.00
Minnesota Energy Code with ANSI/ASHRAE/IES Standard 90.1-2016
Published By | Publication Date | Number of Pages |
MN | 2020 | 585 |
2020 City of Los Angeles amendment pages for integration with the 2019 California Building Code
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2020 MINNESOTA ENERGY CODE WITH ANSI/ASHRAE/IES STANDARD 90.1-2016 |
2 | 2020 MINNESOTA ENERGY CODE WITH ANSI/ASHRAE/IES STANDARD 90.1-2016 TITLE PAGE |
3 | COPYRIGHT |
4 | MINNESOTA DEPARTMENT OF LABOR AND INDUSTRY |
5 | IMPORTANT DISCLAIMER |
6 | PREFACE |
10 | EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE |
14 | TABLE OF CONTENTS |
16 | 2020 MINNESOTA BUILDING CODE ADMINISTRATION 1300.0010 ADMINISTRATION 1300.0020 TITLE 1300.0030 PURPOSE AND APPLICATION 1300.0040 SCOPE |
17 | 1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE 1300.0060 OPTIONAL ADMINISTRATION 1300.0070 DEFINITIONS |
18 | 1300.0080 CODE ADOPTION AND AMENDMENTS 1300.0090 DEPARTMENT OF BUILDING SAFETY 1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL |
20 | 1300.0120 PERMITS |
22 | 1300.0130 CONSTRUCTION DOCUMENTS |
23 | 1300.0140 VIOLATIONS 1300.0150 VIOLATIONS, PENALTY 1300.0160 FEES |
24 | 1300.0170 STOP WORK ORDER 1300.0180 UNSAFE BUILDINGS OR STRUCTURES |
25 | 1300.0190 TEMPORARY STRUCTURES AND USES 1300.0210 INSPECTIONS |
26 | 1300.0215 PLUMBING |
27 | 1300.0220 CERTIFICATE OF OCCUPANCY 1300.0225 MAINTENANCE 1300.0230 BOARD OF APPEALS |
28 | 1300.0240 DISCLAIMER CLAUSE 1300.0250 SEVERABILITY |
30 | 2015 MINNESOTA RESIDENTIAL ENERGY CODE 1322.0010 ADOPTION OF INTERNATIONAL ENERGY CONSERVATION CODE (IECC) BY REFERENCE 1322.0015 ADMINISTRATION AND PURPOSE 1322.0030 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES 1322.0040 ADMINISTRATIVE PROCEDURE CRITERIA 1322.0100 ADMINISTRATION FOR RESIDENTIAL ENERGY |
31 | 1322.0103 CONSTRUCTION DOCUMENTS |
32 | CHAPTER 1 [RE] SCOPE AND ADMINISTRATION CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS |
34 | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 CLIMATE ZONES |
35 | FIGURE R301.1 CLIMATE ZONES |
36 | TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
37 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
38 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
39 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
40 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
41 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
42 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
43 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
44 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
45 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
46 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
47 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
48 | TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
49 | SECTION R302 DESIGN CONDITIONS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
50 | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa |
53 | TABLE R402.1.3 EQUIVALENT U-FACTORSa |
54 | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
55 | SECTION R403 SYSTEMS |
56 | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION |
57 | TABLE R403.2.1 MINIMUM REQUIRED DUCT AND PLENUM INSULATION FOR DWELLING UNITS TABLE R403.4.2 MAXIMUM RUN LENGTH (feet)a |
58 | TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY TABLE R403.5.2 NUMBER OF BEDROOMS |
60 | TABLE R403.5.17 CLIMATIC DATA DESIGN CONDITIONS |
61 | SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY) SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) |
63 | TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
64 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
65 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
66 | CHAPTER 5 [RE] REFERENCED STANDARDS AAMA ACCA ASHRAE ASTM CSA |
67 | HVI ICC NFRC US-FTC WDMA |
68 | INDEX |
74 | 2020 MINNESOTA COMMERCIAL ENERGY CODE 1323.0001 TITLE 1323.0010 INCORPORATION BY REFERENCE OF THE INTERNATIONAL ENERGY CONSERVATION CODE—COMMERCIAL ENERGY PROVISIONS 1323.0020 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES |
75 | 1323.0030 ADMINISTRATIVE PROCEDURE CRITERIA 1323.0100 ADMINISTRATION FOR COMMERCIAL ENERGY CODE |
78 | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION |
80 | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS |
86 | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONES |
87 | FIGURE C301.1 CLIMATE ZONES |
88 | TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
89 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
90 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
91 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
92 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
93 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
94 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
95 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
96 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
97 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
98 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
99 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY |
100 | TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
101 | TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT |
102 | TABLE C303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT |
104 | CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL SECTION C402 BUILDING ENVELOPE REQUIREMENTS |
105 | EQUATION 4-1 EQUATION 4-2 TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES |
106 | TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD |
107 | TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHODa |
110 | EQUATION 4-3 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS |
111 | EQUATION 4-4 EQUATION 4-5 |
113 | TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES |
114 | SECTION C403 BUILDING MECHANICAL SYSTEMS TABLE C403.1.1 CLIMATIC DATA DESIGN CONDITIONS |
115 | EQUATION 4-6 EQUATION 4-7 |
116 | TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
117 | TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS |
118 | TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
119 | TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS |
120 | TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
121 | TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
122 | TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED |
123 | TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS |
124 | TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT |
125 | TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY TABLE C403.3.4 BOILER TURNDOWN |
127 | TABLE C403.4.4 VARIABLE SPEED DRIVE (VSD) REQUIREMENTS FOR DEMAND-CONTROLLED PUMPS |
128 | TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS |
129 | TABLE C403.5(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS |
132 | TABLE C403.7 EXHAUST AIR ENERGY RECOVERY |
133 | TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH |
134 | TABLE C403.8.1(1) FAN POWER LIMITATION |
135 | TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT |
136 | TABLE C403.8.5.1 COOLING SYSTEMS |
138 | TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
139 | TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS |
141 | TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS |
142 | EQUATION 4-8 |
143 | TABLE C403.11.1 MINIMUM REQUIRED DUCT AND PLENUM INSULATION |
144 | TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)a SECTION C404 SERVICE WATER HEATING (MANDATORY) |
145 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
146 | TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
147 | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS |
148 | SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS |
150 | EQUATION 4-9 |
151 | FIGURE C405.2.3.2 SIDELIT ZONE FIGURE C405.2.3.3(1) TOPLIT ZONE |
152 | FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR |
153 | EQUATION 4-10 |
154 | EQUATION 4-11 |
155 | TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
156 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
157 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES |
158 | TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
159 | TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS SECTION C406 ADDITIONAL EFFICIENCY PACKAGES |
160 | TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b |
161 | TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa |
162 | TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa |
163 | SECTION C407 TOTAL BUILDING PERFORMANCE |
165 | TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
166 | TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
167 | TABLE C407.5.1(2) HVAC SYSTEMS MAP |
168 | TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS |
169 | TABLE C407.5.1(4) NUMBER OF CHILLERS TABLE C407.5.1(5) WATER CHILLER TYPES SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING |
173 | FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST |
174 | CHAPTER 5 [CE] EXISTING BUILDINGS |
176 | CHAPTER 6 [CE] REFERENCED STANDARDS AAMA AHAM AHRI |
177 | AMCA ANSI APSP ASHRAE |
178 | ASME ASTM |
179 | CRRC CSA CTI DASMA DOE |
180 | ICC IEEE IES ISO |
181 | NEMA NFPA NFRC SMACNA UL US-FTC |
182 | WDMA |
184 | APPENDIX CA SOLAR-READY ZONE—COMMERCIAL |
186 | INDEX |
196 | ANSI/ASHRAE/IES STANDARD 90.1-2016 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS (I-P EDITION) |
197 | ASHRAE STANDING STANDARD PROJECT COMMITTEE 90.1 |
198 | ASHRAE STANDARDS COMMITTEE 2016-2017 SPECIAL NOTE DISCLAIMER ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS |
200 | CONTENTS |
202 | FOREWORD |
204 | 1 PURPOSE |
206 | 2 SCOPE |
208 | 3 DEFINITIONS, ABBREVIATIONS, AND ACRONYMS |
213 | FIGURE 3.2-1 COMPUTING THE DAYLIGHT AREA UNDER ROOF MONITORS |
214 | FIGURE 3.2-2 COMPUTING THE DAYLIGHT AREA UNDER SKYLIGHTS |
215 | FIGURE 3.2-3 COMPUTING THE PRIMARY SIDELIGHTED AREA |
216 | FIGURE 3.2-4 COMPUTING THE SECONDARY SIDELIGHTED AREA |
232 | TABLE 3.2 HEATED SPACE CRITERIA |
240 | 4 ADMINISTRATION AND ENFORCEMENT |
242 | TABLE 4.2.1.1 BUILDING PERFORMANCE FACTOR (BPF) |
244 | 5 BUILDING ENVELOPE |
250 | TABLE 5.5-0 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE (A,B)* |
251 | TABLE 5.5-1 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 1 (A,B)* |
252 | TABLE 5.5-2 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 2 (A,B)* |
253 | TABLE 5.5-3 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 3 (A,B,C)* |
254 | TABLE 5.5-4 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)* |
255 | TABLE 5.5-5 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5 (A,B,C)* |
256 | TABLE 5.5-6 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6 (A,B)* |
257 | TABLE 5.5-7 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 7* |
258 | TABLE 5.5-8 BUILDING REQUIREMENTS FOR CLIMATE ZONE 8* |
259 | FIGURE 5.5.2 EXTERIOR AND SEMIEXTERIOR BUILDING ENVELOPE TABLE 5.5.3.1.1 INCREASED ROOF INSULATION LEVELS |
263 | TABLE 5.5.4.4.1 SHGC MULTIPLIERS FOR PERMANENT PROJECTIONS |
270 | 6 HEATING, VENTILATING, AND AIR CONDITIONING |
279 | TABLE 6.4.3.4.3 MAXIMUM DAMPER LEAKAGE, CFM PER FT2 AT 1.0 IN. OF WATER |
282 | TABLE 6.4.3.10.1 DDC APPLICATIONS AND QUALIFICATIONS |
287 | TABLE 6.5.1-1 MINIMUM FAN-COOLING UNIT SIZE FOR WHICH AN ECONOMIZER IS REQUIRED TABLE 6.5.1-2 ELIMINATE REQUIRED ECONOMIZER FOR COMFORT COOLING BY INCREASING COOLING EFFICIENCY |
288 | TABLE 6.5.1.1.3 HIGH-LIMIT SHUTOFF CONTROL SETTINGS FOR AIR ECONOMIZERS |
289 | TABLE 6.5.1.2.1 FLUID ECONOMIZER SIZING DRY-BULB AND WET-BULB REQUIREMENTS |
290 | TABLE 6.5.1.3 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS |
294 | TABLE 6.5.3.1-1 FAN POWER LIMITATION TABLE 6.5.3.1-2 FAN POWER LIMITATION PRESSURE DROP AJUSTMENT |
295 | TABLE 6.5.3.2.1 FAN AIRFLOW CONTROL |
297 | TABLE 6.5.4.1 BOILER TURNDOWN |
298 | TABLE 6.5.4.2 PUMP FLOW CONTROL REQUIREMENTS |
299 | TABLE 6.5.4.6 PIPING SYSTEM DESIGN MAXIMUM FLOW RATE IN GPM |
302 | TABLE 6.5.6.1-1 EXHAUST AIR ENERGY RECOVERY REQUIREMENTS FOR VENTILATION SYSTEMS OPERATING LESS THAN 8000 HOURS PER YEAR TABLE 6.5.6.1-2 EXHAUST AIR ENERGY RECOVERY REQUIREMENTS FOR VENTILATION SYSTEMS OPERATING GREATER THAN OR EQUAL TO 8000 HOURS PER YEAR |
303 | TABLE 6.5.7.2.2 MAXIMUM NET EXHAUST FLOW RATE. CFM PER LINEAR FOOT OF HOOD LENGTH |
305 | TABLE 6.5.9 HOT-GAS BYPASS LIMITATION |
306 | TABLE 6.6.1 POWER USAGE EFFECTIVENESS (PUE) MAXIMUM |
309 | TABLE 6.8.1-1 ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS |
310 | TABLE 6.8.1-1 ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS—MINIMUM EFFICIENCY REQUIREMENTS |
311 | TABLE 6.8.1-2 ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
312 | TABLE 6.8.1-2 ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
313 | TABLE 6.8.1-3 WATER-CHILLING PACKAGES—MINIMUM EFFICIENCY REQUIREMENTS |
314 | TABLE 6.8.1-4 ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
315 | TABLE 6.8.1-4 ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR CONDITIONER HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (CONTINUED) TABLE 6.8.1-5 WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES, AND UNIT HEATERS—MINIMUM EFFICIENCY REQUIREMENTS |
316 | TABLE 6.8.1-6 GAS AND OIL FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS |
317 | TABLE 6.8.1-7 PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS TABLE 6.8.1-8 HEAT TRANSFER EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS |
318 | TABLE 6.8.1-9 ELECTRICALLY OPERATED VARIABLE-REFRIGERANT FLOW AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS |
319 | TABLE 6.8.1-10 ELECTRICALLY OPERATED VARIABLE-REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS TABLE 6.8.1-10 ELECTRICALLY OPERATED VARIABLE-REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (CONTINUED) |
320 | TABLE 6.8.1-10 ELECTRICALLY OPERATED VARIABLE-REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS (CONTINUED) |
321 | TABLE 6.8.1-11 AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS |
322 | TABLE 6.8.1-11 AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS (CONTINUED) |
323 | TABLE 6.8.1-12 COMMERCIAL REFRIGERATOR AND FREEZERS—MINMUM EFFICIENCY REQUIREMENTS |
324 | TABLE 6.8.1-13 COMMERCIAL REFRIGERATION—MINIMUM EFFICIENCY REQUIREMENTS TABLE 6.8.1-13 COMMERCIAL REFRIGERATION—MINIMUM EFFICIENCY REQUIREMENTS (CONTINUED) |
325 | TABLE 6.8.1-14 VAPOR COMPRESSION BASED INDOOR POOL DEHUMIDIFIERS—MINIMUM EFFICIENCY REQUIREMENTS TABLE 6.8.1-15 ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE-PACKAGE AND REMOTE CONDENSER, WITHOUT ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTS TABLE 6.8.1-16 ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE PACKAGE AND REMOTE CONDENSER, WITH ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTS |
326 | TABLE 6.8.2 MINIMUM DUCT INSULATION R-VALUE TABLE 6.8.3-1 MINIMUM PIPING INSULATION THICKNESS HEATING AND HOT WATER SYSTEMS (Steam, Steam Condensate, Hot-Water Heating and Domestic Water Systems) |
327 | TABLE 6.8.3-2 MINIMUM PIPING INSULATION THICKNESS COOLING SYSTEMS (Chilled Water, Brine, and Refrigerant) |
328 | 7 SERVICE WATER HEATING |
332 | TABLE 7.8 PERFORMANCE REQUIREMENTS FOR WATER-HEATING EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS |
334 | 8 POWER |
336 | TABLE 8.4.4 MINIMUM NOMINAL EFFICIENCY LEVELS FOR LOW VOLTAGE DRY TYPE DISTRIBUTION TRANSFORMERS |
338 | 9 LIGHTING |
345 | TABLE 9.4.2-1 EXTERIOR LIGHTING ZONES |
346 | TABLE 9.4.2-2 INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
347 | TABLE 9.4.2-2 INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS (CONTINUED) |
350 | TABLE 9.5.1 LIGHTING POWER DENSITY ALLOWANCES USING THE BUILDING AREA METHOD |
351 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD |
352 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
353 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
354 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
355 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
356 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
357 | TABLE 9.6.1 LIGHTING POWER DENSITY ALLOWANCES USING THE SPACE-BY-SPACE METHOD AND MINIMUM CONTROL REQUIREMENTS USING EITHER METHOD (CONTINUED) |
358 | TABLE 9.6.3 CONTROL FACTORS USED IN CALCULATING ADDITIONAL INTERIOR LIGHTING POWER ALLOWANCE |
360 | 10 OTHER EQUIPMENT |
363 | TABLE 10.8-1 MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP ELECTRIC MOTORS) AT 60 HZ |
364 | TABLE 10.8-2 MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZ |
365 | TABLE 10.8-3 MINIMUM AVERAGE FULL LOAD EFFICIENCY FOR POLYPHASE SMALL ELECTRIC MOTORS TABLE 10.8-4 MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORS |
366 | TABLE 10.8-5 MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR FIRE PUMP ELECTRIC MOTORS |
368 | 11 ENERGY COST BUDGET METHOD |
373 | TABLE 115.1 MODELING REQUIREMENTS FOR CALCULATING DESIGN ENERGY COST AND ENERGY COST BUDGET |
374 | TABLE 11.5.1 MODELING REQUIREMENTS FOR CALCULATING DESIGN ENERGY COST AND ENERGY COST BUDGET (CONTINUED) |
375 | TABLE 11.5.1 MODELING REQUIREMENTS FOR CALCULATING DESIGN ENERGY COST AND ENERGY COST BUDGET (CONTINUED) |
376 | TABLE 11.5.1 MODELING REQUIREMENTS FOR CALCULATING DESIGN ENERGY COST AND ENERGY COST BUDGET (CONTINUED) |
377 | TABLE 11.5.1 MODELING REQUIREMENTS FOR CALCULATING DESIGN ENERGY COST AND ENERGY COST BUDGET (CONTINUED) |
378 | FIGURE 11.5.2 HVAC SYSTEMS MAP |
379 | TABLE 11.5.2-1 BUDGET SYSTEM DESCRIPTIONS |
380 | TABLE 11.5.2-2 NUMBER OF CHILLERS |
382 | 12 NORMATIVE REFERENCES AHRI AMCA AMMA |
383 | ANSI ASME ASHRAE AHAM ASTM |
384 | CRRC CTI DASMA IES ISO |
385 | NEMA NFRC NFPA TIA UL U.S. DOE U.S. SEC |
386 | NORMATIVE APPENDIX A RATED R-VALUE OF INSULATION AND ASSEMBLY U-FACTOR, C-FACTOR AND F-FACTOR DETERMINATIONS |
389 | TABLE A2.2.3 ASSEMBLY U-FACTORS FOR ROOFS WITH INSULATION ENTIRELY ABOVE DECK |
390 | TABLE A2.3.3 ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS |
391 | TABLE A2.4.2 SINGLE-RAFTER ROOFS |
392 | TABLE A2.5.2 ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH STEEL JOISTS (4.0 ft on Center) |
397 | TABLE A3.1-1 ASSEMBLY U-FACTORS FOR ABOVE GRADE CONCRETE WALLS AND MASONRY WALLS |
398 | TABLE A3.1-1 ASSEMBLY U-FACTORS FOR ABOVE GRADE CONCRETE WALLS AND MASONRY WALLS (CONTINUED) |
399 | TABLE A3.1-1 ASSEMBLY U-FACTORS FOR ABOVE GRADE CONCRETE WALLS AND MASONRY WALLS (CONTINUED) |
400 | TABLE A3.1-1 ASSEMBLY U-FACTORS FOR ABOVE GRADE CONCRETE WALLS AND MASONRY WALLS (CONTINUED) |
401 | TABLE A3.1-2 ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HC FOR CONCRETE |
402 | TABLE A3.1-2 ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HC FOR CONCRETE (CONTINUED) |
403 | ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HC FOR CONCRETE BLOCK WALLS |
404 | ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HC FOR CONCRETE BLOCK WALLS (CONTINUED) |
405 | ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HC FOR CONCRETE BLOCK WALLS (CONTINUED) |
406 | TABLE A3.1-4 EFFECTIVE R-VALUES FOR INSULATION/FRAMING LAYERS ADDED TO ABOVE-GRADE MASS WALLS AND BELOW-GRADE WALLS |
407 | TABLE A3.2.3 ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS |
408 | TABLE A3.3.3.1 ASSEMBLY U-FACTORS FOR STEEL-FRAME WALLS |
409 | TABLE A3.4.3.1 ASSEMBLY U-FACTORS FOR WOOD-FRAME WALLS |
414 | TABLE A4.2.1 ASSEMBLY C-FACTORS FOR BELOW GRADE WALLS |
415 | TABLE A5.2.3.1 ASSEMBLY U-FACTORS FOR MASS FLOORS |
416 | TABLE A5.3.3.1 ASSEMBLY U-FACTORS FOR STEEL-JOIST FLOORS |
417 | TABLE A5.4.3.1 ASSEMBLY U-FACTORS FOR WOOD JOIST FLOORS |
418 | TABLE A6.3.1 ASSEMBLY F-FACTORS FOR SLAB-ON-GRADE FLOORS |
420 | TABLE A8.1-1 ASSEMBLY U-FACTORS FOR UNLABELED SKYLIGHTS |
421 | TABLE A8.1-1 ASSEMBLY U-FACTORS FOR UNLABELED SKYLIGHTS (CONTINUED) |
422 | TABLE A8.1-2 ASSEMBLY SHGCS AND ASSEMBLY VISIBLE TRANSMITTANCES (VTs) FOR UNLABELED SKYLIGHTS |
423 | TABLE A8.2 ASSEMBLY U-FACTORS, ASSEMBLY SHGCS AND ASSEMBLY VISIBLE TRANSMITTANCES (VTs) FOR UNLABELED VERTICAL FENESTRATION |
426 | EQUATION A9.4-1 |
427 | FIGURE A9.4.6.1 GEOMETRY OF SINGLE-LAYER FIBERGLASS BATT EQUATION A9.4-2 EQUATION A9.4-3 |
428 | EQUATION A9.4-4 EQUATION A9.4-5 EQUATION A9.4-6 EQUATION A9.4-7 EQUATION A9.4-8 |
429 | FIGURE A9.4.6.2-1 GEOMETRY OF DOUBLE LAYERS OF FIBERGLASS BATTS EQUATION A9.4-9 EQUATION A9.4-10 EQUATION A9.4-11 |
430 | FIGURE A9.4.6.2-2 COMPRESSION OF DOUBLE LAYERS OF FIBERGLASS INSULATION EQUATION A9.4-12 EQUATION A9.4-13 EQUATION A9.4-14 |
431 | EQUATION A9.4-15A EQUATION A9.4-15B EQUATION A9.4-16 EQUATION A9.4-17 EQUATION A9.4-18 |
432 | EQUATION A9.4-19 EQUATION A9.4-20 EQUATION A9.4-21 EQUATION A9.4-22 |
433 | FIGURE A9.4.6.3 GEOMETRY OF SINGLE CAVITY LAYER OR DOUBLE-LAYER WALL EQUATION A9.4-23 EQUATION A9.4-24 |
434 | EQUATION A9.4-25 EQUATION A9.4-26 EQUATION A9.4-27 EQUATION A9.4-28 EQUATION A9.4-29 EQUATION A9.4-30 EQUATION A9.4-31 |
435 | EQUATION A9.4-32 EQUATION A9.4-33 EQUATION A9.4-34 EQUATION A9.4-35 EQUATION A9.4-36 EQUATION A9.4-37 |
436 | EQUATION A9.4-38 EQUATION A9.4-39 EQUATION A9.4-40 EQUATION A9.4-41 EQUATION A9.4-42 EQUATION A9.4-43 EQUATION A9.4-44 EQUATION A9.4-45 |
437 | TABLE A9.2-1 EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FOR ROOF AND FLOOR INSULATION INSTALLED BETWEEN METAL FRAMING (4 ft on Center) TABLE A9.2-2 EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FOR WALL INSULATION INSTALLED BETWEEN STEEL FRAMING |
438 | TABLE A9.4.2-1 VALUES FOR CAVITY AIR SPACES |
439 | TABLE A9.4.2-2 EMITTANCE VALUES OF VARIOUS SURFACES AND EFFECTIVE EMITTANCES OF AIR SPACES TABLE A9.4.3 EFFECTIVE R-VALUES FOR FIBERGLASS |
440 | TABLE A9.4.4-1 R-VALUES FOR BUILDING MATERIALS TABLE A9.4.4-2 THERMAL CONDUCTIVITY OF CONCRETE BLOCK MATERIAL |
441 | TABLE A9.4.6.1 FIBERGLASS REFERENCE PROPERTIES |
442 | INFORMATIVE APPENDIX B |
444 | NORMATIVE APPENDIX C METHODOLOGY FOR BUILDING ENVELOPE TRADE-OFF OPTION IN SECTION 5.6 |
445 | FIGURE C1.4 SKYLIGHT WELL DIMENSIONS |
452 | INFORMATIVE APPENDIX D |
454 | INFORMATIVE APPENDIX E INFORMATIVE REFERENCES AABC BLAST CTI CWEC DATA DOE-2 MICA |
455 | THE GREEN GRID ADMINISTRATION IWEC2 DATA NEBB SMACNA TMY3 DATA |
458 | INFORMATIVE APPENDIX F U.S. DEPARTMENT OF ENERGY MINIMUM ENERGY EFFICIENCY REQUIREMENTS |
459 | FIGURE F-1 MAP OF THE REGIONS FOR THE ANALYSIS OF CENTRAL AIR CONDITIONERS AND HEAT PUMPS TABLE F-1 U.S. MINIMUM EFFICIENCY REQUIREMENTS FOR SINGLE-PHASE AIR CONDITIONERS AND HEAT PUMPS THAT HAVE A COOLING CAPACITY < 65,000 Btu/h |
460 | TABLE F-2 MINIMUM ENERGY EFFICIENCY REQUIREMENTS FOR WATER HEATERS |
462 | NORMATIVE APPENDIX G PERFORMANCE RATING METHOD |
465 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE |
466 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
467 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
468 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
469 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
470 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
471 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
472 | TABLE G3.1 MODELING REQUIREMENTS FOR CALCULATING PROPOSED AND BASELINE BUILDING PERFORMANCE (CONTINUED) |
483 | TABLE G3.1.1-1 BASELINE BUILDING VERTICAL FENESTRATION PERCENTAGE OF GROSS ABOVE-GRADE-WALL AREA TABLE G3.1.1-2 BASELINE SERVICE WATER-HEATING SYSTEM |
484 | TABLE G3.1.1-3 BASELINE HVAC SYSTEM TYPES TABLE G3.1.1-4 BASELINE SYSTEM DESCRIPTIONS TABLE G3.1.2.6 CLIMATE CONDITIONS UNDER WHICH ECONOMIZERS ARE INCLUDED FOR COMFORT COOLING FOR BASELINE SYSTEMS 3 THROUGH 8 AND 11, 12 AND 13 |
485 | TABLE G3.1.2.7 ECONOMIZER HIGH-LIMIT SHUTOFF TEMPERATURE TABLE G3.1.2.9 BASELINE FAN BRAKE HORSEPOWER TABLE G3.1.3.7 TYPE AND NUMBER OF CHILLERS TABLE G3.1.3.11 HEAT-REJECTION LEAVING WATER TEMPERATURE TABLE G3.1.3.15 PART-LOAD PERFORMANCE FOR VAV FAN SYSTEMS |
486 | TABLE G3.4-1 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONES 0 AND 1 (A,B)* |
487 | TABLE G3.4-2 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 2 (A,B)* |
488 | TABLE G3.4-3 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 3 (A,B,C)* |
489 | TABLE G3.4-4 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)* |
490 | TABLE G3.4-5 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5 (A,B,C)* |
491 | TABLE G3.4-6 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 6 (A,B)* |
492 | TABLE G3.4-7 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 7* |
493 | TABLE G3.4-8 PERFORMANCE RATING METHOD BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 8* |
494 | TABLE G3.5.1 PERFORMANCE RATING METHOD AIR CONDITIONERS TABLE G3.5.2 PERFORMANCE RATING METHOD ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
495 | TABLE G3.5.3 PERFORMANCE RATING METHOD WATER CHILLING PACKAGES—MINIMUM EFFICIENCY REQUIREMENTS TABLE G3.5.4 PERFORMANCE RATING METHOD ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS PACKAGED TERMINAL HEAT PUMPS TABLE G3.5.5 WARM-AIR FURNACES AND UNIT HEATERS TABLE G3.5.6 GAS-FIRED BOILERS—MINIMUM EFFICIENCY REQUIREMENTS |
496 | TABLE G3.6 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS |
497 | TABLE G3.7 PERFORMANCE RATING METHOD LIGHTING POWER DENSITY ALLOWANCES AND OCCUPANCY SENSOR REDUCTIONS USING THE SPACE-BY-SPACE METHOD |
498 | TABLE G3.7 PERFORMANCE RATING METHOD LIGHTING POWER DENSITY ALLOWANCES AND OCCUPANCY SENSOR REDUCTIONS USING THE SPACE-BY-SPACE METHOD (CONTINUED) |
499 | TABLE G3.7 PERFORMANCE RATING METHOD LIGHTING POWER DENSITY ALLOWANCES AND OCCUPANCY SENSOR REDUCTIONS USING THE SPACE-BY-SPACE METHOD (CONTINUED) |
500 | TABLE G3.8 PERFORMANCE RATING METHOD LIGHTING POWER DENSITIES USING THE BUILDING AREA METHOD |
501 | TABLE G3.9.1 PERFORMANCE RATING METHOD MOTOR EFFICIENCY REQUIREMENTS TABLE G3.9.2 PERFORMANCE RATING METHOD BASELINE ELEVATOR MOTOR TABLE G3.9.3 PERFORMANCE RATING METHOD HYDRAULIC ELEVATOR MOTOR EFFICIENCY TABLE G3.10.1 PERFORMANCE RATING METHOD COMMERCIAL REFRIGERATORS AND FREEZERS |
502 | TABLE G3.10.2 PERFORMANCE RATING METHOD COMMERCIAL REFRIGERATION |
504 | INFORMATIVE APPENDIX H ADDENDA DESCRIPTION INFORMATION TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 |
505 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
506 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
507 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
508 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
509 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
510 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
511 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
512 | TABLE H-1 ADDENDA TO ANSI/ASHRAE/IES STANDARD 90.1-2013 (CONTINUED) |
514 | ANNEX 1 REFERENCE STANDARD REPRODUCTION ANNEX—ASHRAE STANDARD 169 |
515 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY |
516 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
517 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
518 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
519 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
520 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
521 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
522 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
523 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
524 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
525 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
526 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
527 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
528 | TABLE ANNEX1-1 ASHRAE STANDARD 169-2013, TABLE B-1: U.S. CLIMATE ZONES BY STATE AND COUNTY (CONTINUED) |
529 | FIGURE ANNEX1-1 ASHRAE STANDARD 169-2013, FIGURE B-1: CLIMATE ZONES FOR UNITED STATES COUNTIES |
530 | TABLE ANNEX1-2 ASHRAE STANDARD 169-2013, TABLE A-5: CANADA STATIONS AND CLIMATE ZONES |
531 | TABLE ANNEX1-2 ASHRAE STANDARD 169-2013, TABLE A-5: CANADA STATIONS AND CLIMATE ZONES (CONTINUED) |
532 | TABLE ANNEX1-2 ASHRAE STANDARD 169-2013, TABLE A-5: CANADA STATIONS AND CLIMATE ZONES (CONTINUED) |
533 | TABLE ANNEX1-2 ASHRAE STANDARD 169-2013, TABLE A-5: CANADA STATIONS AND CLIMATE ZONES (CONTINUED) |
534 | TABLE ANNEX1-2 ASHRAE STANDARD 169-2013, TABLE A-5: CANADA STATIONS AND CLIMATE ZONES (CONTINUED) |
535 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES |
536 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
537 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
538 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
539 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
540 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
541 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
542 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
543 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
544 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
545 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
546 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
547 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
548 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
549 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
550 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
551 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
552 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
553 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
554 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
555 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
556 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
557 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
558 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
559 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
560 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
561 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
562 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
563 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
564 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
565 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
566 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
567 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
568 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
569 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
570 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
571 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
572 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
573 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
574 | TABLE ANNEX1-3 ASHRAE STANDARD 169-2013, TABLE A-6: INTERNATIONAL STATIONS AND CLIMATE ZONES (CONTINUED) |
577 | TABLE ANNEX1-4 ASHRAE STANDARD 169-2013, TABLE A-3: THERMAL CLIMATE ZONE DEFINITIONS FIGURE ANNEX1-2 ASHRAE STANDARD 169-2013, FIGURE A-1: THERMAL CLIMATE ZONES AS A FUNCTION OF HEATING AND COOLING DEGREE-DAYS |
578 | FIGURE ANNEX1-3 ASHRAE STANDARD 169-2013, FIGURE C-2: WORLD CLIMATE ZONES MAP |
580 | POLICY STATEMENT DEFINING ASHRAE’S CONCERN FOR THE ENVIRONMENTAL IMPACT OF ITS ACTIVITIES |
581 | ABOUT ASHRAE IMPORTANT NOTICES ABOUT THIS STANDARD |
582 | HELPFUL TOOLS FOR LEARNING AND APPLYING YOUR ENERGY CODE |
583 | ICC EVALUATION SERVICE |
584 | ICC ASSESSMENT CENTER |
585 | ICC’S DIGITAL CODES LIBRARY |