PDF Pages PDF Title
1 2020 MINNESOTA MECHANICAL AND FUEL GAS CODE WITH ANSI/ASHRAE STANDARD 154-2016 AND ANSI/ASHRAE STANDARD 62.2-2016
2 2020 MINNESOTA MECHANICAL AND FUEL GAS CODE WITH ANSI/ASHRAE STANDARD 154-2016 AND ANSI/ASHRAE STANDARD 62.2-2016 TITLE PAGE
3 COPYRIGHT
4 MINNESOTA DEPARTMENT OF LABOR AND INDUSTRY
5 IMPORTANT DISCLAIMER
6 2020 MINNESOTA MECHANICAL CODE
2020 MINNESOTA MECHANICAL CODE SYMBOLS AND NOTATIONS IN THE CODE
8 PREFACE
12 EFFECTIVE USE OF THE INTERNATIONAL MECHANICAL CODE
16 2020 MINNESOTA BUILDING CODE ADMINISTRATION TABLE OF CONTENTS
18 2020 MINNESOTA BUILDING CODE ADMINISTRATION
1300.0010 ADMINISTRATION
1300.0020 TITLE
1300.0030 PURPOSE AND APPLICATION
1300.0040 SCOPE
19 1300.0050 CHAPTERS OF MINNESOTA STATE BUILDING CODE
1300.0060 OPTIONAL ADMINISTRATION
1300.0070 DEFINITIONS
20 1300.0080 CODE ADOPTION AND AMENDMENTS
1300.0090 DEPARTMENT OF BUILDING SAFETY
1300.0110 DUTIES AND POWERS OF BUILDING OFFICIAL
22 1300.0120 PERMITS
24 1300.0130 CONSTRUCTION DOCUMENTS
25 1300.0140 VIOLATIONS
1300.0150 VIOLATIONS, PENALTY
1300.0160 FEES
26 1300.0170 STOP WORK ORDER
1300.0180 UNSAFE BUILDINGS OR STRUCTURES
27 1300.0190 TEMPORARY STRUCTURES AND USES
1300.0210 INSPECTIONS
28 1300.0215 PLUMBING
29 1300.0220 CERTIFICATE OF OCCUPANCY
1300.0225 MAINTENANCE
1300.0230 BOARD OF APPEALS
30 1300.0240 DISCLAIMER CLAUSE
1300.0250 SEVERABILITY
32 2020 MINNESOTA MECHANICAL CODE TABLE OF CONTENTS
36 2020 MINNESOTA MECHANICAL CODE
1346.0050 TITLE; INCORPORATION BY REFERENCE
1346.0060 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
37 1346.0101 SCOPE
1346.0102 EXISTING INSTALLATIONS
1346.0103 MAINTENANCE
1346.0104 ADDITIONS, ALTERATIONS, RENOVATIONS, OR REPAIRS
1346.0105 WORK EXEMPT FROM PERMIT
1346.0106 REQUIRED INSPECTIONS
1346.0108 AUTHORITY TO CONDEMN MECHANICAL SYSTEMS
1346.0109 AUTHORITY TO ORDER DISCONNECTION OF ENERGY SOURCES
38 1346.0110 CONNECTION AFTER ORDER TO DISCONNECT
40 CHAPTER 1 SCOPE AND ADMINISTRATION
42 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
54 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL
55 SECTION 302 PROTECTION OF STRUCTURE
56 SECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION
58 SECTION 305 PIPING SUPPORT
TABLE 305.4 PIPING SUPPORT SPACINGa
SECTION 306 ACCESS AND SERVICE SPACE
60 SECTION 307 CONDENSATE DISPOSAL
TABLE 307.2.2 CONDENSATE DRAIN SIZING
61 SECTION 308 CLEARANCE REDUCTION
SECTION 309 TEMPERATURE CONTROL
62 TABLE 308.4.2 CLEARANCE REDUCTION METHODSb
SECTION 310 EXPLOSION CONTROL
SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS
63 SECTION 313 CARBON MONOXIDE ALARMS
64 CHAPTER 4 VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR INTAKE OPENINGS
65 SECTION 402 NATURAL VENTILATION
SECTION 403 MECHANICAL VENTILATION
66 EQUATION 4-1
TABLE 403.3.1.1.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
67 EQUATION 4-5
TABLE 403.3.1.1.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
68 SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES
SECTION 407 AMBULATORY CARE FACILITIES AND GROUP I-2 OCCUPANCIES
69 TABLE 403.3.1.1 MINIMUM VENTILATION RATES
70 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
71 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
72 TABLE 403.3.1.1—continued MINIMUM VENTILATION RATES
74 CHAPTER 5 EXHAUST SYSTEMS
SECTION 501 GENERAL
75 TABLE 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN DWELLINGS
76 TABLE 501.4.2 MAKEUP AIR OPENING SIZING TABLE FOR NEW AND EXISTING DWELLINGS
77 SECTION 502 REQUIRED SYSTEMS
78 TABLE 501.4.3(1) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLINGS (REFER TO ITEM 4 IN SECTION 501.4.3 TO DETERMINE APPLICABILITY OF THIS TABLE)
79 TABLE 501.4.3(2) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLINGS (REFER TO ITEM 5 IN SECTION 501.4.3 TO DETERMINE APPLICABILITY OF THIS TABLE)
80 TABLE 501.4.3(3) PROCEDURE TO DETERMINE MAKEUP AIR QUANTITY FOR EXHAUST APPLIANCES IN EXISTING DWELLINGS (REFER TO ITEM 6 IN SECTION 501.4.3 TO DETERMINE APPLICABILITY OF THIS TABLE
81 EQUATION 5-1
87 SECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST
88 TABLE 504.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
89 SECTION 505 DOMESTIC COOKING EXHAUST EQUIPMENT
90 SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT
91 SECTION 507 COMMERCIAL KITCHEN HOODS
SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS
93 TABLE 510.9 MINIMUM DUCT THICKNESS
TABLE 510.9.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS
94 SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS
SECTION 513 SMOKE CONTROL SYSTEMS
95 TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
96 EQUATION 5-2
97 EQUATION 5-3
99 SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS
100 CHAPTER 6 DUCT SYSTEMS
SECTION 601 GENERAL
101 SECTION 602 PLENUMS
103 SECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESS FOR SINGLE DWELLING UNITSa
105 SECTION 604 INSULATION
106 SECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL
107 SECTION 607 DUCT AND TRANSFER OPENINGS
108 [BF] TABLE 607.3.2.1 FIRE DAMPER RATING
114 CHAPTER 7 COMBUSTION AIR
SECTION 701 GENERAL
116 CHAPTER 8 CHIMNEYS AND VENTS
SECTION 801 GENERAL
117 SECTION 802 VENTS
TABLE 802.2 VENT APPLICATION
118 SECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES
119 TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS
120 SECTION 805 FACTORY-BUILT CHIMNEYS
121 SECTION 806 METAL CHIMNEYS
122 CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
123 SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS
SECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
124 SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS
SECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
125 SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES
SECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS
SECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
126 SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 RADIANT HEATING SYSTEMS
SECTION 928 EVAPORATIVE COOLING EQUIPMENT
SECTION 929 HIGH-VOLUME LARGE-DIAMETER FANS
128 CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
129 SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS
TABLE 1004.3.1 BOILER TOP CLEARANCES
130 SECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF
131 SECTION 1008 BOTTOM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
TABLE 1009.2 CLOSED-TYPE EXPANSION TANK SIZING
132 SECTION 1010 GAUGES
SECTION 1011 TESTS
134 CHAPTER 11 REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS
135 SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
136 TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
137 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
138 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
139 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
140 TABLE 1103.1—continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL
141 SECTION 1104 SYSTEM APPLICATION REQUIREMENTS
142 TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS
SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
143 EQUATION 11-1
EQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
144 TABLE 1106.5.2 MINIMUM EXHAUST RATES
SECTION 1107 REFRIGERANT PIPING
145 SECTION 1108 FIELD TEST
146 [F] SECTION 1109 PERIODIC TESTING
148 CHAPTER 12 HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
149 TABLE 1202.5 HYDRONIC PIPE FITTINGS
SECTION 1203 JOINTS AND CONNECTIONS
151 SECTION 1204 PIPE INSULATION
SECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
152 SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS
SECTION 1209 EMBEDDED PIPING
SECTION 1210 PLASTIC PIPE GROUND-SOURCE HEAT PUMP LOOP SYSTEMS
153 TABLE 1210.4 GROUND-SOURCE LOOP PIPE
TABLE 1210.5 GROUND-SOURCE LOOP PIPE FITTINGS
156 CHAPTER 13 FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS
157 SECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION
158 SECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING
160 CHAPTER 14 SOLAR THERMAL SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 DESIGN AND INSTALLATION
162 SECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 LABELING
164 CHAPTER 15 REFERENCED STANDARDS
ACCA
AHRI
AMCA
ANSI
165 ASHRAE
ASME
166 ASSE
ASSE
ASTM
170 AWS
AWWA
CPSC
CSA
171 DOL
FDA
FS
ICC
172 IIAR
MSS
NAIMA
NBBI
NFPA
173 NSF
174 SMACNA
UL
178 CHAPTER 16 INSTALLATION AND TESTING OF OIL OR LIQUID FUEL-FIRED EQUIPMENT
SECTION 1601 GENERAL
SECTION 1602 EQUIPMENT PLACEMENT
SECTION 1603 PILOT OPERATION
SECTION 1604 BURNER OPERATION
SECTION 1605 TEST METHODS
180 SECTION 1606 EQUIPMENT
182 APPENDIX A CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 CHIMNEY CONNECTOR SYSTEMS
183 FIGURE A-1—continued CHIMNEY CONNECTOR SYSTEMS
184 APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
186 1346.6010 APPENDIX C
TABLE C-1 RECOMMENDED CAPACITIES FOR DOMESTIC KITCHEN EXHAUST HOODS
188 INDEX
194 ANSI/ASHRAE STANDARD 62.2-2016 VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY IN RESIDENTIAL BUILDINGS TITLE PAGE
195 ASHRAE STANDING STANDARD PROJECT COMMITTEE 62.2
ASHRAE STANDARDS COMMITTEE 2015–2016
SPECIAL NOTE
DISCLAIMER
ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS
196 CONTENTS
NOTE
COPYRIGHT
197 FOREWORD
1. PURPOSE
2. SCOPE
198 3. DEFINITIONS
199 4. DWELLING-UNIT VENTILATION
EQUATION 4.1A
EQUATION 4.1B
EQUATION 4.2
200 TABLE 4.1a (I-P) VENTILATION AIR REQUIREMENTS, cfm
TABLE 4.1b (SI) VENTILATION AIR REQUIREMENTS, L/s
EQUATION 4.3
EQUATION 4.4
EQUATION 4.5A
EQUATION 4.5B
EQUATION 4.6
201 5. LOCAL EXHAUST
202 TABLE 5.1 DEMAND-CONTROLLLED LOCAL VENTILATION EXHAUST AIRFLOW RATES
TABLE 5.2 CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLOW RATES
TABLE 5.3 PRESCRIPTIVE DUCT SIZING
6. OTHER REQUIREMENTS
204 7. AIR-MOVING EQUIPMENT
8. CLIMATE DATA
9. REFERENCES
205 FIGURE 8.1 CLIMATE ZONES FOR U.S. LOCATIONS
207 NORMATIVE APPENDIX A EXISTING BUILDINGS
A1. SUMMARY
A2. DWELLING-UNIT MECHANICAL VENTILATION RATE
A3. LOCAL EXHAUST
A4. AIR-MOVING EQUIPMENT
208 NORMATIVE APPENDIX B INFILTRATION EFFECTIVENESS WEATHER AND SHIELDING FACTORS
TABLE B1 U.S. CLIMATES
209 TABLE B1 U.S. CLIMATES (Continued)
210 TABLE B1 U.S. CLIMATES (Continued)
211 TABLE B1 U.S. CLIMATES (Continued)
212 TABLE B1 U.S. CLIMATES (Continued)
213 TABLE B1 U.S. CLIMATES (Continued)
214 TABLE B1 U.S. CLIMATES (Continued)
215 TABLE B1 U.S. CLIMATES (Continued)
216 TABLE B1 U.S. CLIMATES (Continued)
217 TABLE B1 U.S. CLIMATES (Continued)
218 TABLE B1 U.S. CLIMATES (Continued)
219 TABLE B1 U.S. CLIMATES (Continued)
220 TABLE B1 U.S. CLIMATES (Continued)
221 TABLE B1 U.S. CLIMATES (Continued)
222 TABLE B1 U.S. CLIMATES (Continued)
223 TABLE B1 U.S. CLIMATES (Continued)
224 TABLE B1 U.S. CLIMATES (Continued)
225 TABLE B1 U.S. CLIMATES (Continued)
226 TABLE B1 U.S. CLIMATES (Continued)
227 TABLE B1 U.S. CLIMATES (Continued)
228 TABLE B1 U.S. CLIMATES (Continued)
229 TABLE B1 U.S. CLIMATES (Continued)
230 TABLE B1 U.S. CLIMATES (Continued)
231 TABLE B1 U.S. CLIMATES (Continued)
232 TABLE B1 U.S. CLIMATES (Continued)
233 TABLE B1 U.S. CLIMATES (Continued)
234 TABLE B2 CANADIAN CLIMATES
235 TABLE B2 CANADIAN CLIMATES (Continued)
236 NORMATIVE APPENDIX C RELATIVE EXPOSURE
C1. SUMMARY
C2. TIME-VARYING TOTAL VENTILATION
EQUATION C1
EQUATION C2
EQUATION C3
EQUATION C4
EQUATION C5
EQUATION C6
EQUATION C7
EQUATION C8
C3. RELATIVE EXPOSURE CALCULATION
EQUATION C9
EQUATION C10
237 TABLE C1 WIND SPEED MULTIPLIER, G
TABLE C2 SHELTER FACTOR, s
TABLE C3 (I-P) WIND COEFFICIENT, Cw
TABLE C3 (SI) WIND COEFFICIENT, Cw
TABLE C4 (I-P) STACK COEFFICIENT, Cs
TABLE C4 (SI) STACK COEFFICIENT, Cs
238 INFORMATIVE APPENDIX D ADDENDA DESCRIPTION INFORMATION
TABLE D1 ADDENDA TO ANSI/ASHRAE STANDARD 62.2-2013
239 TABLE D1 ADDENDA TO ANSI/ASHRAE STANDARD 62.2-2013 (Continued)
240 TABLE D1 ADDENDA TO ANSI/ASHRAE STANDARD 62.2-2013 (Continued)
241 NOTICE
242 FORM FOR SUBMITTAL OF PROPOSED CHANGE TO AN ASHRAE STANDARD UNDER CONTINUOUS MAINTENANCE
243 POLICY STATEMENT DEFINING ASHRAE’S CONCERN FOR THE ENVIRONMENTAL IMPACT OF ITS ACTIVITIES
245 ABOUT ASHRAE
IMPORTANT NOTICES ABOUT THIS STANDARD
246 ANSI/ASHRAE STANDARD 154-2016 VENTILATION FOR COMMERCIAL COOKING OPERATIONS TITLE PAGE
247 ASHRAE STANDING STANDARD PROJECT COMMITTEE 154
ASHRAE STANDARDS COMMITTEE 2016–2017
SPECIAL NOTE
DISCLAIMER
ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDS
248 CONTENTS
NOTE
COPYRIGHT
249 FOREWORD
1. PURPOSE
2. SCOPE
3. DEFINITIONS
252 4. EXHAUST HOODS
254 TABLE 1 TYPE I HOOD REQUIREMENTS BY APPLIANCE TYPE
255 TABLE 2 TYPE II HOOD REQUIREMENTS BY APPLIANCE DESCRIPTION
256 TABLE 2 TYPE II HOOD REQUIREMENTS BY APPLIANCE DESCRIPTION (Continued)
TABLE 3 MINIMUM OVERHANG REQUIREMENTS FOR TYPE II HOODS
TABLE 4 TYPE II HOOD MINIMUM NET EXHAUST AIRFLOW RATES
FIGURE 1 3 × 3 ft (914 × 914 mm) PARTIAL SIDE PANEL
257 5. EXHAUST SYSTEMS
258 6. REPLACEMENT AIR
259 7. SYSTEM CONTROLS
8. ADMINISTRATION AND COMPLIANCE
9. REFERENCES
261 INFORMATIVE ANNEX A EXAMPLES OF AIR BALANCING
A1. CONVENTIONAL AIR BALANCING
A2. BEST PRACTICE AIR BALANCING
A3. PRESSURE DIFFERENTIALS
262 TABLE A-1 AIR BALANCE FOR CONVENTIONAL RESTAURANT
FIGURE A-1 CONVENTIONAL RESTAURANT AIR BALANCE EXAMPLE
263 TABLE A-2 AIR BALANCE FOR BEST PRACTICE RESTAURANT
FIGURE A-2 BEST PRACTICES RESTAURANT AIR BALANCE EXAMPLE
264 INFORMATIVE ANNEX B ALTERNATIVE AIRFLOW CALCULATION METHOD
B1. EXHAUST AIRFLOW CALCULATION
EQUATION B-1
B2. THERMAL PLUME CALCULATION
EQUATION B-2
EQUATION B-3
EQUATION B-4
B3. AIRFLOW CALCULATION EXAMPLE
265 TABLE B-1 UNLISTED HOOD EFFECTIVENESS VALUES
TABLE B-2 REDUCTION FACTORS
TABLE B-3 EXAMPLE APPLIANCE SPECIFICATIONS
TABLE B-4 HYDRAULIC DIAMETER FOR EACH APPLIANCE CALCULATED USING EQUATION B-3
TABLE B-5 THERMAL PLUME AIRFLOWS CALCULATED FOR EACH APPLIANCE USING EQUATION B-2
266 INFORMATIVE ANNEX C HOOD ENERGY SAVINGS CALCULATION
267 TABLE C-1 ANNEX C NOMENCLATURE
268 INFORMATIVE ANNEX D USING ASHRAE STANDARD 154 TO DETERMINE HOOD OVERHANGS AND EXHAUST AIRFLOWS
D1. APPLIANCES UNDERNEATH THE HOOD
D2. UNHOODED APPLIANCE DESCRIPTIONS
269 TABLE D-1 MINIMUM HOOD LENGTH
TABLE D-2 MINIMUM HOOD DEPTH
TABLE D-3 HOODED APPLIANCE HEAT GAIN ESTIMATIONS
TABLE D-4 UNHOODED APPLIANCE HEAT GAIN ESTIMATIONS
270 INFORMATIVE ANNEX E INFORMATIVE BIBLIOGRAPHY
272 NOTICE
273 FORM FOR SUBMITTAL OF PROPOSED CHANGE TO AN ASHRAE STANDARD UNDER CONTINUOUS MAINTENANCE
274 POLICY STATEMENT DEFINING ASHRAE’S CONCERN FOR THE ENVIRONMENTAL IMPACT OF ITS ACTIVITIES
275 ABOUT ASHRAE
IMPORTANT NOTICES ABOUT THIS STANDARD
276 2020 MINNESOTA FUEL GAS CODE
2020 MINNESOTA FUEL GAS CODE SYMBOLS AND NOTATIONS IN THE CODE
278 PREFACE
282 EFFECTIVE USE OF THE INTERNATIONAL FUEL GAS CODE
284 TABLE OF CONTENTS
286 2020 MINNESOTA FUEL GAS CODE
1346.5050 TITLE; INCORPORATION BY REFERENCE
1346.5060 REFERENCES TO OTHER INTERNATIONAL CODE COUNCIL (ICC) CODES
1346.5101 ADMINISTRATION
288 CHAPTER 1 SCOPE AND ADMINISTRATION
290 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
298 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
299 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
300 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
301 EQUATION 3-1
EQUATION 3-2
TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR CATEGORY I, III, AND IV GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 BTU/HR
302 FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
303 SECTION 305 (IFGC) INSTALLATION
304 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
305 SECTION 307 (IFGC) CONDENSATE DISPOSAL
306 SECTION 308 (IFGS) CLEARANCE REDUCTION
SECTION 309 (IFGC) ELECTRICAL
307 TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTIONa through k
SECTION 310 (IFGS) ELECTRICAL BONDING
308 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
309 SECTION 311 CARBON MONOXIDE ALARMS
310 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
311 EQUATION 4-1
EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
312 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
313 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
314 TABLE 402.4(2)A PIPE SIZING TABLE FOR NATURAL GAS
315 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
316 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
317 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
318 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
319 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
320 TABLE 402.4(8) SEMIRIGID COPPER TUBING
321 TABLE 402.4(9) SEMIRIGID COPPER TUBING
322 TABLE 402.4(10) SEMIRIGID COPPER TUBING
323 TABLE 402.4(11) SEMIRIGID COPPER TUBING
324 TABLE 402.4(12) SEMIRIGID COPPER TUBING
325 TABLE 402.4(13) SEMIRIGID COPPER TUBING
326 TABLE 402.4(14) SEMIRIGID COPPER TUBING
327 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
328 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
329 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
330 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
331 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
332 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
333 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
334 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
335 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
336 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
337 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
338 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
339 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
340 TABLE 402.4(29) SEMIRIGID COPPER TUBING
341 TABLE 402.4(30) SEMIRIGID COPPER TUBING
342 TABLE 402.4(31) SEMIRIGID COPPER TUBING
343 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
344 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
345 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
346 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
347 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
348 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
349 SECTION 403 (IFGS) PIPING MATERIALS
350 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
351 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
354 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
355 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
356 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
357 SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
358 SECTION 410 (IFGC) FLOW CONTROLS
SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
360 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
361 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
362 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
363 SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
366 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
367 SECTION 502 (IFGC) VENTS
368 SECTION 503 (IFGS) VENTING OF APPLIANCES
369 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
371 FIGURE 503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE NOT LESS THAN 8 FEET FROM A VERTICAL WALL
374 TABLE 503.8 THROUGH-THE-WALL, DIRECT-VENT TERMINATION CLEARANCES
TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
375 TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
376 TABLE 503.10.5a CLEARANCES FOR CONNECTORS
377 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
379 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
381 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
383 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
384 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
385 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
386 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
387 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
388 TABLE 504.2(2)—continued TYPE B DOUBLE-WALL GAS VENT
389 TABLE 504.2(3) MASONRY CHIMNEY
390 TABLE 504.2(3)—continued MASONRY CHIMNEY
391 TABLE 504.2(4) MASONRY CHIMNEY
392 TABLE 504.2(4)—continued MASONRY CHIMNEY
393 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
394 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
395 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
396 TABLE 504.3(1)—continued TYPE B DOUBLE-WALL VENT
397 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
398 TABLE 504.3(3) MASONRY CHIMNEY
399 TABLE 504.3(4) MASONRY CHIMNEY
400 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
401 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY—continued
402 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
404 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
405 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
406 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
407 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
408 SECTION 615 (IFGC) SAUNA HEATERS
409 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
410 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
411 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
412 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
413 SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
414 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
415 SECTION 704 (IFGC) PIPING, USE AND HANDLING
416 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
417 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
418 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
419 ASME
420 ASTM
421 CGA
CSA
DOTn
ICC
422 MSS
NFPA
UL
424 1346.5900 CHAPTER 9 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
CHAPTER 9 INSTALLATION AND TESTING OF FUEL GAS-FIRED EQUIPMENT
428 1346.6000 CHAPTER 10 MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND APPLIANCE INSTALLATION
CHAPTER 10 MANUFACTURED HOME PARK/COMMUNITY FUEL GAS EQUIPMENT AND APPLIANCE INSTALLATION
TABLE 1002 DEMAND FACTORS FOR CALCULATING GAS PIPING SYSTEMS IN MANUFACTURED HOME PARKS AND COMMUNITIES
430 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
431 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
432 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
433 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
435 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
436 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
437 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
438 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
440 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
441 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
442 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
443 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
444 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
445 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
447 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
448 FIGURE B-19
450 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
452 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
453 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
454 D.5 INSPECTIONS TO BE PERFORMED WIHT THE APPLIANCE OPERATING
455 D.6 APPLIANCE-SPECIFIC INSPECTIONS
456 TABLE D.6 CO THRESHOLDS
458 APPENDIX E WORKSHEET E-1 (FUEL GAS CODE)
IFGC APPENDIX E, WORKSHEET E-1 RESIDENTIAL COMBUSTION AIR CALCULATION METHOD (FOR FURNACE, BOILER, AND/OR WATER HEATER IN THE SAME SPACE)
460 IFGC APPENDIX E, TABLE E-1 RESIDENTIAL COMBUSTION AIR REQUIRED VOLUME (REQUIRED INTERIOR VOLUME BASED ON INPUT RATING OF APPLIANCES)
462 INDEX
466 ICC EVALUATION SERVICE
467 ICC’S DIGITAL CODES LIBRARY
468 ICC ASSESSMENT CENTER
469 ICC LEARNING CENTER
MN Mech FuelGasCode 1stptg 2020